Sample ID:

142446 Type: RLSSS Type Detail: SAND

==

Description:==

1405288D 16 STAR 16-20 Dirt Sample Common Resp Org: P4000 - PROJECT MANAGEMEt

Contact:

COOPER, TERRY L Reference ID:

Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:

LQ[~gll!J Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 05/30/14 08:44 Mat. SizeNolume:

1982 GRAMS Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00

==

Description:==

STAR 16 SOIL SAMPLE I Col~£tion I Sample Tech:

DYNES, WILLIAM J Tritium Req:

No Instructions:

Comments:

COUNT TO MDA I RLSSS I Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes Location Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Other: COUNT TO MDA Material Loe:

06/18/201411:54 Sample Date: 05/29/14 07:46 Sample SizeNolume: 1982 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

[v' Elev: 100 Room:

Depth: 3" (in.)

Equip ID:

Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Sample ID:

142446 Type: RLSSS Type Detail: SAND

==

Description:==

1405288D 16 STAR 16-20 Dirt Sample IAna1ysisl

~eometry'~---

A_1 L_marinelli_sand_

MCA ID Quant.

Units 30295 1982GR Method Isotope Mode Activity Activity Uncert.

LLD/MDA 0

K-40 NT 0.00001337 1.36E-6 0

TL-208 NT 2.885E-7 7.16E-8 0

PB-212 NT 5.155E-7 1.088E-7 0

81-214 NT 5.936E-7 1.028E-7 r

0 PB-214 NT 4.873E-7 1.036E-7 r

0 BE-7 AP 8.087E-7 w

0 MN-54 AP 1.1389E-7

~

0 MN-56 AP 1.2827E-7

~

0 C0-57 AP 7.067E-8

~

0 C0-58 AP 6.7497E-8 w

0 C0-60 AP 1.0153E-7 w

0 SB-124 AP 7.8882E-8 w

0 SB-125 FP 2.5157E-7 w

0 CS-134 FP 6.5141E-8

~

0 CS-137 FP 8.1994E-8

~

~alysis Review I Health Physics Sample Records Status: APPROVED FP/AP Lab Analysis~y

.000 PARK, MICHAEL C

%Abund.

Atom. No.

Comments 87.644%

40 1.891%

208 3.379%

212 3.891%

214 3.194%

214 0.000%

7 0.000%

54 0.000%

56 0.000%

57 0.000%

58 0.000%

60 0.000%

124 0.000%

125 0.000%

134 0.000%

137 Re-Analize:

No Lie Rad Mat Present:

No Reviewed: COOPER, TERRY L HP Notified Name:

Hp Eng Rvw Reqd:

Yes Comments:

06/18/201411:54 Rad Mat Present:

Yes Rasterized: r Date Mod ID Mod Date 06/02/14 09:58 Mod Id Mod Date Date: 06/10/1410:07 Page 2 of 3

Sample ID:

142446 Type: RLSSS Type Detail: SAND

==

Description:==

140528BD 16 STAR 16-20 Dirt Sample Review/Approve Reviewed: COOPER, TERRY L Comments: 338 keV peak is due to Ac-228 Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/18/2014 11 :54 Health Physics Sample Records Status: APPROVED Rasterized: r HP Eng Review Date: 06/10/14 10:07 Disposition Result: Sample contains only natural isotopes Final Aee_roval Date: 06/10/1410:07 Page 3 of 3

SONGS HEALTH PHYSICS REPORT 2-JUN-2014 09:54

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140528BD 16 STAR 16-20 DIRT SAMPLE

  • k
  • ID 30295 Acquisition date: 2-JUN-2014 09:50:56. *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 2-JUN-2014 09:50:00.

2-JUN-2014 09:50:00.

Counting System l.98200E+03 GR IHPS Sample Number:

A 11 marinelli_sand_l Analysis Library Operator: MICHAEL PARK U2GSP 142446 HP NATURAL

>>>>> A #41-TP11679B PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.40 0 00:03:00.46 0.0%

1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 1-JUN-2014 20:24:

2.86241E-01 4.99400E-01

1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1

238.41 62 29

1. 32 476.82 471 10 21.1 2.28E+OO PB-212 1

277.47 17 3

1. 81 555.03 552 7 27.8 5.26E-01 TL-208 1

338.34 23 0

2.33 676.92 673 9 19.9 6.98E-01 1

351.84 37 8

1. 32 703.93 700 8 21. 3 2.25E+OO PB-214 1

583.09 22 2

1. 75 1166.97 1163 8 24.8 2.00E+OO TL-208 1

609.20 36 0

1. 98 1219.26 1214 11 17.3 9. llE-01 BI-214 1

1460.60 100 0

1. 79 2923.96 2918 12 10.2 6.85E-01 K-40

Suiill1lary of Nuclide Activity Sample ID : 30295 Total number of lines in spectrum Number of unidentified lines Acquisition date Page :

2 2-JUN-2014 09:50:56 Number of lines tentatively identified by NID 7

0 7

100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 l.28E+09Y

1. 00 1.337E-05 l.337E-05 0.136E-05 10.17 A

TL-208 3.05M

1. 71 1.691E-07 2.885E-07 0.716E-07 24.81 A

PB-212 10.64H

1. 00 5.142E-07 5.155E-07 1.088E-07 21.11 A

BI-214 19.90M

1. 09 5.455E-07 5.936E-07 l.028E-07 17.31 A

PB-214 26.80M

1. 06 4.576E-07 4.873E-07 l.036E-07
21. 26 KA Total Activity 1.SOSE-05 1.525E-05 Grand Total Activity :

1.SOSE-05 l.525E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30295 Page :

3 Acquisition date : 2-JUN-2014 09:50:56 It 1

Energy 338.34 Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err

%Eff Flags 23 0

2.33 676.92 673 9 l.27E-01 19.9 l.70E+OO T

Flags: "T" = Tentatively associated

Interference Report Sample ID : 30295 No interference correction performed Acquisition date Page :

4 2-JUN-2014 09:50:56

Nuclide Line Activity Report Page :

5 Sample ID : 30295 Acquisition date 2-JUN-2014 09:50:56 Nuclide Type: nalural Uncorrected Decay Corr 1-Sigrna Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 100 10.67*

5.314E-01 l.337E-05 l.337E-05 10.17 TL-208

72. 80 2.14 1.594E+OO Line Not Found ------

74.97 3.60 l.692E+OO Line Not Found ------

84.79 ------

1. 27 2.058E+OO Line Not Found ------

252.45 ------

0.80 2.021E+OO Line Not Found ------

277.28 17 6.80 1.919E+OO 9.804E-07 l.673E-06 27.79 510.61 ------

21. 60 1.265E+OO Line Not Found ------

583.02 22 86.00*

1.128E+OO

1. 691E-07 2.885E-07 24.81 763.06 ------
1. 64 8.744E-01 ------

Line Not Found ------

860.30 12.00 7.770E-01 ------

Line Not Found ------

PB-212 74.81 ------

10.50 l.685E+OO Line Not Found ------

77.11 17.70 1.782E+OO Line Not Found ------

87.19 ------

6.27 2.129E+OO Line Not Found ------

90.13 ------

1. 86 2.206E+OO Line Not Found ------

115.12 ------

0.59 2.535E+OO Line Not Found ------

238.58 62 43.60*

2.083E+OO 5.142E-07 5.155E-07 21.11 300.03 ------

3.34 1.834E+OO Line Not Found ------

BI-214 76.86 ------

0.58 1.772E+OO Line Not Found ------

79.29 ------

0.97 l.869E+OO Line Not Found ------

609.31 36 46.10*

1.084E+OO 5.455E-07 5.936E-07 17.31 665.44

1. 56 9.985E-01 ------

Line Not Found ------

768.35 ------

4.88 8.685E-01 ------

Line Not Found ------

806.16 ------

1. 23 8.283E-01 ------

Line Not Found ------

934.04 3.16 7.177E-01 ------

Line Not Found ------

1120. 27 15.00 6.114E-01 ------

Line Not Found 1155. 18

1. 69 5.973E-01 ------

Line Not Found ------

1238.11 ------

5.92 5.697E-01 ------

Line Not Found ------

1280.95 ------

1. 4 7 5.585E-01 ------

Line Not Found ------

1377. 66 4.02 5.401E-01 ------

Line Not Found ------

1385. 30 0.78 5.391E-01 ------

Line Not Found ------

1401.48 ------

1. 39 5.370E-01 ------

Line Not Found ------

1407.97 ------

2.48 5.362E-01 ------

Line Not Found ------

1509.22 2.19 5.292E-01 ------

Line Not Found ------

1583.22 ------

0. 72 5.296E-01 ------

Line Not Found ------

1661.26 ------

1.15 5.351E-01 ------

Line Not Found ------

1729.58 ------

3.05 5.442E-01 ------

Line Not Found ------

1764.49 ------

15.90 5.503E-01 ------

Line Not Found ------

1847.41 ------

2.12 5.694E-Ol ------

Line Not Found ------

PB-214 53.17 ------

1.10 5.543E-01 ------

Line Not Found ------

74.81 ------

6.52 l.685E+OO Line Not Found ------

77.11 ------

11. 00 1.782E+OO Line Not Found ------

87.19 ------

3.88 2.129E+OO Line Not Found ------

90.13 ------

1.15 2.206E+OO Line Not Found ------

241. 92 7.46 2.067E+OO Line Not Found ------

258.94 0.55 l.994E+OO Line Not Found ------

295.09 ------

19.20*

1.852E+OO Line Not Found ------

351. 87 37 37.10 l.662E+OO 4.576E-07 4.873E-07

21. 26 785.83 ------
1. 09 8.495E-01 Line Not Found ------

839.00 ------

0.59

7. 964E-01 Line Not Fou!ld ------

Nuclide Line Activity Report (continued)

Sample ID : 30295 Acquisition date Flag: "*"

Keyline Page :

6 2-JUN-2014 09:50:56

Minimum Detectable Activity Report Page :

7 Sample ID 30295 Acquisition date 2-JUN-2014 09:50:56 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

7.

477.61 8.0870E-07 MN-54

4.

834.83 l.1389E-07 MN-56

5.

846.81 l.2827E-07 C0-57

15.

122.06 7.0670E-08 C0-58

1.

810.79 6.7497E-08 C0-60

1.

1332.50 1.0153E-07 SB-124

3.

602.73 7.8882E-08 SB-125

6.

427.88 2.5157E-07 CS-134

2.

604. 71 6.5141E-08 CS-137

2.

661.66 B.1994E-08