Interim Report for Completed Analysis for Samples from Set Twenty-One from the Indian Point Power Station, Buchanan, New York. Dtd. May 3, 2007
ML072840255
Person / Time
Site: Indian Point 
Issue date: 05/03/2007
From: Condra D
Oak Ridge Institute for Science & Education
To: Kottan J
Division of Nuclear Materials Safety I
References
IR-06-007 RFTA 06-001
Download: ML072840255 (9)


Text

o K I S E OAK RIDGE INSTITUTE FOR SCIENCE AND EDUCATION May 3,2007 Mr. Jim Kottan US. Nuclear Regulatory Commission Regon I 475 Allendale Road King of Prussia, PA 19406

SUBJECT:

INTERIM REPORT FOR COMPLETED ANALYSES FOR SAMPLES FROM SET TWENTY-ONE, FROM THE INDIAN POINT POWER STATION, BUCHANAN, NEW YORK

[INSPECTION REPORT NO. 050-247/2006-007) [RFTA NO. 06-0011

Dear Mr. Kottan:

The Oak Ridge Institute for Science and Education (ORISE) received set 21, consisting of one water sample, associated with the Indian Point Power Station on February 7,2007. Sample analysis was initiated based on your previous direction for handling samples from this licensee. Sample identification and collection data for the samples addressed in this report are presented k Table 1. Gamma spectroscopy, the hard-to-detect betas (iron-55, nickel-63, and tritium), tecbnetiun-99, total radiostrontium, alpha spectroscopy, plutonium-241, and carbon-14 data are provided in Tables 2 through 8, respectively. The pertinent procedure references are provided in each specific table.

ORISE's Quality Control (QC) requirements were met for these analyses. The QC files are avadable for your review upon request. Additional reports will follow after the completion of the requested analyses.

ORISE has removed the Ni-59 data due to problems with the calculation associated with the concentration of this radionuclide. ORISE is discontinuing the reporting of Ni-59 data until this problem can be resolved.

My contact information is listed below, You may also contact Wade hey at 865576.9184 with any questions or comments.

Sincerely, Dale Condra, Manager Laboratory RDCEP1:bf Enclosures J. White, NRC Regionx 1-0 C:

T. Carter, NRC/FSME/D\\XWEP 7J8 E. Knox-Davin. NRC/FShE/T\\VFN 8A23 E. Abelquist, ORISE

hl. Roberts, NRC Region I File 1697 S. Kirk, ORISE v,

01 Distribution approval and concurrence :

Technical Management Team Member Quality Manager 1 Initials.

Voice: 865.241.3242 Far: 865.241.3248 E-mail: Dale.Condra @orau..org

TABLE 1 ORISE Sample ID 1697W0134" SAMPLE IDENTIFICATION AND COLLECTION DATA INDIAN POINT POWER STATION BUCHANAN, NEW YORK NRC Region I Collection Collection Sample ID Date Time ul-css-~ool) 1 /30/2007 11:45 I(

1697T~f0083~ 1 ul-css-(ool) 1 1/30/2007 I 11:45

?he W m the ORIS? sample idmuficahon represents a wafer ma-

'The h4 m the ORISE saniple idmuficiuon represents the filtered fracuon of ihe precehg witer sample Indian Point Power statim prqecrs/l697/Data Tables/2007-05-03 1st Intern Data Tables Ser 21

TABLE 2 ORISE Sample ID 1697W0134 NRC Region I Radionuclide Concentrations" Sample ID (pCi/L) co-58 CO-60 1.4 F 3.2b, 5.5 0.1 F 3.0, 5.1 cs-w4 cs-w7 0.0' F 3.0, 5.0 -4.1 F 5.7, 5.6 U1 -CSS-(OOl)

Indian Point rowel starion projectr/l697/Data Tables/2007-05-03 1st hte-Data Tables Set 21

TABLE 3

~

Radionuclide Concenuationsa @Ci/L)

ORISE NRC Region I Sample ID Sample ID Fe-5Sb Ni-63' H-3d 1697W0134 VI-CSS-(001)

-10 k 45', 78 5.9 f 7.5, 12.6 1,980 ? 330, 390 prajects/l697/Data Tables/2007-05-03 Isr Interim Data Tables Ser 21

TABLE 4 ORISE Sample ID 1697W0134 CONCENTRATIONS OF TECHNETIUM-99 (Tc-99)

IN A WATER SAMPLE BY LIQUID SCINTILLATION ANALYSIS AP5, REVISION 16; CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEW YORK NRC Region I Tc-99 Concentrations" Ul-CSS-(00l)

-1

? 1 5 ~, 27 Sample ID

@Ci/L)

Indian Point Power Station projects/l697/Data Tabied2007-05-03 1st Inte-Data Tables Ser 21

TABLE 5 ORISE NRC Region I Sample ID Sample ID 1697W0134 ul-css-(ool)

Radionuclide Concenuations, TPUs, and MDCs" @Ci/L) 248 k

43b

, 4.8 Inaim Point Power staoon pmjects/lG97/Data Tables/2007-05-03 1st Interim Data Tables Sct 21

TABLE 6 ORISE Sample ID 1697W0134 1697M0083 NRC Region I Sample ID Radionuclide Concentrations" @Ci/g of sediment in 100 mL or pCi/L for water)

Cm-242 Cm-243/244 Np-237 Am-241

-0.05 5 0.21', 0.41 0.00' f 0.09, 0.20

-0.20 ? 0.17, 0.40

-0.19 f 0.22, 0.49 0.02 t 0.14, 0.29 0.05 i 0.09, 0.18 2.02 f 0.41, 0.06 0.98 i 0.28, 0.06 Ul-CSS-(001) 0.00 5 0.02, 0.04 U.00 i 0.01, 0.02 0.00 i 0.02, 0.03 0.00 f 0.01, 0.03 Ul-CSS-(001)

Pu-239/240 U-234 U-238 Cm-242 Cm-243/244 Np-237 Pu-238 Am-241 U-234 U-238 Pu-238 Pu-239/240 0.01 f 0.02, 0.02 0.01

_+ 0.01, 0.02 0.01 i 0.01, 0.02 0.01 i 0.01, 0.01

TABLE 7 ORISE Sample ID 1697W0134 1697M0083 CONCENTRATIONS OF PLUTONIUM-241 IN A WATER SAMPLE BY LIQUID SCINTILLATION ANALYSIS APlO, REVISION 2; CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEW YORK Radionuclide Concentrations' @Ci/g of sediment in 100 mL or pCi/L for water)

NRC Region I Sample ID ul-css-(ool)

-11 32b 55 ul-css-(ool) 2.4 f

3.4 5.7 i

?he m c i6 after the comma.

bUnceitavluer represent the 959'0 confidence lmel, based on total propagated uncertwues pioiects/l697/Data Tabler/2007-05-03 1st Interim DataTables Set 21

TABLE 8 ORISE NRC Region I Radionuclide Concentrations, Sample ID Sample ID TPUs, and MDCs" @Ci/L)

_____-~--

1697WOl34 Ul-CSS-(00l)

-1.0 9.1b 15.5 Illdian Point Power Station projecrs/l697/Data Tablcr/Z007-05-03 l i t l n t e h Data Tables Set 21