ML20034E019
Text
Health Physics Sample Records Sample ID: 142510 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
14060614BD 10 NORTH LAYDOWN # 20 lgommoi::iJ Resp Org: P4000 - PROJECT MANAGEMEf Cross Ref Sample ID: Priority: N
Contact:
COOPER, TERRY L Survey No:
Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 06/09/14 09:08 Comments: COUNT TO MDA Origin I Mat. SizeNolume: 1883 GRAMS DocmnUMO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
NORTH LAYDOWN # 20 I Collection I Sample Tech: DYNES, WILLIAM J Sample Date: 06/06/14 12:25 Count Time: 900 (secs.)
Tritium Req: Yes Sample SizeNolume: 1883 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA I-R.1...sss-l Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: j\7' ILocai-ionJ Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:
Stored By:, Date: 00/00/00 00:00 Sample Loe:
Other: COUNT TO MDA Material Loe:
06/19/2014 09:18 Page 1 of 3
Health Physics Sample Records Sample ID: 142510 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
14060614BD 10 NORTH LAYDOWN # 20
[A~_ly~is Geometry*-~~~ MCA ID - Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date
~-
A_1L_marinelli_sand_ 30426 1883GR .000 NEESE, DAVID J 06/09/14 20:48 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.00001044 1.24E-6 r 83.537% 40 0 TL-208 NT 3.521E-7 7.0E-8 2.817% 208 0 PB-212 NT 6.09E-7 8.47E-8 r 4.873% 212 0 Bl-214 NT 4.371E-7 1.033E-7 3.497% 214 0 PB-214 NT 6.593E-7 1.341 E-7 5.275% 214 0 BE-7 AP 7.0081E-7 IV 0.000% 7 0 MN-54 AP 1.2235E-7 IV 0.000% 54 0 MN-56 AP 7.57E-8 w 0.000% 56 0 C0-57 AP 7.0423E-8 w 0.000% 57 0 C0-58 AP 9.0057E-8 IV 0.000% 58 0 C0-60 AP 3.9271E-8 IV 0.000% 60 0 SB-124 AP 5.4748E-8 IV 0.000% 124 0 SB-125 FP 2.772E-7 IV 0.000% 125 0 CS-134 FP 8.456E-8 IV 0.000% 134 0 CS-137 FP 1.1363E-7 IV 0.000% 137 Analysis Review Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/11/14 08:15 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments:
06/19/2014 09:18 Page 2 of 3
~
Health Physics Sample Records Sample ID: 142510 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized:
Description:
1406061480 10 NORTH LAYDOWN # 20 I Review/Approve I HP Eng Review Reviewed: COOPER, TERRY L Date: 06/11/14 08:15 Comments:
--~---~-----~------------Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:
Final Approval Approved: COOPER, TERRY L Date: 06/11/14 08:15 Comments:
06/19/2014 09:18 Page 3 of 3
- SONGS HEALTH PHYSICS REPORT 9-JUN-2014 20:46 *
- >>>>> SAMPLE PARAMETERS<<<<< *
- Title 14060614BD 10 NORTH LAYDOWN # 20 *
- ID 30426 Acquisition date: 9-JUN-2014 20:43:46. *
- Start Time: 9-JUN-2014 20:43:00. *
- Stop Time: 9-JUN-2014 20:43:00. Counting System U2GSP *
- Quantity 1.88300E+03 GR IHPS Sample Number: 142510 *
- Geometry A 11 marinelli_sand_l Analysis Library HP NATURAL *
- Operator: DAVID NEEBE *
- >>>>> A #41-TP11679B PARAMETERS<<<<< *
- Elapsed Live Time 0 00:03:00.45 Calibration 9-JUN-2014 19:32: *
- Elapsed Real Time 0 00:03:00.50 Energy Offset 2.30553E-01 *
- Deadtime 0.0% Energy Slope 4.99505E-01 *
- Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1. 00000 *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 77.01 28 45 1. 69 153. 71 151 7 42.5 3.46E+OO BI-214 PB-212 PB-214 1 238.54 69 8 1. 35 477.10 473 8 13.9 5.73E-01 PB-212 1 295.03 28 0 1. 50 590.18 586 9 20.3 1. 4 6E+OO PB-214 1 351. 94 38 2 1. 77 704.14 699 9 17.7 6.84E-01 PB-214 1 582.90 26 0 1. 95 1166.53 1162 10 19.9 4.23E-01 TL-208 1 609.16 25 4 1. 93 1219.10 1215 8 23.6 1.40E+OO BI-214 1 1460.61 74 0 1. 91 2923.87 2918 12 11. 9 1.23E+OO K-40
Summary of Nuclide Activity Page : 2 Sample ID : 30426 Acquisition date 9-JUN-2014 20:43:46 Total number of lines in spectrum 7 Number of unidentified lines 0 Number of lines tentatively identified by NID 7 100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 1.28E+09Y 1. 00 l.044E-05 l.044E-05 0.124E-05 11. 86 A TL-208 3.05M 1. 64 2.141E-07 3.521E-07 0.700E-07 19.89 A PB-212 10.64H 1. 00 6.075E-07 6.090E-07 0.847E-07 13.91 A BI-214 19.90M 1. 08 4.040E-07 4.371E-07 l.033E-07 23.64 A PB-214 26.80M 1. 06 6.218E-07 6.593E-07 1. 341E-07 20.35 A Total Activity 1. 229E-05 l.250E-05 Grand Total Activity : 1. 229E-05 1.250E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit
Unidentified Energy Lines Page : 3 Sample ID : 30426 Acquisition date 9-JUN-2014 20:43:46 None Flags: "T" Tentatively associated
Interference Report Page : 4 Sample ID : 30426 Acquisition date 9-JUN-2014 20:43:46 No interference correction performed
Nuclide Line Activity Report Page : 5 Sample ID : 30426 Acquisition date 9-JUN-2014 20:43:46 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 74 10.67* 5.314E-01 l.044E-05 l.044E-05 11. 86 TL-208 72.80 ------ 2.14 1.594E+OO ------ Line Not Found ------
74.97 ------ 3.60 l.692E+OO ------ Line Not Found ------
84.79 ------ 1. 27 2.058E+OO ------ Line Not Found ------
252.45 ------ 0.80 2.021E+OO ------ Line Not Found ------
277.28 ------ 6.80 1.920E+OO ------ Line Not Found ------
510.61 ------ 21. 60 1.265E+OO ------ Line Not Found ------
583.02 26 86.00* 1.128E+OO 2.141E-07 3.521E-07 19.89 763.06 ------ 1. 64 8.744E-01 ------ Line Not Found ------
860.30 ------ 12.00 7.770E-01 ------ Line Not Found ------
PB-212 74.81 ------ 10.50 1.685E+OO ------ Line Not Found ------
77 .11 28 17.70 1.778E+OO 7.043E-07 7.061E-07 42.54 87.19 ------ 6.27 2.129E+OO ------ Line Not Found ------
90.13 ------ 1. 86 2.206E+OO ------ Line Not Found ------
115 .12 ------ 0.59 2.535E+OO ------ Line Not Found ------
238.58 69 43.60* 2.083E+OO 6.075E-07 6.090E-07 13.91 300.03 ------ 3.34 1.834E+OO ------ Line Not Found ------
BI-214 76.86 28 0.58 1.778E+OO 2.149E-05 2.326E-05 42.54 79.29 ------ 0.97 1.869E+OO ------ Line Not Found ------
609.31 25 46.10* 1.084E+OO 4.040E-07 4. 371E-07 23.64 665.44 ------ 1. 56 9.985E-01 ------ Line Not Found ------
768.35 ------ 4.88 8.685E-01 ------ Line Not Found ------
806.16 ------ 1. 23 8.283E-01 ------ Line Not Found ------
934.04 ------ 3.16 7.177E-01 ------ Line Not Found ------
1120.27 ------ 15.00 6.114E-01 ------ Line Not Found ------
1155 .18 ------ 1. 69 5.973E-01 ------ Line Not Found ------
1238.11 ------ 5.92 5.697E-01 ------ Line Not Found ------
1280.95 ------ 1. 47 5.585E-01 ------ Line Not Found ------
1377.66 ------ 4.02 5.401E-01 ------ Line Not Found ------
1385. 30 ------ 0.78 5.391E-01 ------ Line Not Found ------
1401. 48 ------ 1. 39 5.370E-01 ------ Line Not Found ------
1407.97 ------ 2.48 5.362E-01 ------ Line Not Found ------
1509.22 ------ 2.19 5.292E-01 ------ Line Not Found ------
1583.22 ------ 0.72 5.296E-01 ------ Line Not Found ------
1661. 26 ------ 1.15 5.351E-01 ------ Line Not Found ------
1729.58 ------ 3.05 5.442E-01 ------ Line Not Found ------
1764.49 ------ 15.90 5.503E-01 ------ Line Not Found ------
1847.41 ------ 2.12 5.694E-01 ------ Line Not Found ------
PB-214 53.17 ------ 1.10 5.543E-01 ------ Line Not Found ------
74.81 ------ 6.52 1.685E+OO ------ Line Not Found ------
77 .11 28 11. 00 1.778E+OO 1.133E-06 1. 202E-06 42.54 87.19 ------ 3.88 2.129E+OO ------ Line Not Found ------
90.13 ------ 1.15 2.206E+OO ------ Line Not Found ------
241. 92 ------ 7.46 2.067E+OO ------ Line Not Found ------
258.94 ------ 0.55 1.994E+OO ------ Line Not Found ------
295.09 28 19.20* 1.853E+OO 6.218E-07 6.593E-07 20.35 351. 87 38 37.10 l.662E+OO 4.945E-07 5.244E-07 17. 71 785.83 ------ 1. 09 8.495E-01 ------ Line Not Found ------
839.00 ------ 0.59 7. 964E-01 ------ Line Not Found ------
Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30426 Acquisition date 9-JUN-2014 20:43:46 Flag: "*" Keyline
Minimum Detectable Activity Report Page : 7 Sample ID 30426 Acquisition date 9-JUN-2014 20:43:46 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)
BE-7 4. 477.61 7.0081E-07 MN-54 4. 834.83 1.2235E-07 MN-56 1. 846.81 7.5700E-08 C0-57 13. 122.06 7.0423E-08 C0-58 2. 810.79 9.0057E-08 C0-60 o. 1332.50 3. 9271E-08 SB-124 1. 602.73 5.4748E-08 SB-125 7. 427.88 2. 7720E-07 CS-134 3. 604. 71 8.4560E-08 CS-137 4. 661. 66 1.1363E-07