Health Physics Sample Records Sample ID: 142497 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140605BD08 SOUTH LAY DOWN# 16 Common Resp Org: P4000 - PROJECT MANAGEMEt Cross Ref Sample ID: Priority: N

Contact:

COOPER, TERRY L Survey No:

Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 06/06/1410:00 Comments:

Origin I Mat. SizeNolume: 2006 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00

Description:

SOUTH LAY DOWN# 16 Collectiori]

Sample Tech: DYNES, WILLIAM J Sample Date: 06/05/14 08:30 Count Time: 900 (secs.)

Tritium Req: No Sample SizeNolume: 2006 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: ~

liocaJJonJ Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:

Stored By:, Date: 00/00/00 00:00 Sample Loe:

Other: COUNT TO MDA Material Loe:

06/19/2014 10:16 Page 1 of3

Health Physics Sample Records Sample ID: 142497 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140605BD08 SOUTH LAY DOWN# 16 Analysis Geometry MCAID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date

~~-----

A_1L_marinelli_sand- 1012 2006GR .000 DYNES, WILLIAM J 06/11/14 10:18 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.00001345 1.54E-6 r 87.085% 40 0 TL-208 NT 3.243E-7 9.06E-8 r 2.100% 208 0 PB-212 NT 5.252E-7 1.168E-7 r 3.401% 212 0 Bl-214 NT 3.868E-7 1.182E-7 r 2.504% 214 0 PB-214 NT 7.584E-7 1.957E-7 r 4.910% 214 0 BE-7 AP 4.2257E-7 Iv 0.000% 7 0 MN-54 AP 9.81E-8 Iv 0.000% 54 0 MN-56 AP 1.184E-7 Iv 0.000% 56 0 C0-57 AP 9.8611 E-8 fi7' 0.000% 57 0 C0-58 AP 7.5934E-8 Iv 0.000% 58 0 C0-60 AP 4.275E-8 w 0.000% 60 0 SB-124 AP 8.1198E-8 w 0.000% 124 0 SB-125 FP 2.6125E-7 rv 0.000% 125 0 CS-134 FP 9.4846E-8 Iv 0.000% 134 0 CS-137 FP 1.2398E-7 Iv 0.000% 137 C_1L_marinelli_sand- 30390 1000 gr .000 NEEBE, DAVID J 06/06/14 20:58 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.00002544 2.16E-6 r 64.572% 40 0 TL-208 NT 7.222E-7 1.114E-7 r 1.833% 208 0 Bl-212 NT 3.104E-6 8.26E-7 r 7.879% 212 0 PB-212 NT 1.271E-6 1.88E-7 r 3.226% 212 0 Bl-214 NT 9.97E-7 1.699E-7 r 2.531% 214 0 PB-214 NT 3.086E-6 2.95E-7 r 7.833% 214 0 RA-226 NT 3.758E-6 1.939E-6 r 9.539% 226 0 AC-228 NT 7.868E-7 1.959E-7 r 1.997% 228 0 U-235 NT 2.326E-7 1.2E-7 r 0.590% 235 0 BE-7 AP 1.0392E-6 w 0.000% 7 06/19/2014 10:16 Page 2 of 3

Health Physics Sample Records Sample ID: 142497 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized:

Description:

140605BD08 SOUTH LAY DOWN# 16

!Ana1ysisl Geom.-=--et_ry,___ _~ MCA ID Quant. Units Method FP/AP Lab Anal~!_~~_}'_ Date Mod ID Mod Date

-~----

C_1L_marinelli_sand_ 30390 1000gr .000 NEESE, DAVID J 06/06/14 20:58 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 MN-54 AP 1.4855E-7 iv 0.000% 54 0 MN-56 AP 1.6207E-7 iv 0.000% 56 0 C0-57 AP 1.3645E-7 w 0.000% 57 0 C0-58 AP 1.4329E-7 Iv 0.000% 58 0 C0-60 AP 1.5182E-7 Iv 0.000% 60 0 SB-124 AP 9.778E-8 Iv 0.000% 124 0 SB-125 FP 3.9874E-7 iv 0.000% 125 0 CS-134 FP 1.1969E-7 Iv 0.000% 134 0 CS-137 FP 1.7652E-7 Iv 0.000% 137 I Analysis Review Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/11/14 10:33 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:

Comments:

Review/Approve HP Review Reviewed: COOPER, TERRY L Date: 06/11/1410:34 Comments:

DiS!)OSition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:

Final Approval Approved: COOPER, TERRY L Date: 06/11/14 10:34 Comments:

06/19/2014 10:16 Page 3 of 3

  • SONGS HEALTH PHYSICS REPORT ll-JUN-2014 10:11 *
  • >>>>> SAMPLE PARAMETERS<<<<< *
  • Title 140605BD08 SOUTH LAY DOWN# 16 *
  • ID 1012 Acquisition date: ll-JUN-2014 10:08:13 *
  • Start Time: ll-JUN-2014 10:08:00 *
  • Stop Time: ll-JUN-2014 10:08:00 Counting System UlGSP *
  • Quantity 2.00600E+03 GR IHPS Sample Number: 142497 *
  • Geometry A 11 marinelli sand 1 Analysis Library HP NATURAL *
  • Operator: BILL DYNES *
  • >>>>> A -1922924 PARAMETERS<<<<< *
  • Elapsed Live Time 0 00:03:00.25 Calibration ll-JUN-2014 09:11 *
  • Elapsed Real Time 0 00:03:00.32 Energy Offset -1. 07429E-01 *
  • Deadtime 0.0% Energy Slope 4.99821E-01 *
  • Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1.00000 *
  • Half Life Ratio 8.00000 Sensitivity 5.00000
  • Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 238.70 60 25 1. 33 477.76 475 11 21. 8 1. 20E+OO PB-212 1 295.44 32 10 1. 32 591. 27 586 10 25.5 3.54E-01 PB-214 1 351.90 45 7 1. 81 704.21 700 9 17.9 4.18E-01 PB-214 1 583.30 26 7 2.29 1167.10 1163 10 27.3 6.82E-01 TL-208 1 609.45 21 7 1. 34 1219.42 1214 9 30.2 4.16E-01 BI-214 1 1460.83 86 0 2.23 2922.15 2917 12 10.9 7.35E-01 K-40

Summary of Nuclide Activity Page : 2 Sample ID : 1012 Acquisition date 11-JUN-2014 10:08:13 Total number of lines in spectrum 6 Number of unidentified lines 0 Number of lines tentatively identified by NID 6 100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 1.28E+09Y 1. 00 1.345E-05 l.345E-05 0.154E-05 11. 4 7 A TL-208 3.05M 1. 45 2.232E-07 3.243E-07 0.906E-07 27.93 A PB-212 10.64H 1. 00 5.242E-07 5.252E-07 1.168E-07 22.24 A BI-214 19.90M 1. 06 3.644E-07 3.868E-07 1.182E-07 30.55 A PB-214 26.SOM 1. 05 7.254E-07 7.584E-07 1.957E-07 25.81 A Total Activity l.529E-05 l.544E-05 Grand Total Activity : 1.529E-05 1. 544E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit

Unidentified Energy Lines Page : 3 Sample ID : 1012 Acquisition date ll-JUN-2014 10:08:13 None Flags: "T" Tentatively associated

Interference Report Page : 4 Sample ID : 1012 Acquisition date ll-JUN-2014 10:08:13 No interference correction performed

Nuclide Line Activity Report Page : 5 Sample ID : 1012 Acquisition date 11-JUN-2014 10:08:13 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 86 10.67* 4.482E-01 l.345E-05 1. 345E-05 11. 4 7 TL-208 72. 80 ------ 2.14 1.155E+OO ------ Line Not Found ------

74.97 ------ 3.60 1. 239E+OO ------ Line Not Found ------

84.79 ------ 1. 27 1.578E+OO ------ Line Not Found ------

252.45 ------ 0.80 1.887E+OO ------ Line Not Found ------

277.28 ------ 6.80 1.783E+OO ------ Line Not Found ------

510.61 ------ 21. 60 1.121E+OO ------ Line Not Found ------

583.02 26 86.00* 9.950E-01 2.232E-07 3.243E-07 27.93 763.06 ------ 1. 64 7.714E-01 ------ Line Not Found ------

860.30 ------ 12.00 6.870E-Ol ------ Line Not Found ------

PB-212 74.81 ------ 10.50 1.233E+OO ------ Line Not Found ------

77 .11 ------ 17.70 l.319E+OO ------ Line Not Found ------

87.19 ------ 6.27 l.650E+OO ------ Line Not Found ------

90.13 ------ 1. 86 1.730E+OO ------ Line Not Found ------

115.12 ------ 0.59 2.162E+OO ------ Line Not Found ------

238.58 60 43.60* l.948E+OO 5.242E-07 5.252E-07 22.24 300.03 ------ 3.34 l.694E+OO ------ Line Not Found ------

BI-214 76.86 ------ 0.58 1.310E+OO ------ Line Not Found ------

79.29 ------ 0.97 1.397E+OO ------ Line Not Found ------

609.31 21 46.10* 9.555E-01 3.644E-07 3.868E-07 30.55 665.44 ------ 1. 56 8.797E-01 ------ Line Not Found ------

768.35 ------ 4.88 7.663E-01 ------ Line Not Found ------

806.16 ------ 1. 23 7.315E-01 ------ Line Not Found ------

934.04 ------ 3.16 6.352E-01 ------ Line Not Found ------

1120. 27 ------ 15.00 5.391E-01 ------ Line Not Found ------

1155.18 ------ 1. 69 5.255E-01 ------ Line Not Found ------

1238 .11 ------ 5.92 4.976E-01 ------ Line Not Found ------

1280.95 ------ 1. 47 4.855E-01 ------ Line Not Found ------

1377. 66 ------ 4.02 4.629E-01 ------ Line Not Found ------

1385.30 ------ 0.78 4.614E-01 ------ Line Not Found ------

1401. 48 ------ 1. 39 4.583E-01 ------ Line Not Found ------

1407.97 ------ 2.48 4.571E-01 ------ Line Not Found ------

1509.22 ------ 2.19 4.415E-01 ------ Line Not Found ------

1583.22 ------ 0.72 4.336E-01 ------ Line Not Found ------

1661. 26 ------ 1.15 4.280E-01 ------ Line Not Found ------

1729.58 ------ 3.05 4.255E-01 ------ Line Not Found ------

1764.49 ------ 15.90 4.249E-01 ------ Line Not Found ------

1847.41 ------ 2.12 4.256E-01 ------ Line Not Found ------

PB-214 53.17 ------ 1.10 3.707E-01 ------ Line Not Found ------

74.81 ------ 6.52 1.233E+OO ------ Line Not Found ------

77 .11 ------ 11. 00 1.319E+OO ------ Line Not Found ------

87.19 ------ 3.88 l.650E+OO ------ Line Not Found ------

90.13 ------ 1.15 1. 730E+OO ------ Line Not Found ------

241. 92 ------ 7.46 1.933E+OO ------ Line Not Found ------

258.94 ------ 0.55 1.859E+OO ------ Line Not Found ------

295.09 32 19.20* 1.712E+OO 7.254E-07 7.584E-07 25.81 351.87 45 37.10 1.515E+OO 5.990E-07 6.263E-07 18.47 785.83 ------ 1. 09 7.498E-01 ------ Line Not Found ------

839.00 ------ 0.59 7.038E-01 ------ Line Not Found ------

Nuclide Line Activity Report (continued) Page : 6 Sample ID : 1012 Acquisition date ll-JUN-2014 10:08:13 Flag: "*" Keyline

Minimum Detectable Activity Report Page : 7 Sample ID : 1012 Acquisition date ll-JUN-2014 10:08:13 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)

BE-7 1. 477.61 4. 2257E*-07 MN-54 2. 834.83 9.BlOOE-08 MN-56 3. 846.81 1.1840E-07 C0-57 23. 122.06 9.8611E-08 C0-58 1. 810.79 7.5934E-08 C0-60 0. 1332.50 4.2750E-08 SB-124 3. 602.73 8 .1198E-08 SB-125 5. 427.88 2.6125E-07 CS-134 4. 604. 71 9.4846E-08 CS-137 4. 661.66 l.2398E-07