ML062000151

From kanterella
Jump to navigation Jump to search
E-mail from K. Mcmullian, Entergy, to J. Boska, NRR, Et Al., IPEC Status Report April 13
ML062000151
Person / Time
Site: Indian Point  
Issue date: 04/13/2006
From: Mcmullin K
Entergy Corp
To: Boska J, Cobey E, Brian Holian, Diane Jackson
Office of Nuclear Reactor Regulation
References
FOIA/PA-2006-0195
Download: ML062000151 (5)


Text

.is go I LJVOICý -I I L-%-, Otatuo I cpvlt I VI ryl [I I) rage "

From:

"McMullin, Kathleen M" <KMcMull@entergy.com>

E.-

To:

T"

_" Baranski, James'

<james.baranski@semo.state.ny.us>, " Eddy, Paul" <pauL~eddy@dps.state.ny.us>, "Greeley, Dan"

<greeleyd@co.rockland.ny.us>, "Gross, Steve - Orange PIO" <sgross@co.orange.ny.us>, "Meyer, Sue-Rockland Alt. POLO" <Meyers @co.rockland.ny.us>, "Sutton, Tony" <awsl @westchestergov.com>,

"Adam Stiebeling (AStiebeling@pcbes.org)" <AStiebeling@pcbes.org>, "Albanese, Raymond"

<rlal @westchestergov.com>, Alfredo Vidal <avidal @thevidalgroup.com>, "Anthony Sutton (awsl @weschestergov.com)" <awsl @weschestergov.com>, "B. Gore" <bgore@urbanomics.com>,

"Baker Nancy (bakerna@co.rockland.ny.us)" <bakerna@co.rockland.ny.us>, "Barry, Terrence"

<TBarry@entergy.com>, "Benjamin, Liz" <BenjamiL@co.rockland.ny.us>, "Bentley, Robyn M"

<rbentle@entergy.com>, "Bergmann Ken (ken.bergmann@semo.state.ny.us)"

<ken.bergmann @semo.state.ny.us>, Bernie McGarry <mcgarry@senate.state.ny.us>, "Blizard, Andrea J"

<ablizar@entergy.com>, "Bob Outhouse (rjo4@westchestergov.com.)" <rjo4@westchestergov.com>,

"Bordewich Jean (jean-bordewich@sch.umer.senate.gov)" <jean.bordewich@schumer.senate.gov>,

"Bordewich Jean:

"Boska John (jpbl @nrc.gov)"

<jpbl @nrc.gov>, "Bowman, Greg "<GBowm9O@cc--exsO3.prod.entergy.com>, Brian Holian

<bjm@nrc.gov>, "Brian Holian (beh@nrc.gov)" <beh@nrc.gov>, "Bridges Jeff (JBridges @ troopers.state.ny.us)" <JBridges @ troopers.state.ny.us>, Chief Tubbs Chris Schwarz <cschwar@ entergy.com>, "Cobey Gene (ewc@nrc.gov.)"

<ewc@nrc.gov>, "Comiotes, Jim" <JComiot@entergy.com>, "Conroy, Patric W"

<PConroy@entergy.com>, "Cooper Linda (lindac@yorktownny.org)" <lindac@yorktownny.org>, "Cox, Mark R" <mcox90 @ entergy.com>, "Crawford Garnesha (Gcrawford @ urbanomics.com)"

<Gcrawford@ urbanomics.com>, "Curran Nick" <Nick.curran @mail.house.gov>, "Dacimo, Fred R"

  • <FDacimo@entergy.com>, David BrandL
] David Greene

<dgreene @ urbanomics.com>, David Weinraub <DWeinraub @ bmwlobby.com>, "DeGasperis, Edward M"

<edegasp @ entergy.com>, "DiRocco, Anthony J" <ADirocc @ entergy.com>, "Don Maurer (Donald.Maurer@semo.state.ny.us)" <Donald.Maurer@semo.state.ny.us>, "Dowling, Adele"

<amd2 @ westchestergov.com>, "Drew Barney (Barney.Drew@ lafarge-na.com)"

  • <Barney.Drew@lafarge-na.com>, "Elisa Gwilliam l

0 "Fay, Deborah" <DFayl @entergy.com>., Feather <jdf@fcwc-law.com5, 15eney Andrew (Andrew.Feeney@ semo.state.ny.us)" <Andrew.Feeney@semo.state.ny.us>, "Feroe Peter

  • (peter.feroe@mail.house.gov)" <peter.feroe@mail.house.gov>, Geri ShapiroF"

'-I "Gibbons Emily (Emily.Gibbons@mail.house.gov)" <Emily.Gibbons@mail.house.gov>, "Giguere, Kathieen M" <KGiguer@entergy.com>, "Glenn Troester (grtroes@nppd.com)" <grtroes@nppd.com>, "Gottlieb, Laurence" <LGottli@entergy.com>, "Greene, Dominick" <dgreene@co.orange.ny.us>, "Grosjean, Alaln G"

<AGrosje@entergy.com>, "Guiao Frank (Frank.Guiao@lafarge-na.com)"

<Frank.Guiao@lafarge-na.com>, Harry Giannoulis <harry@ theparksidegroup.com>, "Hinrichs, Gary H"

<ghinric@entergy.com>, "Hipschman, Thomas" <thips90@entergy.com>, "Inzirillo, Frank A"

<finziri @ entergy.com>,'lra Promisel <ipromise @troopers.state.ny.us>, Jack Spath <jps @ nyserda.org>,

"Jackson Don (dejl @nrc.gov)" <dejl @nrc.gov>, "Jeff Tkacs Uefft@townofcortlandt.com)"

<jefft@townofcortlandt.com>, "Jensen, Chris' <jensenc@co.rockland.ny.us>, JES

<JES1 @westchestergov.com>, Jim Cunningham <jimcunningham@nyc.bm.com>, Jim Wright

<wright@senate.state.ny.us>, John Cordo <JLC@fcwc-law.com>, "Jones, T. R." <tjones2@entergy.com>,

"Kansler, Michael R" <MKansle@entergy.com>, Kathleen Wood <kathleen.wood@chamber.state.ny.us>,

"Keegan Pat (Pat.keegan @ mail.house.gov)" <Pat.keegan @ mail.house.gov>, "Kerns, Matthew T"

<MKerns @ entergy.com>, "Kopy Mike (MKopy@troopers.state.ny.us)" <MKopy@troopers.state.ny.us>,

"Kraus Kevin (kevin.kraus @ semo.state.ny.us)" <kevin.kraus @ semo.state.ny.us> 4. Leach" C

1 "Leach, Don" <DLeach @ entergy.com>, "Leibell Vincefii" (leibell@ senate.state.ny.uis)" <leibell @ senate.state.ny.us>

Date:

4/13/06 4:38PM

Subject:

IPEC status report for April 13 See attachment with map and well results Intma in im record was cL4etM in a=WoWW Wtof tg fMdM~i

VllI$ LjVDr\\a - Ir LA.,ý CILCUU I VVJIt I UI /rPii I 1 rttyu e-I Indian Point Energy Center Status Report April 13, 2006 Operational Status - 2R17 Outage Preparations Indian Point Unit 2 is operating at 100% and has been on line 42 days. Indian Point Unit 3 is operating at 100% reactor power and has been on-line for 190 days.

Operations and maintenance crews are preparing for Indian Point Unit 2's upcoming refueling outage scheduled to begin later this month. The outage scope includes replacing about 1/3 of the fuel assemblies and full primary and secondary side inspections of the four steam generators. Entergy will also conduct the 10-year Integrated System Inspection as well as the Integrated Leak Rate Test to measure containment integrity. Routine preventive maintenance and surveillances will be conducted on a number of pumps, valves and associated piping.

Groundwater Investigation Entergy released sample results today from four wells, three along the discharge canal and one near Unit 1, which indicate the presence of Strontium-90 in the water. The test results from MW-49, MW-50 and MW-36, the wells along the discharge canal, show levels of Strontium-90 ranging from 1.00 to 25.5 pCi/L.

Tritium levels range from 26, 800 to 55,200 pCi/L tritium. (See attached map for locations)

These results are consistent with previously reported results from MW-37, which indicated the presence of Sr-90 along the discharge canal.

A series of samples obtained from MW-42, which is located adjacent to the Unit 1 spent fuel pool, show isotopes characteristic of North curtain drain water. (See attached sample results table). A tracer test will be conducted to help determine the source of the contaminants found in these samples. It is possible that the well intercepted a section of the North curtain drains at Unit 1.

Entergy has initiated actions to reduce the concentration of Sr-90 in the Unit 1 spent fuel pool.

Deminieralizers connected to the pool will help reduce the amount of Sr-90 in the pool and thus the amount which is captured by the curtain drains. Entergy is evaluating additional processing in the curtain drains to further reduce the Sr-90 concentration. These actions are being taken in advance of any overall site remediation plan and will enhance the effectiveness of which ever strategy maybe employed. Tracer tests, mentioned above, will help evaluate the effectiveness of the Sr-90 processing.

uj ii i outoma - ir rzt.. btatut, i t-pui t wi mpi ii i o raYe 1*

No radioactivity has been detected in any off-site monitoring location.

Status Report Available on JIC Website The Indian Point status report is now available on the new Joint Information Center web site. The web site is part of the virtual news room concept that is being developed for public emergency information. The web site will also include the latest radiological release information for Indian Point.

To preview the web site follow the link to Indian Point

<http://jic.semo.state.ny.us/PlantStatus/PlantStatusMain.aspx> Status Page Educational Outreach Entergy Nuclear Northeast provides customized outreach education programs for schools, youth groups, and civic organizations. The topics we cover include Emergency Planning, Understanding Radiation, Nuclear Fuel and a general overview of the operations of Indian Point Energy Center. If you would like a brochure or are interested in scheduling a program, contact IPEC Communications at 914-271-7441.

If you have any questions or need clarification of the information provided, please contact Kathy McMullin, manager of communications, Indian Point Energy Center, at 914-271-7132.

I4

-'I

~K.

~6, If~

C-

-~

LV MW 36

.fla; W 37 I.+-:-:+:-:'*+*

+>
?,5*>.++,;.+5
  • DISCHARGE

+?i*:!:`*1`.?*+.*.)::.:S.`*?

CAN,7,:.*,*r*::.

F,,:

. +:* 6 g

-:7>:

I Unit..

TURBINE..BLDG MW 50..,,,

I l

I MW En tegyW 4/13/2006 Diagram showing approximate location of monitoring wells.

Phase 2 well I~Phase1 well

Monitoring Well Results Depth Date ID (ft)

H3 Sr-90 312312006 MW-36 26 34,200 1

3/24/2006 MW-36A 41 55,200 3.48 3/24/2006 MW-36B 52 26,800 4.11 3/22/2006 MW-49 25 15,400 18.4 3/22/2006 42 11,300 19.4 3/22/2006 65 5,430 18.5 3/22/2006 MW-50 42 9,750 19.3 67 6,810 25.5 I MW47 a

aY a

-94 3/3-4100 i~a..

4/13200