ML090540135

From kanterella
Jump to navigation Jump to search
Ground Water Monitoring Well Information Table
ML090540135
Person / Time
Site: Indian Point  Entergy icon.png
Issue date: 01/10/2008
From:
- No Known Affiliation
To:
NRC Region 1
References
Download: ML090540135 (3)


Text

IPEC Ground Water Monitoring Well Information Table Dpl e ypSa l

Weell

D at el',

urrent Sample thellpDepth at Completion.

Frequencyj Unit 1 Wells MW-37 31 37-32 38 57 2/22/06 Nested Wells Quarterly

'37-57,'

55___

MW-42-49 41 80 3/22/06 Nested Wells Quarterly 42-78 74 MW-49-26 20 49-42 37 65 3/20/06 Nested Wells Quarterly.

49-65, 63 MW-50-42 32 67 3/13/06 Nested Wells Quarterly 50-66 64 S.MW-53-82

~~*; *.

72/

i 2 5 8/4/06 Neste'd Well's Qurterly

',"53-120/

110

________~"

V MW-54 37, 58, 123, 206 4/12/07 Waterloo Multilevel Quarterly 144, 173, 190 MW-655-24 V

19 55-35, 33

78 9 9/21/06,

Nested Wells........

..Quarterly

.s*55.4 49

_9_._

MW-56 53, 83 89 12/13/06 Nested Wells Semi-annual MW-5T-il '~.~

9 MW-57-20'

'17 47 8/31/06 Nested Wells Semi-annual MW,-57-45" 38' Unit 2 Wells MWm3o0 6,8"89

'"8/4/06',

Waterloo Multilevel,,

QUrterly MW-31 49, 63, 85 90 9/21/06 Waterloo Multilevel Quarterly
48,59,85,.

M -

111913 20,9/22/06 Waterloo Multilevel Quarterly

~190 MW-33 12 30 12/12/05 Open Borehole Annual MW,-35 12 30 Ope 1o2/6/05O rhol6 Annual:,..

MW-36-24 21 36-41 36 54 2/1/06 Nested Wells Quarterly 36-52 51 MW-37-22, 11 37-42' 38 57 2/22/06 Nested Wells Quarterly 37-57 55 V

~

MW-52 11, 18, 48, 64, 200 5/3/07 aterloo Multilevel with Annual MW-52 122, 162, 181 overburden wells MW-Ill.

19 19 2/24/00

  • ,Single,$dr6i6'e&lWell.

,.Se'-annual.

I Jan 10, 2008 Data are provided for the sole use of the recipient government officials and is subject to change.

Page 1 of 3

IPEC Ground Water Monitoring Well Information Table Sse~~pt' Dl ompete ofV 11 Current Sample I

_Unit 3 Wells 67, 84' 02 MW-39 12,

.183,19 200 4/25/07 Waterloo Multilevel Semni-annual MW-41-13 10 41-40 32 64 2/23/06 Nested Wells Semi-annual 41-63 62 MW-43-28 18" 62' 3/15/06

'Nested Wells Semi-annual 43-62 52 MW-44-67 65 105 3/15/06 Nested Wells Quarterly 4-102 94 6165

~

3/29/06 Nested Wells' Quarterly MW-46 20 30 2/22/06 Open Borehole Quarterly

::M W.58-26i!.

21 N e..............ted...........

MW-58-26 2170 9/26/06 WNesed Wells Semi-annual 5 ;,65.58 U3-T1 2

12/12/97 Core Hole Quarterly U32T2 1

12/,12/97,,

Core Hole Q"afterl, On-site Boundary Wells w40 27, 462' 1, 200.

4/30/07 Waterloo' Mujltilevl Qua~rterl 40, 79, 104, 200 5/2/07 Waterloo Multilevel Quarterly M -1 135, 163, 189 Off-site Boundary Wells LF02 130 140 1/26/01 6" Open rock h'l b 616

'eýtivr River Front Boundary Wells tW-0 35,~53, 72, M"W i60 135, 154, 176 200 4/18/07 Waterloo Multilevel Quarterly MW-62 18, 37, 53, 71, 200 411/07 Waterloo Multilevel with 2 Quarterly 92, 138, 182 overburden wells 92, 138, 185

__________________ 135:

Waterloo Multilevel wth 2 MW-63 1.12, 121, 163,

'-ý.

,200

'4/19/07

-. with Quarterly

~ ~ 74

,overburden wells MW-66 21,36 200 7/10/07 Overburden Quarterly

'V*;** 39, MW-67

.105,173,219, 350 8/27/07 Waterloo Multilevel Quarterly

. ".t..

276;323,'34P Jan 10, 2008 Data are provided for the sole use of the recipient government officials and is subject to change.

Page 2 of 3

IPEC Ground Water Monitoring Well Information Table

  • , 1':*Sami* 1 re-l c','-w*,,p, 1

ltfytetoWell..

'l*

CurrentSample Det

'X0 D

Bpt ate Gorn~plte, ait Competn Firrequn Miscellaneous Wells T1-U1-1 30 6/16/06 Single Screened Well None

.:~i~fiT1.Il 4U

~

N A Single Scr~eened'Well None MW-101 15 15 2/7/00 Single Screened Well None MW-103 30 26 2/9/00 Single-Screened Well_

None MW-I104 30 30 2/10/00 Single Screened Well None M______0__

20_____

20______

2/10/00__

jSingleý Screeed Well,~'

None ~

MW-I07 35 35 2/15/00 Single Screened Well Annual if~ MW-11IO 30 30 2 2/25-If)p SinI'e~sl ened Well ifffNone MW-112 24 24 2/26/00 Single Screened Well None U3-1 19 19

.4/11/96

'if.Single S'creened Well N.. one U3-2 15 i15 NA Single Screened Well None iyi U3ý-3

'~15

~

15 4/6/96 Sing( ý'Sicreened, ell

'None U3-4D 34 34 12/15/97 Single Screened Well None "U3-4S

.<18...

18'

' 12/12/97 Single Screened Well None 12 39 40 4/8/03 Single Screened Well None MW-48-2 40418//05-Srgd~b6rdl-el'Nn MW-48-23 18 40 2/2/06 Nested Wells None 48-37 36 MW-47-56 46 80 3/14/06 Nested Wells None 47-80 75 01 ~

' ~

50~

'~ ' i2/26/0O',

6" Open rockhole below LAF00 45 50' 12280 None LAF-003 45 55 12/28/00 6" Open rock hole below None 125' MW-59-32 26 59-45 39 70 10/4/06 Nested Wells None 59-68 64 MW45,.

48,18 800 12/4/06 ONentBorehle',

None.

MW-34 12 30 12/8/05 Open Borehole I

None Jan 10, 2008 Data are provided for the sole use of the recipient government officials and is subject to change.

Page 3 of 3