ML20034E259
Text
Health Physics Sample Records Sample ID: 142465 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140529BD 02 STARYARD SURVEY PT 35 lcommon1 Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N
Contact:
COOPER, TERRY L Survey No:
Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments:
Reviewed: DYNES, WILLIAM J Date: 06/04/14 08:01 Comments:
I Ori9l!!J Mat. SizeNolume: 2060 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
STARYARD SURVEY PT 35 Collection Sample Tech: DYNES, WILLIAM J Sample Date: 05/30/14 07:45 Count Time: 900 (secs.)
Tritium Req: No Sample SizeNolume: 2060 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA RLSSS Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: ~
!Location!
Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:
Stored By:, Date: 00/00/00 00:00 Sample Loe:
Other:
Material Loe:
06/18/201414:02 Page 1 of3
Health Physics Sample Records Sample ID: 142465 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized:
Description:
140529BD 02 STARYARD SURVEY PT 35
!Analysis I Geometry MCAID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date C_1L_marinelli_sand_ 30356 2060GR .000 PARK, MICHAEL C 06/05/14 14:33 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 8.856E-6 1.061E-6 r 80.295% 40 0 TL-208 NT 2.663E-7 5.18E-8 r 2.414% 208 0 PB-212 NT 5.598E-7 7.62E-8 r 5.076% 212 0 Bl-214 NT 3.173E-7 7.17E-8 r 2.877% 214 0 PB-214 NT 4.915E-7 1.511E-7 r 4.456% 214 0 AC-228 NT 5.384E-7 1.577E-7 r 4.882% 228 0 BE-7 AP 5.4377E-7 iv- 0.000% 7 0 MN-54 AP 1.0564E-7 w 0.000% 54 0 MN-56 AP 1.1039E-7 iv- 0.000% 56 0 C0-57 AP 7.3047E-8 w 0.000% 57 0 C0-58 AP 6.3912E-8 ~ 0.000% 58 0 C0-60 AP 3.2562E-8 iv- 0.000% 60 0 SB-124 AP 6.8643E-8 w 0.000% 124 0 SB-125 FP 1.8795E-7 w 0.000% 125 0 CS-134 FP 6.549E-8 ~ 0.000% 134 0 CS-137 FP 1.143E-7 ~ 0.000% 137 Analysis Review Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/10/1413:34 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments:
06/18/2014 14:02 Page 2 of 3
Health Physics Sample Records Sample ID: 142465 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140529BD 02 STARYARD SURVEY PT 35 I Review/Approve I HP Eng_ Review Reviewed: COOPER, TERRY L Date: 06/10/14 13:34 Comments:
Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:
Final Approval Approved: COOPER, TERRY L Date: 06/10/1413:35 Comments:
06/18/201414:02 Page 3 of 3
- SONGS HEALTH PHYSICS REPORT 5-JUN-2014 14:30 *
- >>>>> SAMPLE PARAMETERS<<<<< *
- Title 1405298D 02 STARYARD SURVEY PT 35 *
- ID 30356 Acquisition date: 5-JUN-2014 14:27:02. *
- Start Time: 5-JUN-2014 14:27:00. *
- Stop Time: 5-JUN-2014 14:27:00. Counting System U2GSP *
- Quantity 2.06000E+03 GR IHPS Sample Number: 142465 *
- Geometry C lL marinelli_sand_l Analysis Library HP NATURAL *
- Operator: MICHAEL PARK *
- >>>>> C #41-TP11750A PARAMETERS<<<<< *
- Elapsed Live Time 0 00:03:00.47 Calibration 5-JUN-2014 08:14: *
- Elapsed Real Time 0 00:03:00.52 Energy Offset -1.39807E-01 *
- Deadtime 0.0% Energy Slope 4.99820E-01 *
- Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1. 00000 *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 238.61 69 6 1.19 477.65 474 8 13.6 5.86E-01 PB-212 1 242.22 25 5 1. 83 484.87 482 7 24.3 4.81E-01 PB-214 1 295.59 23 8 1. 79 591.63 586 10 30.7 8.28E-01 PB-214 1 351. 77 49 6 1. 45 704.02 700 9 17.3 4.78E-01 PB-214 l 583.17 26 0 2.09 1166. 92 1163 8* 19. 5 l.57E+OO TL-208 1 609.30 21 0 1. 4 9 1219.17 1215 9 22.6 7.08E-01 BI-214 1 911.22 16 2 1. 77 1823.07 1819 9 29.3 6. 21E-01 AC-228 1 1460.96 72 0 1. 76 2922.44 2917 11 12. 0 8.76E-01 K-40
Summary of Nuclide Activity Page : 2 Sample ID : 30356 Acquisition date 5-JUN-2014 14:27:02 Total number of lines in spectrum 8 Number of unidentified lines 0 Number of lines tentatively identified by NID 8 100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 l.28E+09Y 1. 00 8.856E-06 8.856E-06 1.061E-06 11. 98 A TL-208 3.05M 1. 39 l.914E-07 2.663E-07 0.518E-07 19.46 A PB-212 10.64H 1. 00 5.589E-07 5.598E-07 0. 7 62E-07 13.62 A BI-214 19.90M 1. 05 3.009E-07 3.173E-07 0.717E-07 22.61 A PB-214 26.SOM 1. 04 4. 724E-07 4.915E-07 1. 511E-07 30.75 A AC-228 6.13H 1. 00 5.368E-07 5.384E-07 l.577E-07 29.30 A Total Activity 1.092E-05 1.103E-05 Grand Total Activity : 1.092E-05 1.103E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit
Unidentified Energy Lines Page : 3 Sample ID : 30356 Acquisition date 5-JUN-2014 14:27:02 None Flags: "T" Tentatively associated
Interference Report Page : 4 Sample ID : 30356 Acquisition date 5-JUN-2014 14:27:02 No interference correction performed
Nuclide Line Activity Report Page : 5 Sample ID : 30356 Acquisition date 5-JUN-2014 14:27:02 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 72 10.67* 5.560E-01 8.856E-06 8.856E-06 11. 98 TL-208 72.80 ------ 2.14 1.486E+OO ------ Line Not Found ------
74.97 ------ 3.60 l.577E+OO ------ Line Not Found ------
84.79 ------ 1. 27 1.917E+OO ------ Line Not Found ------
252.45 ------ 0.80 2.004E+OO ------ Line Not Found ------
277.28 ------ 6.80 1. 917E+OO ------ Line Not Found ------
510.61 ------ 21. 60 1.298E+OO ------ Line Not Found ------
583.02 26 86.00* 1.157E+OO 1. 914E-07 2.663E-07 19.46 763.06 ------ 1. 64 8.934E-01 ------ Line Not Found ------
860.30 ------ 12.00 7.922E-01 ------ Line Not Found ------
PB-212 74.81 ------ 10.50 1.570E+OO ------ Line Not Found ------
77 .11 ------ 17.70 l.661E+OO ------ Line Not Found ------
87.19 ------ 6.27 1.983E+OO ------ Line Not Found ------
90.13 ------ 1. 86 2.055E+OO ------ Line Not Found ------
115. 12 ------ 0.59 2.376E+OO ------ Line Not Found ------
238.58 69 43.60* 2.055E+OO 5.589E-07 5.598E-07 13.62 300.03 ------ 3.34 1.843E+OO ------ Line Not Found ------
BI-214 76.86 ------ 0.58 1.651E+OO ------ Line Not Found ------
79.29 ------ 0.97 1.741E+OO ------ Line Not Found ------
609.31 21 46.10* 1. 112E+OO 3.009E-07 3.173E-07 22.61 665.44 ------ 1. 56 1.023E+OO ------ Line Not Found ------
768.35 ------ 4.88 8.873E-01 ------ Line Not Found ------
806.16 ------ 1. 23 8.454E-Ol ------ Line Not Found ------
934.04 ------ 3.16 7.310E-01 ------ Line Not Found ------
1120. 27 ------ 15.00 6.242E-01 ------ Line Not Found ------
1155. 18 ------ 1. 69 6.105E-01 ------ Line Not Found ------
1238. 11 ------ 5.92 5.846E-01 ------ Line Not Found ------
1280.95 ------ 1. 4 7 5.747E-01 ------ Line Not Found ------
1377. 66 ------ 4.02 5.602E-01 ------ Line Not Found ------
1385. 30 ------ 0.78 5.595E-01 ------ Line Not Found ------
1401.48 ------ 1. 39 5.583E-01 ------ Line Not Found ------
1407.97 ------ 2.48 5.578E-01 ------ Line Not Found ------
1509.22 ------ 2.19 5.568E-01 ------ Line Not Found ------
1583.22 ------ 0. 72 5.628E-01 ------ Line Not Found ------
1661. 26 ------ 1.15 5.753E-01 ------ Line Not Found ------
1729.58 ------ 3.05 5.918E-01 ------ Li.ne Not Found ------
1764.49 ------ 15.90 6.023E-01 ------ Line Not Found ------
1847.41 ------ 2.12 6. 331E-01 ------ Line Not Found ------
PB-214 53.17 ------ 1.10 5.203E-01 ------ Line Not Found ------
74.81 ------ 6.52 1.570E+OO ------ Line Not Found ------
77 .11 ------ 11. 00 1.661E+OO ------ Line Not Found ------
87.19 ------ 3.88 1.983E+OO ------ Line Not Found ------
90.13 ------ 1.15 2.055E+OO ------ Line Not Found ------
241. 92 25 7.46 2.042E+OO 1.184E-06 l.232E-06 24.25 258.94 ------ 0.55 l.981E+OO ------ Line Not Found ------
295.09 23 19.20* 1.857E+OO 4.724E-07 4.915E-07 30.75 351.87 49 37.10 1.686E+OO 5.674E-07 5.903E-07 17.28 785.83 ------ 1. 09 8.674E-01 ------ Line Not Found ------
839.00 ------ 0.59 8.122E-01 ------ Line Not Found ------
Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30356 Acquisition date 5-,JUN-2014 14:27:02 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error AC-228 89.96 ------ 3.40 2.051E+OO ------ Line Not Found ------
93.35 ------ 5.60 2.124E+OO ------ Line Not Found ------
99.55 ------ 1. 30 2.229E+OO Line Not Found ------
105.36 ------ 2.00 2.301E+OO ------ Line Not Found ------
108.99 ------ 0.67 2.335E+OO ------ Line Not Found ------
129.03 ------ 2.90 2.414E+OO ------ Line Not Found ------
153.89 ------ 0.84 2.377E+OO ------ Line Not Found ------
209.39 ------ 4.10 2.168E+OO ------ Line Not Found ------
216.24 ------ 0.80 2.141E+OO ------ Line Not Found ------
270.26 ------ 3.80 1.941E+OO ------ Line Not Found ------
328.07 ------ 3.50 1.756E+OO ------ Line Not Found ------
338.42 ------ 12.40 1. 725E+OO ------ Line Not Found ------
340.94 ------ 0.52 1. 718E+OO ------ Line Not Found ------
409.62 ------ 2.20 1. 531E+OO ------ Line Not Found ------
463.10 ------ 4.60 1. 401E+OO ------ Line Not Found ------
562.65 ------ 1. 01 l.195E+OO ------ Line Not Found ------
581.52 ------ 3.00 l.160E+OO ------ Line Not Found ------
726.63 ------ 0.87 9.382E-01 ------ Line Not Found ------
755.28 ------ 1. 32 9.027E-01 ------ Line Not Found ------
772. 28 ------ 1. 09 8.827E-01 ------ Line Not Found ------
782.12 ------ 0.59 8.716E-01 ------ Line Not Found ------
794.79 ------ 4.60 8.576E-01 ------ Line Not Found ------
830.59 ------ 0.63 8.205E-01 ------ Line Not Found ------
835.60 ------ 1. 71 8.155E-01 Line Not Found ------
840.44 ------ 0.94 8.108E-01 ------ Line Not Found ------
904.29 ------ 0.89 7.542E-01 ------ Line Not Found ------
911.16 16 29.00* 7.486E-01 5.368E-07 5.384E-07 29.30 964. 64 ------ 5.80 7. 091E-01 ------ Line Not Found ------
968. 97 ------ 17.40 7.061E-01 ------ Line Not Found ------
1246.60 ------ 0.57 5.825E-01 ------ Line Not Found ------
1459.19 ------ 1. 06 5.560E-01 ------ Line Not Found ------
1496.00 ------ 1. 05 5.563E-01 ------ Line Not Found ------
1501. 44 ------ 0.58 5.565E-01 ------ Line Not Found ------
1580.30 ------ 0. 71 5.624E-01 ------ Line Not Found ------
1588.23 ------ 3.60 5.634E-01 ------ Line Not Found ------
1630.47 ------ 1. 95 5. 696E-01 ------ Line Not Found ------
1638.10 ------ 0.54 5.709E-01 ------ Line Not Found ------
Flag: "*" = Keyline
Minimum Detectable Activity Report Page : 7 Sample ID 30356 Acquisition date 5-JUN-2014 14:27:02 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)
BE-7 3. 477.61 5.4377E-07 MN-54 4. 834.83 1.0564E-07 MN-56 4. 846.81 1.1039E-07 C0-57 15. 122.06 7.3047E-08 C0-58 1. 810.79 6.3912E-08 C0-60 0. 1173.24 3.2562E-08 SB-124 3. 602.73 6.8643E-08 SB-125 3. 427.88 l.8795E-07 CS-134 2. 604. 71 6.5490E-08 CS-137 6. 661. 66 l.1430E-07