Health Physics Sample Records Sample ID: 142495 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140605BD06 SOUTH LAY DOWN# 12 lg_Qmm~
Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N
Contact:
COOPER, TERRY L Survey No:
Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 06/06/14 09:38 Comments:
LQrtgin I Mat. SizeNolume: 1883 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
SOUTH LAY DOWN #12 I Collection Sample Tech: DYNES, WILLIAM J Sample Date: 06/05/14 09:20 Count Time: 900 (secs.)
Tritium Req: No Sample SizeNolume: 1883 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA lkLsssl Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: f\7' LLocationl Unit: NON~UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:
Stored By:, Date: 00/00/00 00:00 Sample Loe:
Other: COUNT TO MDA Material Loe:
06/19/2014 10:05 Page 1 of3
Health Physics Sample Records Sample ID: 142495 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized:
Description:
140605BD06 SOUTH LAY DOWN# 12
[AnalysisJ Geometry. _ __ MCA ID Quant. Units Method FP/AP Lab Anal¥_sis By Date Mod ID Mod Date B_1 L_marinelli_sand_ 30392 1883GR .000 NEESE, DAVID J 06/06/14 20:58 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.000011811.45E-6 85.779% 40 0 PB-212 NT 5.708E-7 1.346E-7 r 4.146% 212 0 Bl-214 NT 6.045E-7 1.45E-7 4.391% 214 0 PB-214 NT 7.827E-7 1.777E-7 5.685% 214 0 BE-7 AP 8.8749E-7 IV 0.000% 7 0 MN-54 AP 1.2811E-7 IV 0.000% 54 0 MN-56 AP 9.2536E-8 IV 0.000% 56 0 C0-57 AP 7.8648E-8 IV 0.000% 57 0 C0-58 AP 1.5594E-7 IV 0.000% 58 0 C0-60 AP 4.8849E-8 w 0.000% 60 0 SB-124 AP 1.2513E-7 w 0.000% 124 0 SB-125 FP 3.9241E-7 IV 0.000% 125 0 CS-134 FP 1.0923E-7 w 0.000% 134 0 CS-137 FP 1.2077E-7 IV 0.000% 137 1
Analysis-Review
~-~-----*-----
I Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/11/14 06:48 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments:
06/19/2014 10:05 Page 2 of 3
Health Physics Sample Records Sample ID: 142495 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140605BD06 SOUTH LAY DOWN# 12
[ Review/Approve I HP Review Reviewed: COOPER, TERRY L Date: 06/11/14 06:49 Comments:
Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:
Final Approval Approved: COOPER, TERRY L Date: 06/11/14 06:49 Comments:
06/19/2014 10:05 Page 3 of 3
- SONGS HEALTH PHYSICS REPORT 6-JUN-2014 20:56 *
- >>>>> SAMPLE PARAMETERS<<<<< *
- Title 140605BD06 SOUTH LAY DOWN# 12 *
- ID 30392 Acquisition date: 6-JUN-2014 20:53:09. *
- Start Time: 6-JUN-2014 20:53:00. *
- Stop Time: 6-JUN-2014 20:53:00. Counting System U2GSP *
- Quantity 1.88300E+03 GR IHPS Sample Number: 142495 *
- Geometry B lL marinelli sand 1 Analysis Library HP NATURAL *
- Operator: DAVID NEEBE *
- >>>>> B #42-TP11663A PARAMETERS<<<<< *
- Elapsed Live Time 0 00:03:00.42 Calibration 6-JUN-2014 20:09: *
- Elapsed Real Time 0 00:03:00.46 Energy Offset -4.40560E-01 *
- Deadtime 0.0% Energy Slope 5.00074E-01 *
- Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1. 00000 *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 238.40 56 35 1. 93 477.61 475 11 23.6 3.96E+OO PB-212 1 295.24 29 5 1. 61 591.27 586 9 22.7 1. 32E+OO PB-214 1 351. 76 45 6 3.13 704.30 699 15 19.3 8.lOE-01 PB-214 1 609.40 29 6 1. 83 1219.52 1214 11 24.0 2.32E-01 BI-214 1 1460.86 67 0 2.49 2922.24 2915 13 12.3 6.37E-01 K-40
Summary of Nuclide Activity Page : 2 Sample ID : 30392 Acquisition date 6-JUN-2014 20:53:09 Total number of lines in spectrum 5 Number of unidentified lines 0 Number of lines tentatively identified by NID 5 100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 1.28E+09Y 1. 00 1.lBlE-05 1. lBlE-05 0.145E-05 12.27 A PB-212 10.64H 1. 00 5.697E-07 5.708E-07 l.346E-07 23.58 A BI-214 19.90M 1. 06 5.709E-07 6.045E-07 1.450E-07 23.99 A PB-214 26.BOM 1. 04 7.500E-07 7.827E-07 1.777E-07 22. 71 A Total Activity 1.370E-05 1. 377E-05 Grand Total Activity : l.370E-05 1. 377E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit
Unidentified Energy Lines Page : 3 Sample ID : 30392 Acquisition date 6-JUN-2014 20:53:09 None Flags: "T" Tentatively associated
Interference Report Page : 4 Sample ID : 30392 Acquisition date 6-JUN-2014 20:53:09 No interference correction performed
Nuclide Line Activity Report Page : 5 Sample ID : 30392 Acquisition date 6-JUN-2014 20:53:09 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 67 10.67* 4. 211E-01 1.181E-05 1.181E-05 12.27 PB-212 74.81 ------ 10.50 1.150E+OO ------ Line Not Found ------
77 .11 ------ 17.70 1.239E+OO ------ Line Not Found ------
87.19 ------ 6.27 1.579E+OO ------ Line Not Found ------
90.13 ------ 1. 86 l.662E+OO ------ Line Not Found ------
115 .12 ------ 0.59 2.085E+OO ------ Line Not Found ------
238.58 56 43.60* l.806E+OO 5.697E-07 5.708E-07 23.58 300.03 ------ 3.34 1.562E+OO ------ Line Not Found ------
BI-214 76.86 ------ 0.58 1.229E+OO ------ Line Not Found ------
79.29 ------ 0.97 1.320E+OO ------ Line Not Found ------
609.31 29 46.10* 8.832E-01 5.709E-07 6.045E-07 23.99 665.44 ------ 1. 56 8 .131E-01 ------ Line Not Found ------
7 68. 35 ------ 4.88 7.078E-01 ------ Line Not Found ------
806.16 ------ 1. 23 6.754E-01 ------ Line Not Found ------
934.04 ------ 3.16 5.861E-01 ------ Line Not Found ------
1120. 27 ------ 15.00 4.982E-01 ------ Line Not Found ------
1155. 18 ------ 1. 69 4.860E-01 ------ Line Not Found ------
1238. 11 ------ 5.92 4.615E-01 ------ Line Not Found ------
1280.95 ------ 1. 4 7 4.510E-Ol ------ Line Not Found ------
1377.66 ------ 4.02 4.323E-01 ------ Line Not Found ------
1385.30 ------ 0.78 4. 311E-01 ------ Line Not Found ------
1401. 48 ------ 1. 39 4.287E-01 ------ Line Not Found ------
1407.97 ------ 2.48 4.277E-01 ------ Line Not Found ------
1509.22 ------ 2.19 4.165E-01 ------ Line Not Found ------
1583.22 ------ 0.72 4.120E-01 ------ Line Not Found ------
1661. 26 ------ 1.15 4.103E-01 ------ Line Not Found ------
1729.58 ------ 3.05 4.114E-01 ------ Line Not Found ------
1764.49 ------ 15.90 4.128E-01 ------ Line Not Found ------
1847.41 ------ 2.12 4.187E-01 ------ Line Not Found ------
PB-214 53.17 ------ 1.10 2.929E-01 ------ Line Not Found ------
74.81 ------ 6.52 1.150E+OO ------ Line Not Found ------
77 .11 ------ 11. 00 1.239E+OO ------ Line Not Found ------
87.19 ------ 3.88 l.579E+OO ------ Line Not Found ------
90.13 ------ 1.15 l.662E+OO ------ Line Not Found ------
241.92 ------ 7.46 1.790E+OO ------ Line Not Found ------
258.94 ------ 0.55 1. 718E+OO ------ Line Not Found ------
295.09 29 19.20* l.579E+OO 7.500E-07 7,827E-07 22.71 351.87 45 37.10 l.396E+OO 6.988E-07 7.292E-07 19.31 785.83 --*---- 1. 09 6.925E-01 ------ Line Not Found ------
839.00 ------ 0.59 6.497E-01 ------ Line Not Found ------
Flag: "*" Keyline
\ '
Minimum Detectable Activity Report Page : 6 Sample ID 30392 Acquisition date 6-JUN*-2014 20: 53: 09 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)
BE-7 5. 477.61 8.8749E-07 MN-54 3. 834.83 1. 2811E-07 MN-56 1. 846.81 9.2536E-08 C0-57 11. 122.06 7.8648E-08 C0-58 5. 810.79 1.5594E-07 C0-60 0. 1332. 50 4.8849E-08 SB-124 6. 602.73 1.2513E-07 SB-125 10. 427.88 3.9241E-07 CS-134 4. 604. 71 l.0923E-07 CS-137 3. 661. 66 l.2077E-07