Interim Report for Completed Analyses for Samples from Sets Fifteen and Sixteen, from the Indian Point Power Station, Buchanan, New York. (Inspection Report No. 050-247/2006-007) (Rfta No.06-001)
ML070110561
Person / Time
Site: Indian Point 
(DPR-026)
Issue date: 12/15/2006
From: Condra D
Oak Ridge Institute for Science & Education
To: Kottan J
NRC Region 1
References
IR-06-007, RFTA-06-001
Download: ML070110561 (5)


Text

RECEIVED O

R k

E REGKIH 1 OAK RIDGE INSTITUTE FOR SCIENCE AND EDUCATION Mr. Jim Kottan U.S. Nuclear Regulatory Commission Region I 475 Allendale Road IOng of Prussia, PA 19406

SUBJECT:

INTERIM REPORT FOR COMPLETED ANALYSES FOR SAMPLES FROM SETS FIFTEEN AND SIXTEEN, FROM THE INDIAN POINT POWER STATION, BUCHANAN, NEW YORK

[INSPECTION REPORT NO. 050-247/2006-0071 [RFTA NO. 06-0011

Dear Mr. Kottan:

The Oak Ridge Institute for Science and Education (ORISE) received set 15, consisting of 15 water samples, on November 21 and November 22, 2006 and set 16, consisting of ten water samples, on November 27,2006 associated with the Indian Point Power Station. Sample analysis was initiated based on your previous direction for handling samples from ths licensee. Sample identification and collection data for the samples addressed in h s report are presented in Table 1. Gamma spectroscopy, hard to detect beta emitters (iron-55, nickel-59-63, and tritium) and carbon-14 are provided in Tables 2 through Table 4, respectively. The pertinent procedure references are provided in each specific table.

ORISEs Quality Control (QC) requirements were met for these analyses. The QC files are available for your review upon request. Additional reports will follow after the completion of the requested analyses.

My contact information is listed below. You may also contact Wade Ivey at 865.576.9184 with any questions or comments.

Sincerely, Dale Condra, Manager Laboratory RDC:wPI:km Enclosures C:

B. Watson, FSME/DWMEP/DD/SP 7E18 E. Abelquist, ORISE E. I-hox-Davin, NRC/FSME/TWFN 8x23 M. Roberts, NRC Region I File 1697 S. IQrk, ORISE J. White, NRC Region I Distribution approval and concurrence :

Technical Management Team Member Quality Manager U

Voice: 865.241.3242 Fax: 865.241.3248 E-mad: CondraD@orau.gov

TABLE 1 ORISE Sample ID 1697~0078 SAMPLE IDENTIFICATIONS AND COLLECTION DATA INDIAN POINT POWER STATION BUCHANAN, NEW YORK NRC Region I Collection Collection Sample ID Date Time Mw-41-42-(007) 1 1 /13 /2006 12:55 1697W0079 1697W0080 1697W0081 1697~0082 I

MW-41 (006) 11/13/2006 13:10 MW-45 (007) 1 1 /13/2006 13:20 Mw-53-80-(002) 1 1 /9/2006 11:15 MW-45-62-(007) 11/13/2006 11 :20 11 1697W0083 I Mw-53-120-(002) I 11/9/2006 I 11:20 T69mOO84 1697W0085 1697W0086 1697W0087 1697W0088 MW-5 5 (001) 11/9/2006 13:20 Mw-55-35-(001) 11 /9/2006 13:40 Mw-55-54-(001) 11 /9/2006 13:30 hIw-50-67-(008) 1 1 /15/2006 10:37 IMw-56 (002) 11 /9/2006 10:20 1697W0089 I MW-SO-42-(008)

I 11/15/2006 I 10:47 169%0090 1697W0091 1697~0092 1697~0093 1697~0094 1697~0095 1697W0096 Mw-49-26-(008) 11 /15/2006 11:28 MW-49-65-(008) 11 /15/2006 13:46 MW-42-48' 11 /16/2006 10:52 Mw-42-43' 11 /16/2006 14:24 MW-42-45.5' 11/16/2006 13:02 Mw-42-41' 11 /17/2006 8:44 MW-49-42-(008) 1 1 /15/2006 1421 11 1697W0097 I MW-59-31-(001) I 11/16/2006 I 11:05 1 6 9 m 0 0 9 8 1697~0099 1697W0100 1697W0101 1697W0102 MW-59-45-(001) 11 /16/2006 11:18 MW-59 (00 1) 1 1 /16/2006 11:30 MW-58-26-(001) 11/16/2006 13:25 MW-58-65-(001) 11 /16/2006 13:18 MW-39-200-(005) 1 1 /17/2006 13:49 Indian Point Power Station projects/l697/Data TabIes/2006-12-15 Data Tables Sets 15-16

TABLE 2 CONCENTRATIONS OF SELECTED GAMMA EMITTING RADIONUCLIDES IN WATER SAMPLES BY GAMMA SPECTROSCOPY CP1, REVISION 15 INDIAN POINT POWER STATION BUCHANAN, NEW YORK

%e range of MDCs for the selected radionuclides is 2.6 pCi/L to 10 pCi/L buncertainties represent the 95% confidence level, based on total propagated uncertainties.

Zero value due to rounding.

Indian Point Power Station projects/l697/DataTables/2006-12-15 Data Tables Sets 15-16

TABLE 3 ORISE Sample ID CONCENTRATIONS OF HARD T O DETECT BETA EMITTING RADIONUCLIDES IN WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEW YORK Radionuclide Concentrationsa (pCi/L)

NRC Region I Sample ID F12-55~

Ni-59" Ni-63" H-3d 1697W0079 1697W0080 1697W0081 1697W0082 1697W0083 1697W0084 1697W0085 1697W0078 I MW-41-42-(007) I 15 k 1 8 ~ (31) I -7.1 k 4.2 (7.3) I 2.4 t-5.8 (9.8) I 600 f 240 (370)11 MW-41-64-(006) 16 k 18 (31)

-7.0 k 4.2 (7.3) 2.9 t-5.8 (9.8) 300 k 220 (370)

MW-45-43-(007)

.16 k 18 (31)

-8.8 k 4.2 (7.3) 4.7 k 5.8 (9.8) 710 k 250 (370)

MW-45-62-(007)

-1 k 18 (31) -12.8 2 4.1 (7.3) 5.0 f. 5.8 (9.8) 1,140 k 270 (370)

MW-53-80-(002) 19 k 19 (31)

-9.2 f 4.2 (7.3) 5.6 ? 5.8 (9.8) 570 k 240 (370)

Mw-53-120-(002) 22 2 19 (31) -10.9 k 4.1 (7.3) 27.7 k 6.5 (9.8) 8,210 It_ 570 (370)

MW-55-24-(001) 13 2 18 (31)

-6.8 2 4.2 (7.3) 3.1 2 5.8 (9.8) 1,890 k 310 (370)

MW-55-35-(001)

-5 f 18 (32)

-4.3 If: 4.2 (7.3) 3.8 f. 5.8 (9.8) 9,450 k 620 (370) 1697W0086 1697W0087 MW-55-54-(001) 4 k 19 (32)

-1.5 k 3.6 (6.2) 9.6 k 5.4 (8.8) 12,840 k 750 (370)

MW-56-85-(002)

-4 2 18 (32) 2.9

& 3.7 (6.2) 1.2 k 5.2 (8.8) 210 k 220 (370) 1697W0088 1697W0089 MW-50-67-(008) 9 k 19 (32) 0.1

& 3.6 (6.2) 7.9 k 5.3 (8.8) 5,620 k 470 (370)

MW-50-42-(008) 7 k 19 (32) 1.0 f 3.7 (6.2) 4.4 ? 5.2 (8.8) 2,740 k 350 (370) 1697W0090 1697W0091 1697W0092 Mw-49-26-(008)

-11 f 18 (32)

-2.3 k 3.6 (6.2) 7.9 k 5.3 (8.8) 9,070 k G10 (370)

MW-49-42-(008) 2 k 19 (32) 2.3 k 3.7 (6.2) 4.7 k 5.2 (8.8) 6,300 f. 500 (370)

MW-49-65-(008)

-6 k 18 (32)

-5.5 k 3.6 (6.2) 9.6 rf: 5.4 (8.8) 3,590 k 390 (370) 1697W0093 1697 WOO94 Indian Point Power Station MW-42-48' 5 f 40 (68) 29 f 10 (16) 249

_+ 23 (24) 2,200 L 350 (420)

MW-42-43' Of f 40 (68) 13.3 f. 9.9 (16.5) 295 k 25 (24) 2,100 2 340 (420) projects/l697/Data Tables/2006-12-15 Data Tables Sets 15-16 1697W0095 1697W0096 1697W0097 1697W0098 1697W0099 1697W0100 MW-42-45.5' 19 k 40 (68) 9.1 f 9.8 (16.5) 290 2 25 (24) 2,590 k 370 (420)

MW-42-4 1'

-3 f 40 (68) 10.0 k 9.9 (16.5) 201 k 21 (24) 2,060 k 340 (420)

MW-59-31-(001) 4 k 20 (34) 0.4 k 3.9 (6.6) 1.4 2 5.6 (9.5) 70 k 240 (420)

Mw-59-45-(001)

-10 k 20 (34)

-5.4 k 3.8 (6.6) 4.8 2 5.7 (9.5) 130 k 250 (420)

MW-59-68-(001) 8 2 20 (34) 0.0 k 3.9 (6.6) 1.2 k 5.6 (9.5) 90 L 240 (420)

MW-58-26-(001) 3 k 20 (34) 3.1 k 3.9 (6.6) 0.1 f. 5.6 (9.5) 10 k 240 (420) 1697W0101 1697W0102 MW-58-65-(001) 8 k 20 (34) 2.3 f 3.9 (6.6) 0.5 L 5.6 (9.5) 120 k 250 (420)

MW-39-200-(005)

-5 k 20 (34) 6.8 k 4.0 (6.6)

-3.0 k 5.5 (9.5) 10 k 240 (420)

TABLE 4 ORISE Sample ID 1697W0078 1697w0079 CONCENTRATIONS OF CARBON-14 I N WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP9, REVISION 3; CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEW YORK NRC Region I Radionuclide Concentrations, MW-41-42-(007)

-11.1 f

9.3b (16.2)

AlW-41-64-(006)

-7.8 f

9.3 (1 6.2)

Sample ID TPUs, and MDCS" (pCi/L) 1697W0098 1697w0099 1697W0100 1697W0101 MW-59-45-(00 1)

NDA MW-59-68-(001)

NDA MW-58-26-(001)

NDA hIw-58-65-(001)

NDA I

1697W0102 1 Mw-39-200-(005) I NDA

'MDCs are in parcntheses.

buncertainties represent the 95% confidence level, based on total propagatcd uncertainties.

'C-14 results for samples WOO93 through W0102 not available to issue with this interim letter report Indian Point Power Station projects/l697/Data Tables/2006-12-15 Data Tables Sets 15-16