ML20034E018
Text
Health Physics Sample Records Sample ID: 142509 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
14060614BD 09 NORTH LAYDOWN # 19 LCo_mmo_11J Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N
Contact:
COOPER, TERRY L Survey No:
Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 06/09/14 09:01 Comments: COUNT TO MDA Origin_]
Mat. SizeNolume: 1995 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
NORTH LAYDOWN # 19 I Collection Sample Tech: DYNES, WILLIAM J Sample Date: 06/06/14 12:05 Count Time: 900 (secs.)
Tritium Req: No Sample SizeNolume: 1995 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA lR_i,.s~_J Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: ji7' lLocation Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:
Stored By:, Date: 00/00/00 00:00 Sample Loe:
Other: COUNT TO MDA Material Loe:
06/19/2014 09:12 Page 1 of 3
Health Physics Sample Records Sample ID: 142509 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
14060614BD 09 NORTH LAYDOWN # 19
~aly~~J Geometry_____ MCA ID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date A_1L_marinelli_sand_ 30423 1995GR .000 NEESE, DAVID J 06/09/14 20:43
_l~~_!9e~-- Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 9.459E-6 1.124E-6 78.575% 40 0 PB-212 NT 4.986E-7 9.46E-8 4.142% 212 0 Bl-214 NT 6.355E-7 1.112E-7 r 5.279% 214 0 PB-214 NT 6.374E-7 1.576E-7 r 5.295% 214 0 AC-228 NT 8.077E-7 3.55E-7 r 6.709% 228 0 BE-7 AP 5.8235E-7 ~ 0.000% 7 0 MN-54 AP 1.3172E-7 ~ 0.000% 54 0 MN-56 AP 2.6287E-8 ~ 0.000% 56 0 C0-57 AP 7.6836E-8 ~ 0.000% 57 0 C0-58 AP 6.7365E-8 W- 0.000% 58 0 C0-60 AP 1.0085E-7 W 0.000% 60 0 SB-124 AP 5.168E-8 Iv 0.000% 124 0 SB-125 FP 1.9471E-7 ~ 0.000% 125 0 CS-134 FP 4.0754E-8 ~ 0.000% 134 0 CS-137 FP 1.0646E-7 rv 0.000% 137
~ ~ i s R~_~ew I Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/11/14 08:13 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments:
06/19/2014 09:12 Page 2 of 3
Health Physics Sample Records Sample ID: 142509 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140606148D 09 NORTH LAYDOWN # 19 Review/Approve HP Eng Review Reviewed: COOPER, TERRY L Date: 06/11/14 08:14 Comments:
Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:
Final Approval Approved: COOPER, TERRY L Date: 06/11/14 08:14 Comments:
06/19/2014 09:12 Page 3 of 3
- SONGS HEALTH PHYSICS REPORT 9-JUN-2014 20:38 *
- >>>>> SAMPLE PARAMETERS<<<<< *
- Title 14060614DD 09 NORTII LAYDOWN # 19 *
- ID 30423 Acquisition date: 9-JUN-2014 20:34:56. *
- Start Time: 9-JUN-2014 20:34:00. *
- Stop Time: 9-JUN-2014 20:34:00. Counting System U2GSP *
- Quantity 1.99500E+03 GR IHPS Sample Number: 142509 *
- Geometry A 11 marinelli_sand_l Analysis Library HP NATURAL *
- Operator: DAVID NEEBE *
- >>>>> A #41-TP11679B PARAMETERS<<<<< *
- Elapsed Live Time 0 00:03:00.43 Calibration 9-JUN-2014 19:32: *
- Elapsed Real Time 0 00:03:00.47 Energy Offset 2.30553E-01 *
- Deadtime 0.0% Energy Slope 4.99505E-01 *
- Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1. 00000 *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 76.98 19 42 1. 24 153.65 153 5 57.1 3.24E+OO BI-214 PB-212 PB-214 1 238.67 60 22 1.16 477.35 473 8 19.0 1.59E+OO PB-212 1 295.22 28 5 1. 31 590.57 585 11 24.7 4.39F.-01 PB-214 1 337.99 40 10 2.06 676.20 672 12 21. 6 1. 72E+OO AC-228 1 352.04 35 12 1. 77 704.34 700 10 24.4 8. llE-01 PB-214 1 609.24 39 3 1. 58 1219.27 1214 10 17.5 2.65E-01 BI-214 1 969. 65 13 7 1. 40 1940.86 1935 9 43.9 3.58E-01 AC-228 1 1460. 55 71 0 1. 77 2923.75 2918 12 11. 9 2.34E-01 K-40
Summary of Nuclide Activity Page : 2 Sample ID : 30423 Acquisition date 9-JUN-2014 20:34:56 Total number of lines in spectrum 8 Number of unidentified lines 0 Number of lines tentatively identified by NID 8 100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 l.28E+09Y 1. 00 9.459E-06 9.459E-06 1.124E-06 11. 88 A PB-212 10.64H 1. 00 4.973E-07 4.986E-07 0.946E-07 18. 96 A BI-214 19.90M 1. 09 5.839E-07 6.355E-07 1. 112E-07 17.50 A PB-214 26. SOM 1. 06 5.986E-07 6.374E-07 1.576E-07 24.73 A AC-228 6.13H 1. 00 8.039E-07 8.077E-07 3.550E-07 43.95 KA Total Activity l.194E-05 l.204E-05 Grand Total Activity : 1.194E-05 1. 204E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit
Unidentified Energy Lines Page : 3 Sample ID : 30423 Acquisition date 9-JUN-2014 20:34:56 None Flags: "T" Tentatively associated
Interference Report Page : 4 Sample ID : 30423 Acquisition date 9-JUN-2014 20:34:56 No interference correction performed
Nuclide Line Activity Report Page : 5 Sample ID : 30423 Acquisition date 9-JUN-2014 20:34:56 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 71 10.67* 5.314E-01 9.459E-06 9.459E-06 11. 88 PB-212 74.81 ------ 10.50 l.685E+OO ------ Line Not Found ------
77 .11 19 17.70 1.777E+OO 4.529E-07 4.541E-07 57.07 87.19 ------ 6.27 2.129E+OO ------ Line Not Found ------
90.13 ------ 1. 86 2.206E+OO ------ Line Not Found ------
115. 12 ------ 0.59 2.535E+OO ------ Line Not Found ------
238.58 60 43.60* 2.082E+OO 4.973E-07 4.986E-07 18. 96 300.03 ------ 3.34 1. 834E+OO ------ Line Not Found ------
BI-214 76.86 19 0.58 1.777E+OO 1.382E-05 l.504E-05 57.07 79.29 ------ 0.97 1. 869E+OO ------ Line Not Found ------
609.31 39 46.10* 1.084E+OO 5.839E-07 6.355E-07 17.50 665.44 ------ 1. 56 9.985E-01 ------ Line Not Found ------
768.35 ------ 4.88 8.685E-01 ------ Line Not Found ------
806.16 ------ 1. 23 8.283E-01 ------ Line Not Found ------
934.04 ------ 3.16 7.177E-01 ------ Line Not Found ------
1120. 27 ------ 15.00 6.114E-01 ------ Line Not Found ------
1155 .18 ------ 1. 69 5.973E-01 ------ Line Not Found ------
1238.11 ------ 5.92 5.697E-01 ------ Line Not Found ------
1280.95 ------ 1. 47 5.585E-01 ------ Line Not Found ------
------ Line Not Found ------
1377.66 1385.30
____ ..... _ 4.02 0.78 5.401E-01 5.391E-01 ------ Line Not Found ------
1401. 48 ------ 1. 39 5.370E-01 ------ Line Not Found ------
1407.97 ------ 2.48 5.362E-01 ------ Line Not Found ------
1509.22 ------ 2.19 5.292E-01 ------ Line Not Found ------
1583.22 ------ 0.72 5.296E-01 ------ Line Not Found ------
1661. 26 ------ 1.15 5.351E-01 ------ Line Not Found ------
1729.58 ------ 3.05 5.442E-01 ------ Line Not Found ------
1764.49 ------ 15.90 5.503E-01 ------ Line Not Found ------
1847.41 ------ 2.12 5.694E-01 ------ Line Not Found ------
PB-214 53.17 ------ 1.10 5.543E-01 ------ Line Not Found ------
74.81 ------ 6.52 1.685E+OO ------ Line Not Found ------
77 .11 19 11. 00 1.777E+OO 7.288E-07 7, 7 61E-07 57.07 87.19 ------ 3.88 2.129E+OO ------ Line Not Found ------
90.13 ------ 1.15 2.206E+OO ------ Line Not Found ------
241. 92 ------ 7.46 2.067E+OO ------ Line Not Found ------
258.94 ------ 0.55 1.994E+OO ------ Line Not Found ------
295.09 28 19.20* l.852E+OO 5.986E-07 6.374E-07 24.73 351.87 35 37.10 l.662E+OO 4.213E-07 4.487E-07 24.40 785.83 ------ 1. 09 8.495E-01 ------ Line Not Found ------
839.00 ------ 0.59 7.964E-01 ------ Line Not Found ------
AC-228 89. 96 ------ 3.40 2.201E+OO ------ Line Not Found ------
93.35 ------ 5.60 2.279E+OO ------ Line Not Found ------
99.55 ------ 1. 30 2.389E+OO ------ Line Not Found ------
105.36 ------ 2.00 2.463E+OO ------ Line Not Found ------
108.99 ------ 0.67 2.496E+OO ------ Line Not Found ------
129.03 ------ 2.90 2.562E+OO ------ Line Not Found ------
153.89 ------ 0.84 2. 4 96E+OO ------ Line Not Found ------
209.39 ------ 4.10 2.221E+OO ------ Line Not Found ------
216.24 ------ 0.80 2.187E+OO ------ Line Not Found ------
Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30423 Acquisition date 9-JUN-2014 20:34:56 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error 270.26 ------ 3.80 1.948E+OO ------ Line Not Found ------
328.07 ------ 3.50 1. 738E+OO ------ Line Not Found ------
338.42 40 12.40 1.705E+OO 1.432E-06 1. 438E-06 21. 62 340.94 ------ 0.52 l.696E+OO ------ Line Not Found ------
409.62 ------ 2.20 l.499E+OO ------ Line Not Found ------
463.10 ------ 4. 60 l.368E+OO ------ Line Not Found ------
562.65 ------ 1. 01 1.164E+OO ------ Line Not Found ------
581.52 ------ 3.00 1.131E+OO ------ Line Not Found ------
72 6. 63 ------ 0.87 9.173E-01 ------ Line Not Found ------
755.28 ------ 1. 32 8.833E-01 ------ Line Not Found ------
772.28 ------ 1. 09 8.641E-01 ------ Line Not Found ------
782.12 ------ 0.59 8.534E-01 ------ Line Not Found ------
794.79 ------ 4.60 8.400E-01 ------ Line Not Found ------
830.59 ------ 0.63 8.043E-01 ------ Line Not Found ------
835.60 ------ 1. 71 7.996E-01 ------ Line Not Found ------
840.44 ------ 0.94 7.951E-01 ------ Line Not Found ------
904.29 ------ 0.89 7.403E-01 ------ Line Not Found ------
911.16 ------ 29.00* 7.349E-01 ------ Line Not Found ------
964. 64 ------ 5.80 6. 962E-01 ------ Line Not Found ------
968. 97 13 17.40 6.929E-01 8.039E-07 8.077E-07 43.95 1246.60 ------ 0.57 5.673E-01 ------ Line Not Found ------
1459.19 ------ 1. 06 5.315E-01 ------ Line Not Found ------
1496. 00 ------ 1. 05 5.296E-01 ------ Line Not Found ------
1501. 44 ------ 0.58 5.294E-01 ------ Line Not Found ------
1580.30 ------ 0. 71 5.295E-01 ------ Line Not Found ------
1588.23 ------ 3.60 5.298E-01 ------ Line Not Found ------
1630.47 ------ 1. 95 5.324E-01 ------ Line Not Found ------
1638.10 ------ 0.54 5.330E-01 ------ Line Not Found ------
Flag: "*" = Keyline
Minimum Detectable Activity Report Page : 7 Sample ID 30423 Acquisition date 9-JUN-2014 20:34:56 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)
BE-7 3. 477.61 5.8235E-07 MN-54 6. 834.83 1.3172E-07 MN-56 0. 846.81 2.6287E-08 C0-57 18. 122.06 7.6836E-08 C0-58 1. 810.79 6.7365E-08 C0-60 1. 1332.50 1.0085E-07 SB-124 1. 602.73 5.1680E-08 SB-125 3. 427.88 1. 94 71E-07 CS-134 0. 604. 71 4.0754E-08 CS-137 4. 661.66 1.0646E-07