Text

OAK RIDGE INSTITUTE FOR SCIENCE AND EDUCATION October 18,2007 Mr. Jim Kottan U.S. Nuclear Regulatory Commission Region I 475 Allendale Road I(mg of Prussia, PA 19406

SUBJECT:

REPORT FOR ANALYSES O F SEVEN WATER SAMPLES FROM SET FIV E FROM THE INDIAN POINT POWER STATION, BUCHANAN, NEW YORK

[INSPECTION REPORT N O . 050-247/2007-0031 [RFTA N O . 07-0041

Dear Mr. Kottan:

The Oak Ridge Institute for Science and Education (ORISE) received set five, consisting of seven wa ter samples associated with the Indian Point Power Station on September 6,2007. Sample analysis was initiated based on the information in RFTA 07-004. Sample identification and collection data for the samples addressed in tlis report are presented in Table 1. Gamma spectroscopy, total radiostrontium nickel-63, and tritium data are provided in Tables 2-5, respectively. The pertinent procedure referenc es are provided in each specific table.

ORISEs Quality Control (QC) requirements were met for these analyses. The Q C files are avadable tor your review upon request.

My contact information is listed below. You may also contact Wade Ivey at 865.576.9184 with any questions or comments.

Sincerely, Dale Condra, Manager Laboratory RDC:WPI:ar Enclosures C: T. Carter, FSME/DWMEP/DD/SP T-8F5 J. White, NRC Regon I E. IOlox-Davin, NRC/FSME/TWF;N 8A23 E. Abelquist, ORISE S Roberts, ORISE J. Commiskey, NRC Region I File 1748 Distribution approval and concurrence : Initials ,,,

Technical hlanagement Team Member <UI-Quality Manager Voice: 865.241.3242 Fax: 865.241.3248 E-mail: Dale.Condra @orau .org

TABLE 1 SAMPLE IDENTIFICATIONS A N D COLLECTION DATA INDIAN POINT POWER STATION BUCHANAN, NEW YORK ORISE NRC Region I Collection Collection Date Sample ID Sample ID Time MW-67-39-(001) I 8/31/2007 I 12:05 11 1748W0028 MW-67-105-(001) I 8/31/2007 I 12:35 11 11 1748W0031 11 1748W0032 11 1748W0033 MW-67-340-(001) I 8/31/2007 I 1254 11 Indian Point Power Station projects/l748/Data Tables/2007-10-18 1748-DT-005-0

TABLE 2 CONCENTRATIONS OF SELECTED GAMMA EMITTING RADIONUCLIDES I N WATER SAMPLES BY GAMMA SPECTROSCOPY CP1, REVISION 15 INDIAN POINT POWER STATION BUCHANAN, NEW YORK T h e MDCs are after the c o m a bUncertmtm represent the 95% confidence level, based on total propagated uncertanhes Zero value IS due to roundmg

TABLE 3 CONCENTRATIONS OF TOTAL RADIOSTRONTIUM I N WATER SAMPLES BY LOW BACKGROUND BETA COUNTING AP4, REVISION 14; CP3, REVISION 2 INDIAN POINT POWER STATION BUCHANAN, NEW YORK Radionuclide ORISE NRC RegionI Concentrations, TPUs, and Sample ID Sample ID M D C ~ (DCi/L) 11-~ 1748W0027

~

I Mw-67-39-(001) I 19.0 3: 1.3b , 0.8 11 1748W0028 Mw-67-105-(001) 1.76 & 0.54 , 0.75 1748W0029 Mw-67-173-(001) 1.21 2 0.52 , 0.78 1748W0030 Mw-67-219-(001) 0.49 k 0.52 . 0.87 lr- 1748W0031 r ~-67-276-(001) 11 1748W0032 I Mw-67-323-(001) 11 1748W0033 I Mw-67-340-(001) -0.07 T h e MDCs are after the comma.

bUncertainties represcnt the 95%)confidence level, based on total propagated uncertainties Indian Point Power Station projects/l748/Data Tables/2007-10-18 1748-DT-005-0

TABLE 4 CONCENTRATIONS OF NICKEL-63 I N WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP12, REVISION 6; CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEW YORK ORISE NRC Region I Concentrations, Sample ID Sample ID TPUs, and MDCS" (PCi / L) 1 1748W0027 I Mw-67-39-(001) I 6.0 k 3.0b , 5.0 1748W0028 MW-67-105-(001) 4.2 k 3.0 , 5.0 1748W0029 MW-67-173-(001) 2.9 k 3.0 , 5.0 1748WO030 MW-67-219-(001) 5.1 2! 3.0 , 5.0 1748W0031 MW-67-276-(001) 5.6 -t 3.0 , 5.0 1748W0032 m-67-323-(001) 3.9 2! 3.0 , 5.0 1748W0033 Mw-67-340-(@01) 3.7 k 3.0 , 5.0 Indian Point Power Station projects/l748/Data Tables/2007 18 1748-DT-005-0

TABLE 5 CONCENTRATIONS OF TRITIUM I N WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP2, REVISION 16; CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEW YORK ORISE NRC Region I Radionuclide Concentrations, Sample ID Sample ID TPUs, and MDCS"(pCi/L) 1748WOO27 MW-67-39-(001) 6,320 -t 420b , 290 1748W0028 Mw-67-105-(001) 2,510  ? 270 , 290 1748W0029 Mw-67-173- (001) 1,200 k 210 , 290 1748W0030 MW-67-219-(001) 1,020 -t 210 , 290 1748W0031 Mw-67-276-(001) 810 & 200 , 290 1748W0032 Mw-67-323-(00 1) 220 k 170 , 290 1748W0033 Mw-67-340-(00 1) 310 k 180 , 290 Indian Point Power Station projects/l748/Data Tables/2007-10-18 1748-DT-005-0