ML20034E006
Text
Health Physics Sample Re::...::c::...::o:_::._rd=-s=------------- ------------
Sample ID: 142475 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
1406038D 4 CULVERT# 7
~ommo_nJ Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N
Contact:
COOPER, TERRY L Survey No:
Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments:
Reviewed: DYNES, WILLIAM J Date: 06/05/14 07:14 Comments:
I_OrigLf!J Mat. SizeNolume: 1675 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
CULVERT# 7 l~ollection I Sample Tech: DYNES, WILLIAM J Sample Date: 06/03/14 08:11 Count Time: 900 (secs.)
Tritium Req: No Sample SizeNolume: 1821 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA I RLSSS
~-~~
Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: ~
[hQcation_l Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:
Stored By:, Date: 00/00/00 00:00 Sample Loe:
Other:
Material Loe:
06/19/2014 08:19 Page 1 of 3
Health Physics Sample Records Sample ID: 142475 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140603BD 4 CULVERT# 7
[A11aly~
G~CJm!!_ry MCA ID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date C_1L_marinelli_sand- 30368 1821 GR .000 PARK, MICHAEL C 06/05/14 15:58 Isotope Mode Activity Activity Uncert. _ LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.000011 1.38E-6 r 85.194% 40 0 TL-208 NT 2.051 E-7 6.16E-8 1.588% 208 0 PB-212 NT 4.561E-7 1.107E-7 3.532% 212 0 Bl-214 NT 4.495E-7 9.81E-8 r 3.481% 214 0 PB-214 NT 3.217E-7 6.81E-8 r 2.492% 214 0 AC-228 NT 4.793E-7 2.089E-7 r 3.712% 228 0 BE-7 AP 7.2411 E-7 Iv 0.000% 7 0 MN-54 AP 1.4203E-7 Iv 0.000% 54 0 MN-56 AP 1.1021 E-7 Iv 0.000% 56 0 C0-57 AP 6.5355E-8 Ii' 0.000% 57 0 C0-58 AP 8.0406E-8 Ii' 0.000% 58 0 C0-60 AP 3.9305E-8 Ii' 0.000% 60 0 SB-124 AP 6.9481E-8 Ii' 0.000% 124 0 SB-125 FP 2.0265E-7 w 0.000% 125 0 CS-134 FP 8.0955E-8 Iv 0.000% 134 0 CS-137 FP 1.1972E-7 w 0.000% 137
[_Analysis Review I Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/10/1414:36 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments:
06/19/2014 08:19 Page 2 of 3
Health Physics Sample Record-=-s_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
Sample ID: 142475 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140603BD 4 CULVERT# 7 R~view/~p_prove HP Review Reviewed: COOPER, TERRY L Date: 06/10/1414:36 Comments:
Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:
Final Aooroval Approved: COOPER, TERRY L Date: 06/10/14 14:36 Comments:
06/19/2014 08:19 Page 3 of 3
- SONGS HEALTH PHYSICS REPORT 5-JUN-2014 15:54 *
- >>>>> SAMPLE PARAMETERS<<<<< *
- Title 140603BD 4 CULVERT# 7 *
- ID 30368 Acquisition date: 5-JUN-2014 15:51:37. *
- Start Time: 5-JUN-2014 15:51:00. *
- Stop Time: 5-JUN-2014 15:51:00. Counting System U2GSP *
- Quantity l.82100E+03 GR IHPS Sample Number: 142475 *
- Geometry C 11 marinelli_sand_l Analysis Library HP NATURAL *
- Operator: MICHAEL PARK *
- >>>>> C #41-TP11750A PARAMETERS<<<<< *
- Elapsed Live Time 0 00:03:00.45 Calibration 5-JUN-2014 08:14: *
- Elapsed Real Time 0 00:03:00.49 Energy Offset -l.39807E-01 *
- Deadtime 0.0% Energy Slope 4.99820E-01 *
- Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1. 00000 *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1 238.67 50 28 1. 65 477.76 473 11 24.3 3.53E+OO PB-212 1 338.35 21 0 1. 89 677.17 674 7 20.7 2.26E-01 AC-228 1 352.14 23 0 1.18 704.77 701 7 21. 2 5.33E-01 PB-214 1 582.94 16 2 1. 63 1166.46 1163 8 30.0 l.28E+OO TL-208 1 609.60 26 2 2.45 1219.78 1215 10 21. 8 5.22E-01 BI-214 1 910.94 13 6 1. 54 1822.50 1817 9 43.6 1.lOE+OO AC-228 1 1460.99 79 5 2.07 2922.51 2916 11 12.5 9.35E-01 K-40
Summary of Nuclide Activity Page : 2 Sample ID : 30368 Acquisition date 5-JUN-2014 15:51:37 Total number of lines in spectrum 7 Number of unidentified lines 0 Number of lines tentatively identified by NID 7 100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 1.28E+09Y 1. 00 1.lOOE-05 1. lOOE-05 0.138E-05 12.55 A TL-208 3.05M 1. 59 1. 2 90E-07 2.051E-07 0.616E-07 30.04 A PB-212 10.64H 1. 00 4.550E-07 4.561E-07 1.107E-07 24.26 A BI-214 19.90M 1. 08 4.176E-07 4.495E-07 0.981E-07 21.83 A PB-214 26. SOM 1. 06 3.046E-07 3.217E-07 0.681E-07 21.16 KA AC-228 6.13H 1. 00 4.773E-07 4.793E-07 2.089E-07 43.59 A Total Activity : 1. 279E-05 l.291E-05 Grand Total Activity: 1.279E-05 1. 291E-05 Flags: "K" Keyline not found "M" Manually accepted "E" = Manually edited "A" Nuclide specific abn. limit
Unidentified Energy Lines Page : 3 Sample ID : 30368 Acquisition date 5-JUN-2014 15:51:37 None Flags: "T" Tentatively associated
Interference Report Page : 4 Sample ID : 30368 Acquisition date 5-JUN-2014 15:51:37 No interference correction performed
Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30368 Acquisition date 5-JUN-2014 15:51:37 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error AC-228 89. 96 ------ 3.40 2.051E+OO ------ Line Not Found ------
93.35 ------ 5.60 2.124E+OO ------ Line Not Found ------
99.55 ------ 1. 30 2.229E+OO ------ Line Not Found ------
105.36 ------ 2.00 2.301E+OO ------ Line Not Found ------
108.99 ------ 0.67 2.335E+OO ------ Line Not Found ------
129.03 ------ 2.90 2.414E+OO ------ Line Not Found ------
153.89 ------ 0.84 2.377E+OO ------ Line Not Found ------
209.39 ------ 4.10 2.168E+OO ------ Line Not Found ------
216.24 ------ 0.80 2.141E+OO ------ Line Not Found ------
270.26 ------ 3.80 1.941E+OO ------ Line Not Found ------
328.07 ------ 3.50 1.756E+OO ------ Line Not Found ------
338.42 21 12.40 1. 725E+OO 8.097E-07 8.129E-07 20.70 340.94 ------ 0.52 1. 718E+OO ------ Line Not Found ------
409.62 ------ 2.20 l.531E+OO ------ Line Not Found ------
463.10 ------ 4.60 l.401E+OO ------ Line Not Found ------
562.65 ------ 1. 01 1.195E+OO ------ Line Not Found ------
581.52 ------ 3.00 1.160E+OO ------ Line Not Found ------
72 6. 63 0.87 9.382E-Ol ------ Line Not Found ------
755.28 ------ 1. 32 9.027E-01 ------ Line Not Found ------
772. 28 ------ 1. 09 8.827E-01 ------ Line Not Found ------
782.12 ------ 0.59 8. 716E-01 ------ Line Not Found ------
794.79 4.60 8.576E-01 ------ Line Not Found ------
830.59 ------ 0.63 8.205E-Ol ------ Line Not Found ------
835.60 1. 71 8.155E-01 ------ Line Not Found ------
840.44 0.94 8.108E-01 ------ Line Not Found ------
904.29 0.89 7.542E-01 ------ Line Not Found ------
911.16 13 29.00* 7.489E-Ol 4.773E-07 4.793E-07 43.59 964.64 5.80 7.091E-01 ------ Line Not Found ------
968.97 17.40 7.061E-01 ------ Line Not Found ------
1246.60 0.57 5.825E-01 ------ Line Not Found ------
1459.19 1. 06 5.560E-01 ------ Line Not Found ------
1496.00 1. 05 5.563E-Ol ------ Line Not Found ------
1501. 44 0.58 5.565E-01 ------ Line Not Found ------
1580.30 ------ 0. 71 5.624E-01 ------ Line Not Found ------
1588.23 3.60 5.634E-01 ------ Line Not Found ------
1630.47 1. 95 5. 696E-Ol ------ Line Not Found ------
1638.10 0.54 5.709E-01 ------ Line Not Found ------
Flag: "*" = Keyline
- r J '
Minimum Detectable Activity Report Page : 7 Sample ID 30368 Acquisition date 5-JUN-2014 15:51:37 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)
BE-7 4. 477.61 7. 2411E-07 MN-54 6. 834.83 1.4203E-07 MN-56 3. 846.81 l.1021E-07 C0-57 9. 122.06 6.5355E-08 C0-58 1. 810.79 8.0406E-08 C0-60 0. 1332.50 3.9305E-08 SB-124 2. 602.73 6.9481E-08 SB-125 3. 427.88 2.0265E-07 CS-134 3. 604. 71 8.0955E-08 CS-137 5. 661.66 1.1972E-07