ML20209G342

From kanterella
Jump to navigation Jump to search
Forwards Table of 16 Affected Tube Locations in SG E089, Discovered During Cycle 10 Outage Insp,Which Were Probably Not Examined by Bobbin During Cycle Outage Insp
ML20209G342
Person / Time
Site: San Onofre 
Issue date: 07/15/1999
From: Scherer A
SOUTHERN CALIFORNIA EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9907190128
Download: ML20209G342 (3)


Text

SOUTHE RN CAtif ORNI A A. Edward Scherer EDISON

"=f-, m,,

anwisouines4 nod-cor ny July 15,1999 U. S. Nuclear Rego!atory Commission Document Control Desk Washington, D.C. 20555

Subject:

Docket No. 50-362 Update - Unit 3 Cycle 9 Steam Generator Inspection San Onofre Nuclear Generating Station, Unit 3

Reference:

(1)

Letter from G. T. Gibson (SCE) to Document Control Desk (USNRC), "Special Report: Inservice inspection of Steam Generator Tubes, San Onofre Nuclear Generating Station, Unit 3",

Docket Number 50-362, January 23,1998 (2)

Letter from A. E. Scherer (SCE) to Document Control Desk (USNRC), "Special Report: Inservice Inspection of Steam Generator Tubes, San Onofre Nuclear Generating Station, Unit 3",

Docket Number 50-362, April 28,1999 (3)

Letter from A. E. Scherer (SCE) to Document Control Desk (USNRC), " Update - Unit 2 Cycle 9 Steam Generator inspection San Onofre Nuclear Generating Station, Unit 2", Docket Number 50-361, March 25,1999 Gentlemen:

During the Unit 3 Cycle 9 outage, Southern California Edison (SCE) completed an inspection of steam generator tubes at San Onofre Nuclear Generating Station, Unit 3.

In Reference 1, SCE reported that 100% of the tubes in Steam Generator E089 were examined by bobbin probe. During the Unit 3 Cycle 10 outage, SCE discovered the recorded data from the Cycle 9 outage for 16 tubes was incorrect.

l 1

9907190128 990715 g

PDR ADOCK 05000362

[h' I

G P.O.lkn 128 San Clemente, CA 92674-0128 949 368-7501 Fax 949-368-7575 i

4 Document Control Desk July 15,1999 SCE now believes these tubes were probably not examined by bobbin during the Unit 3 Cycle 9 inspection. All 16 tubes were verified as no detectable discontinuity (NDD) or were identified with less than.20% through-wall wear during the Unit 3 Cycle 10 inspection (Reference 2).

SCE previously informed the NRC that the Unit 2 Cycle 9 midcycle inspection results had an error affecting 21 tubes (Reference 3). The Unit 2 Cycle 9 midcycle inspection error was discovered after completion of the Unit 3 Cycle 9 steam generator tube inspections. SCE's ongoing evaluation for Unit 2 will encompass this Unit 3

)

occurrence, and SCE will incorporate our findings into the applicable inspection i

processes. A table of the 16 affected tube locations in Steam Generator E089 is provided as an enclosure.

if you require any additional information, please contact myself or Mr. C. E. Williams at (949) 368-6707.

i Sincerely, Enclosure cc:

E. W. Merschoff, Regional Administrator, NRC Region IV L. Raghavan, NRC Project Manager, San Onofre Units 2 and 3 j

J. A. Sloan, NRC Senior Resident inspector, Units 2 and 3 j

i Document Control Desk July 15,1999 i

Table 1. E089 Tube Locations with incorrect Recorded Data Tubc t.oc0 tion Row Column 41 47 43 47 45 47 47 47 49 47 51 47 53 47 55 47 j

l 57 47 59 47 61 47 63 47 65 47 67 47 69 47 71 47 1

L