ML20034E000
Text
Health Physics Sample Records Sample ID: 142462 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
1405298D 32 STARYARD SURVEY PT 32 lcommonl Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N
Contact:
COOPER, TERRY L Survey No:
Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 06/04/14 07:47 Comments:
I_Qrl9k!.J Mat. SizeNolume: 2135 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
STARYARD SURVEY PT 32 I Collection I Sample Tech: DYNES, WILLIAM J Sample Date: 05/29/1412:40 Count Time: 900 (secs.)
Tritium Req: No Sample SizeNolume: 2135 GRAMS Instructions:
Comments: COUNT TO MDA IRLSSSI Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: Ji7'
[1_ocation Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:
Stored By:, Date: 00/00/00 00:00 Sample Loe:
Other:
Material Loe:
06/18/201413:53 Page 1 of 3
Health Physics Sample Records Sample ID: 142462 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
1405298D 32 STARYARD SURVEY PT 32 Analysis Geometry MCAID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date C_ 1L_ marinelli_sand- 30365 2135GR .000 PARK, MICHAEL C 06/05/14 15:43 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.000013841.31E-6 r 84.416% 40 0 TL-208 NT 3.006E-7 5.99E-8 r 1.833% 208 0 PB-212 NT 5.803E-7 1.164E-7 r 3.540% 212 0 81-214 NT 3.662E-7 1.136E-7 r 2.234% 214 0 PB-214 NT 6.745E-7 2.323E-7 r 4.114% 214 0 AC-228 NT 6.333E-7 1.779E-7 r 3.863% 228 0 BE-7 AP 6.649E-7 Iv' 0.000% 7 0 MN-54 AP 1.1559E-7 IV 0.000% 54 0 MN-56 AP 1.1358E-7 IV 0.000% 56 0 C0-57 AP 8.7728E-8 Iv' 0.000% 57 0 C0-58 AP 9.4446E-8 IV 0.000% 58 0 C0-60 AP 1.0788E-7 IV 0.000% 60 0 SB-124 AP 9.7855E-8 IV 0.000% 124 0 SB-125 FP 1.8441E-7 iv* 0.000% 125 0 CS-134 FP 7.7676E-8 IV 0.000% 134 0 CS-137 FP 1.0764E-7 Iv' 0.000% 137 Analysis Review Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/10/1413:30 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments:
06/18/201413:53 Page 2 of3
Health Physics Sample Records Sample ID: 142462 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140529BD 32 STARYARD SURVEY PT 32 I Review/Approve I HP Eng Review Reviewed: COOPER, TERRY L Date: 06/10/1413:31 Comments:
Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:
Final Approval Approved: COOPER, TERRY L Date: 06/10/14 13:31 Comments:
06/18/201413:53 Page 3 of 3
- SONGS HEALTH PHYSICS REPORT 5-JUN-2014 15:40 *
- >>>>> SAMPLE PARAMETERS<<<<< *
- Title 140529BD 32 STARYARD SURVEY PT 32 *
- ID 30365 Acquisition date: 5-JUN-2014 15:37:10. *
- Start Time: 5-JUN-2014 15:37:00. *
- Stop Time: 5-JUN-2014 15:37:00. Counting System U2GSP *
- Quantity 2.13500E+03 GR IHPS Sample Number: 142462 *
- Geometry C lL marinelli_sand_l Analysis Library HP NATURAL *
- Operator: MICHAEL PARK *
- >>>>> C #41-TP11750A PARAMETERS<<<<< *
- Elapsed Live Time 0 00:03:00.43 Calibration 5-JUN-2014 08:14: *
- Elapsed Real Time 0 00:03:00.50 Energy Offset -l.39807E-01 *
- Deadtime 0.0% Energy Slope 4.99820E-01 *
- Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1. 00000 *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 77.26 41 49 o. 96 154.85 152 7 32.4 4.90E+OO BI-214 PB-212 PB-214 1 87.31 40 39 1. 97 174.95 172 8 30.5 8.69E-01 PB-212 PB-214 1 238.39 74 43 1. 21 477.21 473 9 20.0 2.99E+OO PB-212 l 295.14 33 24 1. 42 590.74 585 11 34.4 1.66E+OO PB-214 1 339.32 22 15 0. 96 679.12 673 10 36.4 8.17E+OO AC-228 1 351. 95 50 10 1. 55 704.40 700 12 18.9 3.49E-01 PB-214 1 511.32 17 5 2.99 1023.20 1018 10 32.7 1. 7 9E+OO TL-208 1 583.29 30 2 2.00 1167.15 1163 9 19.9 3.70E-01 TL-208 1 609.36 25 11 1. 35 1219.31 1215 9 31. 0 l.76E+OO BI-214 1 911.11 20 5 1. 92 1822.84 1818 9 28.1 1. OlE-01 AC-228 1 1460.70 117 0 1. 96 2921. 93 2916 13 9.4 9.35E-Ol K-40
Summary of Nuclide Activity Page : 2 Sample ID : 30365 Acquisition date 5-JUN-2014 15:37:10 Total number of lines in spectrum 11 Number of unidentified lines 0 Number of lines tentatively identified by NID 11 100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 1.28E+09Y 1. 00 1. 384E-05 l.384E-05 0.131E-05 9.44 A TL-208 3.05M 1. 43 2.095E-07 3.006E-07 0.599E-07 19.92 A PB-212 10.64H 1. 00 5.793E-07 5.803E-07 1.164E-07 20.05 A BI-214 19.90M 1. 06 3.456E-07 3.662E-07 l .136E-07 31. 01 A PB-214 26.SOM 1. 04 6.461E-07 6.745E-07 2.323E-07 34.44 A AC-228 6.13H 1. 00 6.313E-07 6.333E-07 1. 779E-07 28.09 A Total Activity 1.626E-05 l.640E-05 Grand Total Activity : 1.626E-05 l.640E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit
Unidentified Energy Lines Page : 3 Sample ID : 30365 Acquisition date 5-JUN-2014 15:37:10 None Flags: "T" Tentatively associated
Interference Report Page : 4 Sample ID : 30365 Acquisition date 5-JUN-2014 15:37:10 No interference correction performed
Nuclide Line Activity Report Page : 5 Sample ID : 30365 Acquisition date 5-JUN-2014 15:37:10 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 117 10.67* 5.560E-01 1.384E-05 1.384E-05 9.44 TL-208 72.80 ------ 2.14 1.486E+OO ------ Line Not Found ------
74.97 ------ 3.60 l.577E+OO ------ Line Not Found ------
84.79 ------ 1. 27 1.917E+OO ------ Line Not Found ------
252.45 ------ 0.80 2.004E+OO ------ Line Not Found ------
277.28 ------ 6.80 l.917E+OO Line Not Found ------
510.61 17 21. 60 1. 296E+OO 4.374E-07 6.275E-07 32.66 583.02 30 86.00* 1.157E+OO 2.095E-07 3.006E-07 19.92 763.06 ------ 1. 64 8.934E-01 ------ Line Not Found ------
860.30 ------ 12.00 7.922E-01 ------ Line Not Found ------
PB-212 74.81 ------ 10.50 1.570E+OO ------ Line Not Found ------
77 .11 41 17.70 1.666E+OO 9.675E-07 9.692E-07 32.41 87.19 40 6.27 1.986E+OO 2.258E-06 2.262E-06 30. 46 90 .13 ------ 1. 86 2.055E+OO ------ Line Not Found ------
115 .12 ------ 0.59 2.376E+OO ------ Line Not Found ------
238.58 74 43.60* 2.056E+OO 5.793E-07 5.803E-07 20.05 300.03 ------ 3.34 1.843E+OO Line Not Found ------
BI-214 76. 86 41 0.58 1.666E+OO 2.952E-05 3.128E-05 32.41 79.29 ------ 0.97 l.741E+OO ------ Line Not Found ------
609.31 25 46.10* 1. 112E+OO 3.456E-07 3.662E-07 31. 01 665.44 ------ 1. 56 1.023E+OO ------ Line Not Found ------
768.35 ------ 4.88 8.873E-01 ------ Line Not Found ------
806.16 ------ 1. 23 8.454E-01 ------ Line Not Found ------
934.04 ------ 3.16 7.310E-01 ------ Line Not Found ------
1120.27 ------ 15.00 6.242E-01 ------ Line Not Found ------
1155 .18 ------ 1. 69 6.105E-01 Line Not Found ------
1238 .11 ------ 5.92 5.846E-01 Line Not Found ------
1280.95 ------ 1. 47 5.747E-01 Line Not Found ------
1377.66 ------ 4.02 5.602E-01 ------ Line Not Found ------
1385.30 ------ 0.78 5.595E-01 ------ Line Not Found ------
1401.48 ------ 1. 39 5.583E-01 ------ Line Not Found ------
1407.97 ------ 2.48 5.578E-01 ------ Line Not Found ------
1509.22 ------ 2.19 5.568E-01 ------ Line Not Found ------
1583.22 ------ 0. 72 5.628E-01 ------ Line Not Found ------
1661.26 ------ 1.15 5.753E-01 Line Not Found ------
1729.58 ------ 3.05 5.918E-01 Line Not Found ------
1764.49 ------ 15.90 6.023E-01 ------ Line Not Found ------
1847.41 ------ 2.12 6.331E-01 ------ Line Not Found ------
PB-214 53.17 ------ 1.10 5.203E-01 ------ Line Not Found ------
74.81 ------ 6.52 l.570E+OO ------ Line Not Found ------
77 .11 41 11. 00 l.666E+OO 1.557E-06 l.625E-06 32.41 87.19 40 3.88 1.986E+OO 3.649E-06 3.809E-06 30.46 90 .13 ------ 1.15 2.055E+OO ------ Line Not Found ------
241. 92 ------ 7.46 2.043E+OO Line Not Found ------
258.94 ------ 0.55 l.981E+OO ------ Line Not Found ------
295.09 33 19.20* 1.858E+OO 6. 4 61E-07 6.745E-07 34.44 351. 87 50 37.10 1.686E+OO 5.614E-07 5.861E-07 18.85 785.83 ------ 1. 09 8.674E-01 ------ Line Not Found ------
839.00 ------ 0.59 8.122E-01 ------ Line Not Found ------
Nuclide Line Activity Report ( continued) Page : 6 Sample ID : 30365 Acquisition date 5-JUN-2014 15:37:10 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error AC-228 89. 96 ------ 3.40 2.051E+OO ------ Line Not Found ------
93.35 ------ 5.60 2.124E+OO ------ Line Not Found ------
99.55 ------ 1. 30 2.229E+OO ------ Line Not Found ------
105.36 ------ 2.00 2.301E+OO ------ Line Not Found ------
108.99 ------ 0. 67 2.335E+OO ------ Line Not Found ------
129.03 ------ 2.90 2.414E+OO ------ Line Not Found ------
153.89 ------ 0.84 2.377E+OO ------ Line Not Found ------
209.39 ------ 4.10 2.168E+OO ------ Line Not Found ------
216.24 ------ 0.80 2.141E+OO ------ Line Not Found ------
270.26 ------ 3.80 1.941E+OO ------ Line Not Found ------
328.07 ------ 3.50 1.756E+OO ------ Line Not Found ------
338.42 22 12.40 l.722E+OO 7.312E-07 7.335E-07 36.36 340.94 ------ 0.52 1. 718E+OO ------ Line Not Found ------
409.62 ------ 2.20 1.531E+OO ------ Line Not Found ------
463.10 ------ 4.60 1.401E+OO ------ Line Not Found ------
562.65 ------ 1. 01 1.195E+OO ------ Line Not Found ------
581.52 ------ 3.00 1.160E+OO ------ Line Not Found ------
72 6. 63 ------ 0.87 9.382E-01 ------ Line Not Found ------
755.28 ------ 1. 32 9.027E-01 ------ Line Not Found ------
772. 28 ------ 1. 09 8.827E-01 ------ Line Not Found ------
782.12 ------ 0.59 8. 716E-01 ------ Line Not Found ------
794.79 ------ 4.60 8.576E-01 ------ Line Not Found ------
830.59 ------ 0.63 8.205E-01 ------ Line Not Found ------
835.60 ------ 1. 71 8.155E-01 ------ Line Not Found ------
840.44 ------ 0.94 8.108E-01 ------ Line Not Found ------
904.29 ------ 0.89 7.542E-01 ------ Line Not Found ------
911.16 20 29.00* 7.487E-01 6.313E-07 6.333E-07 28.09 964.64 ------ 5.80 7.091E-01 ------ Line Not Found ------
968. 97 ------ 17.40 7.061E-01 ------ Line Not Found ------
1246.60 ------ 0.57 5.825E-01 ------ Line Not Found ------
1459.19 ------ 1. 06 5.560E-01 ------ Line Not Found ------
1496.00 ------ 1. 05 5.563E-01 ------ Line Not Found ------
1501.44 ------ 0.58 5.565E-01 ------ Line Not Found ------
1580.30 ------ 0. 71 5.624E-01 ------ Line Not Found ------
1588.23 ------ 3.60 5.634E-Ol ------ Line Not Found ------
1630.47 ------ 1. 95 5.696E-01 ------ Line Not Found ------
1638.10 ------ 0.54 5.709E-01 ------ Line Not Found ------
Flag: "*" = Keyline
Minimum Detectable Activity Report Page : 7 Sample ID 30365 Acquisition date 5-JUN-2014 15:37:10 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)
BE-7 5. 477.61 6.6490E-07 MN-54 5. 834.83 1.1559E-07 MN-56 0. 1810.80 l.1358E-07 C0-57 24. 122.06 8. 7728E-08 C0-58 3. 810.79 9.4446E-08 C0-60 2. 1173.24 l.0788E-07 SB-124 7. 602.73 9.7855E-08 SB-125 4. 427.88 1.8441E-07 CS-134 4. 604. 71 7.7676E-08 CS-137 5. 661. 66 l.0764E-07