Health Physics Sample Records Sample ID: 142442 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140528BD 12 STAR 12-20 Dirt Sample Common Resp Org: P4000 - PROJECT MANAGEMEf Cross Ref Sample ID: Priority: N

Contact:

COOPER, TERRY L Survey No:

Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 05/30/14 08:07 Comments:

1arig1nl Mat. SizeNolume: 1589 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00

Description:

STAR 12 SOIL SAMPLE I Collection Sample Tech: DYNES, WILLIAM J Sample Date: 05/29/14 07:17 Count Time: 900 (secs.)

Tritium Req: No Sample SizeNolume: 1589 GRAMS Instructions:

Comments: COUNT TO MDA

[Kt,_sss l Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: ~

l.b.Q_cation Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: 3" (in.) Equip ID:

Stored By:, Date: 00/00/00 00:00 Sample Loe:

Other:

Material Loe:

06/18/2014 12:13 Page 1 of 3

Health Physics Sample Records Sample ID: 142442 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140528BD 12 STAR 12-20 Dirt Sample jAnalysisl Geometry MCAID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date B_1L_marinelli_sand_ 30279 1589GR .000 HENDERSON, JOE C 05/30/14 12:48 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.000010951.51E-6 r 77.728% 40 0 TL-208 NT 4.293E-7 9.79E-8 r 3.047% 208 0 PB-212 NT 5.279E-7 1.277E-7 r 3.747% 212 0 Bl-214 NT 6.829E-7 1.45E-7 r 4.848% 214 0 PB-214 NT 6.208E-7 2.207E-7 r 4.407% 214 0 AC-228 NT 8.766E-7 2.176E-7 r 6.223% 228 0 BE-7 AP 7.6781E-7 w 0.000% 7 0 MN-54 AP 3.9031E-8 Iv' 0.000% 54 0 MN-56 AP 1.0994E-7 rvr 0.000% 56 0 C0-57 AP 8.2734E-8 !if" 0.000% 57 0 C0-58 AP 1.9876E-7 rvr 0.000% 58 0 C0-60 AP 5.7877E-8 !if" 0.000% 60 0 SB-124 AP 2.9197E-8 0.000% 124 0

0 SB-125 CS-134 FP FP 2.4783E-7 7.0915E-8 w

w

"" 0.000%

0.000%

125 134 0 CS-137 FP 1.4556E-7 w 0.000% 137 Analysis Review I Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/10/14 09:58 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:

Comments:

06/18/2014 12:13 Page 2 of 3

Health Physics Sample Records Sample ID: 142442 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140528BD 12 STAR 12-20 Dirt Sample r Review/Approve-l HP Review Reviewed: COOPER, TERRY L Date: 06/10/14 09:58 Comments:

Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:

Final Approval Approved: COOPER, TERRY L Date: 06/10/14 09:58 Comments:

06/18/2014 12:13 Page 3 of 3

  • SONGS HEALTH PHYSICS REPORT 30-MAY-2014 12:46 *
  • >>>>> SAMPLE PARAMETERS<<<<< *
  • Title 110528BD 12 STAR 12-20 DIRT SAMPLE *
  • ID 30279 Acquisition date: 30-MAY-2014 12:43:46 *
  • Start Time: 30-MAY-2014 12:43:00 *
  • Stop Time: 30-MAY-2014 12:43:00 Counting System U2GSP *
  • Quantity 1. 58900E+03 GR IHPS Sample Number: 142442 *
  • Geometry B lL marinelli sand 1 Analysis Library HP NATURAL *
  • Operator: JOE HENDERSON *
  • >>>>> B #42-TP11663A PARAMETERS<<<<< *
  • Elapsed Live Time 0 00:03:00.45 Calibration 29-MAY-2014 21:44 *
  • Elapsed Real Time 0 00:03:00.48 Energy Offset -l.81343E-02 *
  • Deadtime 0.0% Energy Slope 4.99764E-01 *
  • Activity Mult Factor: l.OOOOOE+OO Energy Tolerance: 1.00000 *
  • Half Life Ratio 8.00000 Sensitivity 5.00000
  • Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 238.65 44 22 1. 39 477.58 473 10 24.2 3.55E+OO PB-212 1 241.78 16 1 1. 20 483.83 482 6 26.9 4. llE-01 PB-214 1 295.54 19 8 2.12 591. 41 585 10 35.6 5.33E-01 PB-214 1 351.98 35 6 1. 7 9 704.34 699 12 23.0 1.03E+OO PB-214 1 583.08 22 0 1. 87 1166. 76 1160 11 22.8 1.07E+OO TL-208 1 609.08 27 3 2.66 1218.79 1214 11 21. 2 7.79E-01 BI-214 1 911. 08 16 0 1. 80 1823.12 1817 10 24.8 4.48E-01 AC-228 1 1460.64 52 0 2.51 2922.84 2916 12 13.8 1. 4 7E+OO K-40

Surrnnary of Nuclide Activity Page : 2 Sample ID : 30279 Acquisition date 30-MAY-2014 12:43:46 Total number ot' lines in spectrum 8 Number of unidentified lines 0 Number of lines tentatively identified by NID 8 100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 1.28E+09Y 1. 00 l.095E-05 1. 095E-05 0.151E-05 13. 81 A TL-208 3.05M 1. 64 2.612E-07 4.293E-07 0.979E-07 22.81 A PB-212 10.64H 1. 00 5.266E-07 5.279E-07 1.277E-07 24.18 A BI-214 19.90M 1. 08 6.312E-07 6.829E-07 l.450E-07 21. 24 A PB-214 26. SOM 1. 06 5.855E-07 6.208E-07 2.207E-07 35.56 A AC-228 6.13H 1. 00 8.728E-07 8.766E-07 2.176E-07 24.82 A Total Activity 1. 383E-05 1. 409E-05 Grand Total Activity : 1. 383E-05 1.409E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit

Unidentified Energy Lines Page : 3 Sample ID : 30279 Acquisition date 30-MAY-2014 12:43:46 None Flags: "T" Tentatively associated

Interference Report Page : 4 Sample ID : 30279 Acquisition date 30-MAY-2014 12:43:46 No interference correction performed

Nuclide Line Activity Report Page : 5 Sample ID : 30279 Acquisition date 30-MAY-2014 12:43:46 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 52 10.67* 4.212E-01 l.095E-05 1.095E-05 13.81 TL-208 72. 80 ------ 2.14 1.070E+OO ------ Line Not Found ------

74.97 ------ 3.60 1.156E+OO ------ Line Not Found ------

84.79 ------ 1. 27 1.506E+OO ------ Line Not Found ------

252.45 ------ 0.80 1.745E+OO ------ Line Not Found ------

277.28 ------ 6.80 1.645E+OO ------ Line Not Found ------

510.61 ------ 21. 60 1.035E+OO ------ Line Not Found ------

583.02 22 86.00* 9.198E-01 2.612E-07 4.293E-07 22.81 763.06 ------ 1. 64 7.126E-01 ------ Line Not Found ------

860.30 ------ 12.00 6.341E-01 ------ Line Not Found ------

PB-212 74.81 ------ 10.50 1.150E+OO ------ Line Not Found ------

77 .11 ------ 17.70 1.239E+OO ------ Line Not Found ------

87.19 ------ 6.27 1.579E+OO ------ Line Not Found ------

90.13 ------ 1. 86 1.662E+OO ------ Line Not Found ------

115 .12 ------ 0.59 2.085E+OO ------ Line Not Found ------

238.58 44 43.60* 1.804E+OO 5.266E-07 5.279E-07 24.18 300.03 ------ 3.34 1.562E+OO ------ Line Not Found ------

BI-214 76.86 ------ 0.58 1.229E+OO ------ Line Not Found ------

79.29 ------ 0.97 1.320E+OO ------ Line Not Found ------

609.31 27 46.10* 8.836E-01 6.312E-07 6.829E-07 21. 24 665.44 ------ 1. 56 8.131E-01 ------ Line Not Found ------

768.35 ------ 4.88 7.078E-01 ------ Line Not Found ------

806.16 ------ 1. 23 6.754E-01 ------ Line Not Found ------

934.04 ------ 3.16 5.861E-01 ------ Line Not Found ------

1120. 27 ------ 15.00 4.982E-01 ------ Line Not Found ------

1155 .18 ------ 1. 69 4.860E-01 ------ Line Not Found ------

1238. 11 ------ 5.92 4.615E-01 ------ Line Not Found ------

1280.95 ------ 1. 47 4.510E-01 ------ Line Not Found ------

1377.66 ------ 4.02 4.323E-01 ------ Line Not Found ------

1385. 30 ------ 0.78 4. 311E-01 ------ Line Not Found ------

1401. 48 ------ 1. 39 4.287E-01 ------ Line Not Found ------

1407.97 ------ 2.48 4.277E-01 ------ Line Not Found ------

1509.22 ------ 2.19 4.165E-01 ------ Line Not Found ------

1583.22 ------ 0. 72 4.120E-01 ------ Line Not Found ------

1661. 26 ------ 1.15 4.103E-01 ------ Line Not Found ------

1729.58 ------ 3.05 4 .114E-01 ------ Line Not Found ------

1764.49 ------ 15.90 4.128E-01 ------ Line Not Found ------

1847.41 ------ 2.12 4.187E-01 ------ Line Not Found ------

PB-214 53.17 ------ 1.10 2.929E-01 ------ Line Not Found ------

74.81 ------ 6.52 1.150E+OO ------ Line Not Found ------

77 .11 ------ 11. 00 1.239E+OO ------ Line Not Found ------

87.19 ------ 3.88 1.579E+OO ------ Line Not Found ------

90.13 ------ 1.15 1.662E+OO ------ Line Not Found ------

241. 92 16 7.46 1. 791E+OO 1.123E-06 1.190E-06 26.85 258.94 ------ 0.55 1.718E+OO ------ Line Not Found ------

295.09 19 19.20* 1.578E+OO 5.855E-07 6.208E-07 35.56 351.87 35 37.10 1.395E+OO 6.397E-07 6.783E-07 22.95 785.83 ------ 1. 09 6.925E-01 ------ Line Not Found ------

839.00 ------ 0.59 6.497E-01 ------ Line Not Found ------

Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30279 Acquisition date 30-MAY-2014 12:43:46 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error AC-228 89. 96 ------ 3.40 1.657E+OO ------ Line Not Found ------

93.35 ------ 5.60 l.743E+OO ------ Line Not Found ------

99.55 ------ 1. 30 l.876E+OO ------ Line Not Found ------

105.36 ------ 2.00 1.973E+OO ------ Line Not Found ------

108.99 ------ 0. 67 2.021E+OO ------ Line Not Found ------

129.03 ------ 2.90 2.163E+OO ------ Line Not Found ------

153.89 ------ 0.84 2.160E+OO ------ Line Not Found ------

209.39 ------ 4.10 1. 937E+OO ------ Line Not Found ------

216.24 ------ 0.80 l.905E+OO ------ Line Not Found ------

270.26 ------ 3.80 1.673E+OO ------ Line Not Found ------

328.07 ------ 3.50 1. 468E+OO ------ Line Not Found ------

338.42 ------ 12.40 1.435E+OO ------ Line Not Found ------

340.94 ------ 0.52 1.428E+OO ------ Line Not Found ------

409.62 ------ 2.20 1.243E+OO ------ Line Not Found ------

463.10 ------ 4. 60 1.125E+OO ------ Line Not Found ------

562.65 ------ 1. 01 9.501E-01 ------ Line Not Found ------

581. 52 ------ 3.00 9.221E-01 ------ Line Not Found ------

72 6. 63 ------ 0.87 7.472E-01 ------ Line Not Found ------

755.28 ------ 1. 32 7.197E-01 ------ Line Not Found ------

772. 28 ------ 1. 09 7.043E-Ol ------ Line Not Found ------

782.12 ------ 0.59 6.956E-01 ------ Line Not Found ------

794.79 ------ 4. 60 6.848E-01 ------ Line Not Found ------

830.59 ------ 0.63 6.561E-01 ------ Line Not Found ------

835.60 ------ 1. 71 6.523E-01 ------ Line Not Found ------

840.44 ------ 0.94 6.486E-01 ------ Line Not Found ------

904.29 ------ 0.89 6.044E-01 ------ Line Not Found ------

911.16 16 29.00* 6.00lE-01 8. 728E-07 8.766E-07 24.82 964. 64 ------ 5.80 5.686E-01 ------ Line Not Found ------

968.97 ------ 17.40 5.663E-01 ------ Line Not Found ------

1246.60 ------ 0.57 4.593E-01 ------ Line Not Found ------

1459.19 ------ 1. 06 4.213E-01 ------ Line Not Found ------

1496.00 ------ 1. 05 4.176E-01 ------ Line Not Found ------

1501. 44 ------ 0.58 4.172E-01 ------ Line Not Found ------

1580.30 ------ 0.71 4.121E-01 ------ Line Not Found ------

1588.23 ------ 3.60 4 .118E-01 ------ Line Not Found ------

1630.47 ------ 1. 95 4.106E-01 ------ Line Not Found ------

1638.10 ------ 0.54 4.105E-01 ------ Line Not Found ------

Flag: "*" = Keyline

Minimum Detectable Activity Report Page : 7 Sample ID 30279 Acquisition date 30-MAY-2014 12:43:46 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)

BE-7 2. 477.61 7.6781E-07 MN-54 0. 834.83 3.9031E-08 MN-56 1. 846.81 1.0994E-07 C0-57 8. 122.06 8.2734E-08 C0-58 6. 810.79 1. 9876E-07 C0-60 0. 1332.50 5.7877E-08 SB-124 0. 602.73 2.9197E-08 SB-125 2. 427.88 2.4783E-07 CS-134 1. 604.71 7.0915E-08 CS-137 3. 661.66 l.4556E-07