ML20034D998

From kanterella
Jump to navigation Jump to search
Sy South PT 27 - Health Physics Sample Records
ML20034D998
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 06/18/2014
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034D998 (10)


Text

Health Physics Sample Records Sample ID: 142460 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140529BD 27 STARYARD SURVEY PT 27 ICommonl Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N

Contact:

COOPER, TERRY L Survey No:

Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments:

Reviewed: DYNES, WILLIAM J Date: 06/04/14 07:38 Comments:

I Origin ~I Mat. SizeNolume: 1714 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00

Description:

STARYARD SURVEY PT 27 1eo11ectionl Sample Tech: DYNES, WILLIAM J Sample Date: 05/29/1412:15 Count Time: 900 (secs.)

Tritium Req: No Sample SizeNolume: 1714 GRAMS Instructions:

Comments: COUNT TO MDA I Ri..SSS I Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: ~

ILocation I Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:

Stored By:, Date: 00/00/00 00:00 Sample Loe:

Other:

Material Loe:

06/18/2014 13:58 Page 1 of 3

Health Physics Sample Records Sample ID: 142460 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized:

Description:

140529BD 27 STARYARD SURVEY PT 27

]Analysisl Geometry_ _ _ _ MCAID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date B_1L_marinelli_sand- 30341 1714GR .000 PARK, MICHAEL C 06/04/14 15:48

__ Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.00001073 1.62E-6 r 5.037% 40 0 TL-208 NT 2.971E-7 8.58E-8 r 0.139% 208 0 PB-212 NT 5.584E-7 9.52E-8 r 0.262% 212 0 Bl-214 NT 6.36E-7 1.181E-7 r 0.299% 214 0 PB-214 NT 7.529E-7 1.325E-7 r 0.353% 214 0 RN-222 NT 0.0001971 0.0000467 r 92.518% 222 0 RA-224 NT 2.966E-6 7.94E-7 r 1.392% 224 0 BE-7 AP 1.151E-6 Iv 0.000% 7 0 MN-54 AP 1.2421E-7 Iv 0.000% 54 0 MN-56 AP 1.0188E-7 Iv 0.000% 56 0 C0-57 AP 8.9216E-8 Iv 0.000% 57 0 C0-58 AP 1.5692E-7 Iv 0.000% 58 0 C0-60 AP 1.3393E-7 Iv 0.000% 60 0 SB-124 AP 7.3627E-8 Iv 0.000% 124 0 SB-125 FP 1.8204E-7 Iv 0.000% 125 0 CS-134 FP 1.0826E-7 Iv 0.000% 134 0 CS-137 FP 1.3883E-7 Iv 0.000% 137 I Analysis Review Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/10/14 13:29 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:

Comments:

06/18/2014 13:58 Page 2 of 3

Health Physics Sample Records Sample ID: 142460 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

1405298D 27 STARYARD SURVEY PT 27 I Review/Approve I HP Eng_ Review Reviewed: COOPER, TERRY L Date: 06/10/1413:29 Comments:

Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:

Final Aep_roval Approved: COOPER, TERRY L Date: 06/10/14 13:29 Comments:

06/18/2014 13:58 Page 3 of 3

                                                                                                  • *******************x***********
  • SONGS HEALTH PHYSICS REPORT 4-JUN-2014 15:42 *
  • >>>>> SAMPLE PARAMETERS<<<<< *
  • Title 1405298D 27 STARYARD SURVEY PT 27 *
  • ID 30341 Acquisition date: 4-JUN-2014 15:39:42. *
  • Start Time: 4-JUN-2014 15:39:00. *
  • Stop Time: 4-JUN-2014 15:39:00. Counting System U2GSP *
  • Quantity 1.71400E+03 GR IHPS Sample Number: 142460 *
  • Geometry B 11 marinelli_sand_l Analysis Library HP NATURAL *
  • Operator: MICHAEL PARK *
  • >>>>> B #42-TP11663A PARAMETERS<<<<< *
  • Elapsed Live Time 0 00:03:00.47 Calibration 3-JUN-2014 20:43: *
  • Elapsed Real Time 0 00:03:00.50 Energy Offset -4.80178E-01 *
  • Deadtime 0.0% Energy Slope 5.00073E-01 *
  • Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1.00000 *
  • Half Life Ratio 8.00000 Sensitivity 5.00000
  • Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 5 238.47 50 8 1. 25 477.82 473 15 17.1 9.45E-01 PB-212 5 241. 58 24 4 1. 78 484.04 473 15 26.8 RA-224 PB-214 1 352.00 42 3 2.03 704.85 699 12 17.6 6.42E-01 PB-214 1 510.59 16 0 1. 50 1021.97 1018 7 23.7 2.46E-01 RN-222 TL-208 1 583.65 17 2 1. 40 1168.08 1163 8 28.9 5.26E-01 TL-208 1 609.45 27 0 2 .11 1219.65 1215 9 18.6 5.07E-Ol BI-214 1 1460.99 55 2 1. 82 2922.42 2916 11 15.1 1. 8 6E+OO K-40

Summary of Nuclide Activity Page : 2 Sample ID : 30341 Acquisition date 4-JUN-2014 15:39:42 Total number of lines in spectrum 7 Number of unidentified lines 0 Number of lines tentatively identified by NID 7 100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 1.2BE+09Y 1. 00 1.073E-05 1.073E-05 0.162E-05 15.12 A TL-208 3.05M 1. 62 1.837E-07 2. 971E-07 0.858E-07 28.87 A PB-212 10.64H 1. 00 5. 571E-07 5.584E-07 0.952E-07 17.05 A BI-214 19.90M 1. 08 5.892E-07 6.360E-07 1.181E-07 18.57 A PB-214 26.80M 1. 06 7 .113E-07 7.529E-07 1. 325E-07 17.60 KA RN-222 3.83D 1. 00 1.970E-04 l.971E-04 0.467E-04 23.69 A RA-224 3.66D 1. 00 2. 965E-06 2.966E-06 0.794E-06 26.76 A Total Activity 2.128E-04 2 .130E-04 Grand Total Activity : 2.128E-04 2.130E-04 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit

Unidentified Energy Lines Page : 3 Sample ID : 30341 Acquisition date 4-JUN-2014 15:39:42 None Flags: "T" Tentatively associated

Interference Report Page : 4 Sample ID : 30341 Acquisition date 4-JUN-2014 15:39:42 No interference correction performed

Nuclide Line Activity Report Page : 5 Sample ID : 30341 Acquisition date 4-JUN-2014 15:39:42 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 55 10.67* 4, 211E-01 1.073E-05 1. 07 3E-05 15.12 TL-208 72. 80 ------ 2.14 l.070E+OO Line Not Found ------

74.97 ------ 3.60 1.156E+OO Line Not Found ------

84.79 ------ 1. 27 l.506E+OO Line Not Found ------

252.45 ------ 0.80 1.745E+OO Line Not Found ------

277.28 ------ 6.80 l.645E+OO Line Not Found ------

510.61 16 21. 60 l.035E+OO 6.386E-07 1.033E-06 23.69 583.02 17 86.00* 9.190E-01 1.837E-07 2. 971E-07 28.87 763.06 ------ 1. 64 7.126E-01 ------ Line Not Found ------

860.30 ------ 12.00 6.341E-01 ------ Line Not Found ------

PB-212 74.81 ------ 10.50 1.150E+OO Line Not Found ------

77 .11 ------ 17.70 l.239E+OO Line Not Found -*-----

87.19 ------ 6.27 1.579E+OO Line Not Found ------

90 .13 ------ 1. 86 1.662E+OO Line Not Found ------

115 .12 ------ 0.59 2.085E+OO Line Not Found ------

238.58 50 43.60* l.805E+OO 5.571E-07 5.584E-07 17.05 300.03 ------ 3.34 1.562E+OO ------ Line Not Found ------

BI-214 76.86 ------ 0.58 1.229E+OO ------ Line Not Found ------

79.29 ------ 0.97 1.320E+OO ------ Line Not Found ------

609.31 27 46.10* 8.831E-Ol 5.892E-07 6.360E-07 18.57 665.44 ------ 1. 56 8.131E-01 Line Not Found ------

768.35 ------ 4.88 7.078E-01 Line Not Found ------

806.16 ------ 1. 23 6.754E-01 Line Not Found ------

934.04 ------ 3.16 5.861E-01 Line Not Found ------

1120.27 ------ 15.00 4.982E-01 ------ Line Not Found ------

1155. 18 ------ 1. 69 4.860E-01 ------ Line Not Found ------

1238. 11 ------ 5.92 4.615E-01 ------ Line Not Found ------

1280.95 ------ 1. 4 7 4.510E-01 ------ Line Not Found ------

1377.66 ------ 4.02 4.323E-01 ------ Line Not Found ------

1385.30 ------ 0.78 4. 311E-01 Line Not Found ------

1401.48 ------ 1. 39 4.287E-01 Line Not Found ------

1407.97 ------ 2.48 4.277E-01 Line Not Found ------

1509.22 ------ 2.19 4.165E-01 Line Not Found ------

1583.22 ------ 0. 72 4.120E-Ol ------ Line Not Found ------

1661. 26 ------ 1.15 4.103E-01 ------ Line Not Found -*-----

1729.58 ------ 3.05 4 .114E-01 ------ Line Not Found ------

1764.49 ------ 15.90 4.128E-01 ------ Line Not Found ------

1847.41 ------ 2.12 4.187E-01 Line Not Found ------

PB-214 53.17 ------ 1.10 2.929E-01 Line Not Found ------

74.81 ------ 6.52 1.150E+OO Line Not Found ------

77 .11 ------ 11. 00 1.239E+OO Line Not Found ------

87.19 ------ 3.88 1.579E+OO ------ Line Not Found ------

90.13 ------ 1.15 1.662E+OO ------ Line Not Found ------

241. 92 24 7.46 1.792E+OO 1.550E-06 1.640E-06 26.76 258.94 ------ 0.55 1. 718E+OO ------ Line Not Found ------

295.09 ------ 19.20* 1.579E+OO ------ Line Not Found ------

351. 87 42 37.10 1.395E+OO 7 .113E-07 7.529E-07 17.60 785.83 ------ 1. 09 6.925E-01 Line Not Found --*----

839.00 ------ 0.59 6.497E-01 ------ Line Not Found ------

Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30341 Acquisition date 4-JUN-2014 15:39:42 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error RN-222 510.00 16 0.07* 1.035E+OO 1.970E-04 1. 971E-04 23.69 RA-224 83.79 0.20 1. 474E+OO ------ Line Not Found ------

240.76 24 3.90* 1.792E+OO 2. 965E-06 2.966E-06 26. 76 Flag: "*" Keyline

Minimum Detectable Activity Report Page : 7 Sample ID 30341 Acquisition date 4-JUN-2014 15:39:42 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)

BE-7 7. 477.61 1.1510E-06 MN-54 2. 834.83 l.2421E-07 MN-56 1. 846.81 l.0188E-07 C0-57 12. 122.06 8.9216E-08 C0-58 4. 810.79 1.5692E-07 C0-60 1. 1173.24 1.3393E-07 SB-124 1. 602.73 7.3627E-08 SB-125 1. 427.88 1.8204E-07 CS-134 3. 604. 71 l.0826E-07 CS-137 3. 661.66 l.3883E-07