Forwards Rev 8A to Physical Security Plan,Describing Textual Changes Discussed by a Mcqueen & R Beatty.Rev Withheld (Ref 10CFR73.21)
ML20207K850
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 07/16/1986
From: Morgan H
SOUTHERN CALIFORNIA EDISON CO.
To: Martin J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
NUDOCS 8607300072
Download: ML20207K850 (1)


Text

b-

+<%

D%

Southem Califomia Edison Company  %[+, #

SAN ONOFRE NUCLEAR GENERATING STATION ,

PO BOX 128 SAN CLEMENTE. CALIFORNIA 92672 H E MORGAN TELEPHONE ST ATPDN MANAGE 8e f 7 ' 44 366 6241 JUL 161986 U. S. Nuclear Regulatory Conunission Office of Inspection and Enforcement Reglon V 1450 Maria Lane, Suite 210 Walnut Creek, California 94596-5368 Attention: Mr. J. B. Martin, Regional Administrator

Dear Sir:

Subject:

Docket Nos. 50-206, 50-361 and 50-362 Physical Security Plan Changes, Revision 8A San Onofre Nuclear Generating Station, Units 1, 2 and 3 (SONGS)

By letter dated March 3, 1986, Revision 8 to the " Physical Security Plan, San Onofre Units 1, 2 and 3" was forwarded to the U. S. Nuclear Regulatory Conynission (USNRC) for review pursuant to 10 CFR 50.54(p).

This letter responds to nodified Revision 8 textual changes implemented subsequent to the forwarding of Revision 8 to the USNRC for review. These modified changes, described in Revision 8A, were discussed between Mr. A.

McQueen, USNRC-V License Reviewer, and Mr. R. Beatty, SONGS Security Compllance, on June 24 and 25, 1986. Accordingly, pursuant to 10 CFR 50.54(p), enclosed are six (6) copies of the description of the Revision 8A textual chan3es discussed by Messrs. McQueen and Beatty.

The nodified changes described in the enclosure do not decrease 1he Safeguards effectiveness of this Plan.

The enclosure contains " Safeguards Information" and must be protected in accordance with the provisions of 10 CFR 73.21. Unauthorized disclosure could be subject to cIviI and criminai sanctions.

Sincerely, 8607300072 860716 PDR ADOCK 05000206 M{% e-F PDR Enclosure

cc
Director, Nuclear Reector Regulation, USNRC l F. R. Huey (USNRC Senior Resident inspector, SONGS) p\

i SAFEGUARDS INFORMATION ,

h acommun um numa w ma mm >g ,g

_