Health Physics Sample Records Sample ID: 142467 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

1405308D 04 STARYARD SURVEY PT 38 Common Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N

Contact:

COOPER, TERRY L Survey No:

Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments:

Reviewed: DYNES, WILLIAM J Date: 06/04/14 08:10 Comments:

1*0.-igin . l Mat. SizeNolume: 2037 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00

Description:

STARYARD SURVEY PT 38 Collection Sample Tech: DYNES, WILLIAM J Sample Date: 05/30/14 08:50 Count Time: 900 (secs.)

Tritium Req: No Sample SizeNolume: 2237 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA RLSSS Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: ~

Location Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:

Stored By:, Date: 00/00/00 00:00 Sample Loe:

Other:

Material Loe:

06/18/201414:08 Page 1 of3

Health Physics Sample Records Sample ID: 142467 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140530BD 04 STARYARD SURVEY PT 38 I -

Analysis Geometry MCAID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date

~~-----

B_ 1L_ marinelli_sand_ 30361 2237GR .000 PARK, MICHAEL C 06/05/1415:33 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.00001234 1.37E-6 r 84.855% 40 0 TL-208 NT 2.384E-7 6.51E-8 r 1.639% 208 0 PB-212 NT 3.916E-7 7.75E-8 r 2.693% 212 0 Bl-214 NT 3.442E-7 9.62E-8 r 2.367% 214 0 PB-214 NT 5.876E-7 1.979E-7 r 4.041% 214 0 AC-228 NT 6.406E-7 1.547E-7 r 4.405% 228 0 BE-7 AP 7.9175E-7 w 0.000% 7 0 MN-54 AP 9.5191E-8 w 0.000% 54 0 MN-56 AP 8.8823E-8 JV 0.000% 56 0 C0-57 AP 8.9188E-8 JV 0.000% 57 0 C0-58 AP 9.2968E-8 JV 0.000% 58 0 C0-60 AP 1.0256E-7 JV 0.000% 60 0 SB-124 AP 7.1207E-8 JV 0.000% 124 0 SB-125 FP 2.3926E-7 JV 0.000% 125 0 CS-134 FP 5.6712E-8 JV 0.000% 134 0 CS-137 FP 9.6985E-8 JV 0.000% 137 1-AnalysisReview I Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/10/1413:36 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:

Comments:

06/18/2014 14:08 Page 2 of 3

Health Physics Sample Records Sample ID: 142467 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

140530BD 04 STARYARD SURVEY PT 38 I Review/Approve I HP Review Reviewed: COOPER, TERRY L Date: 06/10/1413:36 Comments:

Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:

Final Approval Approved: COOPER, TERRY L Date: 06/10/1413:36 Comments:

06/18/2014 14:08 Page 3 of 3

  • SONGS HEALTH PHYSICS REPORT 5-JUN-2014 15:30 *
  • >>>>> SAMPLE PARAMETERS<<<<< *
  • Title 140530BD 04 STARYARD SURVEY PT 38 *
  • ID 30361 Acquisition date: 5-JUN-2014 15:27:45. *
  • Start Time: 5-JUN-2014 15:27:00. *
  • Stop Time: 5-JUN-2014 15:27:00. Counting System U2GSP *
  • Quantity 2.23700E+03 GR IHPS Sample Number: 142467 *
  • Geometry B lL marinelli_sand_l Analysis Library HP NATURAL *
  • Operator: MICHAEL PARK *
  • >>>>> B #42-TP11663A PARAMETERS<<<<< *
  • Elapsed Live Time 0 00:03:00.43 Calibration 5-JUN-2014 08:35: *
  • Elapsed Real Time 0 00:03:00.48 Energy Offset -4.96372E-01 *
  • Deadtime 0.0% Energy Slope 5.00067E-01 *
  • Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1. 00000 *
  • Half Life Ratio 8.00000 Sensitivity 5.00000
  • Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1 77.21 39 17 1. 29 155.39 153 6 23.3 l.47E+OO BI-214 PB-212 PB-214 1 238.65 46 14 1. 35 478.22 475 7 19.8 1.61E+OO PB-212 1 294.89 25 15 1. 82 590.69 587 10 33.7 1.05E+OO PB-214 1 338.18 18 2 1. 38 677.27 67 4 8 27.1 3.09E-01 AC-228 1 352.21 39 5 1. 75 705.32 700 10 19.3 3.76E-01 PB-214 1 582.66 17 2 1. 80 1166.17 1162 8 27.3 2.66E-01 TL-208 1 60 9. 41 19 2 1. 95 1219.65 1214 10 28.0 1. 54E+OO BI-214 1 911. 65 17 0 2.25 1824.08 1819 11 24.1 4.12E-01 AC-228 1 1460.87 83 0 2.51 2922.43 2917 12 11.1 9.54E-01 K-40

Summary of Nuclide Activity Page : 2 Sample ID : 30361 Acquisition date 5-JUN-2014 15:27:45 Total number of lines in spectrum 9 Number of unidentified lines 0 Number of lines tentatively identified by NID 9 100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 1. 28E+09Y 1. 00 l.234E-05 1. 234E-05 0 .137E-05 11.06 A TL-208 3.05M 1. 64 1.452E-07 2.384E-07 0.651E-07 27.32 A PB-212 10.64H 1. 00 3.907E-07 3. 916E-07 0.775E-07 19.79 A BI-214 19.90M 1. 08 3.182E-07 3.442E-07 0.962E-07 27.95 A PB-214 26.80M 1. 06 5.543E-07 5.876E-07 1. 979E-07 33.68 A AC-228 6.13H 1. 00 6.379E-07 6.406E-07 1. 54 7E-07 24.14 A Total Activity 1.439E-05 l,455E-05 Grand Total Activity : l.439E-05 1. 455E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit

Unidentified Energy Lines Page : 3 Sample ID : 30361 Acquisition date 5-JUN-2014 15:27:45 None Flags: "T" Tentatively associated

Interference Report Page : 4 Sample ID : 30361 Acquisition date 5-JUN-2014 15:27:45 No interference correction performed

Nuclide Line Activity Report Page : 5 Sample ID : 30361 Acquisition date 5-JUN-2014 15:27:45 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 83 10.67* 4. 211E-01 1.234E-05 1.234E-05 11. 06 TL-208 72. 80 ------ 2.14 1.070E+OO Line Not Found ------

74.97 ------ 3.60 1.156E+OO ------ Line Not Found ------

84.79 ------ 1. 27 1.506E+OO ------ Line Not Found ------

252.45 ------ 0.80 1.745E+OO ------ Line Not Found ------

277.28 ------ 6.80 1. 645E+OO ------ Line Not Found ------

510.61 ------ 21. 60 1.035E+OO ------ Line Not Found ------

583.02 17 86.00* 9.204E-01 1.452E-07 2.384E-07 27.32 763.06 ------ 1. 64 7.126E-01 Line Not Found ------

860.30 ------ 12.00 6.341E-01 Line Not Found ------

PB-212 74.81 ------ 10.50 1.150E+OO Line Not Found ------

77 .11 39 17.70 1.243E+OO 1.194E-06 1.197E-06 23.31 87.19 ------ 6.27 1.579E+OO ------ Line Not Found ------

90 .13 ------ 1. 86 1.662E+OO ------ Line Not Found ------

115. 12 ------ 0.59 2.085E+OO ------ Line Not Found ------

238.58 46 43.60* 1. 804E+OO 3.907E-07 3.916E-07 19.79 300.03 ------ 3.34 1.562E+OO ------ Line Not Found ------

BI-214 76.86 39 0.58 1. 243E+OO 3.643E-05 3.940E-05 23.31 79.29 ------ 0.97 1.320E+OO ------ Line Not Found ------

609.31 19 46.10* 8.832E-01 3.182E-07 3.442E-07 27.95 665.44 ------ 1. 56 8.131E-01 Line Not Found ------

7 68. 35 ------ 4.88 7.078E-01 Line Not Found ------

806.16 ------ 1. 23 6.754E-01 Line Not Found ------

934.04 ------ 3.16 5.861E-01 ------ Line Not Found ------

1120. 27 ------ 15.00 4.982E-01 ------ Line Not Found ------

1155.18 ------ 1. 69 4.860E-01 ------ Line Not Found ------

1238.11 ------ 5.92 4.615E-01 ------ Line Not Found ------

1280.95 ------ 1. 4 7 4.510E-01 ------ Line Not Found ------

1377.66 ------ 4.02 4.323E-01 ------ Line Not Found ------

1385.30 ------ 0.78 4. 311E-01 ------ Line Not Found ------

1401.48 ------ 1. 39 4.287E-01 ------ Line Not Found ------

1407.97 ------ 2.48 4.277E-01 Line Not Found ------

1509.22 ------ 2.19 4.165E-01 Line Not Found ------

1583.22 ------ 0. 72 4.120E-01 Line Not Found ------

1661.26 ------ 1.15 4.103E-01 ------ Line Not Found ------

1729.58 ------ 3.05 4 .114E-01 ------ Line Not Found ------

1764.49 ------ 15.90 4.128E-01 ------ Line Not Found -----*-

1847.41 ------ 2.12 4.187E-01 ------ Line Not Found ------

PB-214 53.17 ------ 1.10 2.929E-01 ------ Line Not Found ------

74.81 ------ 6.52 1.150E+OO ------ Line Not Found ------

77.11 39 11. 00 1. 243E+OO 1. 921E-06 2.036E-06 23.31 87.19 ------ 3.88 1.579E+OO ------ Line Not Found ------

90.13 ------ 1.15 1.662E+OO ------ Line Not Found ------

241.92 ------ 7.46 1. 790E+OO ------ Line Not Found -------

258.94 ------ 0.55 1. 718E+OO ------ Line Not Found ------

295.09 25 19.20* 1.580E+OO 5.543E-07 5.876E-07 33.68 351. 87 39 37.10 1.394E+OO 5.054E-07 5.358E-07 19.25 785.83 ------ 1. 09 6.925E-01 ------ Line Not Found ------

839.00 ------ 0.59 6.497E-01 ------ Line Not Found ------

Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30361 Acquisition date 5-JUN-2014 15:27:45 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error AC-228 89. 96 ------ 3.40 l.657E+OO ------ Line Not Found ------

93.35 ------ 5.60 1.743E+OO ------ Line Not Found ------

99.55 ------ 1. 30 l.876E+OO ------ Line Not Found ------

105.36 ------ 2.00 l.973E+OO ------ Line Not Found ------

108.99 ------ 0.67 2.021E+OO ------ Line Not Found ------

12 9. 03 ------ 2.90 2.163E+OO ------ Line Not Found ------

153.89 ------ 0.84 2.160E+OO ------ Line Not Found ------

209.39 ------ 4.10 l.937E+OO ------ Line Not Found ------

216.24 ------ 0.80 1.905E+OO ------ Line Not Found ------

270.26 ------ 3.80 1.673E+OO ------ Line Not Found ------

328.07 ------ 3.50 1.468E+OO ------ Line Not Found ------

338.42 18 12.40 l.436E+OO 6.943E-07 6. 972E-07 27.08 340.94 ------ 0.52 1.428E+OO ------ Line Not Found ------

409.62 ------ 2.20 1.243E+OO ------ Line Not Found ------

463.10 ------ 4.60 1.125E+OO ------ Line Not Found ------

562.65 ------ 1. 01 9.501E-01 ------ Line Not Found ------

581.52 ------ 3.00 9.221E-01 ------ Line Not Found ------

726.63 ------ 0.87 7.472E-01 ------ Line Not Found ------

755.28 ------ 1. 32 7.197E-01 ------ Line Not Found ------

772. 28 ------ 1. 09 7.043E-01 ------ Line Not Found ------

782.12 ------ 0.59 6.956E-01 ------ Line Not Found ------

794.79 ------ 4. 60 6.848E-01 ------ Line Not Found ------

830.59 ------ 0.63 6.561E-01 ------ Line Not Found ------

835.60 ------ 1. 71 6.523E-01 ------ Line Not Found ------

840.44 ------ 0.94 6. 486E-01 ------ Line Not Found ------

904.29 ------ 0.89 6.044E-01 ------ Line Not Found ------

911.16 17 29.00* 5.998E-01 6.379E-07 6.406E-07 24.14 964.64 ------ 5.80 5.686E-01 ------ Line Not Found ------

968.97 ------ 17.40 5.663E-01 ------ Line Not Found ------

1246.60 ------ 0.57 4.593E-01 ------ Line Not Found ------

1459.19 ------ 1. 06 4.213E-01 ------ Line Not Found ------

1496.00 ------ 1. 05 4.176E-01 ------ Line Not Found ------

1501. 44 ------ 0.58 4 .172E-01 ------ Line Not Found ------

1580.30 ------ 0. 71 4.121E-01 ------ Line Not Found ------

1588.23 ------ 3.60 4 .118E-01 ------ Line Not Found ------

1630.47 ------ 1. 95 4.106E-01 ------ Line Not Found ------

1638.10 ------ 0.54 4.105E-01 ------ Line Not Found ------

Flag: "*" = Keyline

Minimum Detectable Activity Report Page : 7 Sample ID 30361 Acquisition date 5-JUN-2014 15:27:45 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)

BE-7 5. 477.61 7.9175E-07 MN-54 2. 834.83 9.5191E-08 MN-56 1. 846.81 8.8823E-08 C0-57 22. 122.06 8. 9188E-08 C0-58 2. 810.79 9.2968E-08 C0-60 1. 1332.50 1.0256E-07 SB-124 2. 602.73 7.1207E-08 SB-125 0. 635.89 2.3926E-07 CS-134 1. 604.71 5.6712E-08 CS-137 3. 661.66 9.6985E-08