Health Physics Sample Records Sample ID: 142496 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140605BD06 SOUTH LAY DOWN# 14 Common Resp Org: P4000 - PROJECT MANAGEMEt Cross Ref Sample ID: Priority: N

Contact:

COOPER, TERRY L Survey No:

Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 06/06/14 09:52 Comments:

Origin I Mat. SizeNolume: 1970 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00

Description:

SOUTH LAY DOWN #14 Collection]

Sample Tech: DYNES, WILLIAM J Sample Date: 06/05/14 09:05 Count Time: 900 (secs.)

Tritium Req: No Sample SizeNolume: 1970 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA RLSSS Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: ~

l.bQcation I Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:

Stored By:, Date: 00/00/00 00:00 Sample Loe:

Other: COUNT TO MDA Material Loe:

06/19/201410:16 Page 1 of 3

Health Physics Sample Records Sample ID: 142496 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140605BD06 SOUTH LAY DOWN# 14 Analysis Geometry MCAID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date B_ 1L_ marinelli_sand- 30393 1970GR .000 NEESE, DAVID J 06/06/14 21:13 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 8.71E-6 1.266E-6 r 82.671% 40 0 TL-208 NT 3.702E-7 7.56E-8 r 3.514% 208 0 PB-212 NT 3.88E-7 1.234E-7 r 3.683% 212 0 81-214 NT 5.202E-7 1.115E-7 r 4.937% 214 0 PB-214 NT 5.474E-7 1.59E-7 r 5.196% 214 0 BE-7 AP 7.6477E-7 w 0.000% 7 0 MN-54 AP 8.5646E-8 IV 0.000% 54 0 MN-56 AP 1.4458E-7 IV 0.000% 56 0 C0-57 AP 8.6914E-8 IV 0.000% 57 0 C0-58 AP 7.9562E-8 w 0.000% 58 0 C0-60 AP 8.6724E-8 IV 0.000% 60 0 SB-124 AP 7.5097E-8 IV 0.000% 124 0 SB-125 FP 1.9975E-7 IV 0.000% 125 0 CS-134 FP 6.4392E-8 w 0.000% 134 0 CS-137 FP 1.2974E-7 w 0.000% 137 Analysis Review Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/11/14 07:03 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:

Comments:

06/19/201410:16 Page 2 of 3

Health Physics Sample Records Sample ID: 142496 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140605BD06 SOUTH LAY DOWN# 14 I Review/Approve I HP Review Reviewed: COOPER, TERRY L Date: 06/11/14 07:04 Comments:

Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:

Final Approval Approved: COOPER, TERRY L Date: 06/11/14 07:04 Comments:

06/19/2014 10:16 Page 3 of 3

  • SONGS HEALTH PHYSICS REPORT 6-JUN-2014 21:07 *
  • >>>>> SAMPLE PARAMETERS<<<<< *
  • Title 140605BD06 SOUTH LAY DOWN# 14 *
  • ID 30393 Acquisition date: 6-JUN-2014 21:04:29. *
  • Start Time: 6-JUN-2014 21:04:00. *
  • Stop Time: 6-JUN-2014 21:04:00. Counting System U2GSP *
  • Quantity l.97000E+03 GR IHPS Sample Number: 142496 *
  • Geometry B lL marinelli_sand_l Analysis Library HP NATURAL *
  • Operator: DAVID NEEBE *
  • >>>>> B #42-TP11663A PARAMETERS<<<<< *
  • Elapsed Live Time 0 00:03:00.45 Calibration 6-JUN-2014 20:09: *
  • Elapsed Real Time 0 00:03:00.49 Energy Offset -4.40560E-01 *
  • Deadtime 0.0% Energy Slope 5.00074E-01 *
  • Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1.00000 *
  • Half Life Ratio 8.00000 Sensitivity 5.00000
  • Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 238.76 40 34 1. 23 478.34 475 10 31. 8 1. 31E+OO PB-212 1 295.44 21 7 1. 48 591. 68 588 7 29.1 2.51E-01 PB-214 1 583.39 25 0 1. 81 1167.50 1162 10 20.4 5.0lE-01 TL-208 1 609.26 26 2 2.30 1219.23 1215 9 21. 4 5.54E-01 BI-214 1 1460.76 51 0 2.13 2922.04 2916 13 14.5 6.84E-01 K-40

Summary of Nuclide Activity Page : 2 Sample ID : 30393 Acquisition date 6-JUN-2014 21:04:29 Total number of lines in spectrum 5 Number of unidentified lines 0 Number of lines tentatively identified by NID 5 100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 l.28E+09Y 1. 00 8.710E-06 8.710E-06 l.266E-06 14.54 A TL-208 3.05M 1. 54 2.403E-07 3.702E-07 0.756E-07 20.41 A PB-212 10.64H 1. 00 3.872E-07 3.BBOE-07 1.234E-07 31. 80 A BI-214 19.90M 1. 07 4.856E-07 5.202E-07 1. 115E-07 21. 43 A PB-214 26.80M 1. 05 5.201E-07 5.474E-07 1. 590E-07 29.05 A Total Activity 1.034E-05 l.054E-05 Grand Total Activity : 1.034E-05 1.054E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit

Unidentified Energy Lines Page : 3 Sample ID : 30393 Acquisition date 6-JUN-2014 21:04:29 None Flags: "T" Tentatively associated

Interference Report Page : 4 Sample ID : 30393 Acquisition date 6-JUN-2014 21:04:29 No interference correction performed

Nuclide Line Activity Report Page : 5 Sample ID : 30393 Acquisition date 6-JUN-2014 21:04:29 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 51 10.67* 4. 211E-01 8, 710E-06 8. 710E-06 14.54 TL-208 72. 80 ------ 2.14 1. 070E+OO ------ Line Not Found ------

74.97 ------ 3.60 1.156E+OO ------ Line Not Found ------

84.79 ------ 1. 27 1. 506E+OO ------ Line Not Found ------

252.45 ------ 0.80 l.745E+OO ------ Line Not b,ound ------

277.28 ------ 6.80 1.645E+OO ------ Line Not Found ------

510.61 ------ 21. 60 1.035E+OO ------ Line Not Found ------

583.02 25 86.00* 9.194E-01 2.403E-07 3.702E-07 20.41 763.06 ------ 1. 64 7.126E-Ol ------ Line Not Found ------

860.30 ------ 12.00 6.341E-01 ------ Line Not Found ------

PB-212 74.81 ------ 10.50 1.150E+OO ------ Line Not Found ------

77 .11 ------ 17.70 1. 239E+OO ------ Line Not Found ------

87.19 ------ 6.27 1. 579E+OO ------ Line Not Found ------

90.13 ------ 1. 86 1. 662E+OO ------ Line Not Found ------

115. 12 ------ 0.59 2.085E+OO ------ Line Not Found ------

238.58 40 43.60* 1. 804E+OO 3.872E-07 3.880E-07 31. 80 300.03 ------ 3.34 1. 562E+OO ------ Line Not Found ------

BI-214 76. 86 ------ 0.58 1.229E+OO ------ Line Not Found ------

79.29 ------ 0.97 1. 320E+OO ------ Line Not Found ------

609.31 26 46.10* 8.834E-01 4.856E-07 5.202E-07 21. 43 665.44 ------ 1. 56 8.131E-01 ------ Line Not Found ------

768.35 ------ 4.88 7.078E-01 ------ Line Not Found ------

806.16 ------ 1. 23 6.754E-Ol ------ Line Not Found ------

934.04 ------ 3.16 5.861E-01 ------ Line Not Found ------

1120. 27 ------ 15.00 4.982E-01 ------ Line Not Found ------

1155 .18 ------ 1. 69 4.860E-01 ------ Line Not Found ------

1238. 11 ------ 5.92 4.615E-01 ------ Line Not Found ------

1280.95 ------ 1. 47 4.510E-Ol ------ Line Not Found ------

1377. 66 ------ 4.02 4.323E-01 ------ Line Not Found ------

1385.30 ------ 0.78 4. 311E-01 ------ Line Not Found ------

1401.48 ------ 1. 39 4.287E-01 ------ Line Not Found ------

1407.97 ------ 2.48 4.277E-01 ------ Line Not Found ------

1509.22 ------ 2.19 4.165E-01 ------ Line Not Found ------

1583.22 ------ 0.72 4.120E-01 ------ Line Not Found ------

1661. 26 ------ 1.15 4.103E-01 ------ Line Not Found ------

1729.58 ------ 3.05 4.114E-01 ------ Line Not Found ------

1764.49 ------ 15.90 4.128E-01 ------ Line Not Found ------

1847.41 ------ 2.12 4.187E-01 ------ Line Not Found ------

PB-214 53.17 ------ 1.10 2.929E-01 ------ Line Not Found ------

74.81 ------ 6.52 1.150E+OO ------ Line Not Found ------

77 .11 ------ 11. 00 1.239E+OO ------ Line Not Found ------

87.19 ------ 3.88 1.579E+OO ------ Line Not Found ------

90 .13 ------ 1.15 1.662E+OO ------ Line Not Found ------

241. 92 ------ 7.46 1.790E+OO ------ Line Not Found ------

258.94 ------ 0.55 1. 718E+OO ------ Line Not Found ------

295.09 21 19.20* 1.578E+OO 5.201E-07 5.474E-07 29.05 351. 87 ------ 37.10 1.395E+OO ------ Line Not Found ------

785.83 ------ 1. 09 6.925E-01 ------ Line Not Found ------

839.00 ------ 0.59 6.497E-01 ------ Line Not Found ------

Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30393 Acquisition date 6-JUN-2014 21:04:29 Flag: "*" Keyline

Minimum Detectable Activity Report Page : 7 Sample ID 30393 Acquisition date 6-JUN-2014 21:04:29 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)

BE-7 4. 477.61 7.6477E-07 MN-54 1. 834.83 8.5646E-08 MN-56 4. 846.81 1. 4458E-07 C0-57 15. 122.06 8.6914E-08 C0-58 1. 810.79 7.9562E-08 C0-60 0. 1332.50 8. 6724E-08 SB-124 2. 602.73 7.5097E-08 SB-125 2. 427.88 1. 9975E-07 CS-134 1. 604. 71 6.4392E-08 CS-137 4. 661. 66 1. 2974E-07