F, James Noaale - Latest State Data Paae 1 11 l~ James Nooale - Latest State Data Paoe 1 I From:

To:

Kottan" <JJK@

Date:

Subject:

"Timothy Rice" <tbrice@gw.dec.state.ny.us>

"Joseph J. Adler" <jadler@entergy.com>, "James Noggle" <JDN@nrc.gov>, "James nrc.gov>, <jrw@nrc.gov>

Mon, Dec 4, 2006 9:36 AM Latest State Data Attached is an updated excel file with new data from:

8/30/06 MW-53 @ 120' 9/15/06 MW-59 @ 70' H-3 seen at both locations, MW-53 @ 120' 4,000+/-200 MW-59 @ 70' 240+/-120 Sr-90 MW-53 @ 120' MW-59 @ 70' 20.1+/-0.9

<0.5 Tim I

Indian Point Groundwater Investigation Summary NYS Results as of 01 /18/2007 Sampling Date SampleýIR*.

Sample oItLti*n.

Triti irii pi"/V Sr-90 pCill GahinTf Spec GB pCi/l GA pCi/Il 10/21/2005 200520855628 U2 CST

<110 NA NA 10/21/2005 200520855629 U3-T2 1420 +/- 160 NA NA 10/21/2005 200520855630 U3-2 510 +/- 130 NA NA 10/21/2005 200520855631 MW-111 267000 +/- 8000 1.9 +/- 0.7

  • ND 9.0 +/- 6.0 5.0 +4-2.0 10/21/2005 200520855632 U3-4 340 +/- 120 NA NA 10/21/2005 200520855633 U3-1

<110 NA NA 10/21/2005 200520855634 U3-3

<110 NA NA 10/21/2005 200520855535 U3-T1

<110 NA NA 11/30/2005 200520855645 Trap Rock Quarry 90 +/- 60

<0.5 ***

ND 11/30/2005 200520855646 Algonquin Creek

<60

<0.5 ***

RDP 11/30/2005 200520855647 5th Street Well

<60

<0.5 RDP 11/30/2005 200520855648 Gypsum Plant Outfall

<60

<0.5 RDP 12/06/2005 200520855658 LaFarge Gypsum Well #1

<50 NA NA 12/06/2005 200520855659 LaFarge Gypsum Well #3

<50 NA NA 12/08/2005 200520855654 MW38 700 +/- 120 NA NA 12/08/2005 200520855655 MW101

<50 NA NA 12/08/2005 200520855656 MW 105 100 +/- 90 NA NA 12/08/2005 200520855657 MW107

<50 NA NA 02/07/2006 200620865001 MW-30 72' 3.76E5 +/- 0.11 E5

<0.5 ND 02/07/2006 200620865002 MW-31 3.38E4 +/- 0.12E4

<0.5 ND 02/07/2006 200620865003 MW-32 1.92E4 +/- 0.07E4

<0.6 ND 02/07/2006 200620865004 MW-33 2.02E5 +/- 0.06E5

<0.5 ND 02/07/2006 200620865005 MW-34 1.74E5 +/- 0.05E5

<0.6 ND 02/07/2006 200620865006 MW-35 8.9E4 +/- 0.3E4

<0.5 ND 02/07/2006 200620865007 MW-36 2.1 E4 +/- 0.08E4 1.1 +/- 0.6 ND 02/08/2006 200620865008 MW-38

<110

<0.5 ND 02/08/2006 200620865009 MW-48 250 +/- 110

<0.5 ND 02/07/2006 200620865010 MW-111 1.96E5 +/- 0.06E5 1.6 +/- 0.05 ND 9.9 +/- 1.7 2.6 +/- 0.9 01/30/2006 200620865011 Doodletown Bight @ PIP Maint.

<90

<0.5 ND 02/08/2006 200620865012 Algonquin Creek

<90

<0.6 ND 02/08/2006 200620865013 Trap Rock Quarry

<90 0.9 +/- 0.6 ND 01/30/2006 200620865014 Lake Kanawauke

<90

<0.4 ND 01/30/2006 200620865015 Ramalpo River @ Arden Rd

,<90

<0.4 ND 02/08/2006 200620865016 Hudson River Middle of waterfront

<90

<0.4 ND 02/08/2006 200620865017 Hudson River Unit 2 Outfall

<90

<0.4 ND 02/08/2006 200620865018 Hudson River Off Manhole 1

<90

<0.4 ND 02/08/2006 200620865019 Gypsum Plant Outfall

<90.

.<0.4 ND 02/08/2006 200620865020 Hudson River-North-of-IPEC

<90.

<1.0 ND

Indian Point Groundwater Investigation Summary NYS Results as of 01/18/2007 Sampling Date S*smple ID

'Samp Locatiorn,-

TritiuirInpCl/./*

r-OS90 Ci/l. 'Gamrmia Spec

-ýGB pCi/I GA pCi/I 02/28/2006 200620865024 MW-37 22' 1.48E4 +/- 0.06E4 INS ND 02/28/2006 200620865025 MW-37 32' 2.89E4 +/- 0.10E4 INS ND 02/28/2006 200620865026 MW-37 40' 1.61 E4 +/- 0.06E4 INS ND 02/28/2006 200620865027 MW-37 57' 1.54E4 +0- 0.06E4 INS ND 03/10/2006 200620865028 MW-37 22' 2.20E4 +0- 0.08E4 8.3 +/- 0.7 ND 26 +/- 4

<1.7 03/10/2006 200620865029 MW-37 32' 2.79E4 +/- 0.10E4 23.9 +/- 1.1 ND 56+/-4 3.8 +/- 1.7 03/10/2006 200620865030 MW-37 40' **

1.63E4 +/- 0.06E4 22.3 +/- 1.2 ND 73 +/- 7 67 +/- 4 03/10/2006 200620865031 MW-37 57' 1.54E4+/- 0.06E4 27.3 +/- 1.2 ND 62 +/- 4 2.9 +/- 1.8 03/22/2006 200620865040 MW-49 25.5' 1.53E4 +/- 0.06E4 17.0 +/- 0.9 ND 44+/-4

<1.5 03/22/2006 200620865041 MW-49 42' 9.4E3 +/- 0.4E3 24.1 +/- 1.1 ND 58 +/- 4 3.2 +/- 1.6 03/22/2006 200620865042 MW-49 65.5' 6.7E3 +/- 0.3E3 23.8 +/- 1.1 ND 53 +/- 4 84 +/- 1.6 03/22/2006 200620865043 MW-50 42' 7.7E3 +/- 0.4E3 25.9 +/- 1.2 ND 63 +/- 4 3.6 +/- 1.2 03/22/2006 200620865044 MW-50 67' 9.8E3 +/- 0.4E3 31.6 +4-1.3 ND 76 +/- 4

<1.2 03/23/2006 200620865045 MW-42 49' 2.7E3 +/- 0.2E3 60 +/- 2 Cs137, Co60 1.32E4 +/-0.04E4 68 +/- 3 MW-42 49' with solids, Cs-1 37 1.99E4 +/- 6.12E2 MW-42 49' decanted, Cs-137 1.31 E4 +/- 0.04E4 MW-42 49' with solids, Co-60 23 +/- 6 MW-42 49' decanted, Co-60 21 +/- 11 03/24/2006 200620865046 MW-42 78' 4.7E2 +/- 1.2E2

<1.0 Cs137, Co60, K40, RDF 94.8 +/-6.8 6.9 +/-3.8 MW-42 78' with solids, Cs-137 1.12E3 +/- 0.04E3 MW-42 78' decanted, Cs-137 1.85E2 +/- 0.4E2 MW-42 78' with solids, Co-60 3.4 +4- 0.9 MW-42 78' decanted, Co-60

<5.9 MW-42 78' with solids, K-40 40 +/- 10 MW-42 78' decanted, K-40

<98 03/23/2006 200620865037 MW-36 26' 3.53E4 +/- 0.12E4 0.9 +/- 0.4 ND 16 +/- 3 8.1 +/- 1.5 03/24/2006 200620865038 MW-36 41' 5.97E4 +/- 0.19E4 4.4 +/- 0.5 ND 17+/-3 3.7 +/- 1.1 03/23/2006 200620865039 MW-36 52' 2.65E4 +/- 0.09E4 6.1 +/- 0.5 ND 21 +/- 3 9.9 +/- 1.4 04/13/2006 200620865047 MW-47 56' 5.0E2 +/- 1.4E2 0.8 +/- 0.7 ND 25+/- 8 21 +/- 4 04/13/2006 200620865048 MW-47 80' 2.1 E3 +/- 0.2E3 3.9 +/- 0.4 ND 15 +/! 4 1.7 +/- 1.5 04/12/2006 200620865049 MW-46 30' 1.78E3 +/- 0.18E3

<0.9 ND 20+/-8 15 +/- 4 04/11/2006 200620865050 MW-40 200'

<100 0.7 +/-0.4 ND 16 +/-8 15+/-4 04/11/2006 200620865051 MW-51 200' 1.5E2 +/- 1.1 E2

<0.4 ND 15 +/- 6 20 +/- 2 04/12/2006 200620865052 MW-48 37.5' 1.2E2 +/- 1.0E2

<0.7 RDP 24+/-4 29.5 +/- 1.7 04/12/2006 200620865053 MW-48 52' 3.7E2 +/- 1.3E2

<0.7 ND 25 +/- 8 13 +/- 3 04/12/2006 200620865054 MW-41 41' 5.8E2 +/- 1.4E2.

5.0 +/- 0.8 ND.

18 +/- 4 4.2 +/- 1.6 04/12/2006 200620865055 MW-41 63' 4.7E2 +/- 1.3E2 5.7 4/- 0.5 ND 16+/-4 3.1 +/- 1.6 04/12/2006 200620865056 MW-43 28' 2.9E2'+/- 1.2E2

<0.4 K40, RDP

<20 20 +/- 7 04/12/2006 200620865057 MW-43 62'

<110 0.6 +/- 0.4 ND 14+/-6 26 +/- 20

Indian Point Groundwater Investigation Summary NYS Results as of 01/18/2007 Samplingd:Date Sample ID Sample Location

'*;p TritiumpCi/VI,.-

Sr-90o'i/Ji/

'Gamma-Spec GB pCi/i GA pCi/I 04/11/2006 200620865058 Fishkill Creek

<130

<0.4 ND

<4.0 1.2 +4-1.0 04/11/2006 200620865059 Philpse Brook

<90.

<0.4 ND

<1.1 0.35 +/- 0.19 04/17/2006 200620865060 MH-5 U2 Curtain prior to outage 2.3E2 +/- 1.0E2

<0.4 N D 7 +/-4

<1.1 04/18/2006 200620865061 Hudson River near MH1 Discharge

<90

<0.5 ND 13+/-4 7.9 +4-1.2 08/18/2006 200620865087 MW-30 74' 2.49E5 +/- 0.08E5

<0.7 ND 11 +/-4 9 +/-3 08/22/2006 200620865088 MW-30 88' 4.52E4 +/- 0.18E4

<0.7 ND 11 +/- 4 6 +/- 3 08/23/2006 200620865124 MW-53 80' 1.21 E4 +/- 0605E4 9.3 +/- 0.6 N D 29+/-7 11 +/-4 08/24/2006 200620865122 MW-57 45' 4.1 E3 +/- 0.3E3 24.9 +4-1.1 ND 45 +/- 9

<7 08/25/2006 200620865123 MW-55 78' 1.47E4 +/- 0.06E4 30.2 +/- 1.2 ND 70+/-5

<3 08/30/2006 200620865125 MW-53 120.****

4.0E3 +/- 0.2E3 20.1 +/- 0.9 Ra226 43 +/- 9 62 +/- 8 MW-53 120' unfiltered, Ra226

. 22+/- 9 MW-53 120' filtered, Ra226 6 +/- 5 09/07/2006 200620865126 MW-54 206' 2.47E3 +/- 0.19E3 15+/-0.9 ND 44 +/-5 16+/-3 09/08/2006 200620865127 MW-56 85' 8.3E2 +/- 1.3E2 2.2 +/- 0.5 ND 11 +/-4

<2 09/08/2006 200620865128 MW-65 80' 2.3E2 +/- 1.1 E2

<0.5 ND 30+/-8 32 +/-6 09/15/2006 200620865141 MW-59 70' 2.4E2 +/- 1.2E2

<0.5 Ra226 36 +/- 8 8 +/- 7 MW-59 70',

Ra226

_6

+/--4 09/19/2006 200620865138 LAkF.001- (003).

<120

<0.4.

ND 33 +/- 8 8 +/- 5 09/19/2006 200620865139 LAF-002 (003)

<120

<0.5 ND 35 +/- 8 70 +/- 6 09/19/2006 200620865140 LAF-003 (003)

<120

<0.5 ND 6+/-3 2.6 +4-1.9 LAF - LaFarge Gypsum Well GA - Gross Alpha, GB - Gross Beta NA - Not Applicable (This analysis was not performed)

ND - Non Detect ( No readings at or above detection limits)

RDP - Dissolved Radon Decay Products INS - Insufficient Sample Volume for this Analysis Sr-90 Bkg Range =0.8 - 1.3 pCi/I NYSDOH Data, 1987 - 1990.

  • Analysis for Sr-90 repeated with 600ml of sample for better counting statistics
    • Review of GA Result requested -->sample high in suspended solids Result recalculated to account for new filter paper