fýeJ i msNoggLe-- FW: GZA Results Page 1 From:
David Winslow <dwinslow@gza.com>
To:
Matt Barvenik <mbarvenik@gza.com>, James Noggle <JDN@nrc.gov>, Joseph J.Adler <jadler@entergy.com>
Date:
03/20/2007 9:06:45 AM
Subject:
FW: GZA Results
Original Message -----
From: "Cathy" <caley@ozarkundergroundlab.com>
To: "Dave Winslow" <dwinslow@gza.com>; "David Rusczyk" <drusczyk@gza.com>
Cc: "Philip Moss" <pmoss @ ozarkundergroundlab.com>
Sent: 3/20/07 9:28 AM
Subject:
GZA Results Hello to all, Here are the latest set of analysis results on the updated spreadsheet.
As always let us know if you have any questions.
Thank you, Cathy Aley Ozark Underground Laboratory
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak mn Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q0766 10 CB5 (control point) 11/13/06 1437 11/20/06 0804 ND ND ND Q0996 10 CB5 (control point) 11/20/06 0804 11/28/06 1335 ND ND ND Q0767 20 CB24 (control point) 11/13/06 1450 11/20/06 0758 516.2
- 0.434 ND 571.8
- 2.95 Q0767D 20 CB24 (control point) 11/13/06 1450 11/20/06 0758 516.3
- 1.49 ND 570.6
- 2.71 Q0997 20 CB24 (control point) 11/20/06 0758 11/28/06 1330 512.6
- 0.347 ND ND Q0997D 20 CB24 (control point) 11/20/06 0758 11/28/06 1330 ND ND ND Q0768 30 Hudson River downstream 11/14/06 1109 11/20/06 1101 516.4
- 0.508 ND 572.0
- 1.60 Q0998 30 Hudson River downstream 11/20/06 1101 11/27/06 1327 519.4
- 0.476 ND ND Q1221 30 Hudson River downstream 11/27/06 1327 12/4/06 0846 ND ND ND Q1221D 30 Hudson River downstream 11/27/06 1327 12/4/06 0846 ND ND ND Q2070 30 Hudson River downstream 1/23/07 1155 2/2/07 1037 514.4
- 0.405 ND ND Q2469 30 Hudson River downstream 2/2/07 1037 2/8/07 1530 515.3
- 0.419 ND ND Q2398 30 Hudson River downstream 2/8/07 1530 2/9/07 1348 ND ND ND Q2551 30 Hudson River downstream 2/9/07 1348 2/10/07 1248 ND ND ND Q2514 30 Hudson River downstream 2/10/07 1248 2/11/07 1055 ND ND IND Q2635 30 Hudson River downstream 2/11/07 1055 2/12/07 1429 ND ND ND Q2850 30 Hudson River downstream 2/12/07 1429 2/13/07 1130 ND ND ND Q2908 30 Hudson River downstream 2/13/07 1130 2/14/07 1156 ND ND ND Q3229 30 Hudson River downstream 2/14/07 1156 2/16/07 1048 ND ND ND Q3295 30 Hudson River downstream 2/16/07 1048 2/19/07 1155 516.2
- 0.361 ND ND Q3492 30 Hudson River downstream 2/19/07 1155 2/21/07 1435 ND ND ND Q3838 30 Hudson River downstream 2/21/07 1435 2/23/07 1317 ND ND ND Q3581 30 Hudson River downstream 2/23/07 1317 2/26/07 1405 ND ND ND Q3929 30 Hudson River downstream 2/26/07 1405 2/28/07 1455 ND ND ND Q3929D 30 Hudson River downstream 2/26/07 1405 2/28/07 1455 ND ND ND Q4154 30 Hudson River downstream 2/28/07 1455 3/2/07 1415 ND ND ND Q4172 30 Hudson River downstream 3/2/07 1415 3/5/07 1505 ND ND ND Q4172D 30 Hudson River downstream 3/2/07 1415 3/5/07 1505 515.6
- 0.382 ND ND Q4543 30 Hudson River downstream 3/5/07 1505 3/7/07 1615 ND ND ND Q4730 30 Hudson River downstream 3/7/07 1615 3/9/07 1330 ND ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 1
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
A I.*
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak un Conc. ppb Peak nm Conc. ppb Q0999 40 Hudson River upstream 11/22/06 0905 11/28/06 1010 ND ND ND Q0999D 40 Hudson River upstream 11/22/06 0905 11/28/06 1010 ND ND ND Q2045 40 Hudson River upstream 1/23/07 1045 2/1/07 1025 515.4
- 0.361 ND ND Q0769 60 MH2 11/13/06 1357 11/20/06 0824 ND ND 569.4
- 1.50 Q1001 60 MI2 11/20/06 0824 11/28/06 0815 ND ND ND Q3926 60 MH2 2/26/07 1302 2/28/07 1135 ND ND ND Q4128 60 MH2 2/28/07 1135 3/2/07 1033 ND ND ND Q4128D 60 MH2 2/28/07 1135 3/2/07 1033 ND ND ND Q4232 60 MH2 3/2/07 1033 3/5/07 0926 ND ND ND Q4605 60 MH2 3/5/07 0926 3/7/07 1114 ND ND ND Q4719 60 M1H2 3/7/07 1114 3/9/07 0742 ND ND ND Q4719D 60 MH2 3/7/07 1114 3/9/07 0742 ND IND ND Q0770 80 MH4 11/14/06 0838 11/20/06 0832 514.9 1.64 ND ND Q1002 80 MH4 11/20/06 0832 11/28/06 0810 515.1 2.17 ND ND Q1002D 80 MH4 11/20/06 0832 11/28/06 0810 515.0 2.17 ND ND Q3927 80 MH4 2/26/07 1243 2/28/07 1007 515.9 883 ND ND Q4129 80 MIH4 2/28/07 1007 3/2/07 0940 515.3 28.2 ND ND Q4233 80 MH4 3/2/07 0940 3/5/07 0906 515.5 8.42 ND ND Q4233D 80 MIH4 3/2/07 0940 3/5/07 0906 515.7 241 ND ND Q4606 80 MH4 3/5/07 0906 3/7/07 1051 515.4 3.80 ND ND Q4606D 80 MH4 3/5/07 0906 3/7/07 1051 516.0 1.10 ND ND Q4721 80 MH14 3/7/07 1051 3/9/07 0754 513.4
- 1.01 ND ND Q3928 90 MH4A 2/26/07 1255 2/28/07 1017 ND ND ND Q4130 90 MH4A 2/28/07 1017 3/2/07 0945 ND ND ND Q4130D 90 MH4A 2/28/07 1017 3/2/07 0945 ND IND ND Q4234 90 MH4A 3/2/07 0945 3/5/07 0902 ND ND ND Q4607 90 MH4A 3/5/07 0902 3/7/07 1040 ND ND ND Q4722 90 M}H4A 3/7/07 1040 3/9/07 0816 ND ND ND Q0771 100 MH5 11/14/06 1415 11/20/06 1000 514.2 0.919 ND ND Q1003 100 MH5 11/20/06 1000 11/27/06 0858 514.9 1.56 ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 2
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
i
- OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nmI Conc. ppb Q1222 100 M1H5 11/28/06 0808 12/5/06 1030 516.0 0.970 ND ND Q2046 100 MH5 1/15/07 1320 2/1/07 0910 515.8 1.50 ND ND Q2046D 100 MH5 1/15/07 1320 2/1/07 0910 515.4 1.25 ND ND Q2434 100 MH5 2/1/07 0910 2/8/07 1020 516.0 10.992 ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 3
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak un Conc. ppb Peak un Conc. ppb Q0766 10 CB5 (control point) 11/13/06 1437 11/20/06 0804 ND ND ND Q0996 10 CB5 (control point) 11/20/06 0804 11/28/06 1335 ND ND ND Q0767 20 CB24 (control point) 11/13/06 1450 11/20/06 0758 516.2
- 0.434 ND 571.8
- 2.95 Q0767D 20 CB24 (control point) 11/13/06 1450 11/20/06 0758 516.3
- 1.49 ND 570.6
- 2.71 Q0997 20 CB24 (control point) 11/20/06 0758 11/28/06 1330 512.6
- 0.347 ND ND Q0997D 20 CB24 (control point) 11/20/06 0758 11/28/06 1330 ND ND ND Q0768 30 Hudson River downstream 11/14/06 1109 11/20/06 1101 516.4
- 0.508 ND 572.0
- 1.60 Q0998 30 Hudson River downstream 11/20/06 1101 11/27/06 1327 519.4
- 0.476 ND ND Q1221 30 Hudson River downstream 11/27/06 1327 12/4/06 0846 ND ND ND Q1221D 30 Hudson River downstream 11/27/06 1327 12/4/06 0846 ND ND ND Q2070 30 Hudson River downstream 1/23/07 1155 2/2/07 1037 514.4
- 0.405 ND IND Q2469 30 Hudson River downstream 2/2/07 1037 2/8/07 1530 515.3
- 0.419 ND ND Q2398 30 Hudson River downstream 2/8/07 1530 2/9/07 1348 ND ND ND Q2551 30 Hudson River downstream 2/9/07 1348 2/10/07 1248 ND ND ND Q2514 30 Hudson River downstream 2/10/07 1248 2/11/07 1055 ND ND ND Q2635 30 Hudson River downstream 2/11/07 1055 2/12/07 1429 ND ND ND Q2850 30 Hudson River downstream 2/12/07 1429 2/13/07 1130 ND ND ND Q2908 30 Hudson River downstream 2/13/07 1130 2/14/07 1156 ND ND ND Q3229 30 Hudson River downstream 2/14/07 1156 2/16/07 1048 ND ND ND Q3295 30 Hudson River downstream 2/16/07 1048 2/19/07 1155 516.2
- 0.361 ND ND Q3492 30 Hudson River downstream 2/19/07 1155 2/21/07 1435 ND ND ND Q3838 30 Hudson River downstream 2/21/07 1435 2/23/07 1317 ND ND ND Q3581 30 Hudson River downstream 2/23/07 1317 2/26/07 1405 ND ND ND Q3929 30 Hudson River downstream 2/26/07 1405 2/28/07 1455 ND ND ND Q3929D 30 Hudson River downstream 2/26/07 1405 2/28/07 1455 ND ND ND Q4154 30 Hudson River downstream 2/28/07 1455 3/2/07 1415 ND ND ND Q4172 30 Hudson River downstream 3/2/07 1415 3/5/07 1505 ND ND ND Q4172D 30 Hudson River downstream 3/2/07 1415 3/5/07 1505 515.6
- 0.382 ND ND Q4543 30 Hudson River downstream 3/5/07 1505 3/7/07 1615 ND ND ND Q4730 30 Hudson River downstream 3/7/07 1615 3/9/07 1330 ND ND IND I
f:\\docs\\coa\\GZA.xls 3/19/2007 1
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Cone. ppb Peak nm Conc. ppb Q0999 40 Hudson River upstream 11/22/06 0905 11/28/06 1010 ND ND ND Q0999D 40 Hudson River upstream 11/22/06 0905 11/28/06 1010 ND ND ND Q2045 40 Hudson River upstream 1/23/07 1045 2/1/07 1025 515.4
- 0.361 ND ND Q0769 60 MH2 11/13/06 1357 11/20/06 0824 ND ND 569.4
- 1.50 Q1001 60 MH2 11/20/06 0824 11/28/06 0815 ND ND ND Q3926 60 MH2 2/26/07 1302 2/28/07 1135 ND ND ND Q4128 60 MH2 2/28/07 1135 3/2/07 1033 ND ND ND Q4128D 60 MH2 2/28/07 1135 3/2/07 1033 ND ND ND Q4232 60 N11H2 3/2/07 1033 3/5/07 0926 ND ND ND Q4605 60 MH2 3/5/07 0926 3/7/07 1114 ND ND ND Q4719 60 MH2 3/7/07 1114 3/9/07 0742 ND ND ND Q4719D 60 MH2 3/7/07 1114 3/9/07 0742 ND ND ND Q0770 80 MH4 11/14/06 0838 11/20/06 0832 514.9 1.64 ND ND Q1002 80 MH4 11/20/060832 11/28/060810 515.1 2.17 ND ND Q1002D 80 MH4 11/20/06 0832 11/28/06 0810 515.0 2.17 ND ND Q3927 80 MH4 2/26/07 1243 2/28/07 1007 515.9 883 ND ND Q4129 80 MH4 2/28/07 1007 3/2/07 0940 515.3 28.2 ND ND Q4233 80 MH4 3/2/07 0940 3/5/07 0906 515.5 8.42 ND ND Q4233D 80 MH4 3/2/07 0940 3/5/07 0906 515.7 241 ND ND Q4606 80 MH4 3/5/07 0906 3/7/07 1051 515.4 3.80 ND ND Q4606D 80 MH4 3/5/07 0906 3/7/07 1051 516.0 1.10 ND ND Q4721 80 MNH4 3/7/07 1051 3/9/07 0754 513.4
- 1.01 ND ND Q3928 90 MH4A 2/26/07 1255 2/28107 1017 ND ND ND Q4130 90 MH4A 2/28/07 1017 3/2/07 0945 ND ND ND Q4130D 90 MIH4A 2/28/07 1017 3/2/07 0945 ND ND ND Q4234 90 MIH4A 3/2/07 0945 3/5/07 0902 ND ND ND Q4607 90 MIH4A 3/5/07 0902 3/7/07 1040 ND ND ND Q4722 90 MIH4A 3/7/07 1040 3/9/07 0816 ND ND ND Q0771 100 MH5 11/14/06 1415 11/20/06 1000 514.2 0.919 ND ND Q1003 100 MH5 11/20/06 1000 11/27/06 0858 514.9 1.56 ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 2
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak mn Conc. ppb Peak nm Conc. ppb Peak nm Cone. ppb Q1222 100 MH5 11/28/06 0808 12/5/06 1030 516.0 0.970 ND ND Q2046 100 MH5 1/15/07 1320 2/1/07 0910 515.8 1.50 ND ND Q2046D 100 M1HI5 1/15/07 1320 2/1/07 0910 515.4 1.25 ND ND Q2434 100 MH5 2/1/07 0910 2/8/07 1020 516.0 0.992 ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 3
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak mn Conc. ppb Peak rm Conc. ppb Q0766 10 CB5 (control point) 11/13/06 1437 11/20/06 0804 ND ND ND Q0996 10 CB5 (control point) 11/20/06 0804 11/28/06 1335 ND ND ND Q0767 20 CB24 (control point) 11/13/06 1450 11/20/06 0758 516.2
- 0.434 ND 571.8
- 2.95 Q0767D 20 CB24 (control point) 11/13/06 1450 11/20/06 0758 516.3
- 1.49 ND 570.6*
2.71 Q0997 20 CB24 (control point) 11/20/06 0758 11/28/06 1330 512.6
- 0.347 ND ND Q0997D 20 CB24 (control point) 11/20/06 0758 11/28/06 1330 ND ND ND Q0768 30 Hudson River downstream 11/14/06 1109 11/20/06 1101 516.4
- 0.508 ND 572.0
- 1.60 Q0998 30 Hudson River downstream 11/20/06 1101 11/27/06 1327 519.4
- 0.476 ND ND Q1221 30 Hudson River downstream 11/27/06 1327 12/4/06 0846 ND ND ND Q1221D 30 Hudson River downstream 11/27/06 1327 12/4/06 0846 ND ND ND Q2070 30 Hudson River downstream 1/23/07 1155 2/2/07 1037 514.4
- 0.405 ND ND Q2469 30 Hudson River downstream 2/2/07 1037 2/8/07 1530 515.3
- 0.419 ND ND Q2398 30 Hudson River downstream 2/8/07 1530 2/9/07 1348 ND ND ND Q2551 30 Hudson River downstream 2/9/07 1348 2/10/07 1248 ND ND ND Q2514 30 Hudson River downstream 2/10/07 1248 2/11/07 1055 ND ND ND Q2635 30 Hudson River downstream 2/11/07 1055 2/12/07 1429 ND ND ND Q2850 30 Hudson River downstream 2/12/07 1429 2/13/07 1130 ND ND ND Q2908 30 Hudson River downstream 2/13/07 1130 2/14/07 1156 ND ND ND Q3229 30 Hudson River downstream 2/14/07 1156 2/16/07 1048 ND ND ND Q3295 30 Hudson River downstream 2/16/07 1048 2/19/07 1155 516.2
- 0.361 ND ND Q3492 30 Hudson River downstream 2/19/07 1155 2/21/07 1435 ND ND ND Q3838 30 Hudson River downstream 2/21/07 1435 2/23/07 1317 ND ND ND Q3581 30 Hudson River downstream 2/23/07 1317 2/26/07 1405 ND ND ND Q3929 30 Hudson River downstream 2/26/07 1405 2/28/07 1455 ND ND ND Q3929D 30 Hudson River downstream 2/26/07 1405 2/28/07 1455 ND ND ND Q4154 30 Hudson River downstream 2/28/07 1455 3/2/07 1415 ND ND ND Q4172 30 Hudson River downstream 3/2/07 1415 3/5/07 1505 ND ND ND Q4172D 30 Hudson River downstream 3/2/07 1415 3/5/07 1505 515.6
- 0.382 ND ND Q4543 30 Hudson River downstream 3/5/07 1505 3/7/07 1615 ND ND ND Q4730 30 Hudson River downstream 3/7/07 1615 3/9/07 1330 ND ND IND I
f:\\docs\\coa\\GZA.xls 3/19/2007 1
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q0999 40 Hudson River upstream 11/22/06 0905 11/28/06 1010 ND ND ND Q0999D 40-Hudson River upstream 11/22/06 0905 11/28/06 1010 ND ND ND Q2045 40 Hudson River upstream 1/23/07 1045 2/1/07 1025 515.4
- 0.361 ND ND Q0769 60 M112 11/13/06 1357 11/20/06 0824 ND ND 569.4
- 1.50 Q1001 60 MH2 11/20/06 0824 11/28/06 0815 ND ND ND Q3926 60 M1H2 2/26/07 1302 2/28/07 1135 ND ND ND Q4128 60 MH2 2/28/07 1135 3/2/07 1033 ND ND
_ND Q4128D 60 MH2 2/28/07 1135 3/2/07 1033 ND ND ND Q4232 60 MH2 3/2/07 1033 3/5/07 0926 ND ND ND Q4605 60 MH2 3/5/07 0926 3/7/07 1114 ND ND ND Q4719 60 MH2 3/7/07 1114 3/9/07 0742 ND ND ND Q4719D 60 MH2 3/7/07 1114 3/9/07 0742 ND ND ND Q0770 80 MH4 11/14/06 0838 11/20/06 0832 514.9 1.64 ND ND Q1002 80 MH4 11/20/06 0832 11/28/06 0810 515.1 2.17 ND ND Q1002D 80 MH4 11/20/06 0832 11/28/06 0810 515.0 2.17 ND ND Q3927 80 MH4 2/26/07 1243 2/28/07 1007 515.9 883 ND ND Q4129 80 MH4 2/28/07 1007 3/2/07 0940 515.3 28.2 ND ND Q4233 80 MH4 3/2/07 0940 3/5/07 0906 515.5 8.42 ND ND Q4233D 80 MH4 3/2/07 0940 3/5/07 0906 515.7 241 ND ND Q4606 80 MH4 3/5/07 0906 3/7/07 1051 515.4 3.80 ND ND Q4606D 80 MH4 3/5/07 0906 3/7/07 1051 516.0 1.10 ND ND Q4721 80 MH4 3/7/07 1051 3/9/07 0754 513.4
- 1.01 ND ND Q3928 90 MH4A 2/26/07 1255 2/28/07 1017 ND ND ND Q4130 90 MH4A 2/28/07 1017 3/2/07 0945 ND ND ND Q4130D 90 MH4A 2/28/07 1017 3/2/07 0945 ND ND ND Q4234 90 MH4A 3/2/07 0945 3/5/07 0902 ND ND ND Q4607 90 MIH4A 3/5/07 0902 3/7/07 1040 ND ND ND Q4722 90 MH4A 3/7/07 1040 3/9/07 0816 ND ND
_ND Q0771 100 MH5 11/14/06 1415 11/20/06 1000 514.2 0.919 ND IND Q1003 100 MR5 11/20/06 1000 11/27/06 0858 514.9 1.56 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 2
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak mu Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q1222 100 M15 11/28/06 0808 12/5/06 1030 516.0 0.970 ND ND Q2046 100 MIH5 1/15/07 1320 2/1/07 0910 515.8 1.50 ND ND Q2046D 100 MH5 1/15/07 1320 2/1/07 0910 515.4 1.25 ND ND Q2434 100 MH5 2/1/07 0910 2/8/07 1020 516.0 0.992 ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 3
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
Table 1.
Results for charcoal samplers analyzed for the presence of fluorescein, eosine and rhodamine WT (RWT) dyes. Peak wavelengths are reported in nanometers (nm); dye concentrations are reported in parts per billion (ppb).Results through 3/9/07 OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q0766 10 CB5 (control point) 11/13/06 1437 11/20/06 0804 ND ND ND Q0996 10 CB5 (control point) 11/20/06 0804 11/28/06 1335 ND ND ND Q0767 20 CB24 (control point) 11/13/06 1450 11/20/06 0758 516.2
- 0.434 ND 571.8
- 2.95 Q0767D 20 CB24 (control point) 11/13/06 1450 11/20/06 0758 516.3
- 1.49 ND 570.6
- 2.71 Q0997 20 CB24 (control point) 11/20/06 0758 11/28/06 1330 512.6
- 0.347 ND ND Q0997D
.20 CB24 (control point) 11/20/06 0758 11/28/06 1330 ND ND ND Q0768 30 Hudson River downstream 11/14/06 1109 11/20/06 1101 516.4
- 0.508 ND 572.0
- 1.60 Q0998 30 Hudson River downstream 11/20/06 1101 11/27/06 1327 519.4
- 0.476 ND ND Q1221 30 Hudson River downstream 11/27/06 1327 12/4/06 0846 ND ND ND Q1221D 30 Hudson River downstream 11/27/06 1327 12/4/06 0846 ND ND ND Q2070 30 Hudson River downstream 1/23/07 1155 2/2/07 1037 514.4
- 0.405 ND ND Q2469 30 Hudson River downstream 2/2/07 1037 2/8/07 1530 515.3
- 0.419 ND ND Q2398 30 Hudson River downstream 2/8/07 1530 2/9/07 1348 ND ND ND Q2551 30 Hudson River downstream 2/9/07 1348 2/10/07 1248 ND ND ND Q2514 30 Hudson River downstream 2/10/07 1248 2/11/07 1055 ND ND ND Q2635 30 Hudson River downstream 2/11/07 1055 2/12/07 1429 ND ND ND Q2850 30 Hudson River downstream 2/12/07 1429 2/13/07 1130 ND ND ND Q2908 30 Hudson River downstream 2/13/07 1130 2/14/07 1156 ND ND ND Q3229 30 Hudson River downstream 2/14/07 1156 2/16/07 1048 ND ND ND Q3295 30 Hudson River downstream 2/16/07 1048 2/19/07 1155 516.2
- 0.361 ND ND Q3492 30 Hudson River downstream 2/19/07 1155 2/21/07 1435 ND iND IND Q3838 30 Hudson River downstream 2/21/07 1435 2/23/07 1317 ND
_ND IND Q3581 30 Hudson River downstream 2/23/07 1317 2/26/07 1405 ND
_ND ND Q3929 30 Hudson River downstream 2/26/07 1405 2/28/07 1455 ND ND ND Q3929D 30 Hudson River downstream 2/26/07 1405 2/28/07 1455 ND ND ND Q4154 30 Hudson River downstream 2/28/07 1455 3/2/07 1415 ND ND ND Q4172 30 Hudson River downstream 3/2/07 1415 3/5/07 1505 ND IND ND Q4172D 30 Hudson River downstream 3/2/07 1415 3/5/07 1505 515.6
- 0.382 ND
_ND f:\\docs\\coa\\GZA.xls 3/19/2007 I
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak mu Conc. ppb Peak mu Conc. ppb Q4543 30 Hudson River downstream 3/5/07 1505 3/7/07 1615 ND ND ND Q4730 30 Hudson River downstream 3/7/07-1615 3/9/07 1330 ND ND ND Q0999 40 Hudson River upstream 11/22/06 0905 11/28/06 1010 ND IND ND Q0999D 40 Hudson River upstream 11/22/06 0905 11/28/06 1010 ND ND ND Q2045 40 Hudson River upstream 1/23/07 1045 2/1/07 1025 515.4
- 0.361 ND ND Q0769 60 MH2 11/13/06 1357 11/20/06 0824 ND ND 569.4
- 1.50 Q1001 60 MIH2 11/20/06 0824 11/28/06 0815 ND ND ND Q3926 60 MH2 2/26/07 1302 2/28/07 1135 ND ND ND Q4128 60 M1H2 2/28/07 1135 3/2/07 1033 ND ND ND Q4128D 60 M1H2 2/28/07 1135 3/2/07 1033 ND ND ND Q4232 60 MH2 3/2/07 1033 3/5/07 0926 ND ND ND Q4605 60 MH2 3/5/07 0926 3/7/07 1114 ND ND ND Q4719 60 MIH2 3/7/07 1114 3/9/07 0742 ND ND ND Q4719D 60 MH2 3/7/07 1114 3/9/07 0742 ND ND ND Q0770 80 MH4 11/14/06 0838 11/20/06 0832 514.9 1.64 ND ND Q1002 80 MH4 11/20/06 0832 11/28/06 0810 515.1 2.17 ND ND Q1002D 80 MH4 11/20/06 0832 11/28/06 0810 515.0 2.17 ND ND Q3927 80 MH4 2/26/07 1243 2/28/07 1007 515.9 883 ND ND Q4129 80 MH4 2/28/07 1007 3/2/07 0940 515.3 28.2 ND ND Q4233 80 MH4 3/2/07 0940 3/5/07 0906 515.5 8.42 ND ND Q4233D 80 MH4 3/2/07 0940 3/5/07 0906 515.7 241 ND ND Q4606 80 MH4 3/5/07 0906 3/7/07 1051 515.4 3.80 ND ND Q4606D 80 MH4 3/5/07 0906 3/7/07 1051 516.0 1.10 ND ND Q4721 80 MH4 3/7/07 1051 3/9/07 0754 513.4
- 1.01 ND ND Q3928 90 MH4A 2/26/07 1255 2/28/07 1017 ND ND ND Q4130 90 MH4A 2/28/07 1017 3/2/07 0945 ND ND ND Q4130D 90 MH4A 2/28/07 1017 3/2/07 0945 ND ND ND Q4234 90 MH4A 3/2/07 0945 3/5/07 0902 ND ND I
ND Q4607 90 MH4A 3/5/07 0902 3/7/07 1040 ND ND I
ND Q4722 90 MH4A 3/7/07 1040 3/9/07 0816 ND ND I
ND f:\\docs\\coa\\GZA.xls 3/19/2007 2
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak rn Conc. ppb Q0771 100 MH5 11/14/06 1415 11/20/06 1000 514.2 0.919 ND IND Q1003 100 MH5 11/20/06 1000 11/27/06 0858 5.14.9 1.56 ND ND Q1222 100 MH5 11/28/06 0808 12/5/06 1030 516.0 0.970 ND ND Q2046 100 MH5 1/15/07 1320 2/1/07 0910 515.8 1.50 ND ND Q2046D 100 MH5 1/15/07 1320 2/1/07 0910 515.4 1.25 ND ND Q2434 100 MH5 2/1/07 0910 2/8/07 1020 516.0 0.992 ND ND Q2375 100 MH5 2/8/07 1020 2/9/07 1100 515.4
- 0.380 ND ND Q2375D 100 MH5 2/8/07 1020 2/9/07 1100 514.5
- 0.378 ND ND Q2492 100 MH5 2/9/07 1100 2/10/07 0853 516.2 1.18 ND ND Q2492D 100 MR5 2/9/07 1100 2/10/07 0853 516.4
- 0.373 ND IND Q2586 100 MH5 2/10/07 0853 2/11/07 0825 516.2 1.39 ND ND Q2586D 100 MH5 2/10/07 0853 2/11/07 0825 ND ND ND Q2612 100 ME5 2/11/07 0825 2/12/07 0855 515.5 19.1 ND ND Q2612D 100 MH5 2/11/07 0825 2/12/07 0855 515.5 23.5 ND ND Q2827 100 MH5 2/12/07 0855 2/13/07 0845 516.3 378 ND ND Q2827D 100 MH5 2/12/07 0855 2/13/07 0845 515.6 285 ND ND Q2885 100 MR5 2/13/07 0845 2/14/07 0830 515.9 637 ND ND Q2885D 100 MH5 2/13/07 0845 2/14/07 0830 516.1 944 ND ND Q3207 100 MH5 2/14/07 0830 2/16/07 0855 515.9 1,960 ND ND Q3207D 100 MH5 2/14/07 0830 2/16/07 0855 516.2 1,250 ND ND Q3330 100 M115 2/16/07 0855 2/19/07 0930 516.0 2,680 ND ND Q3469 100 MH5 2/19/07 0930 2/21/07 0843 515.3 4.59 ND ND Q3815 100 MH5 2/21/07 0743 2/23/07 0824 515.4 6.01 ND ND Q3815D 100 MH5 2/21/07 0743 2/23/07 0824 514.7 16.1 ND ND Q3557 100 MR5 2/23/07 0824 2/26/07 1000 515.4 11.7 ND ND Q3903 100 MH5 2/26/07 1000 2/28/07 0957 515.2 9.03 ND ND Q3903D 100 Ml5 2/26/07 1000 2/28/07 0957 515.3 175 ND ND Q4105 100 MNH5 2/28/07 0957 3/2/07 1000 515.6 10.2 ND ND Q4105D 100 MR5 2/28/07 0957 3/2/07 1000 515.3 2.65 ND IND I
Q4209 100 MR5 3/2/07 1000 3/5/07 0913 ND ND IND I
f:\\docs\\coa\\GZA.xls 3/19/2007 3
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q4579 100 MH5 3/5/07 0913 3/7/07 1046 515.1 29.6 ND ND Q4579D 100 M115 3/5/07 0913 3/7/07 1046 515.3 17.6 ND ND Q4697 100 MH5 3/7/07 1046 3/9/07 0820 515.3 188 ND ND Q4697D 100 MH5 3/7/07 1046 3/9/07 0820 515.3 55.6 ND ND Q0772 120 MH6 11/13/06 1412 11/20/06 0837 ND ND ND Q1004 120 MH6 11/20/06 0837 11/28/06 0808 ND ND ND Q1004D 120 MH6 11/20/06 0837 11/28/06 0808 ND ND ND Q2071 120 M1H6 1/15/07 1314 2/1/07 0940 ND ND ND Q2470 120 M1H6 2/1/07 0940 2/8/07 0826 ND ND IND Q2470D 120 MH6 2/1/07 0940 2/8/07 0826 ND ND ND Q2399 120 MIH6 2/8/07 0826 2/9/07 0830 ND ND ND Q2552 120 MIH6 2/9/07 0830 2/10/07 0854 ND ND ND Q2552D 120 MH6 2/9/07 0830 2/10/07 0854 ND ND ND Q2515 120 MIH6 2/10/07 0854 2/11/07 0850 ND ND ND Q2636 120 MH6 2/11/07 0850 2/12/07 0821 ND ND ND Q2636D 120 MH6 2/11/07 0850 2/12/07 0821 ND ND ND Q2851 120 MH6 2/12/07 0824 2/13/07 0753 ND ND ND Q2851D 120 MH6 2/12/07 0824 2/13/07 0753 ND ND ND Q2909 120 MH6 2/13/07 0753 2/14/07 0817 ND ND ND Q3230 120 MH6 2/14/07 0817 2/16/07 0755 ND ND ND Q3230D 120 MH6 2/14/07 0817 2/16/07 0755 ND ND ND Q3296 120 MH6 2/16/07 0755 2/19/07 0905 ND ND ND Q3296D 120 MH6 2/16/07 0755 2/19/07 0905 ND ND ND Q3493 120 MH6 2/19/07 0905 2/21/07 0855 ND ND ND Q3839 120 MH6 2/21/07 0855 2/23/07 0755 515.3 25.0 ND ND Q3582 120 MIH6 2/23/07 0755 2/26/07 0904 516.5 531 ND ND Q3582D 120 MH6 2/23/07 0755 2/26/07 0904 516.3 399 ND ND Q3930 120 MH6 2/26/07 0804 2/28/07 0921 515.5 165 ND ND Q4155 120 MH6 2/28/07 0921 3/2/07 0839 516.1 374 ND ND Q4155D 120 MH6 2/28/07 0921 3/2/07 0839 516.1 347 ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 4
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q4173 120 MH6 3/2/07 0839 3/5/07 0905 515.4 13.0 ND ND Q4544 120 MH6 3/5/07 0905 3/7/07 0918 515.1 31.5 ND ND Q4544D 120 MH6 3/5/07 0905 3/7/07 0918 515.1 5.92 ND ND Q4731 120 MIH6 3/7/07 0818 3/9/07 0820 515.3 42.7 ND ND Q0773 320 MW-33 11/14/06 0923 11/20/06 1030 514.9 2.73 ND ND Q1005 320 MW-33 11/20/06 1030 11/27/06 0827 515.8 1.95 ND ND Q1223 320 MW-33 11/27/06 0827 12/4/06 1104 515.5 2.27 ND ND Q2072 320 MW-33 1/15/07 1325 2/1/07 0950 515.2 2.53 ND ND Q2401 320 MW-33 2/8/07 0842 2/9/07 0837 ND ND ND Q2553 320 MW-33 2/9/07 0837 2/10/07 0859 ND ND ND Q2516 320 MW-33 2/10/07 0859 2/11/07 0855 ND ND ND Q2637 320 MW-33 2/11/07 0855 2/12/07 0826 ND ND ND Q2852 320 MW-33 2/12/07 0826 2/13/07 0759 ND ND ND Q2910 320 MW-33 2/13/07 0759 2/14/07 0824 ND ND ND Q3231 320 MW-33 2/14/07 0824 2/16/07 0800 515.8
- 0.491 ND ND Q3297 320 MW-33 2/16/07 0800 2/19/07 0910 515.6 0.687 ND ND Q3494 320 MW-33 2/19/07 0910 2/21/07 0904 516.0
- 0.615 ND ND Q3841 320 MW-33 2/21/07 0904 2/23/07 0813 515.6 7.07 ND ND Q3583 320 MW-33 2/23/07 0813 2/26/07 0915 515.4 66.3 ND ND Q3931 320 MW-33 2/26/07 0815 2/28/07 0926 515.5 31.4 ND IND Q4156 320 MW-33 2/28/07 0926 3/2/07 0853 515.3 113 ND ND Q4174 320 MW-33 3/2/07 0853 3/5/07 0857 515.3 209 ND ND Q4545 320 MW-33 3/5/07 0857 3/7/07 0935 515.2 146 ND ND Q4732 320 MW-33 3/7/07 0935 3/9/07 0811 515.4 87.3 ND ND Q0774 330 MW-34 11/14/06 0934 11/20/06 1035 ND ND ND Q1006 330 MW-34 11/20/06 1035 11/27/06 0836 ND ND ND Q1224 330 MW-34 11/27/06 0836 12/4/06 1115 ND ND ND Q2073 330 MW-34 1/15/07 1330 2/1/07 0953 ND ND ND Q2471 330 MW-34 2/1/07 0953 2/8/07 0848 ND ND IND Q2402 330 MW-34 2/8/07 0848 2/9/07 0844 ND ND IND f:\\docs\\coa\\GZA.xls 5
3/19/2007
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak in Conc. ppb Peak rn Cone. ppb Peak nm Conc. vvb Q2554 330 MW-34 2/9/07 0844 2/10/07 0905 ND ND ND Q2517 330 MW-34 2/10/07 0905 2/11/07 0902 ND ND ND Q2638 330 MW-34 2/11/07 0902 2/12/07 0832 ND ND ND Q2853 330 MW-34 2/12/07 0832 2/13/07 0804 ND ND ND Q2911 330 MW-34 2/13/07 0804 2/14/07 0828 ND ND ND Q3232 330 MW-34 2/14/07 0828 2/16/07 0805 ND ND ND Q3298 330 MW-34 2/16/07 0805 2/19/07 0915 ND ND ND Q3495 330 MW-34 2/19/07 0915 2/21/07 0915 ND ND ND Q3842 330 MW-34 2/21/07 0915 2/23/07 0808 ND ND ND Q3584 330 MW-34 2/23/07 0808 2/26/07 0921 ND ND ND Q3932 330 MW-34 2/26/07 0821 2/28/07 0925 ND ND ND Q4157 330 MW-34 2/28/07 0925 3/2/07 0921 ND ND ND Q4175 330 MW-34 3/2/07 0921 3/5/07 0845 ND ND ND Q4546 330 MW-34 3/5/07 0845 3/7/07 1025 ND ND ND Q4733 330 MW-34 3/7/07 1025 3/9/07 0759 ND ND ND Q0775 340 MW-35 11/14/06 0942 11/20/06 1040 ND ND ND Q1007 340 MW-35 11/20/06 1040 11/27/06 0845 ND ND ND Q1225 340 MW-35 11/27/06 0845 12/4/06 1120 ND ND ND Q2047 340 MW-35 1/15/07 1335 2/1/07 1359 ND ND ND Q2435 340 MW-35 2/1/07 1359 2/8/07 1000 ND ND ND Q2376 340 MW-35 2/8/07 1000 2/9/07 1048 ND ND ND Q2493 340 MW-35 2/9/07 1048 2/10/07 0840 ND ND ND Q2587 340 MW-35 2/10/07 0840 2/11/07 0810 ND ND ND Q2613 340 MW-35 2/11/07 0810 2/12/07 0913 ND ND ND Q2828 340 MW-35 2/12/07 0916 2/13/07 1055 ND ND ND Q2886 340 MW-35 2/13/07 1055 2/14/07 0815 ND ND ND Q3208 340 MW-35 2/14/07 0815 2/16/07 0820 ND ND ND Q3331 340 MW-35 2/16/07 0820 2/19/07 0920 ND ND ND Q3470 340 MW-35 2/19/07 0920 2/21/07 0835 ND ND ND Q3816 340 MW-35 2/21/07 0835 2/23/07 0804 ND ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 6
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q3558 340 MW-35 2/23/07 0804 2/26/07 0953 ND ND ND Q3904 340 MW-35 2/26/07 0953 2/28/07 0930 516.8
- 0.52 ND ND Q4106 340 MW-35 2/28/07 0930 3/2/07 0925 ND ND ND Q4210 340 MW-35 3/2/07 0925 3/5/07 0848 515.2
- 0.495 ND ND Q4581 340 MW-35 3/5/07 0848 3/7/07 1028 516.2
- 0.601 ND ND Q4698 340 MW-35 3/7/07 1028 3/9/07 0803 ND ND ND Q0776 350 MW-36-26 11/14/06 1344 11/20/06 1130 ND ND ND Q1008 350 MW-36-26 11/20/06 1130 11/27/06 1110 ND ND IND Q1226 350 MW-36-26 11/27/06 1110 12/5/06 1135 ND ND ND Q2048 350 MW-36-26 1/15/07 1303 2/1/07 1059 ND ND ND Q2436 350 MW-36-26 2/1/07 1059 2/8/07 1045 ND ND ND Q2377 350 MW-36-26 2/8/07 1045 2/9/07 1114 ND ND ND Q2494 350 MW-36-26 2/9/07 1114 2/10/07 0908 ND ND ND Q2588 350 MW-36-26 2/10/07 0908 2/11/07 0835 ND ND ND Q2614 350 MW-36-26 2/11/07 0835 2/12/07 0935 ND ND IND Q2829 350 MW-36-26 2/12/07 0935 2/13/07 1435 ND ND ND Q2887 350 MW-36-26 2/13/07 1435 2/14/07 1050 ND ND ND Q3209 350 MW-36-26 2/14/07 1050 2/16/07 0905 ND ND ND Q3332 350 MW-36-26 2/16/07 0905 2/19/07 0945 ND ND ND Q3471 350 MW-36-26 2/19/07 0945 2/21/07 0852 ND ND ND Q3817 350 MW-36-26 2/21/07 0852 2/23/07 0833 ND ND ND Q3559 350 MW-36-26 2/23/07 0833 2/26/07 1008 ND ND ND Q3905 350 MW-36-26 2/26/07 1008 2/28/07 1027 ND ND
_ND Q4107 350 MW-36-26 2/28/07 1027 3/2/07 0900 ND ND ND Q4211 350 MW-36-26 3/2/07 0900 3/5/07 1103 ND ND
_ND Q4582 350 MW-36-26 3/5/07 1103 3/7/07 1345 ND ND IND Q4699 350 MW-36-26 3/7/07 1345 3/9/07 0940 ND ND ND Q0777 360 MW-36-41 11/14/06 1358 11/20/06 1140 ND ND ND Q1009 360 MW-36-41 11/20/06 1140 11/27/06 1106 ND ND ND Q1227 360 MW-36-41 11/27/06 1106 12/5/06 1121 ND ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 7
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Cone. ppb Peak nm Conc. ppb Q2049 360 MW-36-41 1/15/07 1254 2/1/07 1106 ND ND ND Q2437 360 MW-36-41 2/1/07 1106 2/8/07 1050 ND ND ND Q2378 360 MW-36-41 2/8/07 1050 2/9/07 1117 ND ND ND Q2495 360 MW-36-41 2/9/07 1117 2/10/07 0913 ND ND ND Q2589 360 MW-36-41 2/10/07 0913 2/11/07 0839 ND ND ND Q2611 360 MW-49-42 2/9/07 1325 2/11/07 1425 ND ND ND Q2615 360 MW-36-41 2/11/07 0839 2/12/07 0940 ND ND ND Q2830 360 MW-36-41 2/12/07 0940 2/13/07 1440 ND ND ND Q2888 360 MW-36-41 2/13/07 1440 2/14/07 1055 ND ND ND Q3210 360 MW-36-41 2/14/07 1055 2/16/07 0910 ND ND ND Q3333 360 MW-36-41 2/16/07 0910 2/19/07 0948 ND ND
_ND Q3472 360 MW-36-41 2/19/07 0948 2/21/07 0856 ND
.ND 1MND Q3818 360 MW-36-41 2/21/07 0856 2/23/07 0830 ND ND ND Q3561 360 MW-36-41 2/23/07 0838 2/26/07 1012 ND ND ND Q3906 360 MW-36-41 2/26/07 1012 2/28/07 1031 ND ND ND Q4108 360 MW-36-41 2/28/07 1031 3/2/07 0903 ND ND ND Q4212 360 MW-36-41 3/2/07 0903 3/5/07 1107 515.8
- 0.323 ND ND Q4583 360 MW-36-41 3/5/07 1107 3/7/07 1349 ND ND ND Q4701 360 MW-36-41 3/7/07 1349 3/9/07 0944 ND ND ND Q0778 370 MW-36-53 11/14/06 1406 11/20/06 1150 ND ND ND Q1010 370 MW-36-53 11/20/06 1150 11/27/06 1058 ND ND ND Q1228 370 MW-36-53 11/27/06 1058 12/5/06 1125 ND ND ND Q2050 370 MW-36-53 1/15/07 1258 2/1/07 1102 ND ND ND Q2438 370 MW-36-53 2/1/07 1102 2/8/07 1055 ND ND ND Q2379 370 MW-36-53 2/8/07 1055 2/9/07 1121 ND ND
_ND Q2496 370 MW-36-53 2/9/07 1121 2/10/07 0918 ND ND IND Q2590 370 MW-36-53 2/10/07 0918 2/11/07 0843 ND ND ND Q2616 370 MW-36-53 2/11/07 0843 2/12/07 0945 ND ND ND Q2831 370 MW-36-53 2/12/07 0945 2/13/07 1445 ND ND ND Q2889 370 MW-36-53 2/13/07 1445 2/14/07 1100 ND ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 8
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak mn Conc. ppb Peak nm Conc. ppb Q3211 370 MW-36-53 2/14/07 1100 2/16/07 0915 ND ND ND Q3334 370 MW-36-53 2/16/07 0915 2/19/07 0953 ND ND ND Q3473 370 MW-36-53 2/19/07 0953 2/21/07 0900 ND ND ND Q3819 370 MW-36-53 2/21/07 0900 2/23/07 0843 ND ND ND Q3562 370 MW-36-53 2/23/07 0843 2/26/07 1017 ND ND ND Q3907 370 MW-36-53 2/26/07 1017 2/28/07 1036 ND ND ND Q4109 370 MW-36-53 2/28/07 1036 3/2/07 0907 ND ND ND Q4213 370 MW-36-53 3/2/07 0907 3/5/07 1112 ND ND ND Q4584 370 MW-36-53 3/5/07 1112 3/7/07 1354 ND ND ND Q4702 370 MW-36-53 3/7/07 1354 3/9/07 0948 ND ND ND Q0779 380 MW-37-22 11/14/06 1424 11/20/06 1026 ND ND ND Q1011 380 MW-37-22 11/20/06 1026 11/27/06 1049 ND ND ND Q1229 380 MW-37-22 11/27/06 1049 12/4/06 1337 ND ND ND Q2074 380 MW-37-22 1/15/07 1242 2/1/07 1016 ND ND ND Q2472 380 MW-37-22 2/1/07 1016 2/8/07 1000 ND ND ND Q2403 380 MW-37-22 2/8/07 1000 2/9/07 0854 ND ND ND Q2555 380 MW-37-22 2/9/07 0854 2/10/07 0915 ND ND ND Q2518 380 MW-37-22 2/10/07 0915 2/11/07 0912 ND ND ND Q2639 380 MW-37-22 2/11/07 0912 2/12/07 0840 ND ND ND Q2854 380 MW-37-22 2/12/07 0840 2/13/07 0811 ND ND ND Q2912 380 MW-37-22 2/13/07 0811 2/14/07 0837 ND ND ND Q3233 380 MW-37-22 2/14/07 0837 2/16/07 0818 ND ND ND Q3299 380 MW-37-22 2/16/07 0818 2/19/07 0925 ND ND ND Q3496 380 MW-37-22 2/19/07 0925 2/21/07 0857 ND ND ND Q3843 380 MW-37-22 2/21/07 0957 2/23/07 0825 ND ND ND Q3585 380 MW-37-22 2/23/07 0825 2/26/07 0935 517.0
- 0.716 ND ND Q3933 380 MW-37-22 2/26/07 0835 2/28/07 0948 515.8 2.91 ND ND Q4158 380 MW-37-22 2/28/07 0948 3/2/070804 515.2 10.0 ND ND Q4176 380 MW-37-22 3/2/07 0804 3/5/07 0912 515.1 28.9 ND ND Q4547 380 MW-37-22 3/5/07 0912 3/7/07 1040 515.0 90.0 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 9
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Cone. ppb Peak nm Cone. ppb Peak un Conc. ppb Q4734 380 MW-37-22 3/7/07 1040 3/9/07 0830 515.3 99.8 ND ND Q0781 390 MW-37-32 11/14/06 1434 11/20/06 1018 ND ND ND Q1012 390 MW-37-32 11/20/06 1018 11/27/06 1018 ND ND ND Q1230 390 MW-37-32 11/27/06 1018 12/4/06 1328 ND ND ND Q2075 390 MW-37-32 1/15/07 1213 2/1/07 1009 ND ND ND Q2473 390 MW-37-32 2/1/07 1009 2/8/07 1004 ND ND ND Q2404 390 MW-37-32 2/8/07 1004 2/9/07 0856 ND ND ND Q2556 390 MW-37-32 2/9/07 0856 2/10/07 0917 ND ND ND Q2519 390 MW-37-32 2/10/07 0917 2/11/07 0913 ND ND ND Q2641 390 MW-37-32 2/11/07 0913 2/12/07 0842 ND ND ND Q2855 390 MW-37-32 2/12/07 0842 2/13/07 0814 ND ND ND Q2913 390 MW-37-32 2/13/07 0814 2/14/07 0839 ND ND ND Q3234 390 MW-37-32 2/14/07 0839 2/16/07 0820 ND ND ND Q3301 390 MW-37-32 2/16/07 0820 2/19/07 0930 ND ND IND Q3497 390 MW-37-32 2/19/07 0930 2/21/07 0959 ND ND ND Q3844 390 MW-37-32 2/21/07 0959 2/23/07 0829 ND ND ND Q3586 390 MW-37-32 2/23/07 0829 2/26/07 0935 ND ND ND Q3934 390 MW-37-32 2/26/07 0835 2/28/07 0952 ND ND ND Q4159 390 MW-37-32 2/28/07 0952 3/2/07 0808 ND ND ND Q4177 390 MW-37-32 3/2/07 0808 3/5/07 0917 515.8 0.831 ND ND Q4548 390 MW-37-32 3/5/07 0917 3/7/07 1043 516.1
- 0.767 ND ND Q4735 390 MW-37-32 3/7/07 1043 3/9/07 0835 515.7 1.8 ND IND Q0782 400 MW-37-40 11/14/06 1444 11/20/06 0958 ND ND ND Q1013 400 MW-37-40 11/20/06 0958 11/27/06 1038 ND ND ND Q1231 400 MW-37-40 11/27/06 1038 12/4/06 1140 ND ND ND Q2076 400 MW-37-40 1/15/07 1234 2/1/07 1021 ND ND ND Q2474 400 MW-37-40 2/1/07 1021 2/8/07 1011 ND ND IND Q2405 400 MW-37-40 2/8/07 1011 2/9/07 0900 ND ND ND Q2557 400 MW-37-40 2/9/07 0900 2/10/07 0921 ND ND ND Q2521 400 MW-37-40 2/10/07 0921 2/11/07 0916 ND ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 10
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak mn Cone. ppb Q2642 400 MW-37-40 2/11/07 0916 2/12/07 0845 ND ND ND Q2856 400 MW-37-40 2/12/07 0845 2/13/07 0816 ND ND ND Q2914 400 MW-37-40 2/13/07 0816 2/14/07 0842 ND ND ND Q3235 400 MW-37-40 2/14/07 0842 2/16/07 0822 ND ND ND Q3302 400 MW-37-40 2/16/07 0822 2/19/07 0933 ND ND ND Q3498 400 MW-37-40 2/19/07 0933 2/21/07 1005 ND ND ND Q3845 400 MW-37-40 2/21/07 1005 2/23/07 0833 ND ND ND Q3587 400 MW-37-40 2/23/07 0833 2/26/07 0943 ND ND ND Q3935 400 MW-37-40 2/26/07 0843 2/28/07 0958 ND ND ND Q4161 400 MW-37-40 2/28/07 0958 3/2/07 0813 ND ND ND Q4178 400 MW-37-40 3/2/07 0813 3/5/07 0921 ND ND ND Q4549 400 MW-37-40 3/5/07 0921 3/7/07 1051 ND ND ND Q4736 400 MW-37-40 3/7/07 1051 3/9/07 0841 ND ND ND Q0783 410 MW-37-57 11/14/06 1456 11/20/06 1011 ND ND ND Q1014 410 MW-37-57 11/20/06 1011 11/27/06 1032 ND ND ND Q1232 410 MW-37-57 11/27/06 1032 12/4/06 1148 ND ND ND Q2077 410 MW-37-57 1/15/07 1221 2/1/07 1041 ND ND ND Q2475 410 MW-37-57 2/1/07 1041 2/8/07 1047 ND ND ND Q2406 410 MW-37-57 2/8/07 1047 2/9/07 0904 ND ND IND Q2558 410 MW-37-57 2/9/07 0904 2/10/07 0935 ND ND ND Q2522 410 MW-37-57 2/10/07 0935 2/11/07 0920 ND ND ND Q2643 410 MW-37-57 2/11/07 0920 2/12/07 0850 ND ND ND Q2857 410 MW-37-57 2/12/07 0850 2/13/07 0820 ND ND ND Q2915 410 MW-37-57 2/13/07 0820 2/14/07 0845 ND ND ND Q3236 410 MW-37-57 2/14/07 0845 2/16/07 0825 ND ND ND Q3303 410 MW-37-57 2/16/07 0825 2/19/07 0935 ND ND ND Q3499 410 MW-37-57 2/19/07 0935 2/21/07 1010 ND ND ND Q3846 410 MW-37-57 2/21/07 1010 2/23/07 0840 ND ND ND Q3588 410 MW-37-57 2/23/07 0840 2/26/07 0948 ND ND IND Q3936 410 MW-37-57 2/26/07 0848 2/28/07 1004 ND -ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 11
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q4162 410 MW-37-57 2/28/07 1004 3/2/07 0817 ND ND ND Q4179 410 MW-37-57 3/2/07 0817 3/5/07 0938 ND ND ND Q4550 410 MW-37-57 3/5/07 0938 3/7/07 1057 ND ND ND Q4737 410 MW-37-57 3/7/07 1057 3/9/07 0847 ND ND ND Q0784 420 MW-38 11/14/06 1109 11/20/06 1053 ND ND 567.6
- 1.34 Q1015 420 MW-38 11/20/06 1053 11/27/06 1317 ND ND ND Q1233 420 MW-38 11/27/06 1317 12/4/06 0856 ND ND ND Q1913 420 MW-38 1/12/07 1330 1/17/07 1441 ND ND ND Q3264 420 MW-38 1/17/07 1441 2/15/07 1055 ND ND ND Q4084 420 MW-38 2/15/07 1055 3/1/07 1400 ND ND ND Q0785 440 MW-39A (67')
11/17/06 1403 11/21/06 0826 ND ND ND Q1016 440 MW-39A (67')
11/21/06 0826 11/28/06 1114 ND ND ND Q1234 440 MW-39A (67')
11/28/06 1114 12/6/06 1423 ND ND ND Q1914 440 MW-39A (67')
1/10/07 1040 1/24/07 1040 ND ND ND Q3265 440 MW-39A (67')
1/24/07 1040 2/8/07 1130 ND ND ND Q0786 450 MW-39B (86')
11/17/06 1400 11/21/06 0829 ND ND ND Q1017 450 MW-39B (86')
11/21/06 0829 11/28/06 1122 ND ND ND Q1235 450 MW-39B (86')
11/28/06 1122 12/6/06 1424 ND ND ND Q1915 450 MW-39B (86')
1/10/07 1040 1/24/07 1040 ND ND ND Q3266 450 MW-39B (86')
1/24/07 1040 2/8/07 1130 ND ND ND Q0787 460 MW-39C (100')
11/17/06 1355 11/21/06 0850 ND ND ND Q1018 460 MW-39C (100')
11/21/06 0850 11/28/06 1126 ND ND ND Q1236 460 MW-39C (100')
11/28/06 1126 12/6/06 1425 ND ND ND Q1916 460 MW-39C (100')
1/10/07 1040 1/24/07 1040 ND ND ND Q3267 460 MW-39C (100')
1/24/07 1040 2/8/07 1130 ND ND ND Q1237 470 MW-39D (105')
11/28/06 1130 12/6/06 1426 ND ND ND Q1917 470 MW-39D (105')
1/10/07 1040 1/24/07 1040 ND ND IND Q3268 470 MW-39D (105')
1/24/07 1040 2/8/07 1130 ND ND ND Q0825 473 MW-41-15 11/15/06 1130 11/20/06 1400 ND IND ND Q1057 473 MW-41-15 11/20/06 1400 11/27/06 1425 ND IND ND f:\\docs\\coa\\GZA.xls 3/19/2007 12
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak rn Conc. ppb Peak mu Conc. ppb Peak mn Conc. ppb Q1238 473 MW-41-15 11/27/06 1425 12/7/06 1101 ND ND ND Q1918 473 MW-41-15 1/16/07 0819 1/24/07 1126 ND ND ND Q3269 473 MW-41-15 1/24/07 1126 2/15/07 1325 ND ND ND Q0827 474 MW-41-42 11/15/06 1200 11/20/06 1408 ND ND ND Q1058 474 MW-41-42 11/20/06 1404 11/27/06 1430 ND ND ND Q1239 474 MW-41-42 11/27/06 1430 12/7/06 1122 ND ND ND Q1919 474 MW-41-42 1/16/07 0817 1/24/07 1130 ND ND ND Q3270 474 MW-41-42 1/24/07 1130 2/15/07 1330 ND ND ND Q0826 475 MW-41-64 11/15/06 1140 11/20/06 1404 ND ND ND Q1059 475 MW-41-64 11/20/06 1408 11/27/06 1420 ND ND ND Q1241 475 MW-41-64 11/27/06 1420 12/7/06 1106 ND ND ND Q1921 475 MW-41-64 1/16/07 0811 1/24/07 1135 ND ND ND Q3271 475 MW-41-64 1/24/07 1135 2/15/07 1315 ND ND ND Q0788 480 MW-42-51 11/16/06 1500 11/21/06 0938 ND ND ND Q1019 480 MW-42-51 11/21/06 0938 11/28/06 1320 ND ND ND Q1242 480 MW-42-51 11/28/06 1320 12/6/06 1327 ND ND ND Q1922 480 MW-42-51 1/9/07 1428 1/24/07 1307 ND ND ND Q3272 480 MW-42-51 1/24/07 1307 2/15/07 0825 ND ND ND Q4085 480 MW-42-51 2/15/07 0825 3/1/07 1510 515.4 173 ND ND Q4152 480 MW-42-51 3/1/07 1510 3/2/07 1332 515.3 6.92 ND ND Q4207 480 MW-42-51 3/2/07 1332 3/5/07 1343 515.8 0.926 ND ND Q4577 480 MW-42-51 3/5/07 1343 3/7/07 1540 515.2 1.36 ND ND Q4758 480 MW-42-51 3/7/07 1540 3/9/07 1151 516.3 0.720 ND ND Q0789 490 MW-42-79 11/16/06 1059 11/21/06 0943 ND ND
_ND Q1021 490 MW-42-79 11/21/06 0943 11/28/06 1312 ND ND
_ND Q1243 490 MW-42-79 11/28/06 1312 12/6/06 1310 ND ND ND Q1923 490 MW-42-79 1/9/07 1433 1/24/07 1314 ND ND ND Q3273 490 MW-42-79 1/24/07 1314 2/15/07 0830 515.3 18.4 ND ND Q4086 490 MW-42-79 2/15/07 0830 3/1/07 1515 515.3 63.4 ND ND Q4153 490 MW-42-79 3/1/07 1515 3/2/07 1338 515.5 4.25 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 13
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q4208 490 MW-42-79 3/2/07 1338 3/5/07 1350 515.3 19.1 ND ND Q4578 490 MW-42-79 3/5/07 1350 3/7/07 1548 515.2 54.9 ND ND Q4759 490 MW-42-79 3/7/07 1548 3/9/07 1200 515.1 26.7 ND ND Q0790 510 MW-47-56 11/16/06 0925 11/21/06 1000 ND ND ND Q1022 510 MW-47-56 11/21/06 1000 11/28/06 1050 ND ND ND Q1244 510 MW-47-56 11/28/06 1050 12/6/06 1408 ND ND ND Q1929 510 MW-47-56 1/12/07 1447 1/24/07 1143 ND ND ND Q3274 510 MW-47-56 1/24/07 1143 2/15/07 0955 ND ND ND Q4089 510 MW-47-56 2/15/07 0955 3/1/07 1509 ND ND ND Q4596 510 MW-47-56 3/7/07 0918 ND ND ND Q4728 510 MW-47-56 3/7/07 0923 3/9/07 1057 ND ND IND Q0791 520 MW-47-80 11/16/06 0934 11/21/06 1008 ND ND ND Q1023 520 MW-47-80 11/21/06 1008 11/28/06 1045 ND ND ND Q1245 520 MW-47-80 11/28/06 1045 12/6/06 1358 ND ND ND Q1930 520 MW-47-80 1/12/07 1500 1/24/07 1151 ND ND ND Q3275 520 MW-47-80 1/24/07 1151 2/13/07 1000 ND ND ND Q4090 520 MW-47-80 2/13/07 1000 3/1/07 1514 ND ND ND Q4595 520 MW-47-80 3/7/07 0923 ND ND ND Q4729 520 MW-47-80 3/7/07 0918 3/9/07 1101 ND ND ND Q1246 550 MW-49-26 11/29/06 1126 12/7/06 0840 ND ND IND Q2051 550 MW-49-26 1/15/07 1402 2/1/07 1328 ND ND ND Q2439 550 MW-49-26 2/1/07 1328 2/8/07 1515 ND ND ND Q2381 550 MW-49-26 2/8/07 1515 2/9/07 1335 ND ND ND Q2497 550 MW-49-26 2/9/07 1335 2/10/07 0950 ND ND ND Q2591 550 MW-49-26 2/10/07 0950 2/11/07 0925 ND ND ND Q2617 550 MW-49-26 2/11/07 0925 2/12/07 1405 ND ND ND Q2832 550 MW-49-26 2/12/07 1405 2/13/07 1145 ND ND ND Q2890 550 MW-49-26 2/13/07 1145 2/14/07 0840 ND ND ND Q3212 550 MW-49-26 2/14/07 0840 2/16/07 1310 ND ND ND Q3335 550 MW-49-26 2/16/07 1310 2/19/07 1012 ND ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 14
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak rum Conc. ppb Q3474 550 MW-49-26 2/19/07 1012 2/21/07 0955 ND ND ND Q3821 550 MW-49-26 2/21/07 0955 2/23/07 0900 ND ND ND Q3563 550 MW-49-26 2/23/07 0900 2/26/07 0830 ND ND ND Q3908 550 MW-49-26 2/26/07 0830 2/28/07 1310 ND ND ND Q4110 550 MW-49-26 2/28/07 1310 3/2/07 1320 ND ND ND Q4214 550 MW-49-26 3/2/07 1320 3/5/07 1000 ND ND ND Q4585 550 MW-49-26 3/5/07 1000 3/7/07 0949 ND ND ND Q4703 550 MW-49-26 3/7/07 0949 3/9/07 1005 ND ND ND Q1247 560 MW-49-42 11/29/06 1136 12/7/06 0836 ND ND ND Q2052 560 MW-49-42 1/15/07 1411 2/1/07 1338 ND ND ND Q2441 560 MW-49-42 2/1/07 1338 2/8/07 1520 ND ND ND Q2382 560 MW-49-42 2/8/07 1520 2/9/07 1325 ND ND ND Q2592 560 MW-49-42 2/10/07 0954 2/11/07 0930 ND ND IND Q2618 560 MW-49-42 2/11/07 0930 2/12/07 1410 ND ND ND Q2833 560 MW-49-42 2/12/07 1410 2/13/07 1150 ND ND ND Q2891 560 MW-49-42 2/13/07 1150 2/14/07 0845 ND ND ND Q3213 560 MW-49-42 2/14/07 0845 2/16/07 1315 ND ND ND Q3336 560 MW-49-42 2/16/07 1315 2/19/07 1008 ND ND ND Q3475 560 MW-49-42 2/19/07 1208 2/21/07 1000 ND ND ND Q3822 560 MW-49-42 2/21/07 1000 2/23/07 0905 ND ND ND Q3564 560 MW-49-42 2/23/07 0905 2/26/07 0835 ND ND ND Q3909 560 MW-49-42 2/26/07 0835 2/28/07 1315 ND ND ND Q4111 560 MW-49-42 2/28/07 1315 3/2/07 1325 ND ND ND Q4215 560 MW-49-42 3/2/07 1325 3/5/07 1005 ND ND ND Q4586 560 MW-49-42 3/5/07 1005 3/7/07 0953 ND ND ND Q4704 560 MW-49-42 3/7/07 0953 3/9/07 1010 ND ND ND Q1248 570 MW-49-65 11/29/06 1142 12/7/06 0825 ND ND ND Q2053 570 MW-49-65 1/15/07 1406 2/1/07 1330 ND ND ND Q2442 570 MW-49-65 2/1/07 1330 2/8/07 1525 ND ND ND Q2383 570 MW-49-65 2/8/07 1525 2/9/07 1328 ND ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 15
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q2498 570 MW-49-65 2/9/07 1328 2/10/07 0958 ND ND ND Q2593 570 MW-49-65 2/10/07 0958 2/11/07 0935 ND ND ND Q2619 570 MW-49-65 2/11/07 0935 2/12/07 1415 ND ND ND Q2834 570 MW-49-65 2/12/07 1415 2/13/07 1155 ND ND ND Q2892 570 MW-49-65 2/13/07 1155 2/14/07 0850 ND ND IND Q3214 570 MW-49-65 2/14/07 0850 2/16/07 1320 ND ND ND Q3337 570 MW-49-65 2/16/07 1320 2/19/07 1024 ND ND ND Q3476 570 MW-49-65 2/19/07 1024 2/21/07 1005 ND ND ND Q3823 570 MW-49-65 2/21/07 1005 2/23/07 0910 ND ND ND Q3565 570 MW-49-65 2/23/07 0910 2/26/07 0840 ND ND ND Q3910 570 MW-49-65 2/26/07 0840 2/28/07 1320 ND ND ND Q4112 570 MW-49-65 2/28/07 1320 3/2/07 1330 ND ND ND Q4216 570 MW-49-65 3/2/07 1330 3/5/07 1010 ND ND ND Q4587 570 MW-49-65 3/5/07 1010 3/7/07 0959 ND ND ND Q4705 570 MW-49-65 3/7/07 0959 3/9/07 1015 ND ND ND Q0792 580 MW-50-42 11/14/06 1450 11/20/06 0840 ND ND ND Q1024 580 MW-50-42 11/20/06 0840 11/27/06 0931 ND ND ND Q1249 580 MW-50-42 11/27/06 0951 12/5/06 1425 ND ND ND Q2078 580 MW-50-42 1/15/07 1020 2/1/07 1049 ND ND ND Q2476 580 MW-50-42 2/1/07 1049 2/8/07 1114 ND ND ND Q2407 580 MW-50-42 2/8/07 1114 2/9/07 1040 ND ND ND Q2559 580 MW-50-42 2/9/07 1040 2/10/07 0946 ND ND ND Q2523 580 MW-50-42 2/10/07 0946 2/11/07 0929 ND ND ND Q2644 580 MW-50-42 2/11/07 0929 2/12/07 1057 ND ND ND Q2858 580 MW-50-42 2/12/07 1057 2/13/07 0828 ND ND ND Q2916 580 MW-50-42 2/13/07 0828 2/14/07 0854 ND ND ND Q3237 580 MW-50-42 2/14/07 0854 2/16/07 0833 ND ND ND Q3304 580 MW-50-42 2/16/07 0833 2/19/07 0940 ND ND ND Q3501 580 MW-50-42 2/19/07 0940 2/21/07 1023 ND ND ND Q3847 580 MW-50-42 2/21/07 1023 2/23/07 0851 ND ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 16
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak rn Conc. ppb Peak un Conc. ppb Q3589 580 MW-50-42 2/23/07 0851 2/26/07 1001 ND ND ND Q3937 580 MW-50-42 2/26/07 1001 2/28/07 1016 ND ND ND Q4163 580 MW-50-42 2/28/07 1016 3/2/07 0904 ND ND ND Q4181 580 MW-50-42 3/2/07 0904 3/5/07 0950 ND ND ND Q4551 580 MW-50-42 3/5/07 0950 3/7/07 1120 ND ND ND Q4738 580 MW-50-42 3/7/07 1120 3/9/07 0940 ND ND
_ND Q0793 590 MW-50-67 11/14/06 1440 11/20/06 0820 ND ND ND Q1025 590 MW-50-67 11/20/06 0820 11/27/06 1004 ND ND ND Q1250 590 MW-50-67 11/27/06 1004 12/5/06 1422 ND ND ND Q2079 590 MW-50-67 1/15/07 1035 2/1/07 1101 ND ND ND Q2477 590 MW-50-67 2/1/07 1101 2/8/07 1121 ND ND ND Q2408 590 MW-50-67 2/8/07 1121 2/9/07 1042 ND ND ND Q2561 590 MW-50-67 2/9/07 1042 2/10/07 0948 ND ND ND Q2524 590 MW-50-67 2/10/07 0948 2/11/07 0933 ND ND ND Q2645 590 MW-50-67 2/11/07 0933 2/12/07 1102 ND ND ND Q2859 590 MW-50-67 2/12/07 1102 2/13/07 0831 ND ND ND Q2917 590 MW-50-67 2/13/07 0831 2/14/07 0855 ND ND ND Q3238 590 MW-50-67 2/14/07 0855 2/16/07 0835 ND ND ND Q3305 590 MW-50-67 2/16/07 0835 2/19/07 0945 ND ND ND Q3502 590 MW-50-67 2/19/07 0945 2/21/07 1028 ND ND ND Q3848 590 MW-50-67 2/21/07 1028 2/23/07 0858 ND ND ND Q3590 590 MW-50-67 2/23/07 0858 2/26/07 1004 ND ND ND Q3938 590 MW-50-67 2/26/07 1004 2/28/07 1021 ND ND ND Q4164 590 MW-50-67 2/28/07 1021 3/2/07 0909 ND ND ND Q4182 590 MW-50-67 3/2/07 0909 3/5/07 1302 ND ND ND Q4552 590 MW-50-67 3/5/07 1302 3/7/07 1128 ND ND ND Q4739 590 MW-50-67 3/7/07 1128 3/9/07 0945 ND ND ND Q0794 610 MW-52A (21')
11/14/06 1405 11/20/06 1107 ND ND ND Q1026 610 MW-52A (21')
11/20/06 1107 11/27/06 0905 ND ND ND Q1251 610 MW-52A (21')
11/27/06 0965 12/4/06 1309 ND ND
_ND f:\\docs\\coa\\GZA.xls 3/19/2007 17
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak mn Conc. ppb Peak mn Conc. ppb Peak mn Conc. ppb Q2106 610 MW-52A (21')
1/15/07 1350 1/22/07 1300 ND ND ND Q0795 620 MW-52B (51')
11/14/06 1350 11/20/06 1112 ND ND ND Q1027 620 MW-52B (51')
11/20/06 1112 11/27/060911 ND ND ND Q1252 620 MW-52B (51')
11/27/06 0911 12/4/06 1310 ND ND
_ND Q2107 620 MW-52B (51')
1/15/07 1350 1/22/07 1302 ND ND ND Q1253 625 MW-52C (66')
11/30/06 1320 12/4/06 1311 ND ND ND Q2108 625 MW-52C (66')
1/15/07 1350 1/22/07 1305 ND ND ND Q1254 630 MW-52D (120')
11/30/06 1321 12/4/06 1312 ND ND ND Q2109 630 MW-52D (120')
1/15/07 1350 1/22/07 1308 ND ND ND Q1255 635 MW-52E (125')
11/30/06 1322 12/4/06 1314 ND ND ND Q2110 635 MW-52E (125')
1/15/07 1350 1/22/07 1310 ND ND ND Q0796 640 MW-52-12 11/14/06 1345 11/20/06 1115 ND ND ND Q1028 640 MW-52-12 11/20/06 1115 11/27/06 0901 ND ND ND Q1256 640 MW-52-12 11/27/06 0901 12/4/06 1315 ND ND ND Q2094 640 MW-52-12 1/15/07 1347 2/1/07 1124 ND ND ND Q2423 640 MW-52-12 2/1/07 1124 2/8/07 1554 ND ND ND Q2457 640 MW-52-12 2/8/07 1554 2/9/07 1132 ND ND ND Q2549 640 MW-52-12 2/9/07 1132 2/10/07 1526 ND ND ND Q2550 640 MW-52-12 2/10/07 1526 2/11/07 1408 ND ND ND Q2670 640 MW-52-12 2/11/07 1408 2/12/07 1501 ND ND ND Q2826 640 MW-52-12 2/12/07 1501 2/13/07 1415 ND ND ND Q2943 640 MW-52-12 2/13/07 1415 2/14/07 1405 ND ND ND Q3205 640 MW-52-12 2/14/07 1405 2/15/07 1422 ND ND ND Q3206 640 MW-52-12 2/15/07 1422 2/16/07 1303 ND ND ND Q3294 640 MW-52-12 2/16/07 1303 2/19/07 1400 ND ND ND Q3468 640 MW-52-12 2/19/07 1400 2/21/07 1400 ND ND ND Q3873 640 MW-52-12 2/21/07 1400 2/23/07 1050 ND ND ND Q3556 640 MW-52-12 2/23/07 1050 2/26/07 1353 ND ND ND Q3902 640 MW-52-12 2/26/07 1353 2/28/07 0916 ND ND IND Q4104 640 MW-52-12 2/28/07 0916 3/2/07 1443 ND ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 18
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc.ppb Peak mn Cone. ppb Peak un Conc. ppb Q4171 640 MW-52-12 3/2/07 1442 3/5/07 1355 ND ND ND Q4542 640 MW-52-12 3/5/07 1355 3/7/07 1410 ND ND ND Q4696 640 MW-52-12 3/7/07 1410 3/9/07 1500 ND ND ND Q0797 650 MW-53-82 11/15/06 1353 11/20/06 1336 ND ND ND Q1029 650 MW-53-82 11/20/06 1336 11/27/06 1149 ND ND ND Q1257 650 MW-53-82 11/27/06 1149 12/6/06 1118 ND ND ND Q2081 650 MW-53-80 1/16/07 0922 2/1/07 1420 ND 542.8 5.25 ND Q2478 650 MW-53-80 2/1/07 1420 2/8/07 1447 ND ND ND Q2409 650 MW-53-80 2/8/07 1447 2/9/07 1318 ND ND ND Q2562 650 MW-53-80 2/9/07 1318 2/10/07 1106 ND ND ND Q2525 650 MW-53-80 2/10/07 1106 2/11/07 1010 ND ND ND Q2646 650 MW-53-80 2/11/07 1010 2/12/07 1346 ND ND ND Q2861 650 MW-53-80 2/12/07 1346 2/13/07 1055 515.4 0.923 ND ND Q2918 650 MW-53-80 2/13/07 1055 2/14/07 1121 515.6 3.89 ND ND Q3239 650 MW-53-80 2/14/07 1121 2/16/07 1010 515.5 20.3 ND ND Q3306 650 MW-53-80 2/16/07 1010 2/19/07 1105 515.4 90.1 ND ND Q3503 650 MW53-80 2/19/07 1105 2/21/07 1155 515.3 85.3 ND ND Q3849 650 MW-53-80 2/21/07 1155 2/23/07 1145 515.5 66.1 ND ND Q3591 650 MW-53-80 2/23/07 1145 2/26/07 1329 515.3 162 ND ND Q3939 650 MW-53-80 2/26/07 1329 2/28/07 1420 515.3 71.0 ND ND Q4165 650 MW-53-80 2/28/07 1420 3/2/07 1311 515.1 45.4 ND ND Q4183 650 MW-53-80 3/2/07 1311 3/5/07 1328 515.1 2.73 ND ND Q4553 650 MW-53-80 3/5/07 1328 3/7/07 1518 515.3 4.60 ND ND Q4741 650 MW-53-80 3/7/07 1518 3/9/07 1118 515.8 2.43 ND ND Q0798 660 MW-53-120 11/15/06 1340 11/20/06 1325 ND ND ND Q1030 660 MW-53-120 11/20/06 1325 11/27/06 1140 ND ND IND Q1258 660 MW-53-120 11/27/06 1140 12/6/06 1057 ND ND ND Q2082 660 MW-53-120 1/16/07 0915 2/1/07 1425 ND ND ND Q2479 660 MW-53-120 2/1/07 1425 2/8/07 1450 ND I
ND ND Q2410 660 MW-53-120 2/8/07 1450 2/9/07 1320 ND I
ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 19
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak mn Conc. ppb Peak mu Conc. ppb Q2563 660 MW-53-120 2/9/07 1320 2/10/07 1109 ND ND ND Q2526 660 MW-53-120 2/10/07 1109 2/11/07 1011 ND ND ND Q2647 660 MW-53-120 2/11/07 1011 2/12/07 1349 ND ND ND Q2862 660 MW-53-120 2/12/07 1349 2/13/07 1058 ND ND ND Q2919 660 MW-53-120 2/13/07 1058 2/14/07 1123 ND ND ND Q3241 660 MW-53-120 2/14/07 1123 2/16/07 1015 ND ND ND Q3307 660 MW-53-120 2/16/07 1015 2/19/07 1110 ND ND ND Q3504 660 MW-53-120 2/19/07 1110 2/21/07 1159 ND ND ND Q3850 660 MW-53-120 2/21/07 1159 2/23/07 1149 ND ND ND Q3592 660 MW-53-120 2/23/07 1149 2/26/07 1333 ND ND ND Q3941 660 MW-53-120 2/26/07 1333 2/28/07 1427 ND ND ND Q4166 660 MW-53-120 2/28/07 1427 3/2/07 1317 ND ND ND Q4184 660 MW-53-120 3/2/07 1317 3/5/07 1332 ND ND ND Q4554 660 MW-53-120 3/5/07 1332 3/7/07 1523 ND ND ND Q4742 660 MW-53-120 3/7/07 1523 3/9/07 1122 ND ND ND Q0799 670 MW-54A (37')
11/15/06 0845 11/20/06 1335 ND ND ND Q1031 670 MW-54A (37')
11/20/06 1335 11/28/06 1002 ND ND ND Q1259 670 MW-54A (37')
11/28/06 1002 12/5/06 1148 ND ND ND Q2111 670 MW-54A (37')
1/22/07 1315 1/22/07 1015 ND ND ND Q0801 680 MW-54B (145')
11/15/06 0840 11/20/06 1330 ND ND ND Q1032 680 MW-54B (145')
11/20/06 1330 11/28/06 1004 ND ND ND Q1261 680 MW-54B (145')
11/28/06 1004 12/5/06 1150 ND ND ND Q2112 680 MW-54B (145')
1/22/07 1315 1/22/07 1017 ND ND ND Q0802 690 MW-54C (175')
11/15/06 0913 11/20/06 1320 ND ND ND Q1033 690 MW-54C (175')
11/20/06 1320 11/28/06 1006 ND ND ND Q1262 690 MW-54C (175')
11/28/06 1006 12/5/06 1151 ND ND ND Q2113 690 MW-54C (175')
1/22/07 1315 1/22/07 1017 ND ND ND Q1263 700 MW-54D (191')
11/28/06 1008 12/5/06 1152 ND ND ND Q2114 700 MW-54D (191')
1/22/07 1315 1/22/07 1018 ND ND ND Q0803 710 MW-55-24 11/14/06 1000 11/20/06 1045 514.6
- 6.953 ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 20
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak un Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q1034 710 MW-55-24 11/20/06 1045 11/27/06 0838 515.6 1.13 ND ND Q1264 710 MW-55-24 11/27/06 0838 12/5/06 1000 517.0
- 0.454 ND ND Q1931 710 MW-55-24 1/12/07 1424 1/24/07 1027 515.6
- 0.623 ND ND Q3276 710 MW-55-24 1/24/07 1027 2/13/07 1035 517.7
- 0.421 ND ND Q4091 710 MW-55-24 2/13/07 1035 3/1/07 0855 514.8 1.23 ND ND Q0804 720 MW-55-34 11/14/06 1013 11/20/06 1047 ND ND ND Q1035 720 MW-55-34 11/20/06 1047 11/27/06 0815 ND ND ND Q1265 720 MW-55-34 11/27/06 0815 12/5/06 0956 517.0
- 0.412 ND ND Q1932 720 MW-55-34 1/12/07 1418 1/24/07 1010 ND ND ND Q3277 720 MW-55-34 1/24/07 1010 2/13/07 1030 517.8
- 0.488 ND ND Q4092 720 MW-55-34 2/13/07 1030 3/1/07 0851 515.5 0.754 ND ND Q0805 730 MW-55-54 11/14/06 1022 11/20/06 1049 ND ND ND Q1036 730 MW-55-54 11/20/06 1049 11/27/06 0830 ND ND ND Q1266 730 MW-55-54 11/27/06 0830 12/5/06 0958 ND IND ND Q1933 730 MW-55-54 1/12/07 1423 1/24/07 1019 ND ND ND Q3278 730 MW-55-54 1/24/07 1019 2/13/07 1025 ND ND ND Q4093 730 MW-55-54 2/13/07 1025 3/1/07 0847 515.2 23.1 ND ND Q0806 740 MW-56A (55')
11/15/06 1416 11/20/06 1310 ND ND ND Q1037 740 MW-56A (55')
11/20/06 1310 11/27/06 1350 ND ND ND Q1934 740 MW-56-54 1/10/07 0957 1/24/07 1137 ND ND ND Q3279 740 MW 56-54 1/24/07 1137 2/15/07 0940 ND ND ND Q4094 740 MW-56-54 2/15/07 0940 3/1/07 1454 ND ND ND Q4131 740 MW-56-54 3/1/07 1454 3/2/07 1245 ND ND ND Q4235 740 MW-56-54 3/2/07 1245 3/5/07 1404 ND ND ND Q4608 740 MW-56-54) 3/5/07 1404 3/7/07 0906 ND ND ND Q4723 740 MW-56-54 3/7/07 0906 3/9/07 1048 ND ND ND Q0807 750 MW-56B (75')
11/15/06 1422 11/20/06 1302 ND ND IND Q1038 750 MW-56B (75')
11/20/06 1302 11/27/06 1355 ND ND ND Q1267 750 MW-56B (75')
11/27/06 1355 12/5/06 0842 ND ND IND Q1935 750 MW-56-85 1/10/07 1012 1/24/07 1132 ND ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 21
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Cone. ppb Peak am Conc. ppb Peak nm Conc. ppb Q3281 750 MW-56-85 1/24/07 1132 2/15/07 0945 ND ND
_ND Q4095 750 MW-56-85 2/15/07 0945 3/1/07 1500 ND ND ND Q4132 750 MW-56-85 3/1/07 1500 3/2/07 1249 ND ND ND Q4236 750 MW-56-85 3/2/07 1249 3/5/07 1410 ND ND ND Q4609 750 MW-56-85 3/5/07 1410 3/7/07 0910 ND ND ND Q4724 750 MW-56-85 3/7/07 0910 3/9/07 1051 ND ND ND Q0808 770 MW-57-11 11/15/06 0755 11/20/06 1306 ND ND ND Q1039 770 MW-57-11 11/20/06 1306 11/27/06 1124 ND ND ND Q1268 770 MW-57-11 11/27/06 1124 12/4/06 1046 ND ND ND Q2054 770 MW-57-11 1/15/07 1204 2/1/07 1006 ND ND ND Q2443 770 MW-57-11 2/1/07 1006 2/8/07 1500 ND ND ND Q2384 770 MW-57-11 2/8/07 1500 2/9/07 1405 ND ND ND Q2499 770 MW-57-11 2/9/07 1405 2/10/07 1118 ND ND ND Q2594 770 MW-57-11 2/10/07 1118 2/11/07 1530 ND ND ND Q2621 770 MW-57-11 2/11/07 1330 2/12/07 1050 ND ND ND Q2835 770 MW-57-11 2/12/07 1050 2/13/07 1310 ND ND ND Q2893 770 MW-57-11 2/13/07 1310 2/14/07 1040 ND ND ND Q3215 770 MW-57-11 2/14/07 1040 2/16/07 1038 ND ND ND Q3338 770 MW-57-11 2/16/07 1038 2/19/07 1056 ND ND ND Q3477 770 MW-57-11 2/19/07 1056 2/21/07 1034 ND ND ND Q3824 770 MW-57-11 2/21/07 1034 2/23/07 1009 ND ND ND Q3566 770 MW-57-11 2/23/07 1009 2/26/07 1040 515.5 7.20 ND ND Q3911 770 MW-57-11 2/26/07 1040 2/28/07 1358 515.2 12.6 ND ND Q4113 770 MW-57-11 2/28/07 1358 3/2/07 0847 515.3 19.8 ND ND Q4217 770 MW-57-11 3/2/07 0847 3/5/07 1041 515.3 16.7 ND ND Q4588 770 MW-57-11 3/5/07 1041 3/7/07 1413 ND ND ND Q4706 770 MW-57-11 3/7/07 1413 3/9/07 0912 515.1 17.2 ND ND Q0809 780 MW-57-20 11/15/06 0805 11/20/06 1307 ND ND ND Q1041 780 MW-57-20 11/20/06 1307 11/27/06 1127 ND ND ND Q1269 780 MW-57-20 11/27/06 1127 12/4/06 1041 ND ND IND I
f:\\docs\\coa\\GZA.xls 3/19/2007 22
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak mn Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q2055 780 MW-57-20 1/15/07. 1.155 2/1/07 1002 ND ND ND Q2444 780 MW-57-20 2/1/07 1002 2/8/07 1455 ND ND ND Q2385 780 MW-57-20 2/8/07 1455 2/9/07 1408 ND ND ND Q2501 780 MW-57-20 2/9/07 1408 2/10/07 1114 ND ND ND Q2595 780 MW-57-20 2/10/07 1114 2/11/07 1050 ND ND ND Q2622 780 MW-57-20 2/11/07 1050 2/12/07 1045 ND ND ND Q2836 780 MW-57-20 2/12/07 1045 2/13/07 1305 ND ND ND Q2894 780 MW-57-20 2/13/07 1305 2/14/07 1035 ND ND ND Q3216 780 MW-57-20 2/14/07 1035 2/16/07 1035 ND ND ND Q3339 780 MW-57-20 2/16/07 1035 2/19/07 1053 ND ND ND Q3478 780 MW-57-20 2/19/07 1053 2/21/07 1030 ND ND IND Q3825 780 MW-57-20 2/21/07 1030 2/23/07 1005 ND ND ND Q3567 780 MW-57-20 2/23/07 1005 2/26/07 1036 ND ND ND Q3912 780 MW-57-20 2/26/07 1036 2/28/07 1402 ND ND ND Q4114 780 MW-57-20 2/28/07 1402 3/2/07 0844 ND ND ND Q4218 780 MW-57-20 3/2/07 0844 3/5/07 1038 ND ND ND Q4589 780 MW-57-20 3/5/07 1038 3/7/07 1411 515.3 28.8 ND ND Q4707 780 MW-57-20 3/7/07 1411 3/9/07 0909 ND ND ND Q0810 790 MW-57-45 11/15/06 0813 11/20/06 1305 ND ND ND Q1042 790 MW-57-45 11/20/06 1305 11/27/06 1120 ND ND ND Q1270 790 MW-57-45 11/27/06 1120 12/4/06 1038 ND ND ND Q2056 790 MW-57-45 1/15/07 1159 2/1/07 0958 ND ND ND Q2445 790 MW-57-45 2/1/07 0958 2/8/07 1450 ND ND ND Q2386 790 MW-57-45 2/8/07 1450 2/9/07 1412 ND ND ND Q2502 790 MW-57-45 2/9/07 1412 2/10/07 1110 ND ND ND Q2596 790 MW-57-45 2/10/07 1110 2/11/07 1043 ND ND ND Q2623 790 MW-57-45 2/11/07 1043 2/12/07 1040 ND ND ND Q2837 790 MW-57-45 2/12/07 1040 2/13/07 1300 ND ND ND Q2895 790 MW-57-45 2/13/07 1300 2/14/07 1030 ND ND ND Q3217 790 MW-57-45 2/14/07 1030 2/16/07 1030 ND ND IND I
f:\\docs\\coa\\GZA.xls 3/19/2007 23
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak am Conc. ppb Peak un Conc. ppb Peak un Conc. ppb Q3341 790 MW-57-45 2/16/07 1030 2/19/07 1047 ND ND ND Q3479 790 MW-57-45 2/19/07 1047 2/21/07 1025 ND ND ND Q3826 790 MW-57-45 2/21/07 1025 2/23/07 1002 ND ND ND Q3568 790 MW-57-45 2/23/07 1002 2/26/07 1032 ND ND ND Q3913 790 MW-57-45 2/26/07 1032 2/28/07 1407 ND ND ND Q4115 790 MW-57-45 2/28/07 1407 3/2/07 0840 ND ND ND Q4219 790 MW-57-45 3/2/07 0840 3/5/07 1034 ND ND ND Q4590 790 MW-57-45 3/5/07 1034 3/7/07 1407 ND ND ND Q4708 790 MW-57-45 3/7/07 1407 3/9/07 0906 ND ND IND Q1271 800 MW-58-26 11/29/06 1336 12/5/06 1316 515.2
- 1.09 ND ND Q2057 800 MW-58-26 1/16/07 0950 2/1/07 1019 515.7
- 2.42 ND ND Q2446 800 MW-58-26 2/1/071019 2/8/07 1435 516.0
- 1.11 ND ND Q2387 800 MW-58-26 2/8/07 1435 2/9/07 1350 ND ND ND Q2597 800 MW-58-26 2/10/07 1053 2/11/07 1025 ND ND ND Q2610 800 MW-58-26 2/9/07 1350 2/11/07 1434 ND ND ND Q2624 800 MW-58-26 2/11/07 1025 2/12/07 1020 ND ND ND Q2838 800 MW-58-26 2/12/07 1020 2/13/07 1115 ND ND ND Q2896 800 MW-58-26 2/13/07 1115 2/14/07 1010 ND ND ND Q3218 800 MW-58-26 2/14/07 1010 2/16/07 0945 ND ND ND Q3342 800 MW-58-26 2/16/07 0945 2/19/07 1105 ND ND ND Q3481 800 MW-58-26 2/19/07 1105 2/21/07 1042 ND ND ND Q3827 800 MW-58-26 2/21/07 1042 2/23/07 0942 ND ND ND Q3569 800 MW-58-26 2/23/07 0942 2/26/07 0855 ND ND ND Q3914 800 MW-58-26 2/26/07 0855 2/28/07 1335 ND ND ND Q4116 800 MW-58-26 2/28/07 1335 3/2/07 1308 ND ND ND Q4221 800 MW-58-26 3/2/07 1308 3/5/07 1046 515.9
- 1.39 ND ND Q4591 800 MW-58-26 3/5/07 1046 3/7/07 1333 516.3 0.933 ND ND Q4709 800 MW-58-26 3/7/07 1333 3/9/07 0920 516.1
- 1.09 ND ND Q1272 810 MW-58-65 11/29/06 1342 12/5/06 1314 ND ND I
ND Q2058 810 MW-58-65 1/16/07 0945 2/1/07 1021 517.2 1.31 ND I
ND I
f:\\docs\\coa\\GZA.xls 3/19/2007 24
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak mn Conc. ppb Peak nm Conc. ppb Peak nm Cone. ppb Q2447 810 MW-58-65 2/1/07 1021 2/8/07 1440 517.2
- 0.913 ND ND Q2388 810 MW-58-65 2/8/07 1440 2/9/07 1355 ND ND ND Q2503 810 MW-58-65 2/9/07 1355 2/10/07 1057 ND ND ND Q2598 810 MW-58-65 2/10/07 1057 2/11/07 1030 ND ND ND Q2625 810 MW-58-65 2/11/07 1030 2/12/07 1025 ND ND ND Q2839 810 MW-58-65 2/12/07 1025 2/13/07 1120 ND ND ND Q2897 810 MW-58-65 2/13/07 1120 2/14/07 1015 ND ND ND Q3219 810 MW-58-65 2/14/07 1015 2/16/07 0950 517.8*
0.401 ND ND Q3343 810 MW-58-65 2/16/07 0950 2/19/07 1110 ND ND ND Q3482 810 MW-58-65 2/19/07 1110 2/21/07 1046 ND ND ND Q3828 810 MW-58-65 2/21/07 1046 2/23/07 0947 ND ND ND Q3570 810 MW-58-65 2/23/07 0947 2/26/07 0900 ND ND ND Q3915 810 MW-58-65 2/26/07 0900 2/28/07 1340 ND ND ND Q4117 810 MW-58-65 2/28/07 1340 3/2/07 1313 ND ND ND Q4222 810 MW-58-65 3/2/07 1313 3/5/07 1050 515.6
- 0.824 ND ND Q4592 810 MW-58-65 3/5/07 1050 3/7/07 1338 516.4
- 0.849 ND ND Q4710 810 MW-58-65 3/7/07 1338 3/9/07 0925 ND ND ND Q1273 830 MW-59-31 11/29/06 1257 12/5/06 1339 516.2
- 0.474 ND ND Q2083 830 MW-59-31 1/16/07 1008 2/1/07 1321 519.8
- 0.497 ND ND Q2481 830 MW-59-31 2/1/07 1321 2/8/07 1420 515.0
- 0.942 ND ND Q2411 830 MW-59-31 2/8/07 1420 2/9/07 1134 ND ND ND Q2564 830 MW-59-31 2/9/07 1134 2/10/07 1046 ND ND ND Q2527 830 MW-59-31 2/10/07 1046 2/11/07 0745 ND ND ND Q2648 830 MW-59-31 2/11/07 0745 2/12/07 1326 ND ND ND Q2863 830 MW-59-31 2/12/07 1326 2/13/07 1034 ND ND ND Q2921 830 MW-59-31 2/13/07 1034 2/14/07 1055 ND ND ND Q3242 830 MW-59-31 2/14/07 1055 2/16/07 0910 ND ND ND Q3308 830 MW-59-31 2/16/07 0910 2/19/07 1045 ND ND IND I
Q3505 830 MW-59-31 2/19/07 1045 2/21/07 1129 ND ND ND Q3851 830 MW-59-31 2/21/07 1129 2/23/07 1044 ND ND
_ND f:\\docs\\coa\\GZA.xls 3/19/2007 25
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak un Conc. ppb Q3593 830 MW-59-31 2/23/07 1044 2/26/07 1146 ND ND ND Q3942 830 MW-59-31 2/26/07 1146 2/28/07 1342 ND ND ND Q4167 830 MW-59-31 2/28/07 1342 3/2/07 1117 ND ND ND Q4185 830 MW-59-31 3/2/07 1117 3/5/07 1116 ND ND ND Q4555 830 MW-59-31 3/5/07 1116 3/7/07 1426 ND ND ND Q4743 830 MW-59-31 3/7/07 1426 3/9/07 1006 ND ND ND Q1274 840 MW-59-45 11/29/06 1311 12/5/06 1346 ND ND ND Q2084 840 MW-59-45 1/16/07 1004 2/1/07 1339 514.2
- 0.770 ND ND Q2482 840 MW-59-45 2/1/07 1339 2/8/07 1428 ND ND ND Q2412 840 MW-59-45 2/8/07 1428 2/9/07 1136 ND ND ND Q2565 840 MW-59-45 2/9/07 1136 2/10/07 1050 ND ND ND Q2528 840 MW-59-45 2/10/07 1050 2/11/07 0748 ND ND ND Q2649 840 MW-59-45 2/11/07 0748 2/12/07 1329 ND ND ND Q2864 840 MW-59-45 2/12/07 1329 2/13/07 1037 ND ND IND Q2922 840 MW-59-45 2/13/07 1037 2/14/07 1050 ND ND ND Q3243 840 MW-59-45 2/14/07 1059 2/16/07 0921 ND ND ND Q3309 840 MW-59-45 2/16/07 0921 2/19/07 1047 ND ND ND Q3506 840 MW-59-45 2/19/07 1047 2/21/07 1136 ND ND ND Q3852 840 MW-59-45 2/21/07 1136 2/23/07 1049 ND ND ND Q3594 840 MW-59-45 2/23/07 1049 2/26/07 1151 ND ND ND Q3943 840 MW-59-45 2/26/07 1151 2/28/07 1349 ND ND ND Q4168 840 MW-59-45 2/28/07 1340 3/2/07 1120 ND ND ND Q4186 840 MW-59-45 3/2/07 1120 3/5/07 1124-ND ND ND Q4556 840 MW-59-45 3/5/07 1124 3/7/07 1433 ND ND ND Q4744 840 MW-59-45 3/7/07 1433 3/9/07 1010 ND ND ND Q0811 850 MW-60A (37')
11/14/06 1320 11/20/06 0816 ND ND ND Q1043 850 MW-60A (37')
11/20/06 0816 11/27/06 0906 ND ND ND Q1936 850 MW-60A (37')
1/12/07 1105 1/17/07 1020 ND ND ND Q2059 850 MW-60A (37')
1/17/07 1020 2/1/07 1037 ND ND ND Q2448 850 MW-60A (37')
2/1/07 1037 2/8/07 0900 ND ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 26
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak am Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q2389 850 MW-60A (37')
2/8/07 0900 2/9/07 1005 ND ND ND Q2504 850 MW-60A (37')
2/9/07 1005 2/10/07 0810 ND ND ND Q2599 850 MW-60A (37')
2/10/07 0810 2/11/07 0745 ND ND ND Q2626 850 MW-60A (37')
2/11/07 0745 2/12/07 0810 ND ND ND Q2841 850 MW-60A (37')
2/12/07 0840 2/13/07 0825 ND ND ND Q2898 850 MW-60A (37')
2/13/07 0825 2/14/07 0945 ND ND ND Q3221 850 MW-60A (37')
2/14/07 0945 2/16/07 1015 ND ND ND Q3344 850 MW-60A (37')
2/16/07 1015 2/19/07 0845 ND ND ND Q3483 850 MW-60A (37')
2/19/07 0845 2/21/07 1105 ND ND ND Q3829 850 MW-60A (37')
2/21/07 1105 2/23/07 1025 ND ND ND Q3571 850 MW-60A (37')
2/23/07 1025 2/26/07 0930 ND ND ND Q3916 850 MW-60A (37')
2/26/07 0930 2/28/07 1115 ND ND ND Q4118 850 MW-60A (37')
2/28/07 1115 3/2/07 1405 ND ND ND Q4223 850 MW-60A (37')
3/2/07 1405 3/5/07 0940 ND ND ND Q4593 850 MW-60A (37')
3/5/07 0940 3/7/07 1125 ND ND ND Q4711 850 MW-60A (37')
3/7/07 1125 3/9/07 0843 ND ND ND Q0812 860 MW-60B (55')
11/14/06 1340 11/20/06 0820 ND ND ND Q1044 860 MW-60B (55')
11/20/06 0820 11/27/06 0911 ND ND ND Q1937 860 MW-60B (55')
1/12/07 1105 1/17/07 1020 ND ND ND Q2061 860 MW-60B (55')
1/17/07 1020 2/1/07 1037 ND ND ND Q2449 860 MW-60B (55')
2/1/07 1037 2/8/07 0900 ND ND ND Q2390 860 MW-60B (55')
2/8/07 0900 2/9/07 1005 ND ND ND Q2505 860 MW-60B (55')
2/9/07 1005 2/10/07 0810 ND ND ND Q2601 860 MW-60B (55')
2/10/07 0810 2/11/07 0745 ND ND ND Q2627 860 MW-60B (55')
2/11/07 0745 2/12/07 0840 ND ND ND Q2842 860 MW-60B (55')
2/12/07 0840 2/13/07 0825 ND ND ND Q2899 860 MW-60B (55')
2/13/07 0825 2/14/07 0945 ND ND ND Q3222 860 MW-60B (55')
2/14/07 0945 2/16/07 1015 ND ND ND Q3345 860 MW-60B (55')
2/16/07 1015 2/19/07 0845 ND ND ND Q3484 860 MW-60B (55')
2/19/07 0845 2/21/07 1105 ND ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 27
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak mu Conc. ppb Q3830 860 MW-60B (55')
2/21/07 1105 2/23/07 1025 ND ND ND Q3572 860 MW-60B (55')
2/23/07 1025 2/26/07 0930 ND ND ND Q3917 860 MW-60B (55')
2/26/07 0930 2/28/07 1115 ND ND IND Q4119 860 MW-60B (55')
2/28/07 1115 3/2/07 1405 ND ND ND Q4224 860 MW-60B (55')
3/2/07 1405 3/5/07 0940 ND ND ND Q4594 860 MW-60B (55')
3/5/07 0940 3/7/07 1125 ND ND ND Q4712 860 MW-60B (55')
3/7/07 1125 3/9/07 0843 ND ND ND Q1938 870 MW-60C (75')
1/12/07 1105 1/17/07 1020 ND ND ND Q2062 870 MW-60C (75')
1/17/07 1020 2/1/07 1037 ND ND ND Q2450 870 MW-60C (75')
2/1/07 1037 2/8/07 0900 ND ND ND Q2391 870 MW-60C (75')
2/8/07 0900 2/9/07 1005 ND ND ND Q2506 870 MW-60C (75')
2/9/07 1005 2/10/07 0810 ND ND ND Q2602 870 MW-60C (75')
2/10/07 0810 2/11/07 0745 ND
__ND ND Q2628 870 MW-60C (75')
2/11/07 0745 2/12/07 0840 ND ND ND Q2944 870 MW-60C (75')
2/12/07 0840 2/13/07 0825 ND ND ND Q2901 870 MW-60C (75')
2/13/07 0825 2/14/07 0943 ND ND ND Q3223 870 MW-60C (75')
2/14/07 0945 2/16/07 1015 ND ND ND Q3346 870 MW-60C (75')
2/16/07 1015 2/19/07 0845 ND ND IND Q3485 870 MW-60C (75')
2/19/07 0845 2/21/07 1105 ND ND ND Q3831 870 MW-60C (75')
2/21/07 1105 2/23/07 1025 ND ND ND Q3573 870 MW-60C (75')
2/23/07 1025 2/26/07 0930 ND ND ND Q3918 870 MW-60C (75')
2/26/07 0930 2/28/07 1115 ND ND ND Q4121 870 MW-60C (75')
2/28/07 1115 3/2/07 1405 ND ND ND Q4225 870 MW-60C (75')
3/2/07 1405 3/5/07 0940 ND ND ND Q4597 870 MW-60C (75')
3/5/07 0940 3/7/07 1125 ND ND ND Q4713 870 MW-60C (75')
3/7/07 1125 3/9/07 0843 ND ND ND Q1939 880 MW-60D (136')
1/12/07 1105 1/17/07 1020 ND ND ND Q2063 880 MW-60D (136')
1/17/07 1020 2/1/07 1037 ND ND ND Q2451 880 MW-60D (136')
2/1/07 1037 2/8/07 0900 ND ND ND Q2392 880 MW-60D (136')
2/8/07 0900 2/9/07 1005 ND ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 28
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak mu Conc. ppb Q2507 880 MW-60D (136')
2/9/07 1005 2/10/07 0810 ND ND ND Q2603 880 MW-60D (136')
2/10/07 0810 2/11/07 0745 ND ND ND Q2629 880 MW-60D (136')
2/11/07 0745 2/12/07 0840 ND ND ND Q2843 880 MW-60D (136')
2/12/07 0840 2/13/07 0825 ND ND ND Q2902 880 MW-60D (136')
2/13/07 0825 2/14/07 0945 ND ND ND Q3224 880 MW-60D (136')
2/14/07 0945 2/16/07 1015 ND ND ND Q3347 880 MW-60D (136')
2/16/07 1015 2/19/07 0845 ND ND ND Q3486 880 MW-60D (136')
2/19/07 0845 2/21/07 1105 ND ND ND Q3832 880 MW-60D (136')
2/21/07 1105 2/23/07 1025 ND ND ND Q3574 880 MW-60D (136')
2/23/07 1025 2/26/07 0930 ND ND ND Q3919 880 MW-60D (136')
2/26/07 0930 2/28/07 1115 ND ND ND Q4122 880 MW-60D (136')
2/28/07 1115 3/2/07 1405 ND ND ND Q4226 880 MW-60D (136')
3/2/07 1405 3/5/07 0940 ND ND ND Q4598 880 MW-60D (136')
3/5/07 0940 3/7/07 1125 ND ND ND Q4714 880 MW-60D (136')
3/7/07 1125 3/9/07 0843 ND ND ND Q1941 890 MW-60E (175')
1/12/07 1105 1/17/07 1020 ND ND ND Q2064 890 MW-60E (175')
1/17/07 1020 2/1/07 1037 ND ND ND Q2452 890 MW-60E (175')
2/1/07 1037 2/8/07 0900 ND ND ND Q2393 890 MW-60E (175')
2/8/07 0900 2/9/07 1005 ND ND IND Q2508 890 MW-60E (175')
2/9/07 1005 2/10/07 0810 ND ND IND Q2604 890 MW-60E (175')
2/10/07 0810 2/11/07 0745 ND ND ND Q2630 890 MW-60E (175')
2/11/07 0745 2/12/07 0840 ND ND ND Q2844 890 MW-60E (175')
2/12/07 0840 2/13/07 0825 ND ND ND Q2903 890 MW-60E (175')
2/13/07 0825 2/14/07 0945 ND ND ND Q3225 890 MW-60E (175')
2/14/07 0945 2/16/07 1015 ND ND ND Q3348 890 MW-60E (175')
2/16/07 1015 2/19/07 0845 ND ND ND Q3487 890 MW-60E (175')
2/19/07 0845 2/21/07 1105 ND ND ND Q3833 890 MW-60E (175')
2/21/07 1105 2/23/07 1025 ND ND IND Q3575 890 MW-60E (175')
2/23/07 1025 2/26/07 0930 ND ND IND Q3921 890 MW-60E (175')
2/26/07 0930 2/28/07 1115 ND ND IND 29 f:\\docs\\coa\\GZA.xls 3/19/2007
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Cone. ppb Peak nm Cone. ppb Peak nm Conc. ppb Q4123 890 MW-60E (175')
2/28/07 1115 3/2/07 1405 ND ND ND Q4227 890 MW-60E (175')
3/2/07 1405 3/5/07 0940 ND ND ND Q4599 890 MW-60E (175')
3/5/07 0940 3/7/07 1125 ND ND ND Q4715 890 MW-60E (175')
3/7/07 1125 3/9/07 0843 ND ND ND Q1275 900 MW-59-68 11/29/06 1319 12/5/06 1333 ND ND ND Q2085 900 MW-59-68 1/16/07 0958 2/1/07 1357 517.4
- 0.655 ND ND Q2483 900 MW-59-68 2/1/07 1357 2/8/07 1432 518.2
- 0.530 ND ND Q2413 900 MW-59-68 2/8/07 1432 2/9/07 1142 ND ND ND Q2566 900 MW-59-68 2/9/07 1142 2/10/07 1051 ND ND ND Q2529 900 MW-59-68 2/10/07 1051 2/11/07 0751 ND ND ND Q2650 900 MW-59-68 2/11/07 0751 2/12/07 1332 ND ND ND Q2865 900 MW-59-68 2/12/07 1332 2/13/07 1038 ND ND ND Q2923 900 MW-59-68 2/13/07 1038 2/14/07 1100 ND ND ND Q3244 900 MW-59-68 2/14/07 1100 2/16/07 0925 ND ND ND Q3310 900 MW-59-68 2/16/07 0925 2/19/07 1050 ND ND ND Q3507 900 MW-59-68 2/19/07 1050 2/21/07 1140 ND ND ND Q3853 900 MW-59-68 2/21/07 1140 2/23/07 1056 ND ND ND Q3595 900 MW-59-68 2/23/07 1056 2/26/07 1157 ND ND ND Q3944 900 MW-59-68 2/26/07 1157 2/28/07 1555 ND ND ND Q4169 900 MW-59-68 2/28/07 1355 3/2/07 1130 ND ND ND Q4187 900 MW-59-68 3/2/07 1130 3/5/07 1130 ND ND ND Q4557 900 MW-59-68 3/5/07 1130 3/7/07 1440 ND ND ND Q4745 900 MW-59-68 3/7/07 1440 3/9/07 1016 ND ND ND Q2102 910 MW-66A (50')
1/22/07 1345 2/1/07 0940 ND ND ND Q2430 910 MW-66A (50')
2/1/07 1016 2/8/07 1325 ND ND IND Q2465 910 MW-66A (50')
2/8/07 1325 2/9/07 0945 ND ND IND Q2582 910 MW-66A (50')
2/9/07 1325 2/10/07 0755 ND ND ND Q2545 910 MW-66A (50')
2/10/07 0755 2/11/07 0803 ND ND ND Q2666 910 MW-66A (50')
2/11/07 0803 2/12/07 0937 ND ND ND Q2881 910 MW-66A (50')
2/12/07 0937 2/13/07 0940 ND ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 30
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q2938 910 MW-66A (50')
2/13/07 0940 2/14/07 0947 ND ND ND Q3259 910 MW-66A (50')
2/14/07 0947 2/16/07 1315 ND ND ND Q3326 910 MW-66A (50')
2/16/07 1315 2/19/07 0843 ND ND ND Q3523 910 MW-66A (50')
2/19/07 0843 2/21/07 0802 ND ND ND Q3869 910 MW-66A (50')
2/21/07 0802 2/23/07 0913 ND ND ND Q3611 910 MW-66A (50')
2/23/07 0913 2/26/07 1020 ND ND ND Q3959 910 MW-66A (50')
2/26/07 1020 2/28/07 1041 516.0 4.07 ND ND Q4148 910 MW-66A (50')
2/28/07 1041 3/2/07 1023 ND ND ND Q4203 910 MW-66A (50')
3/2/07 1023 3/5/07 0827 ND ND ND Q4573 910 MW-66A (50')
3/5/07 0827 3/7/07 0959 ND ND ND Q4754 910 MW-66A (50')
3/7/07 0959 3/9/07 0742 ND ND ND Q2103 920 MW-66B (115')
1/22/07 1345 2/1/07 0940 ND ND ND Q2431 920 MW-66B (115')
2/1/07 0940 2/8/07 1325 ND ND ND Q2466 920 MW-66B (115')
2/8/07 1325 2/9/07 0947 ND ND ND Q2583 920 MW-66B (115')
2/9/07 1325 2/10/07 0755 ND ND ND Q2546 920 MW-66B (115')
2/10/07 0755 2/11/07 0803 ND ND ND Q2667 920 MW-66B (115')
2/11/07 0803 2/12/07 0937 ND ND ND Q2882 920 MW-66B (115')
2/12/07 0937 2/13/07 0940 ND ND ND Q2939 920 MW-66B (115')
2/13/07 0940 2/14/07 0947 ND ND ND Q3261 920 MW-66B (115')
2/14/07 0947 2/16/07 1315 ND ND ND Q3327 920 MW-66B (115')
2/16/07 1315 2/19/07 0843 ND ND ND Q3524 920 MW-66B (115')
2/19/07 0843 2/21/07 0802 ND ND ND Q3870 920 MW-66B (115')
2/21/07 0802 2/23/07 0913 ND ND ND Q3612 920 MW-66B (115')
2/23/07 0913 2/26/07 1020 ND ND ND Q3961 920 MW-66B (115')
2/26/07 1020 2/28/07 1041 517.9
- 1.07 ND ND Q4149 920 MW-66B (115')
2/28/07 1041 3/2/07 1023 ND ND ND Q4204 920 MW-66B (115')
3/2/07 1023 3/5/07 0827 ND ND ND Q4574 920 MW-66B (115')
3/5/07 0827 3/7/07 0959 ND ND ND Q4755 920 MW-66B (115')
3/7/07 0959 3/9/07 0742 ND ND ND Q2104 930 MW-66C (135')
1/22/07 1345 2/1/070940 ND ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 31
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q2432 930 MW-66C (135')
2/1/07 0940 2/8/07 1325 ND ND ND Q2467 930 MW-66C (135')
2/8/07 1325 2/9/07 0949 ND ND ND Q2584 930 MW-66C (135')
2/9/07 1325 2/10/07 0755 ND ND ND Q2547 930 MW-66C (135')
2/10/07 0755 2/11/07 0803 ND ND ND Q2668 930 MW-66C (135')
2/11/07 0803 2/12/07 0937 ND ND ND Q2883 930 MW-66C (135')
2/12/07 0937 2/13/07 0940 ND ND ND Q2941 930 MW-66C (135')
2/13/07 0940 2/14/07 0947 ND ND ND Q3262 930 MW-66C (135')
2/14/07 0947 2/16/07 1315 ND ND ND Q3328 930 MW-66C (135')
2/16/07 1315 2/19/07 0843 ND ND ND Q3525 930 MW-66C (135')
2/19/07 0843 2/21/07 0802 ND ND ND Q3871 930 MW-66C (135')
2/21/07 0802 2/23/07 0913 ND ND ND Q3613 930 MW-66C (135')
2/23/07 0913 2/26/07 1020 ND ND ND Q3962 930 MW-66C (135')
2/26/07 1020 2/28/07 1041 ND ND ND Q4150 930 MW-66C (135')
2/28/07 1041 3/2/07 1023 ND ND ND Q4205 930 MW-66C (135')
3/2/07 1023 3/5/07 0827 ND ND ND Q4575 930 MW-66C (135')
3/5/07 0827 3/7/07 0959 ND ND ND Q4756 930 MW-66C (135')
3/7/07 0959 3/9/07 0742 ND ND ND Q2105 940 MW-66D (190')
1/23/07 0845 2/1/07 0940 ND ND IND Q2433 940 MW-66D (190')
2/1/07 0940 2/8/07 1325 ND ND ND Q2468 940 MW-66D (190')
2/8/07 1325 2/9/07 0950 ND ND ND Q2585 940 MW-66D (190')
2/9/07 1325 2/10/07 0755 ND ND ND Q2548 940 MW-66D (190) 2/10/07 0755 2/11/07 0803 ND ND ND Q2669 940 MW-66D (190')
2/11/07 0803 2/12/07 0937 ND ND ND Q2884 940 MW-66D (190')
2/12/07 0937 2/13/07 0940 ND ND ND Q2942 940 MW-66D(190')
2/13/07 0940 2/14/07 0947 ND ND ND Q3263 940 MW-66D (190')
2/14/07 0947 2/16/07 1315 ND ND ND Q3329 940 MW-66D (190')
2/16/07 1315 2/19/07 0843 ND ND ND Q3526 940 MW-66D (190')
2/19/07 0843 2/21/07 0802 ND ND ND Q3872 940 MW-66D (190')
2/21/07 0802 2/23/07 0913 ND ND ND Q3614 940 MW-66D (190')
2/23/07 0913 2/26/07 1020 ND ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 32
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q3963 940 MW-66D (190')
2/26/07 1020 2/28/07 1041 ND ND ND Q4151 940 MW-66D (190')
2/28/07 1041 3/2/07 1023 ND ND ND Q4206 940 MW-66D (190')
3/2/07 1023 3/5/07 0827 ND ND ND Q4576 940 MW-66D (190')
3/5/07 0827 3/7/07 0959 ND ND ND Q4757 940 MW-66D (190')
3/7/07 0959 3/9/07 0742 ND ND ND Q2066 950 1-2 1/16/07 0800 2/1/07 1418 ND ND ND Q2454 950 1-2 2/1/07 1418 2/8/07 0825 ND ND ND Q2395 950 1-2 2/8/07 0825 2/9/07 0839 ND ND ND Q25.10 950 1-2 2/9/07 0839 2/10/07 0745 ND ND ND Q2606 950 1-2 2/10/07 0745 2/11/07 0723 ND
_ND ND Q2632 950 1-2 2/11/07 0723 2/12/07 0825 ND ND ND Q2846 950 1-2 2/12/07 0825 2/13/07 0800 ND ND ND Q2905 950 1-2 2/13/07 0800 2/14/07 0800 ND ND ND Q3227 950 1-2 2/14/07 0800 2/16/07 0750 ND ND ND Q3350 950 1-2 2/16/07 0750 2/19/07 0745 ND ND ND Q3489 950 1-2 2/19/07 0745 2/21/07 0804 ND ND ND Q3835 950 1-2 2/21/07 0804 2/23/07 0755 ND ND ND Q3577 950 1-2 2/23/07 0755 2/26/07 1100 ND ND ND Q3923 950 1-2 2/26/07 1100 2/28/07 0830 ND ND ND Q4125 950 1-2 2/28/07 0830 3/2/07 1100 ND ND ND Q4229 950 1-2 3/2/07 1100 3/5/07 1420 ND ND ND Q4602 950 1-2 3/5/07 1420 3/7/07 0840 ND ND ND Q4717 950 1-2 3/7/07 0840 3/9/07 0733 ND ND ND Q2067 960 U2-C1 1/15/07 1247 2/1/07 1345 515.8
- 0.512 ND ND Q2455 960 U2-C1 2/1/07 1345 2/8/07 1033 515.2
- 0.571 ND ND Q2396 960 U2-C1 2/8/07 1033 2/9/07 1128 ND ND ND Q2511 960 U2-C1 2/9/07 1128 2/10/07 0927 ND ND ND Q2607 960 U2-C1 2/10/07 0927 2/11/07 0905 ND ND ND Q2633 960 U2-C1 2/11/07 0905 2/12/07 0953 ND ND ND Q2847 960 U2-C1 2/12/07 0953 2/13/07 1454 ND
_ND
_ND f:\\docs\\coa\\GZA.xls 3/19/2007 33
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Cone. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q2906 960 U2-C1 2/13/07 1454 2/14/07 1105 ND ND ND Q3228 960 U2-C1 2/14/07 1105 2/16/07 1050 515.2
- 0.349 ND ND Q3228D 960 U2-C1 2/14/07 1105 2/16/07 1050 517.2
- 0.324 ND ND Q3351 960 U2-C1 2/16/07 1050 2/19/07 1000 516.9
- 0.393 ND ND Q3351D 960 U2-C1 2/16/07 1050 2/19/07 1000 ND ND IND Q3490 960 U2-C1 2/19/07 1000 2/21/07 0905 516.2
- 0.465 ND ND Q3836 960 U2-C1 2/21/07 0905 2/23/07 0848 ND ND ND Q3578 960 U2-C1 2/23/07 0848 2/26/07 1023 ND ND ND Q3578D 960 U2-C 1 2/23/07 0848 2/26/07 1023 ND ND ND Q3924 960 U2-C1 2/26/07 1023 2/28/07 1040 ND ND ND Q3924D 960 U2-C1 2/26/07 1023 2/28/07 1040 ND ND ND Q4126 960 U2-C1 2/28/07 1040 3/2/07 1020 516:1
- 0.364 ND ND Q4230 960 U2-C1 3/2/07 1020 3/5/07 1114 515.0
- 0.603 ND ND Q4603 960 U2-C1 3/5/07 1114 3/7/07 1400 514.6*
0.457 ND ND Q4718 960 U2-C 1 3/7/07 1400 3/9/07 0903 ND ND ND Q0813 970 MW-62A (55')
11/16/06 1428 11/21/06 0758 ND ND ND Q1045 970 MW-62A (55')
11/21/06 0758 11/28/06 0832 ND ND ND Q1276 970 MW-62A (55')
11/28/06 0832 12/5/06 1045 ND ND ND Q2095 970 MW-62A (55')
1/16/07 1335 2/1/07 1005 ND ND ND Q2424 970 MW-62A (55')
2/1/07 1005 2/8/07 1400 ND ND ND Q2458 970 MW-62A (55')
2/8/07 1400 2/9/07 1008 ND ND ND Q2575 970 MW-62A (55')
2/9/07 1400 2/10/07 0818 ND ND ND Q2538 970 MW-62A (55')
2/10/07 0818 2/11/07 0821 ND ND ND Q2659 970 MW-62A (55')
2/11/07 0821 2/12/07 1005 ND ND ND Q2874 970 MW-62A (55')
2/12/07 1255 2/13/07 1000 ND ND ND Q2932 970 MW-62A (55')
2/13/07 1000 2/14/07 1010 ND ND ND Q3253 970 MW-62A (55')
2/14/07 1010 2/16/07 1158 ND ND ND Q3319 970 MW-62A (55')
2/16/07 1158 2/19/07 0816 ND ND ND Q3516 970 MW-62A (55')
2/19/07 0816 2/21/07 0830 ND ND ND Q3863 970 MW-62A (55')
2/21/07 0830 2/23/07 0940 ND ND ND
+
f:\\docs\\coa\\GZA.xls 3/19/2007 34
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak mn Conc. ppb Q3605 970 MW-62A (55')
2/23/07 0940 2/26/07 1058 ND ND ND Q3953 970 MW-62A (55')
2/26/07 1059 2/28/07 1112 ND ND ND Q4142 970 MW-62A (55')
2/28/07 1112 3/2/07 1005 ND ND ND Q4196 970 MW-62A (55')
3/2/07 1005 3/5/07 1025 ND ND ND Q4567 970 MW-62A (55')
3/5/07 1025 3/7/07 1158 ND ND ND Q4748 970 MW-62A (55')
3/7/07 1159 3/9/07 0920 ND ND ND Q0814 980 MW-62B (83')
11/16/06 1422 11/21/06 0800 ND ND ND Q1046 980 MW-62B (83')
11/21/06 0800 11/28/06 0835 ND ND ND Q1277 980 MW-62B (83')
11/28/06 0835 12/5/06 1050 ND ND ND Q2096 980 MW-62B (83')
1/16/07 1335 2/1/07 1005 ND ND ND Q2425 980 MW-62B (83')
2/1/07 1005 2/8/07 1400 ND ND ND Q2459 980 MW-62B (83')
2/8/07 1400 2/9/07 1009 ND ND ND Q2576 980 MW-62B (83')
2/9/07 1400 2/10/07 0818 ND ND ND Q2539 980 MW-62B (83')
2/10/07 0818 2/11/07 0821 ND ND ND Q2661 980 MW-62B (83')
2/11/07 0821 2/12/07 1005 ND ND ND Q2875 980 MW-62B (83')
2/12/07 1005 2/13/07 1000 ND ND ND Q2933 980 MW-62B (83')
2/13/07 1000 2/14/07 1010 ND ND ND Q3254 980 MW-62B (83')
2/14/07 1010 2/16/07 1158 ND ND ND Q3321 980 MW-62B (83')
2/16/07 1158 2/19/07 0816 ND ND ND Q3517 980 MW-62B (83')
2/19/07 0816 2/21/07 0830 ND ND ND Q3864 980 MW-62B (83')
2/21/07 0830 2/23/07 0940 ND ND ND Q3606 980 MW-62B (83')
2/23/07 0940 2/26/07 1058 ND ND ND Q3954 980 MW-62B (83')
2/26/07 1059 2/28/07 1112 ND ND ND Q4143 980 MW-62B (83')
2/28/07 1112 3/2/07 1005 ND ND ND Q4197 980 MW-62B (83')
3/2/07 1005 3/5/07 1025 ND ND ND Q4568 980 MW-62B (83')
3/5/07 1025 3/7/07 1159 ND ND ND Q4749 980 MW-62B (83')
3/7/07 1159 3/9/07 0920 ND ND ND Q0815 990 MW-62-18 11/16/06 1406 11/21/06 0805 ND IND ND Q1281 990 MW-62-18 11/28/06 0826 12/5/06 1054 ND IND IND Q2099 990 MW-62-18 1/16/07 1325 2/1/07 1029 ND IND IND f:\\docs\\coa\\GZA.xls 3/19/2007 35
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q2428 990 MW-62-18 2/1/07 1029 2/8/07 1345 ND ND ND Q2463 990 MW-62-18 2/8/07 1345 2/9/07 1019 ND ND ND Q2579 990 MW-62-18 2/9/07 1345 2/10/07 0810 ND ND ND Q2543 990 MW-62-18 2/10/07 0810 2/11/07 0816 ND ND ND Q2664 990 MW-62-18 2/11/07 0816 2/12/07 0950 ND ND ND Q2878 990 MW-62-18 2/12/07 0950 2/13/07 0955 ND ND ND Q2936 990 MW-62-18 2/13/07 0955 2/14/07 1002 ND ND ND Q3257 990 MW-62-18 2/14/07 1002 2/16/07 1146 ND ND ND Q3324 990
-MW-62-18 2/16/07 1146 2/19/07 0802 ND ND ND Q3521 990 MW-62-18 2/19/07 0802 2/21/07 0820 ND ND ND Q3867 990 MW-62-18 2/21/07 0826 2/23/07 0932 ND ND ND Q3609 990 MW-62-18 2/23/07 0932 2/26/07 1045 ND ND ND Q3957 990 MW-62-18 2/26/07 1045 2/28/07 1056 ND ND ND Q4146 990 MW-62-18 2/28/07 1056 3/2/07 0956 ND ND ND Q4201 990 MW-62-18 3/2/07 0956 3/5/07 1015 ND ND ND Q4571 990 MW-62-18 3/5/07 1015 3/7/07 1145 ND ND ND Q4752 990 MW-62-18 3/7/07 1145 3/9/07 0911 ND ND ND Q0816 1000 MW-62-35 11/16/06 1415 11/21/06 0800 ND ND ND Q1282 1000 MW-62-35 11/28/06 0829 12/5/06 1102 ND ND ND Q2101 1000 MW-62-35 1/16/07 1330 2/1/07 1035 ND ND ND Q2429 1000 MW-62-35 2/1/07 1035 2/8/07 1350 ND ND ND Q2464 1000 MW-62-35 2/8/07 1350 2/9/07 1024 ND ND ND Q2581 1000 MW-62-35 2/9/07 1345 2/10/07 0815 ND ND ND Q2544 1000 MW-62-35 2/10/07 0813 2/11/07 0817 ND ND ND Q2665 1000 MW-62-35 2/11/07 0817 2/12/07 1000 ND ND ND Q2879 1000 MW-62-35 2/12/07 1000 2/13/07 0957 ND ND ND Q2937 1000 MW-62-35 2/13/07 0957 2/14/07 1005 ND ND ND Q3258 1000 MW-62-35 2/14/07 1005 2/16/07 1150 ND ND ND Q3325 1000 MW-62-35 2/16/07 1150 2/19/07 0808 ND ND ND Q3522 1000 MW-62-35 2/19/07 0808 2/21/07 0826 ND ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 36
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak mn Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q3868 1000 MW-62-35 2/21/07 0828 2/23/07 0935 ND ND ND Q3610 1000 MW-62-35 2/23/07 0933 2/26/07 1050 ND ND ND Q3958 1000 MW-62-35 2/26/07 1050 2/28/07 1105 ND ND ND Q4147 1000 MW-62-35 2/28/07 1105 3/2/07 1000 ND ND IND Q4202 1000 MW-62-35 3/2/07 1000 3/5/07 1019 ND ND ND Q4572 1000 MW-62-35 3/5/07 1019 3/5/07 1150 ND ND ND Q4753 1000 MW-62-35 3/7/07 1150 3/9/07 0914 ND ND ND Q1047 1010 MW-62C (138')
11/21/06 0805 11/28/06 0826 ND ND ND Q1278 1010 MW-62C (138')
11/30/06 1500 12/5/06 1051 ND ND ND Q2097 1010 MW-62C (138')
1/16/07 1335 2/1/07 1005 ND ND ND Q2426 1010 MW-62C (138')
2/1/07 1005 2/8/07 1400 ND ND ND Q2461 1010 MW-62C (138')
2/8/07 1400 2/9/07 1011 ND ND ND Q2577 1010 MW-62C (138')
2/9/07 1400 2/10/07 0818 ND ND ND Q2541 1010 MW-62C (138')
2/10/07 0818 2/11/07 0821 ND ND
_ND Q2662 1010 MW-62C (138')
2/11/07 0821 2/12/07 1005 ND ND ND Q2876 1010 MW-62C (138')
2/12/07 1005 2/13/07 1000 ND ND ND Q2934 1010 MW-62C (138')
2/13/07 1000 2/14/07 1010 ND ND ND Q3255 i010 MW-62C (138')
2/14/07 1010 2/16/07 1158 ND ND IND Q3322 1010 MW-62C (138')
2/16/07 1158 2/19/07 0816 ND ND ND Q3518 1010 MW-62C (138')
2/19/07 0816 2/21/07 0830 ND ND ND Q3865 1010 MW-62C (138')
2/21/07 0830 2/23/07 0940 ND ND ND Q3607 1010 MW-62C (138')
2/23/07 0940 2/26/07 1058 ND ND ND Q3955 1010 MW-62C (138')
2/26/07 1059 2/28/07 1112 ND ND ND Q4144 1010 MW-62C (138')
2/28/07 1112 3/2/07 1005 ND ND ND Q4198 1010 MW-62C (138')
3/2/07 1005 3/5/07 1025 ND ND
_ND Q4569 1010 MW-62C (138')
3/5/07 1025 3/7/07 1159 ND ND ND Q4750 1010 MW-62C (138')
3/7/07 1159 3/9/07 0920 ND ND ND-Q1048 1020 MW-62D (182')
11/21/06 0802 11/28/06 0829 ND ND ND Q1279 1020 MW-62D (182')
11/30/06 1501 12/5/06 1052 ND ND ND Q2098 1020 MW-62D (182')
1/16/07 1335 2/1/07 1005 ND ND I
ND f:\\docs\\coa\\GZA.xls 3/19/2007 37
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q2427 1020 MW-62D (182')
2/1/07 1005 2/8/07 1400 ND ND ND Q2462 1020 MW-62D (182')
2/8/07 1400 2/9/07 1015 ND ND ND Q2578 1020 MW-62D (182')
2/9/07 1400 2/10/07 0818 ND ND IND Q2542 1020 MW-62D (182')
2/10/07 0818 2/11/07 0821 ND
_ND ND Q2663 1020 MW-62D (182')
2/11/07 0821 2/12/07 1005 ND ND ND Q2877 1020 MW-62D (182')
2/12/07 1005 2/13/07 1000 ND ND ND Q2935 1020 MW-62D (182')
2/13/07 1000 2/14/07 1010 ND ND ND Q3256 1020 MW-62D (182')
2/14/07 1010 2/16/07 1158 ND ND ND Q3323 1020 MW-62D (182')
2/16/07 1158 2/19/07 0816 ND ND ND Q3519 1020 MW-62D (182')
2/19/07 0816 2/21/07 0830 ND ND ND Q3866 1020 MW-62D (182')
2/21/07 0830 2/23/07 0940 ND ND ND Q3608 1020 MW-62D (182')
2/23/07 0940 2/26/07 1058 ND ND ND Q3956 1020 MW-62D (182')
2/26/07 1059 2/28/07 1112 ND ND ND Q4145 1020 MW-62D (182')
2/28/07 1112 3/2/07 1005 ND ND
_ND Q4199 1020 MW-62D (182')
3/2/07 1005 3/5/07 1025 ND ND ND Q4570 1020 MW-62D (182')
3/5/07 1025 3/7/07 1159 ND ND
_ND Q4751 1020 MW-62D (182')
3/7/07 1159 3/9/070920 ND ND ND Q0817 1030 MW-63A (52')
11/15/06 1025 11/20/06 1345 ND ND IND Q1049 1030 MW-63A (52')
11/20/06 1345 11/28/06 0855 ND ND ND Q1283 1030 MW-63A (52')
11/28/06 0855 12/5/06 1410 ND ND ND Q1942 1030 MW-63A (52')
1/12/07 1403 1/23/07 1411 516.0
- 0.689 ND ND Q2086 1030 MW-63A (52')
1/23/07 1411 2/1/07 1145 ND ND ND Q2484 1030 MW-63A (52')
2/1/07 1145 2/8/07 1207 ND ND ND Q2414 1030 MW-63A (52')
2/8/07 1207 2/9/07 1059 ND ND ND Q2567 1030 MW-63A (52')
2/9/07 1059 2/10/07 1012 ND ND ND Q2530 1030 MW-63A (52')
2/10/07 1012 2/11/07 0737 ND ND ND Q2651 1030 MW-63A (52')
2/11/07 0737 2/12/07 1141 ND ND ND Q2866 1030 MW-63A (52')
2/12/07 1141 2/13/07 0832 ND ND ND Q2924 1030 MW-63A (52')
2/13/07 0852 2/14/07 0911 ND ND ND Q3245 1030 MW-63A (52')
2/14/07 0911 2/16/07 1300 ND ND I
ND f:\\docs\\coa\\GZA.xls 3/19/2007 38
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak mn Conc. ppb Q3311 1030 MW-63A(52')
2/16/07 1300 2/19/07 1006 ND ND ND Q3508 1030 MW-63A (52')
2/19/07 1006 2/21/07 1052 ND ND ND Q3854 1030 MW-63A (52')
2/21/07 1052 2/23/07 1027 ND ND ND Q3596 1030 MW-63A (52')
2/23/07 1027 2/26/07 1127 ND ND ND Q3945 1030 MW-63A (52')
2/26/07 1127 2/28/07 1140 ND ND ND Q4170 1030 MW-63A (52')
2/28/07 1148 3/2/07 1054 ND ND ND Q4188 1030 MW-63A (52')
3/2/07 1054 3/5/07 1053 ND ND ND Q4558 1030 MW-63A (52')
3/5/07 1053 3/7/07 1348 ND ND ND Q1943 1040 MW-63B (85')
1/12/07 1403 1/23/07 1411 515.8
- 0.472 ND ND Q2087 1040 MW-63B (85')
1/23/07 1411 2/1/07 1151 ND ND ND Q2485 1040 MW-63B (85')
2/1/07 1151 2/8/07 1208 ND ND ND Q2415 1040 MW-63B (85')
2/8/07 1208 2/9/07 1059 ND ND ND Q2568 1040 MW-63B (85')
2/9/07 1059 2/10/07 1012 ND ND ND Q2531 1040 MW-63B (85')
2/10/07 1012 2/11/07 0737 ND ND ND Q2652 1040 MW-63B (85')
2/11/07 0737 2/12/07 1141 ND ND ND Q2867 1040 MW-63B (85')
2/12/07 1141 2/13/07 0852 ND ND ND Q2925 1040 MW-63B (85')
2/13/07 0852 2/14/07 0911 ND ND ND Q3246 1040 MW-63B (85')
2/14/07 0911 2/16/07 1300 ND ND IND Q3312 1040 MW-63B (85')
2/16/07 1300 2/19/07 1006 ND ND ND Q3509 1040 MW-63B (85')
2/19/07 1006 2/21/07 1052 ND ND ND Q3855 1040 MW-63B (85')
2/21/07 1052 2/23/07 1027 ND ND ND Q3597 1040 MW-63B (85')
2/23/07 1027 2/26/07 1127 ND ND ND Q3946 1040 MW-63B (85')
2/26/07 1127 2/28/07 1148 ND ND ND Q4134 1040 MW-63B (85')
2/28/07 1148 3/2/07 1054 ND ND ND Q4189 1040 MW-63B (85')
3/2/07 1054 3/5/07 1053 ND ND ND Q4559 1040 MW-63B (85')
3/5/07 1053 3/7/07 1348 ND ND ND Q0819 1050 MW-63-18 11/15/06 0955 11/20/06 1400 ND ND ND Q1051 1050 MW-63-18 11/20/06 1400 11/28/060849 ND ND ND Q1285 1050 MW-63-18 11/28/06 0849 12/5/06 1405 ND ND ND Q1946 1050 MW-63-18 1/12/07 1352 1/23/07 1407 ND ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 39
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q2090 1050 MW-63-18 1/23/07 1407 2/1/07 1133 ND ND ND Q2488 1050 MW-63-18 2/1/07 1133 2/8/07 1149 ND ND ND Q2418 1050
-MW-63-18 2/8/07 1149 2/9/071052 ND ND ND Q2571 1050 MW-63-18 2/9/07 1052 2/10/07 1003 ND ND ND Q2534 1050 MW-63-18 2/10/07 1003 2/11/07 0729 ND ND ND Q2655 1050 MW-63-18 2/11/07 0729 2/12/07 1111 ND ND ND Q2870 1050 MW-63-18 2/12/07 1111 2/13/07 0846 ND ND ND Q2928 1050 MW-63-18 2/13/07 0846 2/14/07 0904 ND ND ND Q3249 1050 MW-63-18 2/14/07 0904 2/16/07 1250 ND ND ND Q3315 1050 MW-63-18 2/16/07 1250 2/19/07 0955 ND ND ND Q3512 1050 MW-63-18 2/19/07 0955 2/21/07 1040 ND ND ND Q3858 1050 MW-63-18 2/21/07 1040 2/23/07 1014 ND ND ND Q3601 1050 MW-63-18 2/23/07 1014 2/26/07 1115 ND ND ND Q3949 1050 MW-63-18 2/26/07 1115 2/28/07 1132 ND ND ND Q4137 1050 MW-63-18 2/28/07 1132 3/2/07 1045 ND ND ND Q4192 1050 MW-63-18 3/2/07 1045 3/5/07 1043 ND ND ND Q4563 1050 MW-63-18 3/5/07 1043 3/7/07 1336 ND ND ND Q0821 1060 MW-63-35 11/15/06 1005 11/20/06 1405 ND ND ND Q1052 1060 MW-63-35 11/20/06 1405 11/28/06 0853 ND ND ND Q1286 1060 MW-63-35 11/28/06 0853 12/5/06 1400 ND ND ND Q1947 1060 MW-63-35 1/12/07 1347 1/23/07 1400 ND ND ND Q2091 1060 MW-63-35 1/23/07 1400 2/1/07 1139 ND ND ND Q2489 1060 MW-63-35 2/1/07 1139 2/8/07 1158 ND ND ND Q2419 1060 MW-63-35 2/8/07 1158 2/9/07 1053 ND ND ND Q2572 1060 MW-63-35 2/9/07 1053 2/10/07 1006 ND ND ND Q2535 1060 MW-63-35 2/10/07 1006 2/11/07 0734 ND ND ND Q2656 1060 MW-63-35 2/11/07 0734 2/12/07 1130 ND ND ND Q2871 1060 MW-63-35 2/12/07 1130 2/13/07 0849 ND ND ND Q2929 1060 MW-63-35 2/13/07 0849 2/14/07 0908 ND ND ND Q3250 1060 MW-63-35 2/14/07 0908 2/16/07 1255 ND ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 40
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q3316 1060 MW-63-35 2/16/07 1255 2/19/07 1000 ND ND ND Q3513 1060 MW-63-35 2/19/07 1000 2/21/07 1045 ND ND ND Q3859 1060 MW-63-35 2/21/07 1045 2/23/07 1019 ND
. ND ND Q3602 1060 MW-63-35 2/23/07 1019 2/26/07 1120 ND ND ND Q3950 1060 MW-63-35 2/26/07 1120 2/28/07 1140 ND ND ND Q4138 1060 MW-63-35 2/28/07 1140 3/2/07 1049 ND ND ND Q4193 1060 MW-63-35 3/2/07 1049 3/5/07 1046 ND ND
_ND Q4564 1060 MW-63-35 3/5/07 1046 3/7/07 1338 ND ND ND Q0818 1070 MW-63C (125')
11/15/06 1040 11/20/06 1350 ND ND ND Q1050 1070 MW-63C (125')
11/20/06 1350 11/28/06 0900 ND ND ND Q1284 1070 MW-63C (125')
11/28/06 0900 12/5/06 1415 ND ND ND Q1944 1070 MW-63C (125')
1/12/07 1403 1/23/07 1411 ND ND ND Q2088 1070 MW-63C (125')
1/23/07 1411 2/1/07 1156 ND ND ND Q2486 1070 MW-63C (125')
2/1/07 1156 2/8/07 1209 ND ND ND Q2416 1070 MW-63C (125')
2/8/07 1209 2/9/07 1059 ND ND ND Q2569 1070 MW-63C (125')
2/9/07 1059 2/10/07 1012 ND ND ND Q2532 1070 MW-63C (125')
2/10/07 1012 2/11/07 0737 ND ND ND Q2653 1070 MW-63C (125')
2/11/07 0737 2/12/07 1141 ND ND IND Q2868 1070 MW-63C (125')
2/12/07 1141 2/13/07 0852 ND ND
_ND Q2926 1070 MW-63C (125')
2/13/07 0852 2/14/07 0911 ND ND ND Q3247 1070 MW-63C (125')
2/14/07 0911 2/16/07 1300 ND ND ND Q3313 1070 MW-63C (125')
2/16/07 1300 2/19/07 1006 ND ND ND Q3510 1070 MW-63C (125')
2/19/07 1006 2/21/07 1052 ND ND ND Q3856 1070 MW-63C (125')
2/21/07 1052 2/23/07 1027 ND ND ND Q3598 1070 MW-63C (125')
2/23/07 1027 2/26/07 1127 ND ND ND Q3947 1070 MW-63C (125')
2/26/07 1127 2/28/07 1148 ND ND ND Q4135 1070 MW-63C (125')
2/28/07 1148 3/2/07 1054 ND ND ND Q4190 1070 MW-63C (125')
3/2/07 1054 3/5/07 1053 ND ND ND Q4561 1070 MW-63C (125')
3/5/07 1053 3/7/07 1348 ND ND ND Q1945 1080 MW-63D (177')
1/12/07 1403 1/23/07 1411 ND ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 41
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers C
GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q2089 1080 MW-63D (177')
1/23/071411 2/1/07 1159 ND ND ND Q2487 1080 MW-63D (177')
2/1/07 1159 2/8/07 1210 ND ND ND Q2417 1080 MW-63D (177')
2/8/07 1210 2/9/07 1059 ND ND ND Q2570 1080 MW-63D (177')
2/9/07 1059 2/10/07 1012 ND ND ND Q2533 1080 MW-63D (177')
2/10/07 1012 2/11/07 0737 ND ND ND Q2654 1080 MW-63D (177')
2/11/07 0737 2/12/07 1141 ND ND ND Q2869 1080 MW-63D (177')
2/12/07 1141 2/13/07 0852 ND ND ND Q2927 1080 MW-63D (177')
2/13/07 0852 2/14/07 0911 ND ND ND Q3248 1080 MW-63D (177')
2/14/07 0911 2/16/07 1300 ND ND ND Q3314 1080 MW-63D (177')
2/16/07 1300 2/19/07 1006 ND ND ND Q3511 1080 MW-63D (177')
2/19/07 1006 2/21/07 1052 ND ND ND Q3857 1080 MW-63D (177')
2/21/07 1052 2/23/07 1027 ND ND ND Q3599 1080 MW-63D (177')
2/23/07 1027 2/26/07 1127 ND ND ND Q3948 1080 MW-63D (177')
2/26/07 1127 2/28/07 1148 ND ND ND Q4136 1080 MW-63D (177')
2/28/07 1148 3/2/07 1054 ND ND ND Q4191 1080 MW-63D (177')
3/2/07 1054 3/5/07 1053 ND ND ND Q4562 1080 MW-63D (177')
3/5/07 1053 3/7/07 1348 ND ND ND Q0822 1090 MW-65B (74') (upgradient control) 11/15/06 1406 11/20/06 1345 ND ND ND Q1053 1090 MW-65B (74') (upgradient control) 11/20/06 1345 11/27/06 1328 ND ND ND Q1949 1090 MW-65-80' (upgradient control) 1/10/07 0941 1/24/07 1338 ND ND ND Q3282 1090 MW-65-80' (upgradient control) 1/24/07 1338 2/15/07 0855 ND ND ND Q4097 1090 MW-65-80 2/15/07 0855 3/2/07 1218 ND ND ND Q1948 1095 MW-65-48' (upgradient control) 1/10/07 0944 1/24/07 1334 ND ND ND Q3283 1095 MW-65-48' (upgradient control) 1/24/07 1334 2/15/07 0850 ND ND ND Q4096 1095 MW-65-48' (upgradient control) 2/15/07 0850 3/2/07 1212 ND ND ND Q0823 1100 MW107 (open hole control) 11/14/06 1151 11/20/06 1120 ND ND ND Q1054 1100 MW-107 (open hole control) 11/20/06 1120 11/27/06 1344 ND ND ND Q1287 1100 MW-107 (open hole control) 11/27/06 1344 12/4/06 0810 ND ND ND Q1950 1100 MW-107 (open hole control) 1/12/07 1020 1/24/07 1155 ND ND ND Q3284 1100 MW-107 (open hole control) 1/24/07 1155 2/15/07 1103 ND ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 42
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak mn Conc. ppb Q4098 1100 MW-107 (open hole control) 2/15/07 1103 3/1/07 1340 ND ND ND Q0828 1123 MW-111 11/14/06 0923 11/20/06 1012 ND ND ND Q1056 1123 MW-111 11/24/06 1012 11/27/060817 514.6
- 0.366 ND ND Q1288 1123 MW-111 11/27/06 0817 12/5/06 1011 ND ND ND Q2065 1123 MW-111 1/15/07 1340 2/1/07 1353 516.8
- 0.682 ND ND Q2453 1123 MW-111 2/1/07 1353 2/8/07 0950 ND ND ND Q2394 1123 MW-111 2/8/07 0950 2/9/07 1038 ND ND ND Q2509 1123 MW-111 2/9/07 1038 2/10/07 0830 ND ND ND Q2605 1123 MW-111 2/10/07 0830 2/11/07 0810 ND ND ND Q2631 1123 MW-ll1 2/11/07 0810 2/12/07 0905 ND ND ND Q2845 1123 MW-111 2/12/07 0905 2/13/07 0855 ND ND ND Q2904 1123 MW-111 2/13/07 0855 2/14/07 0820 ND ND ND Q3226 1123 MW-111 2/14/07 0820 2/16/07 0838 ND ND ND Q3349 1123 MW-111 2/16/07 0838 2/19/07 0908 ND ND ND Q3488 1123 MW-111 2/19/07 0908 2/21/07 0825 ND ND ND Q3834 1123 MW-111 2/21/07 0825 2/23/07 0815 ND ND ND Q3576 1123 MW-111 2/23/07 0815 2/26/07 0945 ND ND ND Q3922 1123 MW-111 2/26/07 0945 2/28/07 0948 ND ND ND Q4124 1123 MW-111 2/28/07 0948 3/2/07 0955 516.6*
0.544 ND ND Q4228 1123 MW-111 3/2/070955 3/5/070856 515.5 1.18 ND ND Q4601 1123 MW-111 3/5/070856 3/7/07 1035 515.2 7.23 ND ND Q4716 1123 MW-111 3/7/07 1035 3/9/07 0810 515.3 8.94 ND ND Q0829 1125 N. Curtain Drain 11/15/06 1101 11/21/06 0850 ND ND ND Q1061 1125 N. Curtain Drain 11/21/06 0850 11/28/06 0850 ND ND ND Q1289 1125 N. Curtain Drain 11/28/06 0850 12/6/06 0835 ND ND IND Q1951 1125 N. Curtain Drain 1/15/07 0953 1/23/07 1025 ND ND ND Q1951D 1125 N. Curtain Drain 1/15/07 0953 1/23/07 1025 ND ND ND Q3285 1125 N. Curtain Drain 1/23/06 1025 2/15/07 1445 ND ND ND Q3285D 1125 N. Curtain Drain 1/23/07 1025 2/15/07 1445 ND ND ND Q4099 1125 N. Curtain Drain 2/15/07 1445 3/1/07 1149 ND ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 43
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak mu Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q4239 1125 N. Curtain Drain 3/1/07 1012 3/5/07 0750 ND ND ND Q4612 1125 N. Curtain Drain 3/5/07 0000 3/7/07 1440 ND ND ND Q4727 1125 N. Curtain Drain 3/7/07 1440 3/9/07 1145 ND ND ND Q0830 1127 Sump 11/15/06 1044 11/21/06 0835 ND ND ND Q0830D 1127 Sump 11/15/06 1044 11/21/06 0835 ND ND ND Q1062 1127 Sump 11/21/06 0835 11/28/06 0835 ND ND IND Q1290 1127 Sump 11/28/06 0838 12/6/06 0858 ND ND ND Q1290D 1127 Sump 11/28/06 0838 12/6/06 0858 ND ND ND Q1952 1127 Sump 1/15/07 0945 1/23/07 1017 ND ND ND Q1952D 1127 Sump 1/15/07 0945 1/23/07 1017 ND ND ND Q3286 1127 Sump 1/23/07 1017 2/15/07 1440 515.9 2.67 ND ND Q4101 1127 Sump 2/15/07 1440 3/1/07 1143 516.0*
0.316 ND ND Q4101D 1127 Sump 2/15/07 1440 3/1/07 1143 515.2 18.2 ND ND Q4133 1127 Sump 3/1/07 1143 3/2/07 0820 ND ND ND Q4238 1127 Sump 3/2/07 0820 3/5/07 0745 ND ND ND Q4611 1127 Sump 3/5/07 0745 3/7/07 1435 ND ND ND Q4726 1127 Sump 3/7/07 1435 3/9/07 1140 ND ND ND Q0824 1150 U3-3 11/15/06 1316 11/20/06 1405 ND ND ND Q1055 1150 U3-3 11/20/06 1405 11/27/06 1301 ND ND ND Q1291 1150 U3-3 11/27/06 1301 12/4/06 1010 ND ND ND Q3287 1150 U3-3 1/24/07 0955 2/13/07 1330 ND ND ND Q4102 1150 U3-3 2/13/07 1330 3/1/07 0948 ND ND ND Q1953 1160 U3-4D 1/4/07 1153 1/24/07 0940 ND ND ND Q3288 1160 U3-4D 1/24/07 0940 2/13/07 1409 ND ND ND Q4103 1160 U3-4D 2/13/07 1409 3/1/07 1012 517.4*
0.858 ND ND Q1924 1180 MW-44-67 1/8/07 1115 1/24/07 1051 ND ND ND Q3289 1180 MW-44-67 1/24/07 1051 2/13/07 1515 ND ND ND Q4694 1180 MW-44-67 2/13/07 1520 3/5/07 1315 ND ND ND Q1925 1185 MW-44-104 1/10/07 1058 1/24/07 1057 ND ND ND Q3290 1185 MW-44-104 1/24/07 1057 2/13/07 1520 ND ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 44
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q4693 1185 MW-44-104 2/13/07 1515 3/5/07 1319 ND ND ND Q1926 1190 MW-45-43 1/10/07 1117 1/24/07 1120 ND ND ND Q3291 1190 MW-45-43 1/24/07 1120 2/13/07 1340 ND ND ND Q4087 1190 MW-45-43 2/15/07 1340 3/1/07 1100 ND ND ND Q1927 1195 MW-45-67 1/10/07 1158 1/24/07 1110 ND ND ND Q3292 1195 MW-45-67 1/24/07 1110 2/15/07 1345 ND ND ND Q4695 1195 MW-45-67 2/15/07 1345 3/8/07 1150 ND ND ND Q1928 1200 MW-46 1/4/07 1136 1/24/07 0950 ND ND ND Q3293 1200 MW-46 1/24/07 0950 2/13/07 1400 ND ND ND Q4088 1200 MW-46 2/13/07 1400 3/1/07 1027 ND ND ND Q2092 1210 U3-C1 1/25/07 1450 2/2/07 0918 515.0
- 0.680 ND ND Q2092D 1210 U3-C1 1/25/07 1450 2/2/07 0918 515.8
- 0.488 ND IND Q2490 1210 U3-C1 2/2/07 0918 2/8/07 1412 517.0*
0.528 ND ND Q2421 1210 U3-C1 2/8/07 1412 2/9/07 1127 ND ND ND Q2421D 1210 U3-C1 2/8/07 1412 2/9/07 1127 ND ND ND Q2573 1210 U3-C1 2/9/07 1127 2/10/07 1038 ND ND ND Q2536 1210 U3-C1 2/10/07 1038 2/11/07 0954 ND ND ND Q2657 1210 U3-C1 2/11/07 0954 2/12/07 1305 ND ND ND Q2872 1210 U3-C1 2/12/07 1138 2/13/07 1028 ND ND ND Q2930 1210 U3-C1 2/13/07 1028 2/14/07 1032 ND ND ND Q2930D 1210 U3-C1 2/13/07 1028 2/14/07 1032 ND ND ND Q3251 1210 U3-C1 2/14/07 1032 2/16/07 0901 515.8
- 0.440 ND ND Q3251D 1210 U3-C1 2/14/07 1032 2/16/07 0901 515.8
- 0.270 ND ND Q3317 1210 U3-C1 2/16/07 0901 2/19/07 1030 516.0
- 0.439 ND ND Q3514 1210 U3-C1 2/19/07 1030 2/21/07 1120 ND ND ND Q3514D 1210 U3-C1 2/19/07 1030 2/21/07 1120 ND ND ND Q3861 1210 U3-C1 2/21/07 1120 2/23/07 1130 ND ND ND Q3603 1210 U3-C1 2/23/07 1130 2/26/07 1312 ND IND ND Q3603D 1210 U3-C1 2/23/07 1130 2/26/07 1312 ND IND ND Q3951 1210 U3-C1 2/26/07 1312 2/28/07 1407 ND IND ND f:\\docs\\coa\\GZA.xls 3/19/2007 45
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nn Conc.ppb Peak nm Conc. ppb Peak nm Conc. ppb Q4139 1210 U3-C1 2/28/07 1407 3/2/07 1254 515.8
- 0.439 ND ND Q4139D 1210 U3-C1 2/28/07 1407 3/2/07 1254 514.4
- 0.564 ND ND Q4194 1210 U3-C1 3/2/07 1254 3/5/07 1246 515.0 0.830 ND ND Q4565 1210 U3-C1 3/5/07 1246 3/7/07 1503 514.9
- 0.573 ND ND Q4746 1210 U3-C1 3/7/07 1503 3/9/07 1053 ND ND IND Q4746D 1210 U3-C1 3/7/07 1503 3/9/07 1053 ND ND ND Q2068 1220 HR-1 1/25/07 1038 2/1/07 1119 513.6
- 0.447 ND ND Q2456 1220 HR-1 2/1/07 1119 2/8/07 1535 ND ND ND Q2456D 1220 HR-1 2/1/07 1119 2/8/07 1535 ND ND ND Q2397 1220 HR-1 2/8/07 1535 2/9/07 1340 ND ND ND Q2397D 1220 HR-I 2/8/07 1535 2/9/07 1340 ND ND ND Q2512 1220 HR-1 2/9/07 1340 2/10/07 1010 ND ND ND Q2608 1220 HR-1 2/10/07 1010 2/11/07 0915 ND ND ND Q2634 1220 HR-1 2/11/07 0915 2/12/07 1010 ND ND ND Q2848 1220 HR-1 2/12/07 1010 2/13/07 0950 ND ND ND Q2848D 1220 HR-1 2/12/07 1010 2/13/07 0950 ND ND ND Q2907 1220 HR-1 2/13/07 0950 2/14/07 1020 ND ND ND Q3491 1220 HR-1 2/14/07 1020 2/21/07 1015 ND ND ND Q3491D 1220 HR-1 2/14/07 1020 2/21/07 1015 515.0
- 0.442 ND IND Q3837 1220 HR-1 2/21/07 1015 2/23/07 0930 ND ND ND Q3837D 1220 HR-1 2/21/07 1015 2/23/07 0930 ND ND ND Q3579 1220 HR-1 2/23/07 0930 2/26/07 0910 ND ND ND Q3925 1220 HR-1 2/26/07 0910 2/28/07 1055 ND ND ND Q4127 1220 HR-I 2/28/07 1055 3/2/07 1040 ND ND ND Q4231 1220 HR-I 3/2/07 1040 3/5/07 1020 ND ND ND Q4604 1220 HR-1 3/5/07 1020 3/7/07 1138 ND ND ND Q2069 1230 Hudson River Unit 3 Intake 1/25/07 1415 2/1/07 1015 514.6
- 0.868 ND ND Q2069D 1230 Hudson River Unit 3 Intake 1/25/07 1415 2/1/07 1015 512.6
- 0.918 ND ND Q2513 1230 Hudson River Unit 3 Intake 2/1/07 1015 2/10/07 1002 ND ND ND Q2513D 1230 Hudson River Unit 3 Intake 2/1/07 1015 2/10/07 1002 ND ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 46
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nmn Conc. ppb Peak nm Conc. ppb Peak nm Conc. ppb Q2609 1230 Hudson River Unit 3 Intake 2/10/07 1002 2/11/07 0920 ND ND ND Q2849 1230 Hudson River Unit 3 Intake 2/11/07 0920 2/13/07 1002 ND ND ND Q2093 1260 Unit 3 Discharge Canal 2/2/07 0940 2/5/07 0844 513.0
- 0.305 ND ND Q2491 1260 Unit 3 Discharge Canal 2/5/07 0844 2/8/07 1353 ND ND ND Q2422 1260 Unit 3 Discharge Canal 2/8/07 1353 2/9/07 1116 ND ND ND Q2574 1260 Unit 3 Discharge Canal 2/9/07 1116 2/10/07 1029 ND ND ND Q2574D 1260 Unit 3 Discharge Canal 2/9/07 1116 2/10/07 1029 ND ND ND Q2537 1260 Unit 3 Discharge Canal 2/10/07 1029 2/11/07 0944 ND ND ND Q2537D 1260 Unit 3 Discharge Canal 2/10/07 1029 2/11/07 0944 ND ND ND Q2658 1260 Unit 3 Discharge Canal 2/11/07 0944 2/12/07 1255 ND ND ND Q2658D 1260 Unit 3 Discharge Canal 2/11/07 0944 2/12/07 1255 ND ND ND Q2873 1260 Unit 3 Discharge Canal 2/12/07 1305 2/13/07 0902 ND ND ND Q2873D 1260 Unit 3 Discharge Canal 2/12/07 1305 2/13/07 0902 ND ND ND Q2931 1260 Unit 3 Discharge Canal 2/13/07 0902 2/14/07 1025 ND ND ND Q3252 1260 Unit 3 Discharge Canal 2/14/07 1025 2/16/07 0849 514.8
- 0.286 ND ND Q3318 1260 Unit 3 Discharge Canal 2/16/07 0849 2/19/07 1015 515.2
- 0.556 ND 570.0
- 4.64 Q3318D 1260 Unit 3 Discharge Canal 2/16/07 0849 2/19/07 1015 516.6
- 0.393 ND 570.6
- 3.28 Q3515 1260 Unit 3 Discharge Canal 2/19/07 1015 2/21/07 1108 ND ND ND Q3862 1260 Unit 3 Discharge Canal 2/21/07 1108 2/23/07 1115 ND ND ND Q3862D 1260 Unit 3 Discharge Canal 2/21/07 1108 2/23/07 1115 ND ND ND Q3604 1260 Unit 3 Discharge Canal 2/23/07 1115 2/26/07 1300 ND ND ND Q3952 1260 Unit 3 Discharge Canal 2/26/07 1300 2/28/07 1215 ND ND ND Q3952D 1260 Unit 3 Discharge Canal 2/26/07 1300 2/28/07 1215 ND ND ND Q4141 1260 Unit 3 Discharge Canal 2/28/07 1215 3/2/07 1143 515.2
- 0.331 ND ND Q4195 1260 Unit 3 Discharge Canal 3/2/07 1143 3/5/07 1147 513.8
- 0.514 ND ND Q4566 1260 Unit 3 Discharge Canal 3/5/07 1147 3/7/07 1455 513.6
- 0.501 ND IND Q4747 1260 Unit 3 Discharge Canal 3/7/07 1455 3/9/07 1033 ND ND ND Q4237 1270 CSS-Unit 1 3/2/07 0805 3/5/07 1335 515.5 40.6 ND ND Q4610 1270 CSS-Unit 1 3/5/07 1335 3/7/07 1430 515.4 46.5 ND ND Q4725 1270 CSS-Unit 1 3/7/07 1430 3/9/07 1255 515.3 7.92 ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 47
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Charcoal Samplers GZA Environmental, Inc.
OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Results RWT Results Placed Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak mn Conc. ppb Q4761 1300 MW-108 3/7/07 1320 3/9/07 1045 515.4
- 1.14 ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 48
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
Table 2.
Results for water samples analyzed for the presence of fluorescein, eosine and rhodamine WT (RWT) dyes.
Peak wavelengths are reported in nanometers (nm); dye concentrations are reported in parts per billion (ppb).
Results through 3/9/07 OUL Station Station Name Date/Time Fluorescein Results Eosine Results RWT Re Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q1292 30 Hudson River downstream 12/4/06 0846 ND ND ND Q4625 80 MH4 3/2/07 0940 508.3 0.482 ND ND Q4626 80 MH4 3/5/07 0906 508.3 41.4 ND ND Q2946 100 MH5 2/12/07 0855 508.7 1.18 ND ND Q2971 100 MH5 2/13/07 0845 508.7 7.00 ND ND Q2972 100 MH5 2/14/07-0830 508.7 12.1 ND ND Q3357 100 MH5 2/16/07 0855 508.5 14.9 ND ND Q3361 100 MH5 2/19/07 0930 508.6 16.7 ND ND Q3363 100 MH5 2/21/07 0843 508.6 15.8 ND ND Q3979 100 MH5 2/26/07 1000 508.7 22.4 ND ND Q4258 100 MH5 2/28/07 0957 508.6 16.1 ND ND Q4623 100 MH5 3/2/07 1000 508.1 0.750 ND ND Q4624 100 MH5 3/5/07 0913 508.3 43.1 ND ND Q3981 120 MH6 2/26/07 0904 508.7 3.23 ND ND Q4259 120 MH6 2/28/07 0921 508.6 13.8 ND ND Q4627 120 MH6 3/2/07 0835 508.3 0.168 ND ND Q4628 120 MH6 3/5/07 0905 508.3 1.29 ND ND Q0831 200 MW-30-74 11/21/06 1045 ND ND ND Q1303 200 MW-30-74 11/28/06 1340 ND ND ND Q1305 200 MW-30-74 12/4/06 1114 ND ND ND Q1954 200 MW-30-74 1/17/07 0945 ND ND ND Q2135 200 MW-30-74 1/25/07 1004 ND ND ND Q2117 200 MW-30-74 2/2/07 1415 ND ND ND Q2234 200 MW-30-74 2/8/07 1433 ND ND IND Q2258 200 MW-30-74 2/9/07 1545 ND ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 1
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re OUL Station Station Name Date/Time Fluorescein Results Eosine Results Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q2370 200 MW-30-74 2/10/07 0832 ND ND ND Q2373 200 MW-30-74 2/11/07 1047 508.3 2.13 ND ND Q2373R 200 MW-30-74 2/11/07 1047 508.3 2.13 ND ND Q2344 200 MW-30-74 2/12/07 0828 508.2 3.18 ND ND Q3067 200 MW-30-74 2/13/07 0812 508.2 17.8 ND ND Q3071 200 MW-30-74 2/14/07 0828 508.2 17.8 ND ND Q3044 200 MW-30-74 2/15/07 0812 508.2 25.5 ND ND Q3048 200 MW-30-74 2/16/07 0803 508.2 22.9 ND ND Q3052 200 MW-30-74 2/17/07 0941 508.3 22.3 ND ND Q3056 200 MW-30-74 2/18/07 0936 508.1 16.0 ND ND Q3061 200 MW-30-74 2/19/07 1016 508.3 16.7 ND ND Q3101 200 MW-30-74 2/20/07 0825 508.4 10.9 ND ND Q3124 200 MW-30-74 2/21/07 0859 508.1 20.3 ND ND Q3642 200 MW-30-74 2/22/07 0950 508.5 55.5 ND ND Q3618 200 MW-30-74 2/23/07 0816 508.3 78.1 ND ND Q3686 200 MW-30-74 2/26/07 0923 508.4 34.1 ND ND Q3663 200 MW-30-74 2/27/07 1100 508.1 21.5 ND ND Q3874 200 MW-30-74 2/28/07 1125 508.2 18.9 ND ND Q4001 200 MW-30-74 3/1/07 1128 508.2 126 ND ND Q4029 200 MW-30-74 3/2/07 0827 508.3 407 ND ND Q4056 200 MW-30-74 3/5/07 0941 508.2 2,220 ND ND Q4535 200 MW-30-74 3/6/07 0931 508.3 2,450 ND ND Q4515 200 MW-30-74 3/7/07 1140 508.5 5,100 ND ND Q4641 200 MW-30-74 3/8/07 0850 508.5 4,700 ND ND Q4658 200 MW-30-74 3/9/07 0900 508.7 4,980 ND ND Q0832 230 MW-30-88 11/21/06 1030 ND ND IND Q1304 230 MW-30-88 11/29/06 1420 ND IND IND Q1293 230 MW-30-88 12/4/06 1105 ND IND IND f:\\docs\\coa\\GZA.xls 3/19/2007 2
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re OUIL Station Station Name Date/Time Fluorescein Results Eosine Results Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q1955 230 MW-30-88 1/17/07 0950 ND ND ND Q2136 230 MW-30-88 1/25/07 1001 ND ND ND Q2118 230 MW-30-88 2/2/07 1415 ND ND ND Q2235 230 MW-30-88 2/8/07 1432 ND ND ND Q2259 230 MW-30-88 2/9/07 1550 ND ND ND Q2259R 230 MW-30-88 2/9/07 1550 ND ND ND Q2369 230 MW-30-88 2/10/07 0840 ND ND ND Q2374 230 MW-30-88 2/11/07 1052 ND ND ND Q2345 230 MW-30-88 2/12/07 0838 508.5 0.184 ND ND Q3068 230 MW-30-88 2/13/07 0818 508.2 4.59 ND ND Q3072 230 MW-30-88 2/14/07 0832 508.2 7.36 ND ND Q3045 230 MW-30-88 2/15/07 0819 508.3 21.7 ND ND Q3049 230 MW-30-88 2/16/07 0808 508.3 37.8 ND ND Q3053 230 MW-30-88 2/17/07 0949 508.5 51.7 ND ND Q3057 230 MW-30-88 2/18/07 0943 508.6 64.0 ND ND Q3062 230 MW-30-88 2/19/07 1028 508.3 87.8 ND ND Q3102 230 MW-30-88 2/20/07 0825 508.7 88.7 ND ND Q3125 230 MW-30-88 2/21/07 0906 508.4 88.6 ND ND Q3643 230 MW-30-88 2/22/07 0940 508.4 88.1 ND ND Q3619 230 MW-30-88 2/23/07 0814 508.5 122 ND ND Q3687 230 MW-30-88 2/26/07 0927 508.7 114 ND ND Q3664 230 MW-30-88 2/27/07 1105 508.3 110 ND ND Q3875 230 MW-30-88 2/28/07 1127 508.2 116 ND ND Q4002 230 MW-30-88 3/1/07 1126 508.3 117 ND ND Q4030 230 MW-30-88 3/2/07 0826 508.2 120 ND ND Q4057 230 MW-30-88 3/5/07 0939 508.5 119 ND ND Q4536 230 MW-30-88 3/6/07 0933 508.4 125 ND ND Q4516 230 MW-30-88 3/7/07 1138 508.5 123 ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 3
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re OUL Station Station Name Date/Time Fluorescein Results Eosine Results Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q4642 230 MW-30-88 3/8/07 0849 508.6 135 ND ND Q4659 230 MW-30-88 3/9/07 0902 508.6 139 ND ND Q0833 240 MW-31-53 11/20/06 1400 ND ND ND Q1065 240 MW-31-53 11/27/06 1145 ND ND ND Q1294 240 MW-31-53 12/4/06 1026 ND ND ND Q1956 240 MW-31-53 1/18/07 0925 ND ND ND Q2137 240 MW-31-53 1/25/07 1129 ND ND ND Q2119 240 MW-31-53 2/1/07 0910 ND ND ND Q2236 240 MW-31-53 2/8/07 1547 508.5 1,600 ND ND Q2261 240 MW-31-53 2/9/07 1708 508.3 746 ND ND Q2297 240 MW-31-53 2/10/07 1025 508.3 1,140 ND ND Q2316 240 MW-31-53 2/11/07 0738 508.2 682 ND ND Q2346 240 MW-31-53 2/12/07 1014 508.9 391 ND ND Q2674 240 MW-31-53 2/13/07 1208 508.4 275 ND ND Q2702 240 MW-31-53 2/14/07 1023 508.3 177 ND ND Q2973 240 MW-31-53 2/15/07 1012 508.2 149 ND ND Q2987 240 MW-31-53 2/16/07 0940 508.3 79.4 ND ND Q3006 240 MW-31-53 2/17/07 0735 508.3 82.5 ND ND Q3025 240 MW-31-53 2/18/07 0738 509 58 ND ND Q3073 240 MW-31-53 2/19/07 0755 508.3 50.5 ND ND Q3103 240 MW-31-53 2/20/07 1015 508.6 69.7 ND ND Q3126 240 MW-31-53 2/21/07 1014 508.1 29.1 ND ND Q3644 240 MW-31-53 2/22/07 1315 508.3 35.3 ND ND Q3621 240 MW-31-53 2/23/07 1003 508.2 24.6 ND ND Q3621R 240 MW-31-53 2/23/07 1003 508.4 24.7 ND ND Q3533 240 MW-31-53 2/26/07 1016 508.5 24.5 ND ND Q3665 240 MW-31-53 2/27/07 1243 507.9 **
29.5 ND ND Q3876 240 MW-31-53 2/28/07 1249 508.1 29.9 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 4
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re OUL Station Station Name Date/Time Fluorescein Results Eosine Results Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q4003 240 MW-31-53 3/1/07 1409 508.2 11.7 ND
_ND Q4031 240 MW-31-53 3/2/07 1046 508 14.4 ND ND Q4058 240 MW-31-53 3/5/07 1208 508A1 6.16 ND ND Q4267 240 MW-31-53 3/6/07 1140 508.1 1.93 ND ND Q4517 240 MW-31-53 3/7/07 1351 508.4 0.468 ND ND Q4643 240 MW-31-53 3/8/07 1019 509.0 0.206 ND ND Q4661 240 MW-31-53 3/9/07 1010 508.3 5.87 ND ND Q0834 250 MW-31-67 11/20/06 1345 ND ND ND Q1066 250 MW-31-67 11/27/06 1210 ND ND ND Q1295 250 MW-31-67 12/4/06 1020 ND ND ND Q1957 250 MW-31-67 1/18/07 0925 ND ND ND Q2138 250 MW-31-67 1/25/07 1127 ND ND ND Q2121 250 MW-31-67 2/1/07 0920 ND ND ND Q2237 250 MW-31-67 2/8/07 1547 ND ND ND Q2262 250 MW-31-67 2/9/07 1711 ND ND ND Q2298 250 MW-31-67 2/10/07 1019 ND ND ND Q2317 250 MW-31-67 2/11/07 0743 508.4 212 ND ND Q2347 250 MW-31-67 2/12/07 1017 508.2 1,030 ND ND Q2675 250 MW-31-67 2/13/07 1212 508.7 3,820 ND ND Q2703 250 MW-31-67 2/14/07 1026 508.3 5,830 ND ND Q2974 250 MW-31-67 2/15/07 1009 508.5 7,500 ND ND Q2988 250 MW-31-67 2/16/07 0942 508.5 8,300 ND ND Q3007 250 MW-31-67 2/17/07 0737 508.5 9,340 ND ND Q3026 250 MW-31-67 2/18/07 0744 508.8 9,310 ND ND Q3074 250 MW-31-67 2/19/07 0805 508.2 10,800 ND ND Q3104 250 MW-31-67 2/20/07 1017 508.6 12,400 ND ND Q3127 250 MW-31-67 2/21/07 1014 508.3 9,230 ND ND Q3645 250 MW-31-67 2/22/07 1320 508.6 9,760 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 5
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re 0111.
~t2tiflfl
- qtation Name Date~/Time Fluiorescein Resul~t*
Eosine Results Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q3622 250 MW-31-67 2/23/07 0958 508.5 12,700 ND ND Q3534 250 MW-31-67 2/26/07 1017 508.4 11,700 ND ND Q3666 250 MW-31-67 2/27/07 1245 508.2 10,400 ND ND Q3877 250 MW-31-67 2/28/07 1250 508.3 11,800 ND ND Q4004 250 MW-31-67 3/1/07 1406 508.2 10,500 ND ND Q4032 250 MW-31-67 3/2/07 1049 508.1 10,200 ND ND Q4059 250 MW-31-67 3/5/07 1206 508.3 9,460 ND D
Q4268 250 MW-31-67 3/6/07 1138 508.3 9,590 ND ND Q4518 250 MW-31-67 3/7/07 1349 508.4 8,790 ND ND Q4644 250 MW-31-67 3/8/07 1020 509.0 8,370 ND ND Q4662 250 MW-31-67 3/9/07 1012 508.8 7,540 ND ND Q0835 260 MW-31-89 11/20/06 1340 ND ND ND Q1067 260 MW-31-89 11/27/06 1220 ND ND ND Q1296 260 MW-31-89 12/4/06 1029 ND ND ND Q1958 260 MW-31-89 1/18/07 0916 ND ND ND Q2139 260 MW-31-89 1/25/07 1125 ND ND ND Q2122 260 MW-31-89 2/1/07 0924 ND ND ND Q2238 260 MW-31-89 2/8/07 1547 ND ND ND Q2263 260 MW-31-89 2/9/07 1711 508.8 0.020 ND ND Q2299 260 MW-31-89 2/10/07 1022 ND ND ND Q2318 260 MW-31-89 2/11/07 0745 ND ND ND Q2348 260 MW-31-89 2/12/07 1020 508.3 958 ND ND Q2676 260 MW-31-89 2/13/07 1213 508.4 1,810 ND ND Q2704 260 MW-31-89 2/14/07 1027 508.5 1,680 ND ND Q2975 260 MW-31-89 2/15/07 1011 508.1 1,050 ND ND Q2989 260 MW-31-89 2/16/07 0943 508.3 715 ND ND Q3008 260 MW-31-89 2/17/07 0740 508.2 486 ND IND Q3027 260 MW-31-89 2/18/07 0746 508.9 367 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 6
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re OUL Station I Station Name Date/Time Fluorescein Results Eosine Results Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q3075 260 MW-31-89 2/19/07 0811 508.2 299 ND ND Q3105 260 MW-31-89 2/20/07 1012 508.7 222 ND ND Q3128 260 MW-31-89 2/21/07 1015 508.3 175 ND ND Q3646 260 MW-31-89 2/22/07 1325 508.3 148 ND ND Q3623 260 MW-31-89 2/23/07 0953 508.7 125 ND ND Q3535 260 MW-31-89 2/26/07 1018 508.4 99.7 ND ND Q3667 260 MW-31-89 2/27/07 1246 508.4 84.4 ND ND Q3878 260 MW-31-89 2/28/07 1252 508.4 77.3 ND ND Q4005 260 MW-31-89 3/1/07 1402 508.2 72 ND ND Q4033 260 MW-31-89 3/2/07 1042 508.3 62.6 ND ND Q4061 260 MW-31-89 3/5/07 1204 508.3 38.6 ND ND Q4061R 260 MW-31-89 3/5/07 1204 508.3 38.7 ND ND Q4269 260 MW-31-89 3/6/07 1143 508.1 38.4 ND
_ND Q4519 260 MW-31-89 3/7/07 1347 508.2 21.0 ND ND Q4645 260 MW-31-89 3/8/07 1025 508.5 23.3 ND ND Q4663 260 MW-31-89 3/9/07 1013 508.3 25.0 ND ND Q0836 270 MW-32-62 11/21/06 0815 ND ND ND Q1068 270 MW-32-62 11/28/06 0845 ND ND ND Q1297 270 MW-32-62 12/4/06 0902 ND ND ND Q1959 270 MW-32-62 1/18/07 1242 ND ND ND Q2141 270 MW-32-62 1/25/07 1229 ND ND ND Q2286 270 MW-32-62 2/7/07 1000 ND ND ND Q2239 270 MW-32-62 2/8/07 1430 508.3 23,800 ND ND Q2264 270 MW-32-62 2/9/07 1345 508.4 49,000 ND ND Q2301 270 MW-32-62 2/10/07 1103 508.3 14,500 ND ND Q2319 270 MW-32-62 2/11/07 0831 508.3 7,770 ND ND Q2349 270 MW-32-62 2/12/07 1049 508.4 3,950 ND ND Q2677 270 MW-32-62 2/13/07 1051 508.5 2,030 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 7
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental,inc.
I (OI TI,
~t2tinn
,*tgtinn Namw fl~ntp/ime Flmrnrp~u'pin Re;uI~t*
E~ndn Re~uult*
RWT Re Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q2705 270 MW-32-62 2/14/07 1047 508.3 1,380 ND ND Q2976 270 MW-32-62 2/15/07 1119 508.3 939 ND ND Q2990 270 MW-32-62 2/16/07 1038 508.5 733 ND ND Q3009 270 MW-32-62 2/17/07 0813 508.3 628 ND ND Q3028 270 MW-32-62 2/18/07 0820 509.0 498 ND ND Q3076 270 MW-32-62 2/19/07 0846 508.2 474 ND ND Q3106 270 MW-32-62 2/20/07 1057 508.7 378 ND ND Q3129 270 MW-32-62 2/21/07 1103 508.4 240 ND ND Q3647 270 MW-32-62 2/22/07 1345 508.5 238 ND ND Q3624 270 MW-32-62 2/23/07 1047 508.7 181 ND ND Q3536 270 MW-32-62 2/26/07 1039 508.3 115 ND ND Q3668 270 MW-32-62 2/27/07 1315 508.3 96.4 ND ND Q3879 270 MW-32-62 2/28/07 1316 508.5 89.3 ND ND Q3879R 270 MW-32-62 2/28/07 1316 508.5 87.9 ND ND Q4006 270 MW-32-62 3/1/07 1347 508.5 79 ND ND Q4034 270 MW-32-62 3/2/07 1328 508.4 123 ND ND Q4062 270 MW-32-62 3/5/07 1042 508.5 16.8 ND ND Q4270 270 MW-32-62 3/6/07 1350 508.7 1.60 ND ND Q4521 270 MW-32-62 3/7/07 1516 508.4 23.0 ND ND Q4646 270 MW-32-62 3/8/07 1050 508.5 30.2 ND ND Q4664 270 MW-32-62 3/9/07 1045 508.5 37.8 ND ND Q0837 280 MW-32-92 11/21/06 0820 ND ND ND Q1069 280 MW-32-92 11/28/06 0843 ND ND ND Q1298 280 MW-32-92 12/4/06 0913 ND ND ND Q1961 280 MW-32-92 1/18/07 1243 ND ND ND Q2142 280 MW-32-92 1/25/07 1231 ND ND ND Q2287 280 MW-32-92 2/7/07 0955 ND ND ND Q2241 280 MW-32-92 2/8/07 1430 508.3 24,300 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 8
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, inc.
RWT Re OTI J S~tatinn S~tation Name Date/Time Fluorescein Results Eosine Results Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q2265 280 MW-32-92 2/9/07 1355 508.5 4,730 ND ND Q2302 280 MW-32-92 2/10/07 1105 508.4 15,100 ND ND Q2321 280 MW-32-92 2/11/07 0834 508.3 7,810 ND ND Q2350 280 MW-32-92 2/12/07 1052 508.2 4,130 ND ND Q2678 280 MW-32-92 2/13/07 1025 508.4 2,100 ND ND Q2706 280 MW-32-92 2/14/07 1053 508.5 1,380 ND ND Q2977 280 MW-32-92 2/15/07 1120 508.3 951 ND ND Q2991 280 MW-32-92 2/16/07 1042 508.5 710 ND ND Q3010 280 MW-32-92 2/17/07 0816 508.4 643 ND ND Q3029 280 MW-32-92 2/18/07 0822 509.0 560 ND ND Q3077 280 MW-32-92 2/19/07 0832 508.2 472 ND ND Q3107 280 MW-32-92 2/20/07 1054 508.7 398 ND ND Q3130 280 MW-32-92 2/21/07 1115 508.3 340 ND ND Q3648 280 MW-32-92 2/22/07 1350 508.5 240 ND ND Q3625 280 MW-32-92 2/23/07 1025 508.7 182 ND ND Q3537 280 MW-32-92 2/26/07 1043 508.4 113 ND ND Q3669 280 MW-32-92 2/27/07 1320 508.5 95.7 ND ND Q3881 280 MW-32-92 2/28/07 1320 508.3 94.3 ND ND Q4007 280 MW-32-92 3/1/07 1331 508.3 83.8 ND ND Q4035 280 MW-32-92 3/2/07 1326 508.1 76.3 ND ND Q4063 280 MW-32-92 3/5/07 1044 508.5 70.8 ND ND Q4271 280 MW-32-92 3/6/07 1351 508.6 49.7 ND ND Q4522 280 MW-32-92 3/7/07 1526 508.3 19.9 ND ND Q4647 280 MW-32-92 3/8/07 1051 508.4 14.7 ND ND Q4665 280 MW-32-92 3/9/07 1047 508.4 19.4 ND ND Q0838 290 MW-32-140 11/21/06 0825 ND ND ND Q1070 290 MW-32-140 11/28/06 0833 ND I
ND ND Q1299 290 MW-32-140 12/4/06 0917 ND I
ND ND f:\\docs\\coa\\GZA.xls 3/19/2007 9
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
OUL Station Station Name Date/Time Fluorescein Results Eosine Results RWT Re Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q1962 290 MW-32-140 1/18/07 1244 ND ND ND Q2143 290 MW-32-140 1/25/07 1232 ND ND ND Q2288 290 MW-32-140 2/7/07 0952 ND ND ND Q2242 290 MW-32-140 2/8/07 1430 510.5 0.051 ND ND Q2242R 290 MW-32-140 2/8/07 1430 510.2 0.050 ND ND Q2266 290 MW-32-140 2/9/07 1415 ND ND ND Q2303 290 MW-32-140 2/10/07 1119 508.3 15,300 ND ND Q2322 290 MW-32-140 2/11/07 0845 508.3 8,210 ND ND Q2351 290 MW-32-140 2/12/07 1112 508.3 4,240 ND ND Q2679 290 MW-32-140 2/13/07 1032 508.5 2,280 ND ND Q2707 290 MW-32-140 2/14/07 1056 508.5 1,490 ND ND Q2978 290 MW-32-140 2/15/07 1135 508.2 1,360 ND ND Q2992 290 MW-32-140 2/16/07 1050 508.3 744 ND ND Q3011 290 MW-32-140 2/17/07 0825 508.3 660 ND ND Q3030 290 MW-32-140 2/18/07 0833 509.0 583 ND ND Q3078 290 MW-32-140 2/19/07 0849 508.2 492 ND ND Q3108 290 MW-32-140 2/20/07 1110 508.3 373 ND ND Q3131 290 MW-32-140 2/21/07 1141 508.4 332 ND ND Q3649 290 MW-32-140 2/22/07 1355 508.5 228 ND ND Q3626 290 MW-32-140 2/23/07 1031 508.7 190 ND ND Q3538 290 MW-32-140 2/26/07 1048 508.3 113 ND ND Q3538R 290 MW-32-140 2/26/07 1048 508.4 114 ND ND Q3670 290 MW-32-140 2/27/07 1331 508.3 94.5 ND ND Q3882 290 MW-32-140 2/28/07 1336 508.5 92.2 ND ND Q4008 290 MW-32-140 3/1/07 1335 508.3 87.6 ND ND Q4036 290 MW-32-140 3/2/07 1311 508.4 69.5 ND ND Q4064 290 MW-32-140 3/5/07 1047 508.3 74.9 ND ND Q4272 290 MW-32-140 3/6/07 1354 508.3 90.3 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 10
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re
- 0111, 5~tatinn Station Name Da~te/Time Fhlonreaein Re~uult*
Fndnne Reunlt'*
Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q4523 290 MW-32-140 3/7/07 1522 508.6 88.2 ND ND Q4648 290 MW-32-140 3/8/07 1052 509.1 86.4 ND ND Q4666 290 MW-32-140 3/9/07 1055 508.9 90.8 ND ND Q0839 300 MW-32-160 11/21/06 0820 ND ND ND Q1071 300 MW-32-160 11/28/06 0836 ND ND ND Q1301 300 MW-32-160 12/4/06 0920 ND ND ND Q1963 300 MW-32-160 1/18/07 1245 ND ND ND Q2144 300 MW-32-160 1/25/07 1308 ND ND ND Q2289 300 MW-32-165 2/7/07 0948 ND ND ND Q2243 300 MW-32-165 2/8/07 1430 ND ND ND Q2267 300 MW-32-165' 2/9/07 1420 ND ND ND Q2304 300 MW-32-165 2/10/07 1122 508.3 36.9 ND ND Q2323 300 MW-32-165 2/11/07 0850 508.2 1,650 ND ND Q2352 300 MW-32-165 2/12/07 1118 508.3 3,850 ND ND Q2352R 300 MW-32-165 2/12/07 1118 508.4 3,840 ND ND Q2681 300 MW-32-165 2/13/07 1033 508.5 4,160 ND ND Q2708 300 MW-32-165 2/14/07 1056 508.3 3,620 ND ND Q2708R 300 MW-32-165 2/14/07 1056 508.3 3,620 ND ND Q2979 300 MW-32-165 2/15/07 1129 508.2 2,650 ND ND Q2993 300 MW-32-165 2/16/07 1052 508.4 1,970 ND ND Q2993R 300 MW-32-165 2/16/07 1052 508.5 1,990 ND ND Q3012 300 MW-32-165 2/17/07 0827 508.3 1,590 ND ND Q3031 300 MW-32-165 2/18/07 0836 509.0 1,270 ND ND Q3079 300 MW32-165 2/19/07 0854 508.1 1,120 ND ND Q3109 300 MW-32-165 2/20/07 1116 508.3 926 ND ND Q3132 300 MW-32-165 2/21/07 1145 508.3 682 ND ND Q3650 300 MW-32-165 2/22/07 1400 508.3 605 ND ND Q3627 300 MW-32-165 2/23/07 1034 508.7 489 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 11
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re OUL Station Station Name Date/Time Fluorescein Results Eosine Results Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q3539 300 MW-32-165 2/26/07 1054 508.5 121 ND ND Q3671 300 MW-32-165 2/27/07 1343 508.3 97.7 ND ND Q3883 300 MW-32-165 2/28/07 1342 508.3 92.9 ND ND Q4009 300 MW-32-165 3/1/07 1341 508.3 87.8 ND ND Q4037 300 MW-32-165 3/2/07 1334 508.3 72.4 ND ND Q4065 300 MW-32-165 3/5/07 1049 508.5 98.2 ND ND Q4273 300 MW-32-165 3/6/07 1353 508.6 110 ND ND Q4524 300 MW-32-165 3/7/07 1515 508.6 102 ND ND Q4649 300 MW-32-165 3/8/07 1058 508.7 102 ND ND Q4667 300 MW-32-165 3/9/07 1057 508.9 97.3 ND ND Q0841 310 MW-32-197 11/21/06 0820 ND ND ND Q1072 310 MW-32-197 11/28/06 0840 ND ND ND Q1302 310 MW-32-197 12/4/06 0928 ND ND ND Q1964 310 MW-32-197 1/18/07 1246 ND ND ND Q2145 310 MW-32-197 1/25/07 1310 ND ND ND Q2145R 310 MW-32-197 1/25/07 1310 ND ND ND Q2290 310 MW-32-196 2/7/07 0945 ND ND ND Q2244 310 MW-32-196 2/8/07 1430 ND ND ND Q2268 310 MW-32-196 2/9/07 1423 ND ND ND Q2305 310 MW-32-196 2/10/07 1123 ND ND ND Q2324 310 MW-32-196 2/11/07 0852 ND ND ND Q2353 310 MW-32-196 2/12/07 1119 ND ND ND Q2682 310 MW-32-196 2/13/07 1057 505.6
- 0.026 ND ND Q2709 310 MW-32-196 2/14/07 1057 508.5 1.41 ND ND Q2981 310 MW-32-196 2/15/07 1131 508.1 16.0 ND ND Q2994 310 MW-32-196 2/16/07 1053 508.7 74.5 ND ND Q3013 310 MW-32-196 2/17/07 0829 508.1 143 ND IND Q3032 310 MW-32-196 2/18/07 0839 509.0 2.41 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 12
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re OUL Station Station Name Date/Time Fluore~cein Re~iiIIs Eosine Resuts~t Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q3081 310 MW-32-196 2/19/07 0855 508.3 417 ND ND Q3110 310 MW-32-196 2/20/07 1122 508.4 385 ND ND Q3133 310 MW-32-196 2/21/07 1146 508.3 525 ND ND Q3651 310 MW-32-196 2/22/07 1405 508.4 581 ND ND Q3628 310 MW-32-196 2/23/07 1041 508.7 569 ND ND Q3541 310 MW-32-196 2/26/07 1056 508.3 621 ND ND Q3672 310 MW-32-196 2/27/07 1344 509 558 ND ND Q3884 310 MW-32-196 2/28/07 1343 508.3 543 ND ND Q4010 310 MW-32-196 3/1/07 1343 508.4 488 ND ND Q4038 310 MW-32-196 3/2/07 1334 508.2 380:
ND ND Q4066 310 MW-32-196 3/5/07 1050 508.2 326 ND ND Q4274 310 MW-32-196 3/6/07 1356 508.4 297 ND ND Q4525 310 MW-32-196 3/7/07 1529 508.5 210 ND ND Q4650 310 MW-32-196 3/8/07 1059 508.7 168 ND ND Q4668 310 MW-32-196 3/9/07 1058 508.9 159 ND ND Q2284 320 MW-33 2/8/07 0842 507.2
- 0.055 ND ND Q3978 320 MW-33 2/26/07 0915 508.9 2.60 ND ND Q4629 320 MW-33 3/2/07 0853 508.3 6.01 ND ND Q4630 320 MW-33 3/5/07 0857 508.3 6.55 ND ND Q4631 380 MW-37-22 3/2/07 0804 508.3 1.06 ND ND Q4632 380 MW-37-22 3/5/07 0912 508.4 3.52 ND IND Q4024 441 MW-39A (70')
3/1/07 1424 ND ND ND Q4025 451 MW-39B (87')
3/1/07 1430 ND ND ND Q4026 461 MW-39C (104')
3/1/07 1435 ND ND ND Q4027 471 MW-39D (141')
3/1/07 1442 ND ND ND Q4028 472 MW-39E (197')
3/1/07 1450 ND ND ND Q4613 480 MW-42-51 3/1/07 1510 508.7 1.46 ND I
ND Q4614 480 MW-42-51 3/2/07 1332 508.4 0.667 ND I
ND f:\\docs\\coa\\GZA.xls 3/19/2007 13
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
IRWT Re OTIL Station Station Name Date/Time Flnore~cein Resuult*
F~orine Resnult' Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q4615 480 MW-42-51 3/5/07 1345 508.0 0.208 ND ND Q3359 490 MW-42-79 2/15/07 0830 508.8 0.157 ND ND Q4616 490 MW-42-79 3/1/07 1515 508.5 0.101 ND ND Q4617 490 MW-42-79 3/2/07 1338 508.7 0.155 ND ND Q4618 490 MW-42-79 3/5/07 1350 508.4 0.681 ND ND Q2291 560 MW-49-42 2/10/07 0954 ND ND ND Q2123 611 MW-52-32 2/2/07 1119 ND ND ND Q2245 611 MW-52-32 2/8/07 1423 ND ND ND Q2269 611 MW-52-32 2/9/07 0912 ND ND ND Q2306 611 MW-52-32 2/10/07 1310 ND ND ND Q2325 611 MW-52-32 2/11/07 1503 ND ND ND Q2354 611 MW-52-32 2/12/07 1425 ND ND ND Q2683 611 MW-52-32 2/13/07 1500 ND ND ND Q2710 611 MW-52-32 2/14/07 1350 ND ND ND Q2982 611 MW-52-32 2/15/07 1403 ND ND ND Q2995 611 MW-52-32 2/16/07 1015 ND ND ND Q3014 611 MW-52-32 2/17/07 1254 ND ND ND Q3014R 611 MW-52-32 2/17/07 1254 ND ND ND Q3033 611 MW-52-32 2/18/07 1218 ND ND ND Q3082 611 MW-52-32 2/19/07 1352 ND ND ND Q3111 611 MW-52-32 2/20/07 1315 ND ND ND Q3134 611 MW-52-32 2/21/07 1335 ND ND ND Q3652 611 MW-52-32 2/22/07 1035 ND ND ND Q3629 611 MW-52-32 2/23/07 0945 ND ND ND Q3542 611 MW-52-32 2/26/07 1340 ND ND ND Q3673 611 MW-52-32 2/27/07 0820 ND ND ND Q3885 611 MW-52-32 2/28/07 0902 ND ND ND Q4011 611 MW-52-32 3/1/07 0931 ND IND IND f:\\docs\\coa\\GZA.xls 3/19/2007 14
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re OULL Station Station Name Date/Time Fluorescein Results Eosine Results Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q4039 611 MW-52-32 3/2/07 0920 ND ND ND Q4039R 611 MW-52-32 3/2/07 0920 ND ND ND Q4067 611 MW-52-32 3/5/07 1430 ND ND ND Q4275 611 MW-52-32 3/6/07 0940 ND ND ND Q4526 611 MW-52-32 3/7/07 1354 ND ND ND Q4526R 611 MW-52-32 3/7/07 1354 ND ND ND Q4651 611 MW-52-32 3/8/07 0949 ND ND ND Q2124 621 MW-52-69 2/2/07 1123 ND ND ND Q2246 621 MW-52-69 2/8/07 1328 ND ND ND Q2270 621 MW-52-69 2/9/07 0854 ND ND ND Q2307 621 MW-52-69 2/10/07 1310 ND ND ND Q2326 621 MW-52-69 2/11/07 1458 ND ND ND Q2355 621 MW-52-69 2/12/07 1427 ND ND ND Q2684 621 MW-52-69 2/13/07 1502 ND ND ND Q2711 621 MW-52-69 2/14/07 1351 ND ND ND Q2983 621 MW-52-69 2/15/07 1406 ND ND ND Q2996 621 MW-52-69 2/16/07 1035 ND ND ND Q3015 621 MW-52-69 2/17/07 1255 ND ND ND Q3034 621 MW-52-69 2/18/07 1219 ND ND ND Q3083 621 MW-52-69 2/19/07 1356 ND ND ND Q3112 621 MW-52-69 2/20/07 1313 ND ND ND Q3135 621 MW-52-69 2/21/07 1336 ND ND ND Q3653 621 MW-52-69 2/22/07 1040 ND ND ND Q3630 621 MW-52-69 2/23/07 0947 ND ND ND Q3543 621 MW-52-69 2/26/07 1342 ND ND ND Q3674 621 MW-52-69 2/27/07 0822 ND ND ND Q3886 621 MW-52-69 2/28/07 0904 ND ND IND Q4012 621 MW-52-69 3/1/07 0934 ND IND IND f:\\docs\\coa\\GZA.xls 3/19/2007 15
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re OUIL Station Station Name Date/Time Fluorescein Results Eosine Results Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q4041 621 MW-52-69 3/2/07 0925 ND ND ND Q4068 621 MW-52-69 3/5/07 1433 ND ND ND Q4276 621 MW-52-69 3/6/07 0941 ND ND ND Q4527 621 MW-52-69 3/7/07 1358 ND ND ND Q4652 621 MW-52-69 3/8/07 0957 ND ND ND Q2125 626 MW-52-99 2/2/07 1126 ND ND ND Q2247 626 MW-52-99 2/8/07 1330 ND ND ND Q2271 626 MW-52-99 2/9/07 0856 ND ND ND Q2308 626 MW-52-99 2/10/07 1330 ND ND ND Q2327 626 MW-52-99 2/11/07 1437 ND ND ND Q2356 626 MW-52-99 2/12/07 1427 ND ND ND Q2685 626 MW-52-99 2/13/07 1503 ND ND ND Q2712 626 MW-52-99 2/14/07 1352 ND ND ND Q2984 626 MW-52-99 2/15/07 1405 ND ND ND Q2997 626 MW-52-99 2/16/07 1040 ND ND ND Q3016 626 MW-52-99 2/17/07 1257 ND ND ND Q3035 626 MW-52-99 2/18/07 1220 ND ND ND Q3035R 626 MW-52-99 2/18/07 1220 ND ND ND Q3084 626 MW-52-99 2/19/07 1354 ND ND ND Q3113 626 MW-52-99 2/20/07 1319 ND ND ND Q3136 626 MW-52-99 2/21/07 1337 ND ND ND Q3654 626 MW-52-99 2/22/07 1045 ND ND ND Q3631 626 MW-52-99 2/23/07 0950 ND ND ND Q3544 626 MW-52-99 2/26/07 1344 ND ND ND Q3675 626 MW-52-99 2/27/07 0822 ND ND ND Q3887 626 MW-52-99 2/28/07 0904 ND ND ND Q4013 626 MW-52-99 3/1/07 0935 ND ND ND Q4042 626 MW-52-99 3/2/07 0926 ND
_ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 16
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re OUJL Station Station Name Date/Time Fluorescein Results Eosine Results Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q4069 626 MW-52-99 3/5/07 1436 ND ND ND Q4277 626 MW-52-99 3/6/07 0946 ND ND ND Q4528 626 MW-52-99 3/7/07 1359 ND ND ND Q4653 626 MW-52-99 3/8/07 1002 ND ND ND Q2126 631 MW-52-137 2/2/07 1130 ND ND ND Q2248 631 MW-52-137 2/8/07 1405 ND ND ND Q2272 631 MW-52-137 2/9/07 0934 ND ND ND Q2309 631 MW-52-137 2/10/07 1350 ND ND ND Q2328 631 MW-52-137 2/11/07 1444 ND ND ND Q2357 631 MW-52-137 2/12/07 1429 ND ND ND Q2686 631 MW-52-137 2/13/07 1504 ND ND ND Q2713 631 MW-52-137 2/14/07 1353 ND ND ND Q2985 631 MW-52-137 2/15/07 1409 ND ND ND Q2998 631 MW-52-137 2/16/07 1025 ND ND ND Q3017 631 MW-52-137 2/17/07 1301 ND ND ND Q3036 631 MW-52-137 2/18/07 1225 ND ND ND Q3085 631 MW-52-137 2/19/07 1357 ND ND ND Q3114 631 MW-52-137 2/20/07 1324 ND ND ND Q3137 631 MW-52-137 2/21/07 1342 ND ND ND Q3655 631 MW-52-137 2/22/07 1050 ND ND ND Q3632 631 MW-52-137 2/23/07 0955 ND ND ND Q3545 631 MW-52-137 2/26/07 1347 ND ND ND Q3676 631 MW-52-137 2/27/07 0826 ND ND ND Q3888 631 MW-52-137 2/28/07 0908 ND ND ND Q4014 631 MW-52-137 3/1/07 0938 ND ND ND Q4043 631 MW-52-137 3/2/07 0927 ND ND ND Q4070 631 MW-52-137 3/5/07 1439 ND IND I
ND Q4278 631 MW-52-137 3/6/07 0947 ND IND ND f:\\docs\\coa\\GZA.xls 3/19/2007 17
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re OUIL St5ition S~tation Name Daiti4T~ime Flnnre~eein Resnl~t*
F~inen Recnlt'*
Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q4529 631 MW-52-137 3/7/07 1400 ND ND ND Q4654 631 MW-52-137 3/8/07 1009 ND ND ND Q2127 636 MW-52-194 2/2/07 1131 ND ND ND Q2249 636 MW-52-194 2/8/07 1417 ND ND ND Q2273 636 MW-52-194 2/9/07 0900 ND ND ND Q2310 636 MW-52-194 2/10/07 1335 ND ND ND Q2329 636 MW-52-194 2/11/07 1445 ND ND ND Q2358 636 MW-52-194 2/12/07 1431 ND ND ND Q2687 636 MW-52-194 2/13/07 1504 ND ND ND Q2714 636 MW-52-194 2/14/07 1354 ND ND ND Q2986 636 MW-52-194 2/15/07 1410 ND ND ND Q2999 636 MW-52-194 2/16/07 1020 ND ND ND Q3018 636 MW-52-194 2/17/07 1303 ND ND ND Q3037 636 MW-52-194 2/18/07 1227 ND ND ND Q3086 636 MW-52-194 2/19/07 1401 ND ND ND Q3115 636 MW-52-194 2/20/07 1328 ND ND ND Q3138 636 MW-52-194 2/21/07 1344 ND ND ND Q3656 636 MW-52-194 2/22/07 1055 ND ND ND Q3633 636 MW-52-194 2/23/07 1000 ND ND ND Q3546 636 MW-52-194 2/26/07 1348 ND ND ND Q3677 636 MW-52-194 2/27/07 0829 ND ND ND Q3889 636 MW-52-194 2/28/07 0912 ND ND ND Q4015 636 MW-52-194 3/1/07 0940 ND ND ND Q4044 636 MW-52-194 3/2/07 0929 ND ND ND Q4071 636 MW-52-194 3/5/07 1442 ND ND ND Q4279 636 MW-52-194 3/6/07 0950 ND ND ND Q4530 636 MW-52-194 3/7/07 1401 ND IND
_ND Q4655 636 MW-52-194 3/8/07 1019 ND IND IND f:\\docs\\coa\\GZA.xls 3/19/2007 18
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re 0111I.
5~t2tinn 5Station Name 1batp/Timp Fhuure~eein Re~uult*
Fn~ine Rec~ult*
Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q2945 640 MW-52-12 2/11/07 1408 ND ND ND Q2232 650 MW-53-80 2/9/07 0950 ND ND ND Q3092 650 MW-53-80 2/14/07 1121 508.7 0.542 ND ND Q3358 650 MW-53-80 2/16/07 1010 508.4 2.43 ND ND Q3364 650 MW-53-80 2/19/07 1105 508.7 4.15 ND ND Q3365 650 MW-53-80 2/21/07 1155 508.7 5.15 ND ND Q4256 650 MW-53-80 2/23/07 1145 508.7 4.57 ND ND Q3982 650 MW-53-80 2/26/07 1329 508.8 5.17 ND ND Q4257 650 MW-53-80 2/28/07 1420 508.7 4.46 ND ND Q4633 650 MW-53-80 3/2/07 1311 508.5 0.159 ND ND Q4634 650 MW-53-80 3/5/07 1328 508.4 0.049 ND ND Q2233 660 MW-53-120 2/9/07 0951 ND ND ND Q2128 671 MW-54-40 2/1/07 1320 ND ND ND Q2250 671 MW-54-40 2/8/07 1510 ND ND ND Q2274 671 MW-54-40 2/9/07 1125 ND ND ND Q2311 671 MW-54-40 2/10/07 1457 ND ND ND Q2311R 671 MW-54-40 2/10/07 1457 ND ND ND Q2330 671 MW-54-40 2/11/07 1345 ND ND ND Q2359 671 MW-54-40 2/12/07 1330 ND ND ND Q2688 671 MW-54-40 2/13/07 1345 ND ND ND Q2715 671 MW-54-40 2/14/07 1245 ND ND ND Q3001 671 MW-54-40 2/16/07 1120 ND ND ND Q3019 671 MW-54-40 2/17/07 1159 ND ND ND Q3038 671 MW-54-40 2/18/07 1126 ND ND ND Q3087 671 MW-54-40 2/19/07 1313 ND ND ND Q3116 671 MW-54-40 2/20/07 1244 ND ND ND Q3139 671 MW-54-40 2/21/07 1420 ND I
ND IND Q3657 671 MW-54-40 2/22/07 1135 505.2 **
0.038 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 19
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results 1, Water Samples.
GZA Environmental, Inc.
RWT Re 0111.
~t2tifln I
,*tatifln Name TaeTitf~mp Fjunrp~'pin Ro~uu1t~
findn Re~uult*
Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q3634 671 MW-54-40 2/23/07 0835 505.4 **
0.114 ND ND Q3547 671 MW-54-40 2/26/07 1259 506.4 **
0.335 ND ND Q3678 671 MW-54-40 2/27/07 0946 507.2 **
0.377 ND ND Q3890 671 MW-54-40 2/28/07 0948 506.9 **
0.526 ND ND Q4016 671 MW-54-40 3/1/07 0827 507.1 **
0.526 ND
_ND Q4045 671 MW-54-40 3/2/07 1045 507.4 **
0.859 ND
_ND Q4072 671 MW-54-40 3/5/07 1530 507.7 **
0.953 ND ND Q4281 671 MW-54-40 3/6/07 0831 507.8 **
0.837 ND ND Q4669 671 MW-54-40 3/9/07 1435 507.7 **
0.755 ND ND Q2129 681 MW-54-66 2/1/07 1335 ND ND ND Q2251 681 MW-54-66 2/8/07 1511 ND ND ND Q2275 681 MW-54-66 2/9/07 1128 ND ND ND Q2312 681 MW-54-66 2/10/07 1501 ND ND ND Q2331 681 MW-54-66 2/11/07 1348 ND ND ND Q2331R 681 MW-54-66 2/11/07 1348 ND ND ND Q2361 681 MW-54-66 2/12/07 1332 ND ND ND Q2689 681 MW-54-66 2/13/07 1346 ND ND ND Q2716 681 MW-54-66 2/14/07 1246 ND ND ND Q3002 681 MW-54-66 2/16/07 1125 ND ND ND Q3021 681 MW-54-66 2/17/07 1203 ND ND ND Q3039 681 MW-54-66 2/18/07 1128 ND ND ND Q3088 681 MW-54-66 2/19/07 1313 ND ND ND Q3117 681 MW-54-66 2/20/07 1245 ND ND ND Q3141 681 MW-54-66 2/21/07 1421 ND ND ND Q3658 681 MW-54-66 2/22/07 1140 505.2 **
0.068 ND ND Q3635 681 MW-54-66 2/23/07 0840 505.2 **
0.074 ND IND Q3548 681 MW-54-66 2/26/07 1300 506.8 **
0.212 ND IND Q3679 681 MW-54-66 2/27/07 0942 507.0 **
0.250 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 20
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
IRWT Re
- 0111,
~tntinn
- qtatinn Name Thite/Time Fhjunrp~gpin Re~uult*
F*ine Re*nlt.*
Recovered Peak am Conc. ppb Peak am Conc. ppb Peak nm Q3679R 681 MW-54-66 2/27/07 0942 507.1 **
0.251 ND ND Q3891 681 MW-54-66 2/28/07 0949 507.1 **
0.341 ND ND Q4017 681 MW-54-66 3/1/07 0828 507.0 **
0.345 ND ND Q4046 681 MW-54-66 3/2/07 1046 507.3 **
0.525 ND ND Q4073 681 MW-54-66 3/5/07 1533 507.8 **
0.645 ND ND Q4282 681 MW-54-66 3/6/07 0832 507.7 **
0.526 ND ND Q4670 681 MW-54-66 3/9/07 1436 507.6 **
0.534 ND ND Q2130 691 MW-54-132 2/1/07 1337 ND ND ND Q2130R 691 MW-54-132 2/1/07 1337 ND ND ND Q2252 691 MW-54-132 2/8/07 1519 ND ND ND Q2276 691 MW-54-132 2/9/07 1135 ND ND ND Q2313 691 MW-54-132 2/10/07 1503 ND ND ND Q2332 691 MW-54-132 2/11/07 1352 ND ND ND Q2362 691 MW-54-132 2/12/07 1337 ND ND ND Q2690 691 MW-54-132 2/13/07 1350 ND ND ND Q2717 691 MW-54-132 2/14/07 1248 ND ND ND Q3003 691 MW-54-132 2/16/07 1128 ND ND ND Q3022 691 MW-54-132 2/17/07 1210 ND ND ND Q3041 691 MW-54-132 2/18/07 1133 ND ND ND Q3089 691 MW-54-132 2/19/07 1317 ND ND ND Q3118 691 MW-54-132 2/20/07 1249 ND ND ND Q3118R 691 MW-54-132 2/20/07 1249 ND ND ND Q3142 691 MW-54-132 2/21/07 1426 ND ND ND Q3142R 691 MW-54-132 2/21/07 1426 ND ND ND Q3659 691 MW-54-132 2/22/07 1145 504.4 **
0.030 ND ND Q3659R 691 MW-54-132 2/22/07 1145 505.6 **
0.037 ND ND Q3636 691 MW-54-132 2/23/07 0845 506.2 **
0.063 ND ND Q3549 691 MW-54-132 2/26/07 1305 506.6 **
0.190 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 21
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re OUL Station Station Name Date/Time Fluorescein Results Eosine Results Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q3681 691 MW-54-132 2/27/07 0949 506.6 **
0.173 ND ND Q3892 691 MW-54-132 2/28/07 0954 506.9 **
0.309 ND ND Q4018 691 MW-54-132 3/1/070833 507.0**
0.317 ND ND Q4047 691 MW-54-132 3/2/07 1052 507.3 **
0.440 ND ND Q4074 691 MW-54-132 3/5/07 1535 507.8 **
0.631 ND ND Q4283 691 MW-54-132 3/6/07 0837 508.2 0.509 ND ND Q4671 691 MW-54-132 3/9/07 1440 507.6 **
0.479 ND 573.8 Q2131 701 MW-54-163 2/1/07 1339 ND ND ND Q2253 701 MW-54-163 2/8/07 1520 ND ND ND Q2277 701 MW-54-163 2/9/07 1137 ND ND ND Q2314 701 MW-54-163 2/10/07 1504 ND ND ND Q2333 701 MW-54-163 2/11/07 1354 ND ND ND Q2363 701 MW-54-163 2/12/07 1341 ND ND ND Q2691 701 MW-54-163 2/13/07 1352 ND ND ND Q2718 701 MW-54-163 2/14/07 1249 ND ND ND Q3004 701 MW-54-163 2/16/07 1130 ND ND ND Q3023 701 MW-54-163 2/17/07 1211 ND ND ND Q3042 701 MW-54-163 2/18/07 1134 ND ND ND Q3090 701 MW-54-163 2/19/07 1318 ND ND ND Q3119 701 MW-54-163, 2/20/07 1251 ND ND ND Q3143 701 MW-54-163 2/21/07 1426 ND ND ND Q3661 701 MW-54-163 2/22/07 1150 504.2**
0.031 ND ND Q3637 701 MW-54-163 2/23/07 0848 506.6 **
0.060 ND ND Q3550 701 MW-54-163 2/26/07 1306 506.6 **
0.185 ND ND Q3682 701 MW-54-163 2/27/07 0951 507.5 **
0.123 ND ND Q3893 701 MW-54-163 2/28/07 0955 507.0 **
0.289 ND ND Q4019 701 MW-54-163 3/1/07 0834 507.3**
0.313 ND IND Q4019R 701 MW-54-163 3/1/07 0834 507.3 **
0.308 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 22
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
IRWT Re OULy Station Station Nalme Date/Time Flnore*cein Re.*nlt*
Eo,*ine Re*nlt*
Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q4048 701 MW-54-163 3/2/07 1053 507.3 **
0.425 ND ND Q4075 701 MW-54-163 3/5/07 1540 507.7 **
0.634 ND ND Q4284 701 MW-54-163 3/6/07 0838 507.8**
0.553 ND ND Q4672 701 MW-54-163 3/9/07 1441 507.7 **
0.478 ND ND Q2132 702 MW-54-200 2/1/07 1340 ND ND ND Q2254 702 MW-54-200 2/8/07 1530 ND ND ND Q2278 702 MW-54-200 2/9/07 1142 ND ND ND Q2315 702 MW-54-200 2/10/07 1505 ND ND ND Q2334 702 MW-54-200 2/11/07 1345 ND ND ND Q2364 702 MW-54-200 2/12/07 1337 ND ND ND Q2692 702 MW-54-200 2/13/07 1353 ND ND ND Q2719 702 MW-54-200 2/14/07 1250 ND ND ND Q3005 702 MW-54-200 2/16/07 1133 ND ND ND Q3024 702 MW-54-200 2/17/07 1212 ND ND ND Q3043 702 MW-54-200 2/18/07 1135 ND ND ND Q3043R 702 MW-54-200 2/18/07 1135 ND ND ND Q3091 702 MW-54-200 2/19/07 1320 ND ND ND Q3121 702 MW-54-200 2/20/07 1253 ND ND ND Q3144 702 MW-54-200 2/21/07 1427 ND ND ND Q3662 702 MW-54-200 2/22/07 1155 505.4 **
0.024 ND ND Q3638 702 MW-54-200 2/23/07 0850 504.8 **
0.026 ND ND Q3638R 702 MW-54-200 2/23/07 0850 504.3 **
0.024 ND ND Q3551 702 MW-54-200 2/26/07 1306 506.2 **
0.148 ND ND Q3683 702 MW-54-200 2/27/07 0952 506.2 **
0.104 ND ND Q3894 702 MW-54-200 2/28/07 0956 506.7 **
0.238 ND ND Q4021 702 MW-54-200 3/1/07 0835 507.0 **
0.252 ND ND Q4049 702 MW-54-200 3/2/07 1054 507.2 **
0.353 ND I
ND Q4076 702 MW-54-200 3/5/07 1545 508.0 0.704 ND I
ND f:\\docs\\coa\\GZA.xls 3/19/2007 23
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
0111.
S~tatinn 5Station Name flate/Time Fluonrescein Resuilts Eosine Results RWT Re Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q4285 702 MW-54-200 3/6/07 0839 508.1 0.647 ND ND Q4673 702 MW-54-200 3/9/07 1443 507.8 **
0.49 ND ND Q4673R 702 MW-54-200 3/9/07 1443 508.1 0.478 ND ND Q4619 710 MW-55-24 3/1/07 0855 507.6 **
0.048 ND ND Q4619R 710 MW-55-24 3/1/07 0855 508.1 0.042 ND ND Q4621 720 MW-55-34 3/1/07 0851 506.6 **
0.022 ND ND Q4622 730 MW-55-54 3/1/07 0847 508.3 0.281 ND ND Q2292 800 MW-58-26 2/10/07 1053 508.4
- 0.023 ND ND Q2115 849 MW-60 (20')
2/1/07 1037 ND ND ND Q2257 849 MW-60 (20')
2/8/07 0850 ND ND ND Q2230 849 MW-60 (20')
2/9/07 1000 ND ND ND Q2293 849 MW-60 (20')
2/10/07 0800 ND ND ND Q2338 849 MW-60 (20')
2/11/07 0735 ND ND ND Q2339 849 MW-60 (20')
2/12/07 0833 ND ND ND Q2693 849 MW-60 (20')
2/13/07 0820 ND ND ND Q2697 849 MW-60 (20')
2/14/07 0950 ND ND ND Q3201 849 MW-60 (20')
2/16/07 1007 ND ND ND Q3196 849 MW-60 (20')
2/19/07 0840 ND ND ND Q3147 849 MW-60 (20')
2/21/07 1058 ND ND ND Q3615 849 MW-60 (20')
2/23/07 1018 ND ND ND Q3552 849 MW-60 (20')
2/26/07 0923 ND ND ND Q3897 849 MW-60 (20')
2/28/07 1108 ND ND ND Q4052 849 MW-60 (20')
3/2/07 1358 ND ND ND Q4083 849 MW-60 (20')
3/5/07 0933 ND ND ND Q4541 849 MW-60 (20')
3/7/07 1120 ND ND ND Q4676 849 MW-60 (20')
3/9/07 0836 ND ND ND Q4676R 849 MW-60 (20')
3/9/07 0836 ND IND ND Q2134 909 MW-66 (48')
2/1/07 0946 ND ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 24
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
IRWT Re Al IT.
~t2tiflfl I
- tntinn Nanme flatp/Time Flunorepein Re~ault.
To~nen Re~unlt*
Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q2256 909 MW-66 (48')
2/8/07 1300 ND ND ND Q2281 909 MW-66 (48')
2/9/07 0954 ND ND ND Q2337 909 MW-66 (48')
2/10/07 0755 ND ND ND Q2296 909 MW-66 (48')
2/11/07 0801 ND ND ND Q2343 909 MW-66 (48')
2/12/07 0936 ND ND ND Q2696 909 MW-66 (48')
2/13/07 0943 ND ND ND Q2701 909 MW-66 (48')
2/14/07 0946 ND ND ND Q3204 909 MW-66 (48')
2/16/07 1310 ND ND ND Q3199 909 MW-66 (48')
2/19/07 0841 ND ND ND Q3150 909 MW-66 (48')
2/21/07 0759 ND ND ND Q3690 909 MW-66 (48')
2/23/07 0915 ND ND ND Q3555 909 MW-66 (48')
2/26/07 1018 ND ND ND Q3901 909 MW-66 (48')
2/28/07 1040 509.2
- 0.025 ND ND Q4055 909 MW-66 (48')
3/2/07 1023 510.0
- 0.055 ND ND Q4082 909 MW-66 (48')
3/5/07 0825 ND ND ND Q4539 909 MW-66 (48')
3/7/07 0956 ND ND ND Q4539R 909 MW-66 (48')
3/7/07 0956 ND ND ND Q4678 909 MW-66 (48')
3/9/07 0740 ND ND ND Q2133 969 MW-62 (50')
2/1/07 1016 ND ND ND Q2255 969 MW-62 (50')
2/8/07 1355 ND ND ND Q2279 969 MW-62 (50')
2/9/07 1017 ND ND ND Q2336 969 MW-62 (50')
2/10/07 0818 ND ND ND Q2295 969 MW-62 (50')
2/11/07 0820 ND ND ND Q2342 969 MW-62 (50')
2/12/07 1003 ND ND ND Q2695 969 MW-62 (50')
2/13/07 0959 ND ND ND Q2699 969 MW-62 (50')
2/14/07 1008 ND ND ND Q3203 969 MW-62 (50')
2/16/07 1156 ND I
ND IND Q3198 969 MW-62 (50')
2/19/07 0815 ND I
ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 25
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re 0OUL Station Station Name Date/Time Fluorescein Results Eosine Results Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q3149 969 MW-62 (50')
2/21/07 0828 ND ND ND Q3617 969 MW-62 (50')
2/23/07 0938 ND ND ND Q3554 969 MW-62 (50')
2/26/07 1056 ND ND ND Q3899 969 MW-62 (50')
2/28/07 1110 ND ND ND Q3899R 969 MW-62 (50')
2/28/07 1110 ND ND ND Q4054 969 MW-62 (50')
3/2/07 1005 ND ND ND Q4081 969 MW-62 (50')
3/5/07 1022 ND ND ND Q4538 969 MW-62 (50')
3/7/07 1158 ND ND ND Q4677 969 MW-62 (50')
3/9/07 0919 ND ND ND Q2116 1029 MW-63 (35')
2/1/07 1225 ND ND ND Q2285 1029 MW-63 (35')
2/8/07 1218 ND ND ND Q2231 1029 MW-63 (35')
2/9/07 1104 ND ND ND Q2335 1029 MW-63 (35')
2/10/07 1007 ND ND ND Q2294 1029 MW-63 (35')
2/11/07 0737 ND ND ND Q2341 1031 MW-63 (53')
2/12/07 1138 ND ND ND Q2694 1031 MW-63 (53')
2/13/07 0851 ND ND ND Q2694R 1031 MW-63 (53')
2/13/07 0851 ND ND ND Q2698 1031 MW-63 (53')
2/14/07 0910 ND ND ND Q3202 1031 MW-63 (53')
2/16/07 1255 ND ND ND Q3197 1031 MW-63 (53')
2/19/07 1005 ND ND ND Q3148 1031 MW-63 (53')
2/21/07 1049 ND ND ND Q3616 1031 MW-63 (53')
2/23/07 1025 ND ND ND Q3553 1031 MW-63 (53')
2/26/07 1125 ND ND ND Q3898 1031 MW-63 (53')
2/28/07 1146 ND ND ND Q4053 1031 MW-63 (53')
3/2/07 1054 ND ND ND Q4079 1031 MW-63 (53')
3/5/07 1050 ND ND ND Q4079R 1031 MW-63 (53')
3/5/07 1050 ND IND IND Q4537 1031 MW-63 (53')
3/7/07 1345 ND IND IND f:\\docs\\coa\\GZA.xls 3/19/2007 26
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
IRWT RP Al1l'
~tQf inn
- ,atunn 1%,~ma N*toflPim*
lk'huurj~cu'ln Rp~uult*
Eain* R~P'~uut4 Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q2282 1240 RW-1 (110')
2/9/07 1605 508.2 5.39 ND ND Q2282R 1240 RW-1 (110')
2/9/07 1605 508.3 5.35 ND ND Q2367 1240 RW-1 (110')
2/10/07 0907 508.4 198 ND ND Q2371 1240 RW-1 (110')
2/11/07 1100 508.3 985 ND ND Q2365 1240 RW-1 (110')
2/12/07 0852 508.4 661 ND ND Q3069 1240 RW-1 (110')
2/13/07 0810 508.5 659 ND ND Q3066 1240 RW-1 (110')
2/14/07 0901 508.3 379 ND ND Q3046 1240 RW-1 (110')
2/15/07 0840 508.8 172 ND ND Q3050 1240 RW-1 (110')
2/16/07 0835 508.6 565 ND ND Q3054 1240 RW-1 (110')
2/17/07 1013 508.5 370 ND ND Q3058 1240 RW-1 (110')
2/18/07 1004 508.2 405 ND ND Q3063 1240 RW-1 (110')
2/19/07 1042 508.3 262 ND ND Q3122 1240 RW-1 (110')
2/20/07 0850 508.8 222 ND ND Q3145 1240 RW-1 (110')
2/21/07 0922 508.7 186 ND ND Q3639 1242 RW-1 (97')
2/23/07 0848 508.6 255 ND ND Q3688 1242 RW-1 (97')
2/26/07 0900 508.3 193 ND ND Q3684 1242 RW-1 (97')
2/27/07 1037 508.5 166 ND ND Q3895 1242 RW-1 (97')
2/28/07 1115 508.7 152 ND ND Q4022 1242 RW-1 (97')
3/1/07 1200 508.3 168 ND ND Q4050 1242 RW-1 (97')
3/2/07 0909 508.3 142 ND ND Q4077 1242 RW-1 (97')
3/5/07 1135 508.2 109 ND ND Q4533 1242 RW-1 (97')
3/6/07 0946 508.5 139 ND ND Q4531 1242 RW-1 (97')
3/7/07 1156 508.3 102 ND
_ND Q4656 1242 RW-1 (97')
3/8/07 0915 508.7 98.6 ND ND Q4674 1242 RW-1 (97')
3/9/07 0840 508.5 139 ND ND Q2283 1250 RW-1 (140')
2/9/07 1610 508.2
- 0.111 ND ND Q2368 1250 RW-1 (140')
2/10/07 0854 508.5 62.0 ND IND Q2372 1250 RW-1 (140')
2/11/07 1100 508.4 7.11 ND IND f:\\docs\\coa\\GZA.xls 3/19/2007 27
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Preliminary Results Water Samples GZA Environmental, Inc.
RWT Re OULL Station Station Name Date/Time Fluorescein Results Eosine Results Recovered Peak nm Conc. ppb Peak nm Conc. ppb Peak nm Q2366 1250 RW-1 (140')
2/12/07 0847 508.4 143 ND ND Q3070 1250 RW-1 (140')
2/13/07 0817 508.2 730 ND ND Q3065 1250 RW-1 (140')
2/14/07 0858 508.3 754 ND ND Q3047 1250 RW-1 (140')
2/15/07 0843 508.7 490 ND ND Q3051 1250 RW-1 (140')
2/16/07 0830 508.4 410 ND ND Q3055 1250 RW-1 (140')
2/17/07 1006 508.3 521 ND ND Q3059 1250 RW-1 (140')
2/18/07 1000 508.3 375 ND ND Q3064 1250 RW-1 (140')
2/19/07 1032 508.3 68.4 ND ND FQ3 123 1250 RW-1 (140')
2/20/07 0846 508.3 340 ND ND Q3146 1250 RW-1 (118')
2/21/07 0918 508.2 197 ND ND Q3641 1250 RW-1 (118')
2/23/07 0840 508.5 264 ND ND Q3689 1250 RW-1 (118')
2/26/07 0855 508.3 261 ND ND Q3685 1250 RW-1 (118')
2/27/07 1035 508.4 149 ND ND Q3896 1250 RW-1 (118')
2/28/07 1106 508.3 221 ND ND Q4023 1250 RW-1 (118')
3/1/07 1156 508.3 226 ND ND Q4051 1250 RW-1 (118')
3/2/07 0904 508.6 259 ND ND Q4078 1250 RW-1 (118')
3/5/07 1139 508.1 90.0 ND ND Q4534 1250 RW-1 (118')
3/6/07 0952 508.4 97.3 ND ND Q4532 1250 RW-1 (118')
3/7/07 1151 508.3 80.7 ND ND Q4657 1250 RW-1 (118')
3/8/070912 508.7 192 ND ND Q4675 1250 RW-1 (118')
3/9/07 0830 508.6 64.6 ND I
ND f:\\docs\\coa\\GZA.xls 3/19/2007 28
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility QAIQC results GZA Environmental, Inc Table 3.
Quality control results for field equipment analyzed for the presence of fluorescein, eosine and rhodamine Peak wnvelen *th* nre rennrted1 in nnncnmeter* (nmV: dvR cenneentriition n*re re~nnrt&d in nart* her hillinn (nnh¥ OUL Station Station Name Date/Time Date/Time Fluorescein Results Eosine Placed Recovered Peak nm Conc. ppb Peak n Q1064 ET Electrical Tape 11/28/06 1354 ND ND Q1063 SC Indian Point Sampler Cord
_11/28/06 0909 ND ND f:\\docs\\coa\\GZA.xls 3/12/07 1
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility QA/QC results GZA Environmental, Inc WT (RWT) dyes.
Results RWT Results Cone. ppb Peak nmt Cone. ppb ND
.ND f:\\docs\\coa\\GZA.xls 3/12/07 2
Ozark Underground Laboratory, Inc.
Indian Point Nuclear Facility Footnotes GZA Environmental, Inc.
Footnotes:
ND = No dye detected
- = A fluorescence peak is present that does not meet all the criteria for a positive dye result. However, it has been calculated as though it were the tracer dye for background purposes.
- = A fluorescence peak is present that does not meet all the criteria for a positive dye result. However, it has been calculated as a positive dye result.
f:\\docs\\coa\\GZA.xls 3/19/2007 I