Category:INSPECTION REPORT
MONTHYEARIR 05000361/19990121999-10-15015 October 1999 Insp Repts 50-361/99-12 & 50-362/99-12 on 990808-0918. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19990091999-08-27027 August 1999 Insp Repts 50-361/99-09 & 50-362/99-09 on 990627-0807. Non-cited Violations Identified.Major Areas Inspected:Maint, Operations,Engineering & Plant Support IR 05000361/19990081999-07-0909 July 1999 Insp Repts 50-361/99-08 & 50-362/99-08 on 990516-0626.One Violation Noted & Being Treated as Noncited Violation:Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20196B5951999-06-0909 June 1999 Errata to Insp Repts 50-361/99-04 & 50-362/99-04.Corrected Pages Replace Pps 14-17 of Insp Repts IR 05000361/19990061999-06-0808 June 1999 Insp Repts 50-361/99-06 & 50-362/99-06 on 990404-0515.Non- Cited Violations Identified.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000361/19980181999-06-0202 June 1999 Revised Pages 1-5,7,10 & 11 for Insp Repts 50-361/98-18 & 50-362/98-18 IR 05000361/19990071999-05-18018 May 1999 Partially Withheld Insp Repts 50-361/99-07 & 50-362/99-07 on 990426-29.Major Areas Inspected:Licensee Physical Security Program.Details Withheld (Ref 10CFR2.790) IR 05000361/19990051999-05-10010 May 1999 Insp Repts 50-361/99-05 & 50-362/99-05 on 990426-30.No Violations Noted.Major Areas Inspected:Plant Support.Failure to Survey Radioactive Matl Prior to Removal from Restricted Area Identified as Unresolved Pending Investigation IR 05000361/19990031999-04-20020 April 1999 Insp Repts 50-361/99-03 & 50-362/99-03 on 990205-0312.One Violation Noted & Being Treated as non-cited Violation.Major Areas Inspected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000361/19990041999-04-20020 April 1999 Insp Repts 50-361/99-04 & 50-362/99-04 on 990221-0403.Three Violations Noted & Being Treated as non-cited Violations. Major Areas Inspected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000361/19990011999-03-30030 March 1999 Insp Repts 50-361/99-01 & 50-362/99-01 on 990103-0220.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19980191999-01-28028 January 1999 Insp Repts 50-361/98-19 & 50-362/98-19 on 981112-990102.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20199H4521999-01-15015 January 1999 Insp Repts 50-361/98-18 & 50-362/98-18 on 981109-1218. Violations Noted.Major Areas Inspected:Operations, Maintenance & Engineering IR 05000361/19980221999-01-0707 January 1999 Insp Repts 50-361/98-22 & 50-362/98-22 on 981207-11. Violations Noted.Major Areas Inspected:Announced Insp Was Conducted to Review Portions of Radiation Protection Program IR 05000361/19980141999-01-0404 January 1999 Insp Repts 50-361/98-14 & 50-362/98-14 on 981019-1106. Violations Noted.Major Areas Inspected:Review of Design & Licensing Basis for Component CWS & Associated Support Sys & Review of 10CFR50.59 Safety Evaluation Program IR 05000361/19980211998-12-30030 December 1998 Insp Repts 50-361/98-21 & 50-362/98-21 on 981207-11. Violations Noted.Major Areas Inspected:Licensee Physical Security Program IR 05000361/19980201998-12-17017 December 1998 Insp Repts 50-361/98-20 & 50-362/98-20 on 981207-11.No Violations Noted.Major Areas Inspected:Plant Support IR 05000361/19980171998-12-14014 December 1998 Insp Repts 50-361/98-17 & 50-362/98-17 on 981004-1114.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000206/19980191998-12-0404 December 1998 Insp Repts 50-206/98-19 & 50-301/98-19 on 981004.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000361/19980161998-10-20020 October 1998 Insp Repts 50-361/98-16 & 50-362/98-16 on 980823-1003.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20154H3171998-10-0707 October 1998 Insp Repts 50-361/98-12 & 50-362/98-12 on 980713-17. Violations Noted.Major Areas Inspected:Licensee Physical Security Program IR 05000361/19980151998-09-25025 September 1998 Insp Repts 50-361/98-15 & 50-362/98-15 on 980824-28.No Violations Noted.Major Areas Inspected:Licensee Physical Security Program IR 05000361/19980101998-09-0202 September 1998 Insp Repts 50-361/98-10 & 50-362/98-10 on 980817-21.No Violations Noted.Major Areas Inspected:Plant Support IR 05000361/19980131998-09-0101 September 1998 Insp Repts 50-361/98-13 & 50-362/98-13 on 980712-0822.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20237D7261998-08-21021 August 1998 Insp Repts 50-361/98-11 & 50-362/98-11 on 980720-24.No Violations Noted.Major Areas Inspected:Exposure Controls, Controls of Radioactive Matl & Contamination,Surveying & Monitoring & QA Oversight of Radiation Protection Program IR 05000361/19980081998-08-19019 August 1998 Insp Repts 50-361/98-08 & 50-362/98-08 on 980727-31.No Violations Noted.Major Areas Inspected:Plant Support IR 05000361/19980091998-08-0404 August 1998 Insp Repts 50-361/98-09 & 50-362/98-09 on 980709-10.No Violations Noted.Major Areas Inspected:Operational Status of Emergency Preparedness Program,Using Simulator Walkthrough to Focus on Training of Assigned Key Roles for Emergencies IR 05000361/19980071998-07-22022 July 1998 Insp Repts 50-361/98-07 & 50-362/98-07 on 980607-0711. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19980061998-06-30030 June 1998 Insp Repts 50-361/98-06 & 50-362/98-06 on 980426-0606.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19980011998-05-29029 May 1998 Insp Repts 50-361/98-01 & 50-362/98-01 on 980202-0410.No Violations Noted.Major Areas Inspected:Maintenance, Engineering & Plant Support IR 05000361/19980041998-05-27027 May 1998 Insp Repts 50-361/98-04 & 50-362/98-04 on 980315-0425. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19980031998-03-25025 March 1998 Insp Repts 50-361/98-03 & 50-362/98-03 on 980201-0314. Violations Noted.Major Areas Inspected:Plant Operation, Maint,Engineering & Plant Support IR 05000361/19980021998-03-11011 March 1998 Insp Repts 50-361/98-02 & 50-362/98-02 on 980209-13.No Violations Noted.Major Areas Inspected:Licensee Physical Security Program,Including Review of Alarm Stations,Access Control,Vital Area Barriers & Emergency Power Supply ML20202E9011998-02-11011 February 1998 Insp Repts 50-361/97-27 & 50-362/97-27 on 971221-980131. Violation Noted.Major Areas Inspected:Licensee Operations, 21int,engineering & Plant Support IR 05000361/19970261998-01-0505 January 1998 Insp Repts 50-361/97-26 & 50-362/97-26 on 971208-12.No Violations Noted.Major Areas Inspected:Operationsl Status of Licensee Emergency Preparedness Program.Emphasis Was Placed on Changes Occurred Since Last Emergency Preparedness Insp IR 05000361/19970251997-12-30030 December 1997 Insp Repts 50-361/97-25 & 50-362/97-25 on 971109-1220. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19970241997-12-24024 December 1997 Partialy Withheld Insp Repts 50-361/97-24 & 50-362/97-24 on 971117-21 & 1203-05 (Ref 10CFR73.21).Violations Being Considered for Ea.Major Areas Inspected:Physical Security Program IR 05000361/19970211997-11-25025 November 1997 Insp Repts 50-361/97-21 & 50-362/97-21 on 971027-31.One Exercise Weakness Identified.Major Areas Inspected: Implementation of Emergency Plan & Procedures During Biennial Emergency Preparedness Exercise IR 05000361/19970231997-11-19019 November 1997 Insp Repts 50-361/97-23 & 50-362/97-23 on 970928-1108.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19970181997-11-17017 November 1997 Insp Repts 50-361/97-18 & 50-362/97-18,cancelled.No Insp Rept Will Be Issued IR 05000361/19970201997-10-16016 October 1997 Insp Repts 50-361/97-20 & 50-362/97-20 on 970828-0919. Violations Noted.Major Areas Inspected:Licensed Operator Requalification Program Following Guidelines in IP 71001, Licensed Operator Requalification Program Evaluation IR 05000361/19970191997-10-10010 October 1997 Insp Repts 50-361/97-19 & 50-362/97-19 on 970817-0927. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support Re Security Personnel IR 05000361/19970151997-09-10010 September 1997 Insp Repts 50-361/97-15 & 50-362/97-15 on 970630-0902. Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000361/19970171997-09-0404 September 1997 Insp Repts 50-361/97-17 & 50-362/97-17 on 970706-0816. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000361/19970111997-08-20020 August 1997 Insp Repts 50-361/97-11 & 50-362/97-11 on 970602-13 & 0804- 07.Violations Noted.Major Areas Inspected:Licensee Implementation of TSs for Both Units Along W/Resolution of Open Issues Developed Due to Problems W/Licensee Program ML20149J9621997-07-22022 July 1997 Insp Repts 50-361/97-12 & 50-362/97-12 on 970518-0705. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support Re Supervisor Failure to Follow Procedural Requirement for Controlling Security Badge IR 05000361/19970141997-07-14014 July 1997 Partially Withheld Insp Repts 50-361/97-14 & 50-362/97-14 on 970609-13 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Review of Testing & Maint,Plans & Procedures, Audits,Access Authorization & Protection of Safeguards Info IR 05000361/19970131997-07-0202 July 1997 Insp Repts 50-361/97-13 & 50-362/97-13 on 970609-13.No Violations Noted.Major Areas Inspected:Reviewed Program to Maintain Occupational Exposures as Low as Reasonably Achievable & Quality Oversight of Radiation Program IR 05000361/19970091997-06-0202 June 1997 Insp Repts 50-361/97-09 & 50-362/97-09 on 970406-0517.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19970061997-05-28028 May 1997 Insp Repts 50-361/97-06 & 50-362/97-06 on 970317-21 & 970331-0404.URI Identified.Major Areas Inspected:Cap,Fp Program & C/As for Previously Identified Violations & Open Items 1999-08-27
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000361/19990121999-10-15015 October 1999 Insp Repts 50-361/99-12 & 50-362/99-12 on 990808-0918. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19990091999-08-27027 August 1999 Insp Repts 50-361/99-09 & 50-362/99-09 on 990627-0807. Non-cited Violations Identified.Major Areas Inspected:Maint, Operations,Engineering & Plant Support IR 05000361/19990081999-07-0909 July 1999 Insp Repts 50-361/99-08 & 50-362/99-08 on 990516-0626.One Violation Noted & Being Treated as Noncited Violation:Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20196B5951999-06-0909 June 1999 Errata to Insp Repts 50-361/99-04 & 50-362/99-04.Corrected Pages Replace Pps 14-17 of Insp Repts IR 05000361/19990061999-06-0808 June 1999 Insp Repts 50-361/99-06 & 50-362/99-06 on 990404-0515.Non- Cited Violations Identified.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000361/19980181999-06-0202 June 1999 Revised Pages 1-5,7,10 & 11 for Insp Repts 50-361/98-18 & 50-362/98-18 IR 05000361/19990071999-05-18018 May 1999 Partially Withheld Insp Repts 50-361/99-07 & 50-362/99-07 on 990426-29.Major Areas Inspected:Licensee Physical Security Program.Details Withheld (Ref 10CFR2.790) IR 05000361/19990051999-05-10010 May 1999 Insp Repts 50-361/99-05 & 50-362/99-05 on 990426-30.No Violations Noted.Major Areas Inspected:Plant Support.Failure to Survey Radioactive Matl Prior to Removal from Restricted Area Identified as Unresolved Pending Investigation IR 05000361/19990031999-04-20020 April 1999 Insp Repts 50-361/99-03 & 50-362/99-03 on 990205-0312.One Violation Noted & Being Treated as non-cited Violation.Major Areas Inspected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000361/19990041999-04-20020 April 1999 Insp Repts 50-361/99-04 & 50-362/99-04 on 990221-0403.Three Violations Noted & Being Treated as non-cited Violations. Major Areas Inspected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000361/19990011999-03-30030 March 1999 Insp Repts 50-361/99-01 & 50-362/99-01 on 990103-0220.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19980191999-01-28028 January 1999 Insp Repts 50-361/98-19 & 50-362/98-19 on 981112-990102.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20199H4521999-01-15015 January 1999 Insp Repts 50-361/98-18 & 50-362/98-18 on 981109-1218. Violations Noted.Major Areas Inspected:Operations, Maintenance & Engineering IR 05000361/19980221999-01-0707 January 1999 Insp Repts 50-361/98-22 & 50-362/98-22 on 981207-11. Violations Noted.Major Areas Inspected:Announced Insp Was Conducted to Review Portions of Radiation Protection Program IR 05000361/19980141999-01-0404 January 1999 Insp Repts 50-361/98-14 & 50-362/98-14 on 981019-1106. Violations Noted.Major Areas Inspected:Review of Design & Licensing Basis for Component CWS & Associated Support Sys & Review of 10CFR50.59 Safety Evaluation Program IR 05000361/19980211998-12-30030 December 1998 Insp Repts 50-361/98-21 & 50-362/98-21 on 981207-11. Violations Noted.Major Areas Inspected:Licensee Physical Security Program IR 05000361/19980201998-12-17017 December 1998 Insp Repts 50-361/98-20 & 50-362/98-20 on 981207-11.No Violations Noted.Major Areas Inspected:Plant Support IR 05000361/19980171998-12-14014 December 1998 Insp Repts 50-361/98-17 & 50-362/98-17 on 981004-1114.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000206/19980191998-12-0404 December 1998 Insp Repts 50-206/98-19 & 50-301/98-19 on 981004.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000361/19980161998-10-20020 October 1998 Insp Repts 50-361/98-16 & 50-362/98-16 on 980823-1003.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20154H3171998-10-0707 October 1998 Insp Repts 50-361/98-12 & 50-362/98-12 on 980713-17. Violations Noted.Major Areas Inspected:Licensee Physical Security Program IR 05000361/19980151998-09-25025 September 1998 Insp Repts 50-361/98-15 & 50-362/98-15 on 980824-28.No Violations Noted.Major Areas Inspected:Licensee Physical Security Program IR 05000361/19980101998-09-0202 September 1998 Insp Repts 50-361/98-10 & 50-362/98-10 on 980817-21.No Violations Noted.Major Areas Inspected:Plant Support IR 05000361/19980131998-09-0101 September 1998 Insp Repts 50-361/98-13 & 50-362/98-13 on 980712-0822.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20237D7261998-08-21021 August 1998 Insp Repts 50-361/98-11 & 50-362/98-11 on 980720-24.No Violations Noted.Major Areas Inspected:Exposure Controls, Controls of Radioactive Matl & Contamination,Surveying & Monitoring & QA Oversight of Radiation Protection Program IR 05000361/19980081998-08-19019 August 1998 Insp Repts 50-361/98-08 & 50-362/98-08 on 980727-31.No Violations Noted.Major Areas Inspected:Plant Support IR 05000361/19980091998-08-0404 August 1998 Insp Repts 50-361/98-09 & 50-362/98-09 on 980709-10.No Violations Noted.Major Areas Inspected:Operational Status of Emergency Preparedness Program,Using Simulator Walkthrough to Focus on Training of Assigned Key Roles for Emergencies IR 05000361/19980071998-07-22022 July 1998 Insp Repts 50-361/98-07 & 50-362/98-07 on 980607-0711. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19980061998-06-30030 June 1998 Insp Repts 50-361/98-06 & 50-362/98-06 on 980426-0606.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19980011998-05-29029 May 1998 Insp Repts 50-361/98-01 & 50-362/98-01 on 980202-0410.No Violations Noted.Major Areas Inspected:Maintenance, Engineering & Plant Support IR 05000361/19980041998-05-27027 May 1998 Insp Repts 50-361/98-04 & 50-362/98-04 on 980315-0425. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19980031998-03-25025 March 1998 Insp Repts 50-361/98-03 & 50-362/98-03 on 980201-0314. Violations Noted.Major Areas Inspected:Plant Operation, Maint,Engineering & Plant Support IR 05000361/19980021998-03-11011 March 1998 Insp Repts 50-361/98-02 & 50-362/98-02 on 980209-13.No Violations Noted.Major Areas Inspected:Licensee Physical Security Program,Including Review of Alarm Stations,Access Control,Vital Area Barriers & Emergency Power Supply ML20202E9011998-02-11011 February 1998 Insp Repts 50-361/97-27 & 50-362/97-27 on 971221-980131. Violation Noted.Major Areas Inspected:Licensee Operations, 21int,engineering & Plant Support IR 05000361/19970261998-01-0505 January 1998 Insp Repts 50-361/97-26 & 50-362/97-26 on 971208-12.No Violations Noted.Major Areas Inspected:Operationsl Status of Licensee Emergency Preparedness Program.Emphasis Was Placed on Changes Occurred Since Last Emergency Preparedness Insp IR 05000361/19970251997-12-30030 December 1997 Insp Repts 50-361/97-25 & 50-362/97-25 on 971109-1220. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19970241997-12-24024 December 1997 Partialy Withheld Insp Repts 50-361/97-24 & 50-362/97-24 on 971117-21 & 1203-05 (Ref 10CFR73.21).Violations Being Considered for Ea.Major Areas Inspected:Physical Security Program IR 05000361/19970211997-11-25025 November 1997 Insp Repts 50-361/97-21 & 50-362/97-21 on 971027-31.One Exercise Weakness Identified.Major Areas Inspected: Implementation of Emergency Plan & Procedures During Biennial Emergency Preparedness Exercise IR 05000361/19970231997-11-19019 November 1997 Insp Repts 50-361/97-23 & 50-362/97-23 on 970928-1108.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19970181997-11-17017 November 1997 Insp Repts 50-361/97-18 & 50-362/97-18,cancelled.No Insp Rept Will Be Issued IR 05000361/19970201997-10-16016 October 1997 Insp Repts 50-361/97-20 & 50-362/97-20 on 970828-0919. Violations Noted.Major Areas Inspected:Licensed Operator Requalification Program Following Guidelines in IP 71001, Licensed Operator Requalification Program Evaluation IR 05000361/19970191997-10-10010 October 1997 Insp Repts 50-361/97-19 & 50-362/97-19 on 970817-0927. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support Re Security Personnel IR 05000361/19970151997-09-10010 September 1997 Insp Repts 50-361/97-15 & 50-362/97-15 on 970630-0902. Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000361/19970171997-09-0404 September 1997 Insp Repts 50-361/97-17 & 50-362/97-17 on 970706-0816. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000361/19970111997-08-20020 August 1997 Insp Repts 50-361/97-11 & 50-362/97-11 on 970602-13 & 0804- 07.Violations Noted.Major Areas Inspected:Licensee Implementation of TSs for Both Units Along W/Resolution of Open Issues Developed Due to Problems W/Licensee Program ML20149J9621997-07-22022 July 1997 Insp Repts 50-361/97-12 & 50-362/97-12 on 970518-0705. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support Re Supervisor Failure to Follow Procedural Requirement for Controlling Security Badge IR 05000361/19970141997-07-14014 July 1997 Partially Withheld Insp Repts 50-361/97-14 & 50-362/97-14 on 970609-13 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Review of Testing & Maint,Plans & Procedures, Audits,Access Authorization & Protection of Safeguards Info IR 05000361/19970131997-07-0202 July 1997 Insp Repts 50-361/97-13 & 50-362/97-13 on 970609-13.No Violations Noted.Major Areas Inspected:Reviewed Program to Maintain Occupational Exposures as Low as Reasonably Achievable & Quality Oversight of Radiation Program IR 05000361/19970091997-06-0202 June 1997 Insp Repts 50-361/97-09 & 50-362/97-09 on 970406-0517.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19970061997-05-28028 May 1997 Insp Repts 50-361/97-06 & 50-362/97-06 on 970317-21 & 970331-0404.URI Identified.Major Areas Inspected:Cap,Fp Program & C/As for Previously Identified Violations & Open Items 1999-08-27
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARPNO-IV-99-043, on 991016,earthquake of Magnitude 7 Occurred. Plant Operations Were Not Disrupted.Unusual Event Classifications Were Exited within 1 H at Both Facilities.No Damage Was Indicated & No Residual Plant Effects Observed1999-10-18018 October 1999 PNO-IV-99-043:on 991016,earthquake of Magnitude 7 Occurred. Plant Operations Were Not Disrupted.Unusual Event Classifications Were Exited within 1 H at Both Facilities.No Damage Was Indicated & No Residual Plant Effects Observed IR 05000361/19990121999-10-15015 October 1999 Insp Repts 50-361/99-12 & 50-362/99-12 on 990808-0918. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19990091999-08-27027 August 1999 Insp Repts 50-361/99-09 & 50-362/99-09 on 990627-0807. Non-cited Violations Identified.Major Areas Inspected:Maint, Operations,Engineering & Plant Support IR 05000361/19990081999-07-0909 July 1999 Insp Repts 50-361/99-08 & 50-362/99-08 on 990516-0626.One Violation Noted & Being Treated as Noncited Violation:Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20196B5951999-06-0909 June 1999 Errata to Insp Repts 50-361/99-04 & 50-362/99-04.Corrected Pages Replace Pps 14-17 of Insp Repts IR 05000361/19990061999-06-0808 June 1999 Insp Repts 50-361/99-06 & 50-362/99-06 on 990404-0515.Non- Cited Violations Identified.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000361/19980181999-06-0202 June 1999 Revised Pages 1-5,7,10 & 11 for Insp Repts 50-361/98-18 & 50-362/98-18 ML20207E6701999-06-0202 June 1999 Corrected NOV from Insp on 981109-1218.Violations Noted:On 980907,Procedure SO23-1-3.1 Not Implemented by Operators,In That,When Chiller E335 Lube Oil Level Was Out of Sight High in Upper Sight Glass for More than 15 IR 05000361/19990071999-05-18018 May 1999 Partially Withheld Insp Repts 50-361/99-07 & 50-362/99-07 on 990426-29.Major Areas Inspected:Licensee Physical Security Program.Details Withheld (Ref 10CFR2.790) IR 05000361/19990051999-05-10010 May 1999 Insp Repts 50-361/99-05 & 50-362/99-05 on 990426-30.No Violations Noted.Major Areas Inspected:Plant Support.Failure to Survey Radioactive Matl Prior to Removal from Restricted Area Identified as Unresolved Pending Investigation IR 05000361/19993011999-05-0606 May 1999 NRC Operator Licensing Exam Repts 50-361/99-301 & 50-362/99-301 Administered on 990416.Exam Results:Two RO & Two SRO Applicants Passed Exam IR 05000361/19990031999-04-20020 April 1999 Insp Repts 50-361/99-03 & 50-362/99-03 on 990205-0312.One Violation Noted & Being Treated as non-cited Violation.Major Areas Inspected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000361/19990041999-04-20020 April 1999 Insp Repts 50-361/99-04 & 50-362/99-04 on 990221-0403.Three Violations Noted & Being Treated as non-cited Violations. Major Areas Inspected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000361/19990011999-03-30030 March 1999 Insp Repts 50-361/99-01 & 50-362/99-01 on 990103-0220.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20211K4341999-03-26026 March 1999 Partially Withheld Investigation Rept 4-1998-041. Noncompliance Noted.Major Areas Investigated:Coercion & Discrimination Against Access/Ffd Audit Team by SCE Management ML20204B3471999-03-16016 March 1999 Notice of Violation from Insp on 981109-1218.Violation Noted:Train B Emergency Chilled Water Sys Was Inoperable on Two Separate Periods (980806-26 & 0904-25),while Units 2 & 3 Were in Mode 1.No Action Was Taken to Restore Operability PNO-IV-99-018, on 990305,declared SONGS Units 2 & 3 Alert Because Potential Bomb Threat Occurred.Device Was 12-inch long,2-inch Diameter Copper Pipe,With Both Ends Capped. Licensee Notified State & Local Officials1999-03-0505 March 1999 PNO-IV-99-018:on 990305,declared SONGS Units 2 & 3 Alert Because Potential Bomb Threat Occurred.Device Was 12-inch long,2-inch Diameter Copper Pipe,With Both Ends Capped. Licensee Notified State & Local Officials ML20211K4421999-02-0505 February 1999 Partially Withheld Investigation Rept 4-1998-043.No Noncompliances Noted.Major Areas Investigated:Discrimination Against Contract Employee by Contract Foreman for Reporting Safety Concerns IR 05000361/19980191999-01-28028 January 1999 Insp Repts 50-361/98-19 & 50-362/98-19 on 981112-990102.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20211K4511999-01-26026 January 1999 Partially Withheld Investigation Rept 4-1998-045.No Nonconformance Noted.Major Areas Investigated:Discrimination Against Former Contract Employee by Supervisor for Reporting Concerns to Nuclear Safety Concerns Program IA-99-234, Partially Withheld Investigation Rept 4-1998-045.No Nonconformance Noted.Major Areas Investigated:Discrimination Against Former Contract Employee by Supervisor for Reporting Concerns to Nuclear Safety Concerns Program1999-01-26026 January 1999 Partially Withheld Investigation Rept 4-1998-045.No Nonconformance Noted.Major Areas Investigated:Discrimination Against Former Contract Employee by Supervisor for Reporting Concerns to Nuclear Safety Concerns Program ML20199H4481999-01-15015 January 1999 Notice of Violation from Insp on 981109-1218.Violation Noted:On 980907,procedure SO23-1-1.3 Not Implemented by Operators,Therefore Chiller E335 Lube Oil Pump Operating Time Exceeded Approximately 15 Seconds ML20199H4521999-01-15015 January 1999 Insp Repts 50-361/98-18 & 50-362/98-18 on 981109-1218. Violations Noted.Major Areas Inspected:Operations, Maintenance & Engineering ML20206R2091999-01-0707 January 1999 Notice of Violation from Insp on 981207-11.Violations Noted:Workers Did Not Inform Health Physics Control Personnel of Work Location Prior to Entry in Radiological Controlled Area IR 05000361/19980221999-01-0707 January 1999 Insp Repts 50-361/98-22 & 50-362/98-22 on 981207-11. Violations Noted.Major Areas Inspected:Announced Insp Was Conducted to Review Portions of Radiation Protection Program IR 05000361/19980141999-01-0404 January 1999 Insp Repts 50-361/98-14 & 50-362/98-14 on 981019-1106. Violations Noted.Major Areas Inspected:Review of Design & Licensing Basis for Component CWS & Associated Support Sys & Review of 10CFR50.59 Safety Evaluation Program ML20198S7971999-01-0404 January 1999 Exam Repts 50-361/98-302 & 50-362/98-302 on 981115-1203.Exam Results:Out of Nine SRO Applicants & Five RO Applicants,Ten Applicants Satisfied Requirements of 10CFR55 & Appropriate Licenses Have Been Issued ML20198S9171999-01-0404 January 1999 Notice of Violation from Insp on 981019-1106.Violation Noted:As of 981106,appropriate Quality Standards as Described in UFSAR Section 9.2.2.1 & in App 3.2A Not Specified & Included in Design Documents for Electrical IR 05000361/19980211998-12-30030 December 1998 Insp Repts 50-361/98-21 & 50-362/98-21 on 981207-11. Violations Noted.Major Areas Inspected:Licensee Physical Security Program ML20198N5221998-12-30030 December 1998 Notice of Violation from Insp on 981207-11.Violation Noted: Approximately 70% of Security Officers Had Not Been Trained or Qualified with 9 Milimeter Rifle Prior to Being Allowed to Perform on-shift Security Duties with That Rifle IR 05000361/19980201998-12-17017 December 1998 Insp Repts 50-361/98-20 & 50-362/98-20 on 981207-11.No Violations Noted.Major Areas Inspected:Plant Support IR 05000361/19980171998-12-14014 December 1998 Insp Repts 50-361/98-17 & 50-362/98-17 on 981004-1114.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000206/19980191998-12-0404 December 1998 Insp Repts 50-206/98-19 & 50-301/98-19 on 981004.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support ML20203B7051998-11-0404 November 1998 EN-98-065:informs Commission That Staff Intends to Exercise Enforcement Discretion Per Section VII.B.6 of Enforcement Policy & Not Propose Civil Penalty Nor Issue NOV to Licensee for Severity Level III Violation IR 05000361/19980161998-10-20020 October 1998 Insp Repts 50-361/98-16 & 50-362/98-16 on 980823-1003.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20154H3131998-10-0707 October 1998 Notice of Violations from Insp on 980713-17.Violations Noted:Licensee Had Not Established Specific Procedures for Employment of Compensatory Measures Resulting from Security Computer Failure ML20154H3171998-10-0707 October 1998 Insp Repts 50-361/98-12 & 50-362/98-12 on 980713-17. Violations Noted.Major Areas Inspected:Licensee Physical Security Program IR 05000361/19980151998-09-25025 September 1998 Insp Repts 50-361/98-15 & 50-362/98-15 on 980824-28.No Violations Noted.Major Areas Inspected:Licensee Physical Security Program PNO-IV-98-041, on 980918,control Room Operators Observed Alarm on One Channel of Main Condenser Steam Jet Air Ejector Radiation Monitoring Equipment,Which Indicated That Activity of Condenser Exhaust Had Increased by About Two Decades1998-09-18018 September 1998 PNO-IV-98-041:on 980918,control Room Operators Observed Alarm on One Channel of Main Condenser Steam Jet Air Ejector Radiation Monitoring Equipment,Which Indicated That Activity of Condenser Exhaust Had Increased by About Two Decades IR 05000361/19980101998-09-0202 September 1998 Insp Repts 50-361/98-10 & 50-362/98-10 on 980817-21.No Violations Noted.Major Areas Inspected:Plant Support IR 05000361/19980131998-09-0101 September 1998 Insp Repts 50-361/98-13 & 50-362/98-13 on 980712-0822.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20237D7261998-08-21021 August 1998 Insp Repts 50-361/98-11 & 50-362/98-11 on 980720-24.No Violations Noted.Major Areas Inspected:Exposure Controls, Controls of Radioactive Matl & Contamination,Surveying & Monitoring & QA Oversight of Radiation Protection Program IR 05000361/19980081998-08-19019 August 1998 Insp Repts 50-361/98-08 & 50-362/98-08 on 980727-31.No Violations Noted.Major Areas Inspected:Plant Support IR 05000361/19980091998-08-0404 August 1998 Insp Repts 50-361/98-09 & 50-362/98-09 on 980709-10.No Violations Noted.Major Areas Inspected:Operational Status of Emergency Preparedness Program,Using Simulator Walkthrough to Focus on Training of Assigned Key Roles for Emergencies ML20236V6041998-07-22022 July 1998 Notice of Violation from Insp on 980607-0711.Violation Noted:Abnormal Operating Instruction S023-13-3,temporary Change Notice 4-2,not Appropriate for Circumstances in That Procedure Did Not Differentiate Between Various Weather IR 05000361/19980071998-07-22022 July 1998 Insp Repts 50-361/98-07 & 50-362/98-07 on 980607-0711. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19983011998-07-15015 July 1998 NRC Operator Licensing Exam Repts 50-361/98-301 & 50-362/98-301 Administered on 980614-19.All Applicants Passed Written Exam.Seven of Eight Applicants Passed All Sections of Operating Test IR 05000361/19980061998-06-30030 June 1998 Insp Repts 50-361/98-06 & 50-362/98-06 on 980426-0606.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000361/19980011998-05-29029 May 1998 Insp Repts 50-361/98-01 & 50-362/98-01 on 980202-0410.No Violations Noted.Major Areas Inspected:Maintenance, Engineering & Plant Support ML20248C3611998-05-27027 May 1998 Notice of Violation from Insp on 980315-0425.Violation Noted:Instrument & Control Technicians Failed to Implement Procedure SO123-II-9-3 1999-08-27
[Table view] |
Text
._ _ . . - .. . . _ . _ _ _ . . _ . _ - _ . _ _ . . _ _ _ _ . _ - _ _ . . . _ _ . . _ _ _
. .
,
,
.
ENCLOSURE )
U.S. NUCLEAR REGULATORY COMMISSION
REGION IV
Docket Nos.: 50-361 50-362 License Nos.: NPF-10 NPF-15 Report No.: 50-361/98-15 50-362/98-15 Licensee: Southern California Edison C Facility: San Onofre Nuclear Generating Station, Units 2 and 3 Location: 5000 S. Pacific Coast Hw San Clemente, California Dates: August 24-28,1998 Inspector: A. Bruce Earnest, Physical Security Specialist
' Approved By: Blaine Murray, Chief, Plant Support Branch Attachment: Supplemental Information i
i I
I l
!
l l
l ...
,
9809300325 900925 9 PDR ADOCK 05000361:
I G PDR;j i
-.- ,
._ _ _ __ . . .. . . . _ _ - .
. _ _ - _ _ _ _ _ .
.
EXECUTIVE SUMMARY San Onofre Nuclear Generating Station, Units 2 and 3 NRC Inspection Report 50-361/98-15; 50-362/98-15 This routine, announced inspection focused on the licensee physical security program. The areas inspected included review of access control of personnel, packages, and vehicles, protected area barriers, protected area detection aids, testing and maintenance, and assessment aid Plant Succort
Personnel access to the protected area was efficiently controlled (Section S1.1).
-
Package and material access to the protected area was efficiently controlled (Section S1.2).
- Vehicle access control to the protected area was efficiently controlled (Section S1.3).
,
The protected area physical barriers were adequate to ensure a potential adversary would be delayed in accessing the protected area (Section S2.1).
- Some zones failed during performance tests of protected area detection aids (Section S2.2).
An efficient and well documented test and maintenance program was implemented (Section S2.3).
The assessment aids system provided adequate assessrnent of the perimeter detection zones (Section S2.4).
.
I
!
}
l-
- _ . .- - - - . - . . .- , . . . -.
.
'
.
i
!
3-Report Details JV. Plant Support S1 Conduct of Security and Safeguards Activities S Access Control - Personnel I inspection Scoce )
The personnel access control program was inspected to determine compliance with the requirements of 10 CFR 73.55(d)(1), (2), (3), (5), (6), and (7), and the physical security 1 pla I l Observations and Findinas I I
'
The inspector observed that personnel access to the protected area was efficiently controlled. The protected area access control equipment was functional and well maintained. The last control area for access to the plant was contained within a bullet resistant enclosur The inspector observed numerous tests of the access control metal detectors. The tests properly challenged equipment performance. The security officers manning the access control lanes were knowledgeable of all access control procedural requirements and demonstrated that knowledge when questioned by the inspecto Conclusion Personnel access to the protected area was effectively controlle S Access Control - Packaaes Insoection Scoce The package access control program was inspected to determine compliance with the requirements of 10 CFR 73.55 (d)(3) and the physical security pla . Observations and Findinas The inspector observed the searching of packages and materials at the personnel access control points. The package and material search process was effective. Tests documented that the X-ray equipment performed in a proper manner. The security officers operating the equipment appeared to be well-trained and promptly and completely answered all the inspector's question Conclusion l Package and material access to the protected area was effectively controlled.
!
.__ _ __ _ _ _ _ __ _ _ _ . _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ . _ _ ___
.
.
1 S2.3 Access Control- Vehicles ; Inspection Scope The vehicle access control program was inspected to determine compliance with the requirements of 10 CFR 73.55 (d)(4) and the physical security plan.
Observations and Findinas
' l The inspector observed a search of two trucks outside the vehicle barrier system. The ,
l security officer conducted the search in compliance with their procedural requirement The inspector noted that the security officer conducting the searches was simultaneously conducting training for temporary contract security officers dunng the
,
search. The security officer was very knowledgeable of the procedural requiremen's t l and appeared to give a comprehensive training session.
i
' Conclusion l Vehicle access control to the protected area was effectively controlle S2 Status of Security Facilities and Equipment S Physical Barriers - Protected Area
, Inspection Scope The protected area physical barriers were inspected to determine compliance with the requirements of 10 CFR 73.2,73.5S(c)(1) through (3) and the physical security pla i Observations and Findinas The inspector walked down the protected area physical barriers and determined that the installed barriers would adequately delay penetration of the protected area. Except as noted in the physical security plan, the protected area barriers were separated from vital area barriers by at least 50 feet. Isolation zones were maintained for 20 feet on each i
'
side of the protected area barrier or were described in the physical security plan. The isolation zones were free of obstructions that would allow an intruder to hide from 1 l
assessment by cameras or response personnel. The inspector confirmed that the l perimeter barrier was constructed of at least 11-gauge wire and was at least 8-feet high including the top guard.
! Conclusion
!
l The protected area physical barriers were adequate to ensure a potential adversar/
I would be delayed in an attempt to access the protected area.
i
!
!
!
'
5-S Detection Aids - Protected Area l Insoection Scoce The detection aids program for the protected area was inspected to determine compliance with the requirements of 10 CFR 73.55(c)(4), (e)(2) and (3) and the requirements of the physical security plan. The areas inspected included the detection l systems' capabilities, zoning of the alarm systems, detection system security, and l maintenance of the detection aids syste Observations and Findinas Performance tests were conducted c' the protected area microwave, E-field, and l infrared detection system i On August 27,1998, tests of the protected area detection system identified two i separate protected area detection zones where attempted penetration of the zones was j not initially detected. Another zone was inoperable for its entire length (approximately l 50 yards). The test results indicated that the alarm system was not maintained operable in those locations. Further, two zones were discovered that were vulnerable to defeat, but tests were not completed due to safety restrictions. The operable condition of the protected area detection aids is an inspection followup item pending further testing of l the detection system during a future inspection (50-361;-362/9815-01). The licensee I was conducting a root cause analysis to determine the cause of the entire zone failure, and plans were being discussed to remove the vulnerabilities to the two zones identified as vulnerable to defeat. Compensatory measures were immediately poste Conclusion Some zones failed during performance testing of protected area detection aid l S2.3 Testina and Maintenance i Inspection Scope l The testing and maintenance programs were inspected to determine compliance with the requirements of 10 CFR 73.55(a), (g)(1) through (3), and the physical security pla Observations and Findinas
The inspector reviewed testing and maintenance records and confirmed that the records required in the physical security plan were on file, well documented, and readily available for review. The licensee provided instrumentation and controls technicians to repair or replace any security equipment that required corrective maintenance. The inspector determined through a review of work records and interviews with security officeis and supervisors that repairs were completed in a timely manner with the exception of one protected area camera. The delay in repair of the camera was in excess of 1 month and was attributed to safety concerns. The camera was located on the side of a building that could not be safely reached until a special safety harness was
- . - - _ . . - - _ - - _ - . _ . . - - - . .
l l
l
.
'-
6-l designed and constructed. A proper quarterly preventive maintenance program was in l place for the security systems.
I The inspector observed the testing of several security systems during the inspectio The security officers performing the tests were knowledgeable of testing requirements and techniques. The tests observed by the inspector were performed in a proper
,
manner.
!
j Conclusion l An effective and well documented test and maintenance program was implemented.
l S2.4 Assessment Aids
! Inspection Scope The assessment aids program was inspected to determine compliance with l '10 CFR 73.55 (h)(4) and (6) and the physical security plan. The areas inspected j included the application of closed-circuit television to provide observation of the perimeter isolation zones, adequacy of the monitoring system in the alarm stations, and ,
[ the effectiveness of the guard towers.
!' Observations and Findinas l The inspector observed tests of the closed-circuit television system and determined that
[ it was a adequate. system when combined with the manned guard towers. The
- closed-circuit television cameras were used primarily to enhance guard tower
! assessment capabilities. The alarm station monitors were positioned to facilitate
! assessment by operator Conclusion i The assessment aids system provided adequate assessment of the perimeter detection l- zones.
l V. Manaaement Meetinas X1 Exit Meeting Summary The inspector presented the inspection results to members of licensee management at the conclusion of the inspection on August 28,1998. The licensee acknowledged the l findings presented. No proprietary information was identified.
,
._ _ _ -
-_ _
.
j l
. l i
ATTACHMENT l I
SUPPLEMENTAL INFORMATION I PARTIAL LIST OF PERSONS CONTACTED Licensee R. Krieger, Vice President, Nuclear Generation D. Nunn, Vice President, Engineering & Technical Services R. Borden, Supervisor, Nuclear Oversight G. Broussard, Supervisor, Security Operations )
' M. Flannery, Access Authorization Supervisor
'
T. Frey, Compliance Coordinator G. Gibson, Manager, Compliance M. Gratz, Maintenance R. Jones, Supervisor, Security Systems M. McBreaty, Compliance Engineer G. Plumlee, Supervisor, Compliance J. Rainsberry, Licensing Manager K. Slagle, Manager, Nuclear Oversight J. Wallace, Manager, Site Security M. Wharton, Manager, Engineering Design NRC J. Sloan, Senior Resident inspector INSPECDON PROCEDURES USED 81700 Physical Security Program for Power Reactors ITEMS OPENED, CLOSED, AND DISCUSSED Opened 50-361;-362/9815-01 IFl Protected Area Detection Aids l
a I
i
!
!
. . . _ . . .= . . . . - . . . .
.
.
( LIST OF DOCUMENTS REVIEWED Physical Security Plan, Revision 58
. .
Security Procedure SO123-IV-5.1, Protected and Vital Area Access '
Security Procedure SO123-IV 4.4, Security Lock and Key Contro !
l Access Authorization Procedure SO123-XXIll-4.2, Personnel Screening Programs for 1-Unescorted Access 2 Access Authorization Procedure SO123-XXIll-4.3, Screening Deficiencies Affecting Unescorted Access and Access to Safeguards Information j l
Security System Maintenance Work Requests,1998 )
l
'