ML20034E237
Text
Health Physics Sample Records Sample ID: 142436 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140528BD 07 STAR 7-20 Dirt Sample
!Common]
Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N
Contact:
COOPER, TERRY L Survey No:
Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments:
Reviewed: DYNES, WILLIAM J Date: 05/29/14 11 :21 Comments:
1*-origin l Mat. SizeNolume: 1000 ml Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
STAR 02 SOIL SAMPLE I Collection I Sample Tech: DYNES, WILLIAM J Sample Date: 05/28/1413:07 Count Time: 900 (secs.)
Tritium Req: Sample SizeNolume: 1797 GRAMS Instructions:
Comments: COUNT TO MDA RLSSS Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: ~
ILocation I Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: 3" (in.) Equip ID:
Stored By:, Date: 00/00/00 00:00 Sample Loe:
Other:
Material Loe:
06/18/201411:50 Page 1 of 3
Health Physics Sample Records Sample ID: 142436 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
1405288D 07 STAR 7-20 Dirt Sample
~aly~
Geometry_ _ _ _ MCAID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date A_1L_marinelli_sand- 30269 1797GR .000 ABERNATHY, AGNES B 05/29/14 16:03 Isotope Mode Activit~ Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.00001113 1.4E-6 r 80.245% 40 0 TL-208 NT 1.713E-7 7.65E-8 r 1.235% 208 0 PB-212 NT 5.552E-7 1.29E-7 r 4.003% 212 0 81-214 NT 4.754E-7 1.025E-7 r 3.428% 214 0 PB-214 NT 7.766E-7 1.41E-7 r 5.599% 214 0 AC-228 NT 7.616E-7 1.927E-7 r 5.491% 228 0 BE-7 AP 7.19E-7 Iv 0.000% 7 0 MN-54 AP 1.0786E-7 w 0.000% 54 0 MN-56 AP 7.2016E-8 w 0.000% 56 0 C0-57 AP 7.3632E-8 w 0.000% 57 0 C0-58 AP 9.0871E-8 w 0.000% 58 0 C0-60 AP 1.1196E-7 w 0.000% 60 0 SB-124 AP 2.1042E-8 w 0.000% 124 0 SB-125 FP 2.3439E-7 Iv 0.000% 125 0 CS-134 FP 5.4608E-8 Iv 0.000% 134 0 CS-137 FP 9.0421E-8 Iv 0.000% 137 Analysis Review I Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/10/14 09:46 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments:
06/18/2014 11 :50 Page 2 of 3
Health Physics Sample Records Sample ID: 142436 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized:
Description:
140528BD 07 STAR 7-20 Dirt Sample I Review/AeproveJ HP Review Reviewed: COOPER, TERRY L Date: 06/10/14 09:46 Comments:
Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:
Final Approval Approved: COOPER, TERRY L Date: 06/10/14 09:46 Comments:
06/18/2014 11 :50 Page 3 of3
- SONGS HEALTH PHYSICS REPORT 29-MAY-2014 16:02 *
- >>>>> SAMPLE PARAMETERS<<<<< *
- Title 140528BD 07 STAR 7-20 DIRT SAMPLE *
- ID 30269 Acquisition date: 29-MAY-2014 15:58:52 *
- Start Time: 29-MAY-2014 15:58:00 *
- Stop Time: 29-MAY-2014 15:58:00 Counting System U2GSP *
- Quantity 1.79700E+03 GR IHPS Sample Number: 142436 *
- Geometry A 11 marinelli_sand_l Analysis Library HP NATURAL *
- Operator: AGNES ABERNATHY *
- >>>>> A #41-TP11679B PARAMETERS<<<<< *
- Elapsed Live Time 0 00:03:00.43 Calibration 28-MAY-2014 21:10 *
- Elapsed Real Time 0 00:03:00.48 Energy Offset 2.58874E-01 *
- Deadtime 0.0% Energy Slope 4.99485E-01 *
- Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1.00000 *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 3 74.92 20 19 1. 04 149.48 143 20 42.8 1.19E+OO PB-212 PB-214 TL-208 3 77.19 30 17 1. 05 154.01 143 20 29.2 BI-214 PB-212 PB-214 1 238.82 60 29 1. 4 9 477.61 472 13 23.2 2.85E+OO PB-212 1 2 95. 11 31 0 2.22 590.31 585 10 18.2 9.27E-01 PB-214 1 352.02 35 2 1. 37 704.26 700 9 18.7 4.15E-01 PB-214 1 583.53 12 6 1. 31 1167.76 1163 8 44.7 8.07E-01 TL-208 1 609.36 26 2 1. 28 1219.48 1215 8 21. 6 6.20E-01 BI-214 1 910.99 19 2 2.38 1823.38 1819 9 25.3 4.69E-01 AC-228 1 1460.96 76 3 1. 94 2924.49 2918 13 12.6 4.50E-01 K-40
Summary of Nuclide Activity Page : 2 Sample ID : 30269 Acquisition date 29-MAY-2014 15:58:52 Total number of lines in spectrum 9 Number of unidentified lines 0 Number of lines tentatively identified by NID 9 100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 l.28E+09Y 1. 00 1.113E-05 l.113E-05 0.140E-05 12.57 A TL-208 3.05M 1. 68 1.018E-07 1. 713E-07 0.765E-07 44.69 A PB-212 10.64H 1. 00 5.538E-07 5.552E-07 1.290E-07 23.23 A BI-214 19.90M 1. 09 4.379E-07 4.754E-07 l.025E-07 21. 55 A PB-214 26.80M 1. 06 7.305E-07 7.766E-07 l.410E-07 18.15 A AC-228 6,13H 1. 00 7.582E-07 7.616E-07 1.927E-07 25.30 A Total Activity 1. 371E-05 l.387E-05 Grand Total Activity: 1.371E-05 1.387E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit
Unidentified Energy Lines Page : 3 Sample ID : 30269 Acquisition date 29-MAY-2014 15:58:52 None Flags: "T" Tentatively associated
Interference Report Page : 4 Sample ID : 30269 Acquisition date 29-MAY-2014 15:58:52 No interference correction performed
Nuclide Line Activity Report Page : 5 Sample ID : 30269 Acquisition date 29-MAY-2014 15:58:52 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 76 10.67* 5.314E-01 1. 113E-05 1.113E-05 12.57 TL-208 72. 80 ------ 2.14 l.594E+OO ------ Line Not Found ------*
74.97 20 3.60 1.690E+OO 2.794E-06 4.700E-06 42.76 84.79 ------ 1. 27 2.058E+OO ------ Line Not Found ------
252.45 ------ 0.80 2.021E+OO ------ Line Not Found ------
277.28 ------ 6.80 l.920E+OO ------ Line Not Found ------
510.61 ------ 21. 60 1.265E+OO ------ Line Not Found ------
583.02 12 86.00* 1.127E+OO l.018E-07 1.713E-07 44.69 763.06 ------ 1. 64 8.744E-01 ------ Line Not Found ------
860.30 ------ 12.00 7.770E-01 ------ Line Not Found ------
PB-212 74.81 20 10.50 1. 690E+OO 9.579E-07 9.604E-07 42.76 77 .11 30 17.70 1. 786E+OO 7.814E-07 7.834E-07 29.23 87.19 ------ 6.27 2.129E+OO ------ Line Not Found ------*
90.13 ------ 1. 86 2.206E+OO ------ Line Not Found ------
115 .12 ------ 0.59 2.535E+OO ------ Line Not Found ------
238.58 60 43.60* 2.081E+OO 5.538E-07 5.552E-07 23.23 300.03 ------ 3.34 1.834E+OO ------ Line Not Found ------
BI-214 76.86 30 0.58 1.786E+OO 2.385E-05 2.589E-05 29.23 79.29 ------ 0.97 1.869E+OO ------ Line Not Found ------
609.31 26 46.10* 1.084E+OO 4.379E-07 4.754E-07 21. 55 665.44 ------ 1. 56 9.985E-01 ------ Line Not Found ------
768.35 ------ 4.88 8.685E-01 ------ Line Not Found ------
806.16 ------ 1. 23 8.283E-01 ------ Line Not Found ------
934.04 ------ 3.16 7.177E-01 ------ Line Not Found ------
1120. 27 ------ 15.00 6 .114E-01 ------ Line Not Found ------
1155. 18 ------ 1. 69 5.973E-01 ------ Line Not Found ------
1238 .11 ------ 5.92 5.697E-01 ------ Line Not Found ------
1280.95 ------ 1. 47 5.585E-01 ------ Line Not Found ------
1377.66 ------ 4.02 5.401E-01 ------ Line Not Found ------
1385. 30 ------ 0.78 5.391E-01 ------ Line Not Found ------
1401.48 ------ 1. 39 5.370E-01 ------ Line Not Found ------
1407.97 ------ 2.48 5.362E-01 ------ Line Not Found ------
1509.22 ------ 2.19 5.292E-01 ------ Line Not Found -------
1583.22 0. 72 5.296E-01 ------ Line Not Found ----*--
1661. 26 ------ 1.15 5.351E-01 ------ Line Not Found ------
1729.58 3.05 5.442E-01 ------ Line Not Found ------
1764.49 ------ 15.90 5.503E-01 ------ Line Not Found ------
1847.41 ------ 2.12 5.694E-01 ------ Line Not Found ------
PB-214 53.17 ------ 1.10 5.543E-01 ------ Line Not Found ------
74.81 20 6.52 1.690E+OO l.543E-06 1. 640E-06 42.76 77 .11 30 11. 00 1.786E+OO 1.257E-06 1.337E-06 29.23 87.19 ------ 3.88 2.129E+OO ------ Line Not Found ------
90.13 ------ 1.15 2.206E+OO ------ Line Not Found ------
241.92 7.46 2.067E+OO ------ Line Not Found ------
258.94 0.55 l.994E+OO ------ Line Not Found ------
295.09 31 19.20* 1.852E+OO 7.305E-07 7.766E-07 18.15 351. 87 35 37.10 1.662E+OO 4.754E-07 5.054E-07 18.66 785.83 1. 09 8.495E-01 ------ Line Not Found ------
839.00 ------ 0.59 7. 964E-01 ------ Line Not Found ------
Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30269 Acquisition date 29-MAY-2014 15:58:52 Nuclide Typo: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error AC-228 89. 96 ------ 3.40 2.201E+OO ------ Line Not Found ------
93.35 ------ 5.60 2.279E+OO ------ Line Not Found ------
99.55 ------ 1. 30 2.389E+OO ------ Line Not Found ------
105.36 ------ 2.00 2.463E+OO ------ Line Not Found ------
108.99 ------ 0.67 2.496E+OO ------ Line Not Found ------
129.03 ------ 2.90 2.562E+OO ------ Line Not Found ------
153.89 ------ 0.84 2.496E+OO ------ Line Not Found ------
209.39 ------ 4.10 2.221E+OO ------ Line Not Found ------
216.24 ------ 0.80 2.187E+OO ------ Line Not Found ------
270.26 ------ 3.80 l.948E+OO ------ Line Not Found ------
328.07 ------ 3.50 1.738E+OO ------ Line Not Found ------
338.42 ------ 12.40 1.704E+OO ------ Line Not Found ---*---
340.94 ------ 0.52 1. 696E+OO ------ Line Not Found ------
409.62 ------ 2.20 1. 499E+OO ------ Line Not Found ------
463.10 ------ 4.60 l.368E+OO ------ Line Not Found ------
562.65 ------ 1. 01 1.164E+OO ------ Line Not Found ------
581.52 ------ 3.00 1.131E+OO ------ Line Not Found ------
72 6. 63 ------ 0.87 9.173E-01 ------ Line Not Found ------
755.28 ------ 1. 32 8.833E-01 ------ Line Not Found ------
772.28 ------ 1. 09 8.641E-01 ------ Line Not Found ------
782.12 ------ 0.59 8.534E-01 ------ Line Not Found ------
794.79 ------ 4. 60 8.400E-01 ------ Line Not Found ------
830.59 ------ 0.63 8.043E-Ol ------ Line Not Found ------
835.60 ------ 1. 71 7.996E-01 ------ Line Not Found ------
840.44 ------ 0.94 7.951E-01 ------ Line Not Found ------
904.29 ------ 0.89 7.403E-01 ------ Line Not Found ------
911.16 19 29.00* 7.350E-01 7.582E-07 7. 616E-07 25.30 964. 64 ------ 5.80 6. 962E-Ol ------ Line Not Found ------
968. 97 ------ 17.40 6.933E-01 ------ Line Not Found ------
1246.60 ------ 0.57 5.673E-01 ------ Line Not Found ------
1459.19 ------ 1. 06 5.315E-01 ------ Line Not Found ------
1496.00 ------ 1. 05 5.296E-01 ------ Line Not Found ------
1501. 44 ------ 0.58 5.294E-01 ------ Line Not Found ------
1580.30 ------ 0.71 5.295E-01 ------ Line Not Found ------
1588.23 ------ 3.60 5.298E-01 ------ Line Not Found ------
1630.47 ------ 1. 95 5.324E-01 ------ Line Not Found ------
1638.10 ------ 0.54 5.330E-01 ------ Line Not Found ------
Flag: I I
- II
= Keyline
Minimum Detectable Activity Report Page : 7 Sample ID 30269 Acquisition date 29-MAY-2014 15:58:52 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)
BE-7 4. 477.61 7.1900E-07 MN-54 3. 834.83 1.0786E-07 MN-56 1. 846.81 7.2016E-08 C0-57 13. 122.06 7.3632E-08 C0-58 2. 810.79 9. 0871E-08 C0-60 1. 1332.50 1.1196E-07 SB-124 0. 602.73 2.1042E-08 SB-125 4. 427.88 2.3439E-07 CS-134 1. 604. 71 5.4608E-08 CS-137 2. 661.66 9.0421E-08