Health Physics Sample Records Sample ID: 142449 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140528BD 19 STAR 19-20 Dirt Sample
[Common-[
Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N
Contact:
COOPER, TERRY L Survey No:
Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 05/30/14 09:01 Comments:
Origin -I Mat. SizeNolume: 2221 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
STAR 19 SOIL SAMPLE I Collection Sample Tech: DYNES, WILLIAM J Sample Date: 05/29/14 08:15 Count Time: 900 (secs.)
Tritium Req: No Sample SizeNolume: 2221 GRAMS Instructions:
Comments: COUNT TO MDA I RLsss I Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: ~
[Location[
Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: 3" (in.) Equip ID:
Stored By:, Date: 00/00/00 00:00 Sample Loe:
Other:
Material Loe:
06/18/201411:55 Page 1 of 3
Health Physics Sample Records Sample ID: 142449 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140528BD 19 STAR 19-20 Dirt Sample
!Analysis I Geometry MCAID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date C_ 1 L_marinelli_sand_ 30297 2221 GR .000 PARK, MICHAEL C 06/02/14 09:58 Isotope Mode Activity Activity Uncert. LLD/MDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 0.000011311.16E-6 r 69.696% 40 0 TL-208 NT 2.656E-7 7.26E-8 r 1.637% 208 0 PB-212 NT 8.025E-7 9.01E-8 r 4.945% 212 0 Bl-214 NT 2.14E-7 1.031E-7 r 1.319% 214 0 PB-214 NT 7.054E-7 2.321E-7 r 4.347% 214 0 RA-224 NT 2.036E-6 8.1E-7 r 12.546% 224 0 AC-228 NT 8.942E-7 1.68E-7 r 5.510% 228 0 BE-7 AP 6.2356E-7 Iv" 0.000% 7 0 MN-54 AP 9.9459E-8 W' 0.000% 54 0 MN-56 AP 9.487E-8 w 0.000% 56 0 C0-57 AP 8.1745E-8 ~ 0.000% 57 0
0 C0-58 C0-60 AP AP 9.1172E-8 8.4669E-8 "'"' 0.000%
0.000%
58 60 0 SB-124 AP 6.6535E-8 ~ 0.000% 124 0 SB-125 FP 2.4056E-7 Iv' 0.000% 125 0 CS-134 FP 6.2965E-8 ~ 0.000% 134 0 CS-137 FP 1.0084E-7 ~ 0.000% 137 Analysis Review Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/10/1410:21 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments:
06/18/201411:55 Page2 of 3
Health Physics Sample Records Sample ID: 142449 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140528BD 19 STAR 19-20 Dirt Sample Review/Approve I HP En_g_ Review Reviewed: COOPER, TERRY L Date: 06/10/14 10:21 Comments:
Disposition Disposition: OTHER Result Sample contains only natural isotopes Remarks:
Final Approval Approved: COOPER, TERRY L Date: 06/10/14 10:21 Comments:
06/18/201411:55 Page 3 of 3
- SONGS HEALTH PHYSICS REPORT 2-JUN-20:4 09:55 *
- >>>>> SAMPLE PARAMETERS<<<<< *
- Title 140528BD 19 STAR 19-20 DIRT SAMPLE *
- .ID 30297 Acquisition date: 2-JUN-2014 09:52:37. *
- Start Time: 2-JUN-2014 09:52:00. *
- Stop Time: 2-JUN-2014 09:52:00. Counting System U2GSP *
- Quantity 2.22100E+03 GR IHPS Sample Number: 142449 *
- Geometry C lL marinelli_sand_l Analysis Library HP NATURAL *
- Operator: MICHAEL PARK *
- >>>>> C #41-TP11750A PARAMETERS<<<<< *
- Elapsed Live Time 0 00:03:00.38 Calibration 1-JUN-2014 20:29: *
- Elapsed Real Time 0 00:03:00.45 Energy Offset -1.46898E-01 *
- Deadtime 0.0% Energy Slope 4.99817E-01 *
- Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1. 00000 *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 77.24 35 63 0.99 154.82 152 8 43.2 2.39E+OO BI-214 PB-212 PB-214 3 238.58 106 14 1. 08 477.61 471 18 11. 2 1.99E+OO PB-212 3 241.60 24 7 l. 50 483.66 471 18 39.8 RA-224 PB-214 1 295.23 35 22 1. 73 590.94 586 12 32.9 1.67E+OO PB-214 1 338.37 27 *4 1. 62 677.26 673 8 22.3 2.93E-01 AC-228 1 351.83 38 18 1. 30 704.17 700 10 26.6 1.59E+OO PB-214 1 583.25 25 5 1. 04 1167.11 1163 10 27.3 6.31E-01 TL-208 1 609.13 15 14 1. 74 1218.89 1215 8 48.2 1. 30E+OO BI-214 1 911. 06 29 0 1. 86 1822.83 1818 9 18.8 8.17E-01 AC-228 1 968. 83 23 3 2. 62 1938.38 1933 11 24.1 7.56E-01 AC-228 1 1460.57 99 0 1. 93 2921.86 2916 11 10.3 1.81E+OO K-40
Summary of Nuclide Activity Page : 2 Sample ID : 30297 Acquisition date 2-JUN-2014 09:52:37 Total number of lines in spectrum 11 Number of unidentified lines 0 Number of lines tentatively identified by NID 11 100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 1.28E+09Y 1. 00 1.131E-05 l.131E-05 0 .116E-05 10.25 A TL-208 3.05M 1. 59 1.673E-07 2.656E-07 0. 726E-07 27.33 A PB-212 10.64H 1. 00 8.006E-07 8.025E-07 0.901E-07 11. 22 A BI-214 19.90M 1. 08 1.989E-07 2.140E-07 1.031E-07 48.17 A PB-214 26. SOM 1. 06 6.679E-07 7.054E-07 2.321E-07 32.90 A RA-224 3.66D 1. 00 2.036E-06 2.036E-06 O.SlOE-06 39.75 A AC-228 6.13H 1. 00 8.906E-07 8.942E-07 l.680E-07 18.79 A Total Activity 1.607E-05 1.623E-05 Grand Total Activity : 1.607E-05 1. 623E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit
Unidentified Energy Lines Page : 3 Sample ID : 30297 Acquisition date 2-JUN-2014 09:52:37 None Flags: "T" Tentatively associated
Interference Report Page : 4 Sample ID : 30297 Acquisition date 2-JUN-2014 09:52:37 No interference correction performed
Nuclide Line Activity Report Page : 5 Sample ID : 30297 Acquisition date 2-JUN-2014 09:52:37 Nuclide Type: nalural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 99 10.67* 5.560E-01 1.131E-05 1.131E-05 10.25 TL-208 72. 80 ------ 2.14 1.486E+OO ------ Line Not Found ------
74.97 ------ 3.60 l.577E+OO ------ Line Not Found ------
84.79 ------ 1. 27 1.917E+OO ------ Line Not Found ------
252.45 ------ 0.80 2.004E+OO ------ Line Not Found ------
277.28 ------ 6.80 1.917E+OO ------ Line Not Found ------
510.61 ------ 21. 60 1.298E+OO ------ Line Not Found ------
583.02 25 86.00* 1.157E+OO l.673E-07 2.656E-07 27.33 763.06 ------ 1. 64 8.934E-01 ------ Line Not Found ------
860.30 ------ 12.00 7.922E-01 ------ Line Not Found ------
PB-212 74.81 ------ 10.50 1. 570E+OO ------ Line Not Found ------
77 .11 35 17.70 1.666E+OO 7.949E-07 7. 968E-07 43.18 87.19 ------ 6.27 1. 983E+OO ------ Line Not Found ------
90.13 ------ 1. 86 2.055E+OO ------ Line Not Found ------
115. 12 ------ 0.59 2.376E+OO ------ Line Not Found ------
238.58 106 43.60* 2.055E+OO 8.006E-07 8.025E-07 11.22 300.03 ------ 3.34 1.843E+OO ------ Line Not Found ------
BI-214 76.86 35 0.58 1. 666E+OO 2.426E-05 2. 611E-05 43.18 79.29 ------ 0.97 1.741E+OO ------ Line Not Found ------
609.31 15 46.10* 1. 112E+OO l.989E-07 2.140E-07 48.17 665.44 ------ 1. 56 1.023E+OO ------ Line Not Found ------
7 68. 35 ------ 4.88 8.873E-01 ------ Line Not Found ------
806.16 ------ 1. 23 8.454E-01 ------ Line Not Found ------
934.04 ------ 3.16 7.310E-01 ------ Line Not Found ------
1120. 27 ------ 15.00 6.242E-01 ------ Line Not Found ------
1155.18 ------ 1. 69 6.105E-01 ------ Line Not Found ------
1238.11 ------ 5.92 5.846E-Ol ------ Line Not Found ------
1280.95 ------ 1. 4 7 5.747E-01 ------ Line Not Found ------
1377.66 ------ 4.02 5.602E-01 ------ Line Not Found ------
1385. 30 ------ 0.78 5.595E-01 ------ Line Not Found ------
1401. 48 ------ 1. 39 5.583E-01 ------ Line Not Found ------
1407.97 ------ 2.48 5.578E-01 ------ Line Not Found ------
1509.22 ------ 2.19 5.568E-01 ------ Line Not Found ------
1583.22 ------ 0.72 5.628E-01 ------ Line Not Found ------
1661. 26 ------ 1.15 5.753E-01 ------ Line Not Found ------
1729.58 ------ 3.05 5.918E-01 ------ Line Not Found ------
1764.49 ------ 15.90 6.023E-01 ------ Line Not Found ------
1847.41 ------ 2.12 6.331E-01 ------ Line Not Found ------
PB-214 53.17 ------ 1.10 5.203E-01 ------ Line Not Found ------
74.81 ------ 6.52 1.570E+OO ------ Line Not Found ------
77 .11 35 11. 00 l.666E+OO 1.279E-06 1.351E-06 43.18 87.19 ------ 3.88 1.983E+OO Line Not Found ------
90.13 ------ 1.15 2.055E+OO ------ Line Not Found ------
241. 92 24 7.46 2.044E+OO 1. 064E-06 1.124E-06 39.75 258.94 ------ 0.55 1.981E+OO ------ Line Not Found ------
295.09 35 19.20* 1.858E+OO 6.679E-07 7.054E-07 32.90 351. 87 38 37.10 1. 686E+OO 4.124E-07 4.356E-07 26.63 785.83 ------ 1. 09 8.674E-01 ------ Line Not Found ------
839.00 ------ 0.59 8.122E-01 ------ Line Not Found ------
Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30297 Acquisition date 2-JUN-2014 09:52:37 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error RA-224 83.79 ------ 0.20 l.887E+OO Line Not Found ------
240.76 24 3.90* 2.044E+OO 2.036E-06 2.036E-06 39.75 AC-228 89. 96 ------ 3.40 2.051E+OO Line Not Found ------
93.35 ------ 5.60 2.124E+OO Line Not Found ------
99.55 ------ 1. 30 2.229E+OO Line Not Found ------
105.36 ------ 2.00 2.301E+OO Line Not Found ------
108.99 ------ 0.67 2.335E+OO Line Not Found ------
129.03 ------ 2.90 2.414E+OO Line Not Found ------
153.89 ------ 0.84 2.377E+OO Line Not Found ------
209.39 ------ 4.10 2.168E+OO ------ Line Not Found ------
216.24 ------ 0.80 2.141E+OO ------ Line Not Found -------
270.26 ------ 3.80 1.941E+OO ------ Line Not Found ------
328.07 ------ 3.50 1.756E+OO ------ Line Not Found ------
338.42 27 12.40 1. 725E+OO 8.486E-07 8.520E-07 22.30 340.94 ------ 0.52 1. 718E+OO Line Not Found ------
409.62 ------ 2.20 l.531E+OO Line Not Found ------
463.10 ------ 4.60 1. 401E+OO Line Not Found ------
562.65 ------ 1. 01 l.195E+OO Line Not Found ------
581.52 ------ 3.00 1.160E+OO Line Not Found ------
72 6. 63 ------ 0.87 9.382E-01 Line Not Found ------
755.28 ------ 1. 32 9.027E-01 Line Not Found ------
772.28 ------ 1. 09 8.827E-01 Line Not Found ------
782.12 ------ 0.59 8. 716E-01 Line Not Found ------
794.79 ------ 4. 60 8.576E-Ol Line Not Found ------
830.59 ------ 0.63 8.205E-01 Line Not Found ------
835.60 ------ 1. 71 8.155E-01 Line Not Found ------
840.44 ------ 0.94 8.l08E-01 Line Not Found ------
904.29 ------ 0.89 7.542E-01 Line Not Found ------
911.16 29 29.00* 7.488E-01 8.906E-07 8.942E-07 18.79 964. 64 ------ 5.80 7.091E-01 ------ Line Not Found ------
968. 97 23 17.40 7.062E-01 l.282E-06 l.288E-06 24.05 1246.60 ------ 0.57 5.825E-01 ------ Line Not Found ------
1459.19 ------ 1. 06 5.560E-Ol ------ Line Not Found ------
1496.00 ------ 1. 05 5.563E-01 -----*- Line Not Found ------
1501. 44 ------ 0.58 5.565E-01 ------ Line Not Found ------
1580.30 ------ 0. 71 5.624E-01 Line Not Found ------
1588.23 ------ 3.60 5.634E-Ol Line Not Found ------
1630.47 ------ 1. 95 5.696E-01 Line Not Found ------
1638.10 ------ 0.54 5.709E-01 Line Not Found ------
Flag: "*" = Keyline
Minimum Detectable Activity Report Page : 7 Sample ID 30297 Acquisition date 2-JON-2014 09:52:37 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)
BE-7 5. 477.61 6.2356E-07 MN-54 4. 834.83 9.9459E-08 MN-56 3. 846.81 9.4870E-08 C0-57 23. 122.06 8.1745E-08 C0-58 3. 810.79 9. 11 72E-08 C0-60 1. 1173.24 8.4669E-08 SB-124 0. 1690.98 6.6535E-08 SB-125 8. 427.88 2.4056E-07 CS-134 3. 604. 71 6.2965E-08 CS-137 5. 661. 66 l.0084E-07