ACCELERATED DJQRIBUTION DEMON TION SYSIRM V
REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9004030102 DOC.DATE: 90/03/27 NOTARIZED: NO DOCKET ¹
'ACIL:50-316 Donald C.
Cook Nuclear Power Plant, Unit 2, Indiana 05000316 AUTH.NAME AUTHOR AFFILIATION ALEXICH,M.P.
(formerly Indiana 6 Michigan Ele, RECIP.NAME RECIPIENT AFFILIATION DAVIS,A.B.
Document Control Branch (Document Control Desk)
SUBJECT:
Forwards check in payment of $75,000 civil penalty imposed through NOV issued in Insp Rept 50-316/89-28.
DISTRIBUTION CODE: IEI4D COPIES RECEIVED:LTR g ENCL 0 SIZE:
TITLE: Enforcement Action Non-2.790-Licensee
Response
NOTES:
S RECIPIENT ID CODE/NAME PD3-1 LA GIITTER,J.
INTERNAL: AEOD/DOA DEDRO NRR/PMAS/ILRB12 OE D
G FILE RGN2 RS PRPB EXTERNAL: LPDR NSIC COPIES JTTR ENCL RECIPIENT ID CODE/NAME PD3-1 PD AEOD/DSP/TPAB NRR/DOEA/OEAB11 NUDOCS-ABSTRACT OE FILE 01 RGN3 FILE 03 NRC PDR COPIES LTTR ENCL R
NOTE TO ALL"RIDS" RECIPIENT:
PLEASE HELP US TO REDUCE W~! CONTACT THE,DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISIRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED)
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 17
. ENCL
indiana Michigan Power Company P.O. Box 16631 Coiumbus, OH 43216 INDIANA NlCHIGAN POWER AEP:NRC:1125C Donald C.
Cook Nuclear Plant Unit 2 Docket No. 50-316 License No.
DPR-74 NRC INSPECTION REPORT NO. 50-316/89028 (DRP);,
PAYMENT OF $75,000 CIVIL PENALTY U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.
20555 Attn: A.
BE Davis March 27, 1990
Dear Mr. Davis:
Enclosed with this letter is a check in payment of the
$75,000 civil penalty imposed through the Notice of Violation issued in Inspection Report No. 50-316/89028 (DRP).
The Notice of Violation and associated civil penalty resulted from a routine safety inspection conducted at the Cook Nuclear Plant on October 16 through 20, October 24 through 26, and December 4, 1989.
The violation involves the installation of an improperly sized flow orifice in the Cook Nuclear Plant Unit 2 turbine-driven auxiliary feedwater pump (TDAFP) discharge prior to initial plant startup.
This mis-sized orifice resulted in the establishment of an incorrect setpoint in the TDAFP flow retention circuitry which created the potential for TDAFP runout. and subsequent unavailability of this source of auxiliary feedwater following a postulated feedwater or main steam line break.
Our response to the Notice of Violation, including the actions we have completed'o correct the cited deficiency and prevent recurrence, was provided in a separate submittal (AEP:NRC:1125 dated March 27, 1990).
This document has been prepared following Corporate procedures that incorporate a reasonable'set of controls to ensure its accuracy and completeness prior to signature by the undersigned.
Sincerely, M. P. Alexich Vice President ldp Enclosure 90040 0102 500327 FOR ADOCK 05000:.16 9
PDi-.
4 /5, ri41 go<'P
Mr. A.
BE Davis AEP:NRC:1125C cc:
D. H. Williams, Jr.
A. A. Blind - Bridgman R.
C. Callen G. Charnoff NRC Resident Inspector
- Bridgman NFEM Section Chief