Health Physics Sample Records Sample ID: 142458 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140529BD 21 STARYARD SURVEY PT 21 ICommonl Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority:

Contact:

COOPER, TERRY L Survey No:

Reference ID: Accounting Subcode: Unknown Mat: Hazardous Mat:

Comments:

Reviewed: DYNES, WILLIAM J Date: 06/04/14 07:20 Comments:

Origin ]

Mat. SizeNolume: 2037 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00

Description:

STARYARD SURVEY PT 21 Collection I Sample Tech: DYNES, WILLIAM J Sample Date: 05/29/1411:55 Count Time: 900 (secs.)

Tritium Req: No Sample SizeNolume: 2037 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA I RLSSS Exempt: No Evaluated: No Chem Notification: No State Permit:

Offsite Analysis: No Effluent Permit:

Container Surveyed: Cleared For Release: Yes Container Evaluated: Form 212 Ready: Iv" Location Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:

Stored By:, Date: 00/00/00 00:00 Sample Loe:

Other:

Material Loe:

06/18/201413:51 Page 1 of 3

Health Physics Sample Records Sample ID: 142458 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140529BD 21 STARYARD SURVEY PT 21 I Analysis I Geometry MCA ID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date A_1L_marinelli_sand_ 30360 2037GR .000 PARK, MICHAEL C 06/05/14 15:33 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.00001382 1.37E-6 86.480% 40 0 TL-208 NT 3.592E-7 6.47E-8 r 2.248% 208 0 PB-212 NT 5.037E-7 8.96E-8 r 3.152% 212 0 Bl-214 NT 6.376E-7 1.147E-7 r 3.990% 214 0 PB-214 NT 6.6E-7 2.308E-7 r 4.130% 214 0 BE-7 AP 4.9206E-7 Iv 0.000% 7 0 MN-54 AP 1.274E-7 Iv 0.000% 54 0 MN-56 AP 8.9274E-8 Iv 0.000% 56 0 C0-57 AP 8.7899E-8 Iv 0.000% 57 0 C0-58 AP 1.2804E-7 Iv 0.000% 58 0 C0-60 AP 3.6312E-8 Iv 0.000% 60 0 SB-124 AP 6.4217E-8 Iv 0.000% 124 0 SB-125 FP 2.4123E-7 Iv 0.000% 125 0 CS-134 FP 7.5032E-8 Iv 0.000% 134 0 CS-137 FP 1.3669E-7 Iv 0.000% 137

, -Analysis Review I Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/10/1413:24 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:

Comments:

06/18/2014 13:51 Page 2 of3

Health Physics Sample Records Sample ID: 142458 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140529BD 21 STARYARD SURVEY PT 21

[ Review/Approve I HP Review Reviewed: COOPER, TERRY L Date: 06/10/14 13:25 Comments: 338 keV peak is Ac-228 Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:

Final Approval Approved: COOPER, TERRY L Date: 06/10/14 13:25 Comments:

06/18/2014 13:51 Page 3 of 3

                                                                                                  • *******************~***********
  • SONGS HEALTH PHYSICS REPORT 5-JUN-2014 15:30 *
  • >>>>> SAMPLE PARAMETERS<<<<< *
  • Title 140529BD 21 STARYARD SURVEY PT 21 *
  • ID 30360 Acquisition date: 5-JUN-2014 15:27:19. *
  • Start Time: 5-JUN-2014 15:27:00. *
  • Stop Time: 5-JUN-2014 15:27:00. Counting System U2GSP *
  • Quantity 2.03700E+03 GR IHPS Sample Number: 142458 *
  • Geometry A lL marinelli_sand_l Analysis Library HP NATURAL *
  • Operator: MICHAEL PARK *
  • >>>>> A #41-TP11679B PARAMETERS<<<<< *
  • Elapsed Live Time 0 00:03:00.40 Calibration 5-JUN-2014 08:09: *
  • Elapsed Real Time 0 00:03:00.47 Energy Offset 2.12659E-01 *
  • Deadtime 0.0% Energy Slope 4.99528E-01 *
  • Activity Mult Factor: l.OOOOOE+OO Energy Tolerance: 1. 00000 *
  • Half Life Ratio 8.00000 Sensitivity 5.00000
  • Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1 77 .13 30 58 1. 52 153.98 151 8 48.1 8.71E-01 BI-214 PB-212 PB-214 1 87.12 28 22 1. 03 173.97 172 6 31. 3 3.32E+OO PB-212 PB-214 1 238.54 62 26 1. 33 477.11 473 8 17.8 5.04E+OO PB-212 1 295.09 30 20 1. 76 590.30 585 13 35.0 8.78E-Ol PB-214 1 338.44 18 5 1. 75 677.09 67 4 9 30.9 l.12E+OO 1 352.01 46 10 1.12 704.27 700 8 19.3 l.31E+OO PB-214 1 583.35 32 0 1. 92 1167.37 1162 10 18.0 7.83E-01 TL-208 1 609.04 41 3 1. 44 1218.80 1214 11 18.0 3.15E-01 BI-214 1 1460.74 107 0 2.12 2923.83 2918 12 9.9 1.24E+OO K-40

Summary of Nuclide Activity Page : 2 Sample ID : 30360 Acquisition date 5-JUN-2014 15:27:19 Total number of lines in spectrum 9 Number of unidentified lines 0 Number of lines tentatively identified by NID 9 100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 1.28E+09Y 1. 00 l.382E-05 l.382E-05 0.137E-05 9.89 A TL-208 3.05M 1. 49 2.418E-07 3.592E-07 0.647E-07 18.02 A PB-212 10.64H 1. 00 5.027E-07 5.037E-07 0.896E-07 17.80 A BI-214 19.90M 1. 07 5.985E-07 6.376E-07 1. 14 7E-07 17.99 A PB-214 26. SOM 1. 05 6.297E-07 6.600E-07 2.308E-07 34.97 A Total Activity 1.579E-05 l.598E-05 Grand Total Activity : 1.579E-05 1.598E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit

Unidentified Energy Lines Page : 3 Sample ID : 30360 Acquisition date : 5-JUN-2014 15:27:19 It Energy Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err %Eff Flags 1 338.44 18 5 1. 75 677.09 674 9 l.02E-01 30.9 l.70E+OO T Flags: "T" = Tentatively associated

Interference Report Page : 4 Sample ID : 30360 Acquisition date 5-JUN-2014 15:27:19 No interference correction performed

Nuclide Line Activity Report Page : 5 Sample ID : 30360 Acquisition date 5-JUN-2014 15:27:19 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 107 10.67* 5.314E-01 l.382E-05 1.382E-05 9.89 TL-208 72.80 ------ 2.14 1. 594E+OO ------ Line Not Found ------

74.97 ------ 3.60 l.692E+OO ------ Line Not Found ------

84.79 ------ 1. 27 2.058E+OO ------ Line Not Found ------

252.45 ------ 0.80 2. 021E+OO ------ Line Not Found ------

277.28 ------ 6.80 l.920E+OO ------ Line Not Found ------

510.61 ------ 21.60 1.265E+OO ------ Line Not Found ------

583.02 32 86.00* 1.128E+OO 2.418E-07 3.592E-07 18.02 763.06 ------ 1. 64 8.744E-01 ------ Line Not Found ------

860.30 ------ 12.00 7.770E-01 ------ Line Not Found ------

PB-212 74.81 ------ 10.50 1. 685E+OO ------ Line Not Found ------

77 .11 30 17.70 1. 783E+OO 7.008E-07 7.022E-07 48.07 87.19 28 6.27 2.127E+OO l.562E-06 1.565E-06 31. 29 90.13 ------ 1. 86 2.206E+OO ------ Line Not Found ------

115. 12 ------ 0.59 2.535E+OO ------ Line Not Found ------

238.58 62 43.60* 2.083E+OO 5.027E-07 5.037E-07 17.80 300.03 ------ 3.34 l.834E+OO ------ Line Not Found ------

BI-214 76.86 30 0.58 1.783E+OO 2.139E-05 2. 278E-05 48.07 79.29 ------ 0.97 1.869E+OO ------ Line Not Found ------

609.31 41 46.10* l.084E+OO 5.985E-07 6.376E-07 17.99 665.44 ------ 1. 56 9.985E-01 ------ Line Not Found ------

768.35 ------ 4.88 8.685E-01 ------ Line Not Found ------

806.16 ------ 1. 23 8.283E-01 ------ Line Not Found ------

934.04 ------ 3.16 7.177E-01 ------ Line Not Found ------

1120.27 ------ 15.00 6.114E-01 ------ Line Not Found ------

1155. 18 ------ 1. 69 5.973E-01 ------ Line Not Found ------

1238 .11 ------ 5.92 5.697E-01 ------ Line Not Found ------

1280.95 ------ 1. 47 5.585E-01 ------ Line Not Found ------

1377.66 ------ 4.02 5.401E-01 ------ Line Not Found ------

1385.30 ------ 0.78 5. 391E-01 ------ Line Not Found ------

1401.48 ------ 1. 39 5.370E-01 ------ Line Not Found ------

1407.97 ------ 2.48 5.362E-01 ------ Line Not Found ------

1509.22 ------ 2.19 5.292E-01 ------ Line Not Found ------

1583.22 ------ 0. 72 5.296E-01 ------ Line Not Found ------

1661. 26 ------ 1.15 5.351E-01 ------ Line Not Found ------

1729.58 ------ 3.05 5.442E-01 ------ Line Not Found ------

1764.49 ------ 15.90 5.503E-01 ------ Line Not Found ------

1847.41 ------ 2.12 5.694E-01 ------ Line Not Found ------

PB-214 53.17 ------ 1.10 5.543E-01 ------ Line Not Found ------

74.81 ------ 6.52 1.685E+OO ------ Line Not Found ------

77 .11 30 11. 00 1. 783E+OO 1.128E-06 1.182E-06 48.07 87.19 28 3.88 2.127E+OO 2.524E-06 2.646E-06 31. 29 90.13 ------ 1.15 2.206E+OO ------ Line Not Found ------

241. 92 ------ 7.46 2.067E+OO ------ Line Not Found ------

258.94 ------ 0.55 1.994E+OO ------ Line Not Found ------

295.09 30 19.20* l.852E+OO 6.297E-07 6.600E-07 34.97 351. 87 46 37.10 1.662E+OO 5.472E-07 5.735E-07 19.26 785.83 ------ 1. 09 8.495E-01 ------ Line Not Found ------

839.00 --*---- 0.59 7. 964E-01 ------ Line Not Found ------

Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30360 Acquisition date 5-JUN-2014 15:27:19 Flag: "*" Keyline

Minimum Detectable Activity Report Page : 7 Sample ID 30360 Acquisition date 5-JUN-2014 15:27:19 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)

BE-7 2. 477.61 4.9206E-07 MN-54 6. 834.83 l.2740E-07 MN-56 2. 846.81 8.9274E-08 C0-57 25. 122.06 8.7899E-08 C0-58 6. 810.79 1. 2804E-07 C0-60 0. 1332.50 3.6312E-08 SB-124 2. 602.73 6.4217E-08 SB-125 6. 427.88 2.4123E-07 CS-134 3. 604. 71 7.5032E-08 CS-137 8. 661. 66 1.3669E-07