LER 81-030/03L-0:on 810630,all Emergency Condenser Vent Monitors Exceeded Upscale Trip Setpoint During Calibr. Caused by Difference in Response Between Test Signal & Actual Signal.Procedure Revised
ML20009H617
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 07/30/1981
From: Neild R
NIAGARA MOHAWK POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20009H612 List:
References
LER-81-030-03L, LER-81-30-3L, NUDOCS 8108100297
Download: ML20009H617 (2)


Text

-

NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION

(? ?ll '

LICENSEE EVENT REPORT CONTROL 6 LOCK: C,i l l l lh (PLEASE *"11NT OR TYPE ALL REQUIRED INFORMATION) 1 o lTIll lN l Yl N lM l P l 1 j@! ') l0l-l0l0l0l0l-l0l0l 8 3 14 15 LICENSE NUM8ER j@l4l1l1l1l1l@l 25 26 LICENSE TYPE JO l

57 GAT 58 lg 7 UCENSEE CODE CON'T lolil 3o ,$ ! L l@l 0 ] 5 l 0 l 0 l 0 l 2 l 2 l 0 @l 0 ] 6 [ 3 l 0 l 8 l 1 @l 0 l 7 l 3 l 0] 8 l 180l@

I 8 60 61 DOCKET NUMBER 68 69 EVENT O ATE le 75 REPORT DATE EVENT DESCRIPTION AND PROB ABLE CONSEQUENCES Oto lo l2l l During a refueling outage, while performed routine calibration of the Emergency  ;

ioi3i l Condenser Vent Monitors, Procedure N1-RTP-20, all four monitors exceeded the  ;

[o l4 l l upscale trip set point of 15 mr/hr. Three of the monitors (#111, 112, 121) were l io isj l >25 mr/hr but were within the allowable tolerance setting by Technical Specification; Ioisl l 3. ) . .C . One monitor (#122) trippm1 at 200 mr/hr which is out of specs and over the l l o l 71 l tolerance level. The consequences of the affected equipment were minimal since [

t o is l I the plant was in refuel mode at the time. I 80 7 8 9 DE CODE SUSC E COMPONENT CODE SUSCOD'E S E

[o_19_j l T l Bj @ W@ l E l@ l I l N l S l T l R l U l@ gj@ ] @ 20 1 9 9 10 11 12 13 18 43

_. SEQUENTIAL OCCURRENCE REPORT REV.SION EVENT YE AR R EPORT NO. COOF TYPE N O.

LER

@yug/R0 l8 l1 l RE

_.21 22 l-l 23 l0l3l0l 24 26 l/l 27 l0l3l 28 29 lL l 30 W31 l 0l 32 K N 'AC O ON PL NT ME HOURS SS 1 FOR 8. SUPPL E MANUFAC RER Q_j@l 33 34 cl@ W@ lZl@

35 36 l0l0l010l Ji 40 W@ l N lg l Llg 41 42 43 l Gl 0l 8l 0lg 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h liloll There was a difference found in the response between the test signal and the j ml actual signal. Prevfous tests were run with a simulated test signal, the test is  ;

iii2i l now run with an APJ1 calibration device using Cobalt 60 as the source. The procedure j iiial l has been revised to confirm the trip setting by response to the source. All four l ii14i I monitors were recalibrated, using the actual source, to 20 mr/hr high trip point. l 7 8 9 80 ST  % POWER OTHER STATUS DIS O RY OISCOt MY DESCRIPTION I1 isl W @ l0l0l0l@l NA l l B l@l Surveillance Tusting l ACTIVITY CO TENT RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE I i l 6 I W @D OF RELEASE l 2 l@l NA L I' NA l PERSONNEL EXPOS ES NuuSER TvPE oeSCRi,riON @

NA l l i I 71 10 l <>l Ol@l zl@l 8

,ERSO~~ELImuns

NUveER DESCRIPTION NA l li 18110l 7 8 3 01 ol@l12 11 80 TYPE DESCR PT ON NA l 1iTR8 9E_l@l

? to 30 ISSUE DE CRIPTION l2lol l NA l ((]llllllllllj

' ~ * 'a 68 69 80

  • J 8108100297 810730 Richard C. Neild PHONE:

(315)343-2110 Ext. 1528 o$

l PDR ADOCK 05000220 2ARER S

-- - - - - PDR .. _. _ - .. ,_ ._

ATTACINENT TO LER 81-30 Cause Description and Corrective Actions (continued)

The discrepancy between the test signal and the actual signal is still under investigation.