ACCELERATED D UTION DEMONSTR TION SYSIHVI REGULATORY INFORMATXON DISTRXBUTION SYSTEM (RXDS)

ACCESSION NBR:9003120358 DOC.DATE: 90/02/28 NOTARXZED: NO DOCKET FACIL:50-316 Donald C.

Cook Nuclear Power Plant, Unit 2, Indiana 6

05000316 AUTH.NAME AUTHOR AFFXLIATION ALEXICH,M.P.

Indiana Michigan Power Co.

(formerly Indiana 6 Michigan Ele RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards response to NRC Info Notice 89-56 re questionable certification of matl supplied to DOD by nuclear suppliers.

DISTRXBUTXON CODE:

A001D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: OR Submittal:

General Distribution NOTES:

RECIPIENT XD CODE/NAME PD3-1 LA GXITTER,J.

INTERNAL: NRR/DET/ECMB 9H NRR/DST 8E2 NRR/DST/SICB 7E NUDOCS-ABSTRACT OGC/HDS1 RES/DSXR/EIB EXTERNAL: LPDR NSXC COPIES LTTR ENCL 1

1 5

5 1

1 1

1 1

1 1

1 1

0 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD3-1 PD NRR/DOEA/OTS B1 1 NRR/DST/SELB 8D NRR/DST/SRXB 8E OC LFMB EG FIL 01 NRC PDR

COPIES, LTTR ENCL 1'

1 1

1 1

1 1

1 0

1 1

1 1

NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP. US TO REDUCE WASTEl CONTACTTHE.DOCUMENT CONTROL DESK, ROOM PI-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED1 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 21 ENCL 19

gA 0

Indiana Michigan Power Company P.O. Box 16631 Columbus, OH 43216 AEP:NRC:1117 Donald C.

Cook Nuclear Plant Unit 2 Docket No. 50-316 License No.

DPR-74

RESPONSE

TO NRC INFORMATION NOTICE 89-56 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.

20555 Attn: T.

E. Murley:

February 28, l990

Dear Dr. Murley:

Information Notice 89-56, "Questionable Certification oE Material Supplied to the DeEense Department by Nuclear Suppliers,"

was issued to alert licensees to possible problems with certification of material furnished by Meredith Corporation, Pressure Vessel Nuclear and Alloy & Carbon Steel Company.

The NRC expressed interest in the Information Notice in discrepancies discovered by, licensees regarding similar problems with material supplied by the above vendors.

The attachment to this letter provides information relative to use of material purchased from Pressure Vessel Nuclear for the Donald C.

Cook Nuclear Plant Unit 2.

This document has been prepared following Corporate procedures that incorporate a reasonable set of controls to ensure its accuracy and completeness prior to signature by the undersigned.

Sincerely, M. P. Alexich Vice President ldp Attachment 8...900228

,9003120358... 9 PKiR ADGCK

Dr. T. E. Murley AEP:NRC:1117 cc:

D. H. Williams, Jr.

A. A. Blind - Bridgman R.

C. Callen G. Charnoff A. B. Davis

- Region III NRC Resident Inspector

- Bridgman NFEM Section Chief

ATTACHMENT TO AEP:NRC:1117

RESPONSE

TO NRC INFORMATION NOTICE 89-56

'4 f

4 1

1I

~,

f

~

I~

Attachment to AEP:NRC:1117 Page 1

The information below is provided to satisfy an NRC request for information regarding material supplied by Pressure Vessel Nuclear (PVN) and Alloy & Carbon Steel Company, Inc., where discrepancies have been found similar to those described in NRC Information Notice 89-56.

The discussion below only addresses material supplied by PVN; we are unaware of any purchases from Alloy.6 Carbon Steel

Company, Inc.

On October 13,

1989, Anchor Darling Industries, Inc. notified MK-Ferguson Co. that shim material from PVN had been supplied to them for the Donald C.

Cook Nuclear Plant.

This discovery had been made as a result of an investigation conducted pursuant to the issuance of NRC Information Notice 89-56.

MK-Ferguson subsequently informed Indiana Michigan Power that the affected shim materials had been furnished for the steam generator repair project on Unit 2.

Specifically, the shims had been used for the steam generator

upper, and lower lateral restraints and between the support pad and support column.

Review Actions Taken As a result of the above notification, a Problem 'Report was initiated and an investigation conducted by AEPSC. This revealed that three purchase orders were affected.

For two of the orders, PVN supplied an initial Chemical and Material Certification Review and Anchor Darling Industries performed a follow-up certification.

Table 1 summarizes the differences between the two analyses for Heat Trace Codes S-5 and S-13.

As noted in the table, differences exist for the chemical analyses of chromium, copper and vanadium.

The third purchase order required only a certificate of conformance and no Chemical and Material Certification Review.

No analytical results are,'herefore, provided herein for comparison purposes.

Conclusion For the particular application of the material provided by PVN, the completed investigation of all three purchase orders concluded that the material was capable of performing its design function and, therefore, is acceptable for continued use.

~

ri TABLE 1 COMPARISON OF CMTRs FOR HEAT TRACE CODES 5, 13 CHEMICAL CERTIFICATION Specification Chemical 8 Content 0.2 max.

Mn 0.75-01.35 0.04 max.

0.05 max.

Si 0.15-0.50 Ni 0.50 max.

Cr 0.40-0.70 Cu 0.20-0.40 V

0.01-0.10 PVN CMTR Results TC-S-05 TC-S-13 0.170 0.160 1.110

~ 130 0.014 "'.014 0.012 0.013 0 '30 0.320 0.190 0.180 0.470 0.460 0 '80 0.230 0.020 0.030 0 '90 0.210 0.180 0.160 0.17*

0.17*

0.06*

0.02*

<0.01*

0.01*

Anchor Darling CMTR Results TC-S-05 TC-S-13

'I 0.180 0.160 1.090 1.130 0.008 0.006 0.014 0.021 MECHANICAL CERTIFICATION Specification Yield Strength (ksi) min.

50.0 PVN CMTR Results TC-S-05 TC-S-13 54.7 54.0 Anchor Darling CMTR Results TC-S-05 TC-S-13 57.1 53.3 Tensile Strength 70.0 (ksi) min.

77.1 76.1 77.0 76.0 Elongation 8

min.

18 Q 8" 21 Q 2" 30 Q 8" 30 Q 8" 30 Q 2" 32.9 9 2"

  • Indicates nonconformance to specification

~y l

~

J

~t 'g,

(