ML17317B242

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 79-03.No Type 304 Stainless Steel Piping Mfg by Youngstown Welding & Engineering Co Is in Use or Planned for Use in Facility Safety Sys
ML17317B242
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 04/17/1979
From: Dolan J
AMERICAN ELECTRIC POWER CO., INC.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
AEP-NRC-00165, AEP-NRC-165, IEB-79-03, IEB-79-3, NUDOCS 7906040049
Download: ML17317B242 (2)


Text

AMERICAN ELECTRIC POWER Ser~.i ce Corporation AEP ')rnnifu ny..h'r>r )ork..h,

('>I'~l 4'< 4800

); JODO.i JOHN E, DOLOR ilor Ci'Lair+ aa Eagiaoniag act Coro(raotioa April 17, 1979 AEP:NRC:00165 Donald C. Cook Nuclear Plant Units 1 8 2 Docket Nos. 50-315 8 50-316 License Nos. DPR-58 8 DPR-74 Response to IE Bulletin 79-05 Mr. J. G. Keppler, Regional Director U.S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region III 799 Roosevelt Road Glen Ellyn, IL 60137

Dear Mr. Keppler:

The following is in response to your letter of March 12, 1979 and to its enclosure, I.E. Bulletin No. 79-03, as it applies to the Donald C, Cook Nuclear Plant Units 1 and 2 at Bridgman, Michigan.

A thorough review was made of documentation of those safety-related systems where the use of ASTM A312 pipe (seam welded without filler metal) was permitted in our pipe specificatio'n as an alternate to ASTM A312 seamless material.

No ASME SA-312 (in our case ASTM A312), Type 304 or other seam welded (without filler metal) pipe manufactured by Youngstown Melding and Engineering Company is in use or is planned for use in the safety-related systems of the Donald C. Cook Nuclear Plant, Very truly yours, JED:em ohn E. Dolan cc: (Attached)

I-; 23 ]g7g

'r eneoa n o qq

April 17, 1979 Nr. J. G. Keppler, Regional Director AEP:NRC:00165 cc: Harold D. Thornburg-NRC RE C. Callen G. Charnoff P. W. Steketee R. J. Vollen R. Walsh D. V. Shaller-Bridgman R. W. Jurgensen