Health Physics Sample Records Sample ID: 142452 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
1405308D info 1 STARYARD
!Common!
Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: Y
Contact:
COOPER, TERRY L Survey No:
Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 05/30/14 12:13 Comments:
Origin ]
Mat. SizeNolume: 2128 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
I Collection Sample Tech: DYNES, WILLIAM J Sample Date: 05/30/1410:45 Count Time: 900 (secs.)
Tritium Req: No Sample SizeNolume: 2128 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA L~LS$~
Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: ji7' lfocatfonl Unit: NON-UNIT RE Area: Elev: 100 Room: Depth: (in.) Equip ID:
Stored By:, Date: 00/00/00 00:00 Sample Loe:
Other:
Material Loe:
06/18/2014 14:18 Page 1 of 3
Health Physics Sample Records Sample ID: 142452 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
1405308D info 1 STARYARD Analysis Geometry MCAID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date 8_1L_marinelli_sand_ 30282 2128GR .000 HENDERSON, JOE C 05/30/14 13:13
~ t o ~ Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.00002515 2.03E-6 r 64.368% 40 0 TL-208 NT 5.34E-7 1.667E-7 r 1.367% 208 0 P8-212 NT 1.776E-6 1.49E-7 r 4.545% 212 0 81-214 NT 1.154E-6 1.51E-7 r 2.954% 214 0 P8-214 NT 1.475E-6 3.15E-7 r 3.775% 214 0 RA-224 NT 6.969E-6 2.046E-6 r 17.836% 224 0 AC-228 NT 2.014E-6 2.99E-7 r 5.155% 228 0 8E-7 AP 1.0455E-6 w 0.000% 7 0 MN-54 AP 1.7105E-7 w 0.000% 54 0 MN-56 AP 2.1351 E-7 Iv" 0.000% 56 0 C0-57 AP 1.3212E-7 Jv 0.000% 57 0 C0-58 AP 1.4299E-7 Iv 0.000% 58 0 C0-60 AP 1.726E-7 Jv 0.000% 60 0 S8-124 AP 9.8444E-8 Iv 0.000% 124 0 S8-125 FP 3.4734E-7 Jv 0.000% 125 0 CS-134 FP 1.4206E-7 Iv 0.000% 134 0 CS-137 FP 1.2134E-7 Jv 0.000% 137 I Analysis Review I Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/10/1410:32 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments:
06/18/2014 14:18 Page 2 of 3
Health Physics Sample Records Sample ID: 142452 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140530BD info 1 STARYARD I Review/ApproveJ HP Review Reviewed: COOPER, TERRY L Date: 06/10/1410:33 Comments: Energy peak at 332 keV is not due to plant-produced radionuclide Disposition Disposition: OTHER Result Sample contains only natural isotopes Remarks:
Final Approval Approved: COOPER, TERRY L Date: 06/10/1410:33 Comments:
06/18/201414:18 Page 3 of 3
- SONGS HEALTH PHYSICS REPORT 30-MAY-2014 13:02 *
- >>>>> SAMPLE PARAMETERS<<<<< *
- Title 140530BD INFO 1 STARYARD *
- ID 30282 Acquisition date: 30-MAY-2014 12:58:58 *
- Start Time: 30-MAY-2014 12:58:00 *
- Stop Time: 30-MAY-2014 12:58:00 Counting System U2GSP *
- Quantity 2.12800E+03 GR IHPS Sample Number: 142452 *
- Geometry B 11 marinelli sand 1 Analysis Library HP NATURAL *
- Operator: JOE HENDERSON *
- >>>>> B #42-TP11663A PARAMETERS<<<<< *
- Elapsed Live Time 0 00:03:00.36 Calibration 29-MAY-2014 21:44 *
- Elapsed Real Time 0 00:03:00.46 Energy Offset -1.81343E-02 *
- Deadtime 0.1% Energy Slope 4.99764E-01 *
- Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1.00000 *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 77.27 48 105 1. 21 154.64 151 7 38.2 3.34E+OO BI-214 PB-212 PB-214 5 238.68 198 24 1. 20 477.62 473 19 8.4 1. 55E+OO PB-212 5 241. 55 69 34 2.02 483.36 473 19 29.4 RA-224 PB-214 1 295.45 60 25 1. 40 591. 21 587 10 21. 4 1.56E+OO PB-214 1 328.22 25 13 1. 48 656.79 652 16 32.6 9.94E-01 AC-228 1 332.19 18 5 1. 48 664.74 652 16 32.3 1 338.75 43 11 2.14 677.87 673 14 25.4 1.87E+OO AC-228 1 352.10 77 33 1. 24 704.58 699 11 18.4 2.0lE+OO PB-214 1 583.32 35 20 1. 32 1167. 25 1162 13 31. 2 6.64E-01 TL-208 1 609.39 61 0 1. 74 1219.43 1214 11 13.1 7.51E-01 BI-214 1 911. 04 50 0 2.31 1823.03 1817 14 14.8 5.12E-01 AC-228 1 968. 81 26 7 2.05 1938.63 1933 13 29. 0 7.99E-01 AC-228 1 1460.71 160 0 2.04 2922.99 2915 14 8.1 8.0lE-01 K-40
Summary of Nuclide Activity Page : 2 Sample ID : 30282 Acquisition date 30-MAY-2014 12:58:58 Total number of lines in spectrum 13 Number of unidentified lines 1 Number of lines tentatively identified by NID 12 92.31%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 l.28E+09Y 1.00 2.515E-05 2.515E-05 0. 203E-*05 8.05 A TL-208 3.05M 1.72 3.104E-07 5.340E-07 1.667E-07 31.22 A PB-212 10.64H 1.00 l.772E-06 1.776E-06 0.149E-06 8.41 A BI-214 19.90M 1.09 l.059E-06 1.154E-06 0 .151E-06 13.06 A PB-214 26.80M 1. 07 l.384E-06 l.475E-06 0.315E-06 21.36 A RA-224 3.66D 1. 00 6.967E-06 6.969E-06 2.046E-06 29.36 A AC-228 6.13H 1. 00 2.005E-06 2.014E-06 0.299E-06 14.83 A Total Activity 3.865E-05 3.907E-05 Grand Total Activity : 3.865E-05 3.907E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit
Unidentified Energy Lines Page : 3 Sample ID : 30282 Acquisition date : 30-MAY-2014 12:58:58 It Energy Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err %Eff Flags 1 332.19 18 5 1.48 664.74 652 16 1.0lE-01 32.3 l.45E+OO Flags: "T" = Tentatively associated
Interference Report Page : 4 Sample ID : 30282 Acquisition date 30-MAY-2014 12:58:58 No interference correction performed
Nuclide Line Activity Report Page : 5 Sample ID : 30282 Acquisition date 30-MAY-2014 12:58:58 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 160 10.67* 4. 211E-01 2.515E-05 2.515E-05 8.05 TL-208 72.80 ------ 2.14 l.070E+OO ------ Line Not Found ------
74.97 ------ 3.60 1.156E+OO Line Not Found ------
84.79 ------ 1. 27 l.506E+OO Line Not Found ------
252.45 ------ 0.80 1.745E+OO ------ Line Not Found ------
277.28 ------ 6.80 l.645E+OO ------ Line Not Found ------
510.61 ------ 21. 60 1.035E+OO ------ Line Not Found ------
583.02 35 86.00* 9.195E-01 3.104E-07 5.340E-07 31. 22 763.06 ------ 1. 64 7.126E-01 ------ Line Not Found ------
860.30 ------ 12.00 6.341E-01 ------ Line Not Found ------
PB-212 74.81 ------ 10.50 1.150E+OO ------ Line Not Found ------
77 .11 48 17.70 1.245E+OO 1.536E-06 1. 540E-06 38.20 87.19 ------ 6.27 1.579E+OO ------ Line Not Found ------
90.13 ------ 1. 86 1.662E+OO ------ Line Not Found ------
115. 12 ------ 0.59 2.085E+OO ------ Line Not Found ------
238.58 198 43.60* l.804E+OO 1.772E-06 1.776E-06 8.41 300.03 ------ 3.34 1.562E+OO ------ Line Not Found ------
BI-214 76. 86 48 0.58 1. 245E+OO 4.687E-05 5.107E-05 38.20 79.29 ------ 0.97 1. 320E+OO ------ Line Not Found ------
609.31 61 46.10* 8.832E-01 1.059E-06 1.154E-06 13.06 665.44 ------ 1. 56 8.131E-01 ------ Line Not Found ------
768.35 ------ 4.88 7.078E-01 ------ Line Not Found ------
806.16 ------ 1. 23 6.754E-01 ------ Line Not Found ------
934.04 ------ 3.16 5.861E-01 ------ Line Not Found ------
1120. 27 ------ 15.00 4.982E-Ol ------ Line Not Found ------
1155.18 ------ 1. 69 4.860E-01 ------ Line Not Found ------
1238 .11 ------ 5.92 4.615E-01 ------ Line Not Found ------
1280.95 ------ 1. 4 7 4.510E-01 ------ Line Not Found ------
1377. 66 ------ 4.02 4.323E-01 ------ Line Not Found ------
1385.30 ------ 0.78 4, 311E-01 ------ Line Not Found ------
1401'. 48 ------ 1. 39 4.287E-01 ------ Line Not Found ------
1407.97 ------ 2.48 4.277E-01 ------ Line Not Found ------
1509.22 ------ 2.19 4.165E-01 ------ Line Not Found ------
1583.22 ------ 0.72 4.120E-01 ------ Line Not Found ------
1661. 26 ------ 1.15 4.103E-01 ------ Line Not Found ------
1729.58 ------ 3.05 4 .114E-01 ------ Line Not Found ------
1764.49 ------ 15.90 4.128E-01 ------ Line Not Found ------
1847.41 ------ 2.12 4.187E-01 ------ Line Not Found ------
PB-214 53.17 ------ 1.10 2.929E-01 ------ Line Not Found ------
74.81 ------ 6.52 1.150E+OO ------ Line Not Found ------
77 .11 48 11. 00 1. 245E+OO 2.471E-06 2.634E-06 38.20 87.19 ------ 3.88 1.579E+OO Line Not Found ------
90.13 ------ 1.15 1.662E+OO Line Not Found -----*-
241. 92 69 7.46 1.792E+OO 3.642E-06 3.882E-06 29.36 258.94 ------ 0.55 1.718E+OO ------ Line Not Found ------
295.09 60 19.20* 1.578E+OO l.384E-06 1.475E-06 21. 36 351.87 77 37.10 1.395E+OO 1.045E-06 l .113E-06 18.42 785.83 ------ 1. 09 6.925E-01 ------ Line Not Found ------
839.00 ------ 0.59 6.497E-01 ------ Line Not Found ------
Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30282 Acquisition date 30-MAY*-2014 12:58:58 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error RA-224 83.79 ------ 0.20 1. 474E+OO ------ Line Not Found ------
240.76 69 3.90* 1.792E+OO 6.967E-06 6. 969E-06 29.36 AC-228 89. 96 ------ 3.40 1.657E+OO ------ Line Not Found ------
93.35 ------ 5.60 1.743E+OO ------ Line Not Found ------
99.55 1. 30 l.876E+OO ------ Line Not Found ------
105.36 ------ 2.00 l.973E+OO ------ Line Not Found ------
108.99 0.67 2.021E+OO ------ Line Not Found ------
129.03 2.90 2.163E+OO ------ Line Not Found ------
153.89 0.84 2.160E+OO ------ Line Not Found ------
209.39 4.10 1.937E+OO Line Not Found ------
216.24 0.80 1.905E+OO Line Not Found ------
270.26 3.80 1.673E+OO ------ Line Not Found ------
328.07 25 3.50 1. 4 67E+OO 3.403E-06 3.419E-06 32.57 338.42 43 12.40 l.434E+OO 1. 710E-06 1. 718E-06 25.36 340.94 ------ 0.52 l.428E+OO ------ Line Not Found ------
409.62 ------ 2.20 1.243E+OO ------ Line Not Found ------
463.10 ------ 4. 60 1.125E+OO ------ Line Not Found ------
562.65 ------ 1. 01 9.501E-01 ------ Line Not Found ------
581.52 ------ 3.00 9.221E-01 ------ Line Not Found ------
726.63 ------ 0.87 7.472E-01 ------ Line Not Found ------
755.28 ------ 1. 32 7.197E-01 ------ Line Not Found ------
772.28 ------ 1. 09 7.043E-01 ------ Line Not Found ------
782.12 ------ 0.59 6.956E-01 ------ Line Not Found ------
794.79 ------ 4.60 6.848E-01 ------ Line Not Found ------
830.59 ------ 0.63 6.561E-01 ------ Line Not Found ------
835.60 ------ 1. 71 6.523E-01 ------ Line Not Found ------
840.44 ------ 0.94 6.486E-01 ------ Line Not Found ------
904.29 ------ 0.89 6.044E-01 ------ Line Not Found ------
911.16 50 29.00* 6.002E-01 2.005E-06 2.014E-06 14.83 964.64 5.80 5.686E-01 ------ Line Not Found ------
968.97 26 17.40 5.664E-01 1.881E-06 1. 890E-06 28.96 1246.60 0.57 4.593E-01 ----*-- Line Not Found ------
1459.19 1. 06 4.213E-01 ------ Line Not Found ------
1496.00 1. 05 4.176E-01 ------ Line Not Found ------
1501. 44 0.58 4.172E-01 ------ Line Not Found ------
1580.30 0. 71 4.121E-01 ------ Line Not Found ------
1588.23 3. 60 4 .118E-01 ------ Line Not Found ------
1630.47 ------ 1. 95 4.106E-01 ------ Line Not Found ------
1638.10 ------ 0.54 4.105E-Ol ------ Line Not Found ------
Flag: "*" = Keyline
Minimum Detectable Activity Report Page : 7 Sample ID 30282 Acquisition date 30-MAY-2014 12:58:58 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)
BE-7 9. 477.61 1.0455E-06 MN-54 8. 834.83 1. 7105E-07 MN-56 12. 846.81 2 .1351E-07 C0-57 46. 122.06 1.3212E-07 C0-58 5. 810.79 l.4299E-07 C0-60 3. 1332.50 l.7260E-07 SB-124 0. 1690.98 9.8444E-08 SB-125 10. 427. 88 3.4734E-07 CS-134 10. 604. 71 1.4206E-07 CS-137 4. 661.66 1.2134E-07