Health Physics Sample Records Sample ID: 142477 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140603BD 6 CULVERT# 12 lCom!!1_5>~J Resp Org: P4000 - PROJECT MANAGEMEt Cross Ref Sample ID: Priority: N
Contact:
COOPER, TERRY L Survey No:
Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA/RECOUNTED ON IHPS # 142524 Reviewed: DYNES, WILLIAM J Date: 06/05/14 07:24 Comments:
l_O~i.9i11_J Mat. SizeNolume: 756 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
CULVERT# 12 lf__olle~i~'!J Sample Tech: DYNES, WILLIAM J Sample Date: 06/03/14 08:20 CountTime: 900 (secs.)
Tritium Req: No Sample SizeNolume: 756 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA LJ~L_SSSJ Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: ~
lb!>_~tiori]
Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:
Stored By:, Date: 00/00/00 00:00 Sample Loe:
Other:
Material Loe:
06/19/2014 08:26 Page 1 of 3
Health Physics Samp=-=l~e_c_R_::__:e=--.:c:_:o:__:_r=ds-=----- ------------------------~
Sample ID: 142477 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
1406038D 6 CULVERT# 12 lAn~_lysifl Geometry ___ MCA ID Quant _ Units Method FP/AP Lab Analysis By Date Mod ID Mod Date 8_1L_marinelli_sand_ 30450 1000gr .047 PARK, MICHAEL C 06/16/14 13:33 lsoto~ Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 8E-7 AP 2.332E-6 3.99E-7 r 1.282% 7 0 K-40 NT 9.832E-6 1.23E-6 r 5.405% 40 0 CS-137 FP 1.088E-7 4.82E-8 r 0.060% 137 0 TL-208 NT 5.499E-7 1.235E-7 r 0.302% 208 0 P8-212 NT 6.506E-7 9.63E-8 r 0.358% 212 0 81-214 NT 5.151 E-7 9.64E-8 r 0.283% 214 0 P8-214 NT 9.097E-7 1.656E-7 r 0.500% 214 0 RN-222 NT 0.000167 0.0000688 r 91.810% 222 0 MN-54 AP 8.1391E-8 Iv 0.000% 54 0 MN-56 AP 9.5159E-8 Iv 0.000% 56 0 C0-57 AP 7.1487E-8 Iv 0.000% 57 0 C0-58 AP 1.034E-7 Iv 0.000% 58 0 C0-60 AP 1.6074E-7 Iv 0.000% 60 0 S8-124 AP 8.9806E-8 Iv' 0.000% 124 0 S8-125 FP 2.5599E-7 Iv 0.000% 125 0 CS-134 FP 9.9487E-8 Iv 0.000% 134
[ Analysis Review Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/16/14 13:46 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments:
06/19/2014 08:26 Page 2 of 3
*------ Health Physic~ Sample R e c o r d ~ - - - - - - - - - - - - - - - - - - - - - - - - - - -
Sample ID: 142477 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
1406038D 6 CULVERT# 12
[B;view/Approve J HP Review Reviewed: COOPER, TERRY L Date: 06/16/1413:46 Comments: Cs-137 is consistent with environmental levels Disposition Disposition: OTHER Result: Cs-137 is in the environment 1e-7uCi/gr range Remarks:
Final Approval Approved: COOPER, TERRY L Date: 06/16/1413:47 Comments:
06/19/2014 08:26 Page 3 of 3
- SONGS HEALTH PHYSICS REPORT 16-JUN-2014 13:27 *
- >>>>> SAMPLE P,./\RAMETERS <<<<< *
- Title 140603BD 6 CULVERT# 12 *
- ID 30450 Acquisition date: 5-JUN-2014 16:13:11. *
- Start Time: 5-JUN-2014 16:13:00. *
- Stop Time: 5-JUN-2014 16:13:00. Counting System U2GSP *
- Quantity l.OOOOOE+03 gr IHPS Sample Number: 142477 *
- Geometry B 11 marinelli sand 1 Analysis Library HP NATURAL *
- Operator: MICHAEL PARK *
- >>>>> B #42-TP11663A PARAMETERS<<<<< *
- Elapsed Live Time 0 00:07:00.73 Calibration 5-JUN-2014 08:35: *
- Elapsed Real Time 0 00:07:00.80 Energy Offset -4.96372E-01 *
- Deadtime 0.0% Energy Slope 5.00067E-01 *
- Activity Mult Factor: l.OOOOOE+OO Energy Tolerance: 1.00000 *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 7 238.48 79 19 1. 41 477.89 471 24 14.8 l.32E+OO PB-212 7 242.37 27 17 2.45 485.67 471 24 57.5 PB-214 1 295.22 39 3 2.28 591.36 587 11 18.2 1. 4 7E+OO PB-214 1 338.57 20 12 2.09 678.06 675 9 38.9 1.32E+OO 1 351.89 46 13 1.17 704.68 699 12 21. 3 l.05E+OO PB-214 1 477.57 41 2 1. 38 956.01 951 9 17.1 8.07E-01 BE-7 1 510.77 19 11 1. 89 1022.40 1017 11 41. 2 l.93E+OO RN-222 TL-208 1 583.34 32 5 1. 94 1167.53 1162 12 22.5 5.39E-Ol TL-208 1 609.25 29 0 1. 59 1219.35 1214 9 18.7 4.95E-01 BI-214 1 661. 99 12 7 1. 36 1324.81 1321 7 44.3 2.23E-01 CS-137 1 1460.86 69 0 2.04 2922.40 2916 13 12.5 6.49E-01 K-40
Summary of Nuclide Activity Page : 2 Sample ID : 30450 Acquisition date 5-JUN-2014 16:13:11 Total number of lines in spectrum 11 Number of unidentified lines 0 Number of lines tentatively identified by NID 11 100.00%
Nuclide Type : activation Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/gr uCi/gr 1-Sigma Error %Error Flags BE-7 53.29D 1. 00 2. 332E-06 2.332E-06 0.399E-06 17.11 A Total Activity 2.332E-06 2.332E-06 Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/gr uCi/gr 1-Sigma Error %Error Flags K-40 l.28E+09Y 1. 00 9.832E-06 9.832E-06 1. 230E-06 12.51 A TL-208 3.05M 2.09 2.633E-07 5.499E-07 1.235E-07 22. 4 6 A PB-212 10.64H 1. 00 6.480E-07 6.506E-07 0. 963E-07 14.80 A BI-214 19.90M 1.13 4.540E-07 5.151E-07 0.964E-07 18. 71 A PB-214 26.80M 1.10 8.278E-07 9.097E-07 l.656E-07 18.20 A RN-222 3.83D 1. 00 1.670E-04 1.670E-04 0.688E-04 41.21 A Total Activity 1.790E-04 1. 795E-04 Nuclide Type : fission Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/gr uCi/gr 1-Sigma Error %Error Flags CS-137 30.00Y 1. 00 1. 088E-07 1. 088E-07 0.482E-07 44.28 A Total Activity 1.088E-07 1. OBBE-07 Grand Total Activity: 1.814E-04 1.819E-04 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit
Unidentified Energy Lines Page : 3 Sample ID : 30450 Acquisition date : 5-JUN-2014 16:13:11 It Energy Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err %Eff Flags 1 338.57 20 12 2.09 678.06 675 9 4.70E-02 38.9 1.43E+OO T Flags: "T" = Tentatively associated
Interference Report Page : 4 Sample ID : 30450 Acquisition date 5-JUN-2014 16:13:11 No interference correction performed
Nuclide Line Activity Report Page : 5 Sample ID : 30450 Acquisition date 5-JUN-2014 16:13:11 Nuclide Type: activation Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/gr uCi/gr %Error BE-7 477.61 41 10.39* 1. 096E+OO 2.332E-06 2.332E-06 17 .11 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/gr uCi/gr %Error K-40 1460.83 69 10.67* 4.211E-01 9.832E-06 9.832E-06 12.51 TL-208 72. 80 ------ 2.14 1.070E+OO ------ Line Not Found ------
74.97 ------ 3.60 1.156E+OO ------ Line Not Found ------
84.79 ------ 1. 27 1.506E+OO ------ Line Not Found ------
252.45 ------ 0.80 1.745E+OO ------ Line Not Found ------
277.28 ------ 6.80 1. 645E+OO ------ Line Not Found ------
510.61 19 21. 60 1. 035E+OO 5.411E-07 1.130E-06 41. 21 583.02 32 86.00* 9.194E-01 2.633E-07 5.499E-07 22.46 763.06 ------ 1. 64 7.126E-01 ------ Line Not Found ------
860.30 ------ 12.00 6.341E-01 ------ Line Not Found ------
PB-212 74.81 ------ 10.50 1.150E+OO ------ Line Not Found ------
77 .11 ------ 17.70 1. 239E+OO ------ Line Not Found ------
87.19 ------ 6.27 1.579E+OO ------ Line Not Found ------
90 .13 ------ 1. 86 1. 662E+OO ------ Line Not Found ------
115 .12 ------ 0.59 2.085E+OO ------ Line Not Found ------
238.58 79 43.60* 1. 805E+OO 6.480E-07 6.506E-07 14.80 300.03 ------ 3.34 1. 562E+OO ------ Line Not Found ------
BI-214 76.86 ------ 0.58 1. 22 9E+OO ------ Line Not Found ------
79.29 ------ 0. 97 1.320E+OO ------ Line Not Found ------
609.31 29 46.10* 8.834E-01 4.540E-07 5.151E-07 rn. 71 665.44 ------ 1. 56 8.131E-01 ------ Line Not Found ------
768.35 ------ 4.88 7.078E-01 ------ Line Not Found ------
806.16 ------ 1. 23 6.754E-01 ------ Line Not Found ------
934.04 ------ 3.16 5.861E-01 ------ Line Not Found ------
1120.27 ------ 15.00 4.982E-01 ------ Line Not Found ------
1155.18 ------ 1. 69 4.860E-01 ------ Line Not Found ------
1238.11 ------ 5.92 4.615E-01 ------ Line Not Found ------
1280.95 ------ 1. 47 4.510E-01 ------ Line Not Found ------
1377. 66 ------ 4.02 4.323E-01 Line Not Found ------
1385.30 ------ 0.78 4. 311E-01 Line Not Found ------
1401.48 ------ 1. 39 4.287E-01 ------ Line Not Found ------
1407.97 ------ 2.48 4.277E-01 ------ Line Not Found ------
1509.22 ------ 2.19 4.165E-01 ------ Line Not Found ------
1583.22 ------ 0. 72 4.120E-01 ------ Line Not Found ------
1661.26 ------ 1.15 4.103E-01 ------ Line Not Found ------
1729.58 ------ 3.05 4.114E-01 ------ Line Not Found ------
1764.49 ------ 15.90 4.128E-01 ------ Line Not Found ------
1847.41 ------ 2.12 4.187E-01 ------ Line Not Found ------
PB-214 53.17 ------ 1.10 2.929E-01 ------ Line Not Found ------
74.81 ------ 6.52 1.150E+OO ------ Line Not Found ------
77 .11 ------ 11. 00 1.239E+OO ------ Line Not Found ------
87.19 ------ 3.88 1.579E+OO ------ Line Not Found ------
90.13 ------ 1.15 1.662E+OO Line Not Found ------
Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30450 Acquisition date 5-JUN-2014 16:13:11 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/gr uCi/gr %Error 241.92 27 7.46 1. 788E+OO 1.307E-06 l.437E-06 57.48 258.94 0.55 1.718E+OO ------ Line Not Found ------
295.09 39 19.20* l.579E+OO 8.278E-07 9.097E-07 18.20 351.87 46 37.10 1.395E+OO 5.744E-07 6.312E-07 21. 28 785.83 1. 09 6.925E-01 ------ Line Not Found ------
839.00 0.59 6.497E-01 ------ Line Not Found ------
RN-222 510.00 19 0.07* 1.035E+OO l.670E-04 1.670E-04 41. 21 Nuclide Type: fission Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/gr uCi/gr %Error CS-137 661.66 12 85.21* 8.171E-01 1.088E-07 1.088E-07 44.28 Flag: "*" Keyline
Minimum Detectable Activity Report Page : 7 Sample ID 30450 Acquisition date 5-JUN-2014 16:13:11 Bckgnd Energy MDA Nuclide Sum (keV.) (uCi/gr)
MN-54 1. 834.83 8.1391E-08 MN-56 2. 846.81 9.5159E-08 C0-57 14. 122.06 7.1487E-08 C0-58 3. 810.79 1.0340E-07 C0-60 4. 1173.24 l.6074E-07 SB-124 0. 1690.98 8.9806E-08 SB-125 6. 427.88 2.5599E-07 CS-134 5. 604.71 9.9487E-08