PNO-V-86-032, on 860612,facility Resumed Operation After Second Refueling Outage.Outage Included Replacement of Reactor Coolant Pump Seal Packages & Testing motor-operated Valves Per IE Bulletin 86-003

From kanterella
Jump to navigation Jump to search
PNO-V-86-032:on 860612,facility Resumed Operation After Second Refueling Outage.Outage Included Replacement of Reactor Coolant Pump Seal Packages & Testing motor-operated Valves Per IE Bulletin 86-003
ML20199E062
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 06/16/1986
From: Huey R, Johnson P, Narbut P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To:
References
IEB-86-003, IEB-86-3, PNO-V-86-032, PNO-V-86-32, NUDOCS 8606230173
Download: ML20199E062 (1)


L , .

,7 i

~

y*

5 T

PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE--PNO-V-86-32 , Date: 06/16/86 This preliminary notification constitutes EARLY notice of events N 'POSSIBLE safety or public

.. int:r:st significance. The information presented is as initially received without verification cr evaluation and is basically all that is known by' Region V staff. on this date.

' FACILITY:- Southern California Edison Company l Licensee Emergency Classification San Onofre Unit 2 $

Notification of Unusual Event E . DOCKET NO.'50-361 Alert Site Area Emergency

, General Emergency xx-Not Applicable

SUBJECT:

STARTUP FOLLOWING SECOND REFUELING OUTAGE

.The Unit 2 facility resumed operation on June 12, 1986 af ter completing its second refueling outag]. In addition to refueling, the outage also included replacement of,the reactor coolant

, pump coal packages with a new design which should eliminate the need to replace the seal packa~ge c:ch time the reactor coolant pumps are stopped. . Additionally, during the outage, the licensee.

' completed testing of motor operated valves in.accordance with the requirements of.IE Bull tin 85-03, performed Inservice Inspection -(ISI) of the reactor vessel flange /and nossles, perftrued the mechanical snubber surveillance (which identified drag force problems on large snrbb:rs), and performed steam generator tube inspection (wh .:h identified problems with the .

loo:::ing of previously installed tube plugs). The identified problems were resolved prior to r:st:rt. The three unit fac'.lity now has Units.2 and 3 in operation with Unit 1 forecast to rc,ttrn to operation on July 8, 1986.

This information is current as of 8:00 am, June 16,'1986.

CONTACT: P. John tion Chief R. Huey, Senior Resident Inspector FTS 463- 74 (714) 492-2641 P. Narbut, Pr ect Engineer FTS463-3730{

h6230173860616 YM~ -03g py DISTRIBUTION H St. NNBB Phillips E/U W111ste Air Rightsh'N Mail

' Chairman Palladino EDO NRR IE NMSS ADMIDMB Comm. Zech PA= OIA RES DOT Trans Only Comm. Bernthal MPA AEOD Comm.' Roberts ELD Come, Asselstine Regions:

SECY INPO8.'2] NSAC gl 2 3--

-ACRS Licensee /O l3 (,

CA (Reactor Licensees) REGION V: FORM 211 ped Resident Inspector,_ (Revised 3/14/83)

~

ffYe 1