ML20034E188
Text
Health Physics Sample Records Sample ID: 142501 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
14060614BD 01 NORTH LAYDOWN #1 Common Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N
Contact:
COOPER, TERRY L Survey No:
Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 06/09/14 07:49 Comments:
Origin Mat. SizeNolume: 2250 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
NORTH LAYDOWN #1
!collection I Sample Tech: DYNES, WILLIAM J Sample Date: 06/06/14 08:45 Count Time: 900 (secs.)
Tritium Req: No Sample SizeNolume: 2250 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA 1*RLSSS I Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: fi7 1Cocation-l Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:
Stored By:, Date: 00/00/00 00:00 Sample Loe:
Other: COUNT TO MDA Material Loe:
06/19/2014 08:47 Page 1 of3
Health Physics Sample Records Sample ID: 142501 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
14060614BD 01 NORTH LAYDOWN #1 I Analysis I Geometry MCA ID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date B_1L_marinelli_sand_ 30424 2250GR .000 NEESE, DAVID J 06/09/14 20:43 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.00001128 1.33E-6 88.617% 40 0 TL-208 NT 2.139E-7 7.78E-8 1.680% 208 0 PB-212 NT 3.415E-7 1.245E-7 2.683% 212 0 Bl-214 NT 5.102E-7 1.036E-7 r 4.008% 214 0 PB-214 NT 3.834E-7 1.651E-7 3.012% 214 0 BE-7 AP 7.6574E-7 iv 0.000% 7 0 MN-54 AP 9.3778E-8 P' 0.000% 54 0 MN-56 AP 2.8548E-8 P' 0.000% 56 0 C0-57 AP 7.7894E-8 P' 0.000% 57 0 C0-58 AP 1.0717E-7 w 0.000% 58 0 C0-60 AP 1.0206E-7 iv 0.000% 60 0 SB-124 AP 7.4769E-8 w 0.000% 124 0 SB-125 FP 2.4717E-7 w 0.000% 125 0 CS-134 FP 9.9531E-8 w 0.000% 134 0 CS-137 FP 1.5889E-7 Iv 0.000% 137 I Analysis Review Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/11/14 07:22 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments:
06/19/2014 08:47 Page 2 of 3
Health Physics Sample Records Sample ID: 142501 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
14060614BD 01 NORTH LAYDOWN #1 I Review/Approve I HP Review Reviewed: COOPER, TERRY L Date: 06/11/14 07:22 Comments:
Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:
Final Approval Approved: COOPER, TERRY L Date: 06/11/14 07:22 Comments:
06/19/2014 08:47 Page 3 of3
- SONGS HEALTH PHYSICS REPORT 9-JUN-2014 20:38 *
- >>>>> SAMPLE PARAMETERS<<<<< *
- Title 14060614BD 01 NORTH LAYDOWN #1 *
- ID 30424 Acquisition date: 9-JUN-2014 20:35:46. *
- Start Time: 9-JUN-2014 20:35:00. *
- Stop Time: 9-JUN-2014 20:35:00. Counting System U2GSP *
- Quantity 2.25000E+03 GR IHPS Sample Number: 142501 *
- Geometry B lL marinelli_sand_l Analysis Library HP NATURAL *
- Operator: DAVID NEESE *
- >>>>> B #42-TP11663A PARAMETERS<<<<< *
- Elapsed Live Time 0 00:03:00.41 Calibration 9-JUN-2014 19:36: *
- Elapsed Real Time 0 00:03:00.46 Energy Offset -5.05220E-01 *
- Deadtime 0.0% Energy Slope 5.00079E-01 *
- Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1. 00000. *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1 77.32 37 26 1. 93 155.62 152 8 30.0 1. 08E+OO BI-214 PB-212 PB-214 1 238.44 40 52 1. 42 477.81 475 11 36.5 1.49E+OO PB-212 1 295.03 16 12 1. 83 590.98 587 9 43.1 1.12E+OO PB-214 1 351. 89 42 5 1. 32 704.68 699 12 20.2 7.61E-01 PB-214 1 583.62 15 5 1. 88 1168.08 1163 10 36.4 6.27E-01 TL-208 1 609.44 29 3 2.27 1219.71 1214 10 20.3 5.lOE-01 BI-214 1 1460.81 76 0 2.04 2922.27 2917 12 11. 7 1. 09E+OO K-40
Summary of Nuclide Activity Page : 2 Sample ID : 30424 Acquisition date 9-JUN-2014 20:35:46 Total number of lines in spectrum 7 Number of unidentified lines 0 Number of lines tentatively identified by NID 7 100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 l.28E+09Y 1. 00 1.128E-05 1.128E-05 0.133E-05 11. 75 A TL-208 3.05M 1. 65 1.300E-07 2.139E-07 0.778E-07 36.37 A PB-212 10.64H 1. 00 3.407E-07 3.415E-07 1.245E-07 36.45 A BI-214 19.90M 1. 08 4. 715E-07 5.102E-07 1.036E-07 20.30 A PB-214 26. SOM 1. 06 3.616E-07 3.834E-07 1.651E-07 43.07 A Total Activity 1.258E-05 1.273E-05 Grand Total Activity : l.258E-05 1. 273E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit
Unidentified Energy Lines Page : 3 Sample ID : 30424 Acquisition date 9-JUN-2014 20:35:46 None Flags: "T" Tentatively associated
Interference Report Page : 4 Sample ID : 30424 Acquisition date 9-JUN-2014 20:35:46 No interference correction performed
Nuclide Line Activity Report Page : 5 Sample ID : 30424 Acquisition date 9-JUN-2014 20:35:46 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 76 10.67* 4. 211E-01 1.128E-05 1.128E-05 11. 75 TL-208 72. 80 ------ 2.14 1.070E+OO ------ Line Not Found ------
74.97 ------ 3.60 1.156E+OO ------ Line Not Found ------
84.79 ------ 1. 27 1.506E+OO ------ Line Not Found ------
252.45 ------ 0.80 1.745E+OO ------ Line Not Found ------
277.28 ------ 6.80 1.645E+OO Line Not Found ------
510.61 ------ 21. 60 1.035E+OO ------ Line Not Found ------
583.02 15 86.00* 9.190E-01 1.300E-07 2.139E-07 36.37 763.06 ------ 1. 64 7.126E-01 ------ Line Not Found ------
860.30 ------ 12.00 6.341E-01 ------ Line Not Found ------
PB-212 74.81 ------ 10.50 1.150E+OO ------ Line Not Found ------
77 .11 37 17.70 1.247E+OO 1.112E-06 1.115E-06 2 9. 97 87.19 ------ 6.27 1. 579E+OO ------ Line Not Found ------
90.13 ------ 1. 86 l.662E+OO ------ Line Not Found ------
115 .12 ------ 0.59 2.085E+OO Line Not Found ------
238.58 40 43.60* 1.805E+OO 3.407E-07 3.415E-07 36.45 300.03 ------ 3.34 l.562E+OO ------ Line Not Found ------
BI-214 76. 86 37 0.58 l.247E+OO 3.394E-05 3.672E-05 29.97 79.29 ------ 0.97 1. 320E+OO ------ Line Not Found ------
609.31 29 46.10* 8.831E-01 4. 715E-07 5.102E-07 20.30 665.44 ------ 1. 56 8.131E-01 ------ Line Not Found ------
768.35 ------ 4.88 7.078E-01 ------ Line Not Found ------
806.16 ------ 1. 23 6.754E-01 ------ Line Not Found ------
934.04 ------ 3.16 5.861E-01 ------ Line Not Found ------
1120. 27 ------ 15.00 4.982E-01 ------ Line Not Found ------
1155 .18 ------ 1. 69 4.860E-01 ------ Line Not Found ------
1238 .11 ------ 5.92 4.615E-Ol ------ Line Not Found ------
1280.95 ------ 1. 47 4.510E-01 ------ Line Not Found ------
1377. 66 ------ 4.02 4.323E-01 ------ Line Not Found ------
1385.30 ------ 0.78 4. 311E-01 ------ Line Not Found ------
1401.48 ------ 1. 39 4.287E-01 Line Not Found ------
1407.97 ------ 2.48 4.277E-01 ------ Line Not Found ------
1509.22 ------ 2.19 4.165E-01 ------ Line Not Found ------
1583.22 ------ 0. 72 4.120E-01 ------ Line Not Found ------
1661.26 ------ 1.15 4.103E-01 ------ Line Not Found ------
1729.58 ------ 3.05 4 .114E-01 ------ Line Not Found ------
1764.49 ------ 15.90 4.128E-01 ------ Line Not Found ------
1847.41 ------ 2.12 4.187E-01 ------ Line Not Found ------
PB-214 53.17 ------ 1.10 2.929E-01 ------ Line Not Found ------
74.81 ------ 6.52 1.150E+OO Line Not Found ------
77 .11 37 11. 00 1.247E+OO 1. 789E-06 l.897E-06 29.97 87.19 ------ 3.88 1.579E+OO ------ Line Not Found ------
90.13 ------ 1.15 l.662E+OO ------ Line Not Found ------
241. 92 ------ 7.46 1. 790E+OO ------ Line Not Found ------
258.94 ------ 0.55 1. 718E+OO ------ Line Not Found ------
295.09 16 19.20* 1.579E+OO 3.616E-07 3.834E-07 43.07 351.87 42 37.10 1.395E+OO 5.403E-07 5.730E-07 20.20 785.83 ------ 1. 09 6.925E-01 ------ Line Not Found ------
839.00 ------ 0.59 6.497E-01 ------ Line Not Found ------
Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30424 Acquisition date 9-JUN-2014 20:35:46 Flag: "*" Keyline
Minimum Detectable Activity Report Page : 7 Sample ID 30424 Acquisition date 9-JUN-2014 20:35:46 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)
BE-7 5. 477.61 7.6574E-07 MN-54 2. 834.83 9.3778E-08 MN-56 0. 846.81 2.8548E-08 C0-57 16. 122.06 7.7894E-08 C0-58 3. 810.79 l.0717E-07 C0-60 1. 1173.24 l.0206E-07 SB-124 2. 602.73 7.4769E-08 SB-125 5. 427.88 2.4717E-07 CS-134 5. 604. 71 9.9531E-08 CS-137 9. 661. 66 l.5889E-07