Informs That Licensee 990330 Response to GL 97-06 Provides Reasonable Assurance That Condition of Licensee Steam Generator Internals Is in Compliance with Current Licensing Bases for Plant
ML20217P711
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 10/26/1999
From: Raghavan L
NRC (Affiliation Not Assigned)
To: Ray H
SOUTHERN CALIFORNIA EDISON CO.
References
GL-97-06, TAC-MA0942, TAC-MA0943, NUDOCS 9910290373
Download: ML20217P711 (2)


Text

,

)(

'-1

~.' Mr.~ Harold B. Riy Executive Vice President "

. Southern California Edison Company L San Onofre Nuclear Generating Station October 26,_1999 P.O. Box 128 :

San Clemente, CA 92674-0128 SUBJECTi SAN ONOFRE NUCLEAR GENERATING STATION, UNITS 2 AND 3 - -

COMPLETION OF LICENSING ACTIVITY RE: GENERIC LETTER 97-06, DEGRADATION OF STEAM GENERATOR INTERNALS" _

(TAC NOS. MA0942 AND MA0943)

Dear Mr. Rayi On December 31,1997, the staff issued Generic Letter (GL) 97-06, " Degradation of Steam Generator Internals." The purpose of GL 97-06 was to obtain information that would enable the :

staff to verify that the condition of licensees' steam generator internals comply with and conform to the current licensing bases for their respective facilities.

By letter dated March 30,1998, you responded to GL 97-06. The staff's review of your response to the generic letter did not identify any new concerns with the condition of the steam generator internals. The staff did not identify any concerns with the inspection practices employed at your facility to detect degradation of steam generator internals. The staff, therefore, concludes that your response to the generic letter provides reasonable assurance that the condition of your_ steam generator internals is in compliance with the current licensing bases for your facility. _

1The detailed technical basis that supports the staff's determination for all facilities will be published in a NUREG report.- The expected publication date is December 1999. This completes the staff's effort on TAC No. MA0942 and MA0943 and the TA0s are closed.

1 If you have any questions regardhg this matter, please' write or call me at 301-415-1471.

- Sincerely, LORIGINAL. SIGNED BY:

L. Raghavan, Senior Project Manager, Section 2 QTE[Mg Proje

- Dms,ct Directorate IV & Decommissioning P PDR ton of Lice.ising Project Management .

Office of Nuclea. Reactor Regulation Docket Nos. 50 361 and 50-362 - .

9

'cc: See next page - - ,

n: "'

OGC ACRS

,- 5 S. Richards (clo)

G; Wunder _$)['tk

\

' PDIV-2 Rdg FileL S. Coffin -  : L. Smith,= RIV

  • Memo ESullivan to SBajwa To receive a copy of Inis document, indicate "c" in tne box -

OFFICE: PDIV-2/PM C PDIV-D/LA C *EMCB/SC PDIV-2/SC NAME 'LRaghava CJamerson Gh EJSullivanJr _ SDembek/

DATE D /Ll /99 lo / 74/99h 09/16/99 / O/7[/99 ~

DOCUMENT NAME: G:\PDIV-2\ SONGS \LTR0942.WPD gg OFFICIAL RECORD COPY ,

i t

g;-

d-San Onofre Nuclear Generating Station. Units 2 and 3 cc:

Mr. R. W. Krieger, Vice President Mayor Southern California Edison Company City of San Clemente i San Onofre Nuclear Generating Station 100 Avenida Presidio P. O. Box 128 - San Clemente, CA 92672 San Clemente, CA 92674-0128

. Mr. Dwight E. Nunn, Vice President Chairman, Board of Supervisors Southern California Edison Company County of San Diego San Onofre Nuclear Generating Station 1600 Pacific Highway, Room 335 P.O. Box 128 San Diego, CA 92101 San Clemente, CA 92674-0128  ;

I Alan R. Watts, Esq.

Woodruff, Spradlin & Smart 701 S. Parker St. No. 7000 Orange, CA 92668-4720 Mr. Sherwin Harris Resource Project Manager Public Utilities Department i City of Riverside 3900 Main Street Riverside, CA 92522 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Harris Tower # Pavilion 611 Ryan PN > Drive, C6te 400 l

Arlington, TX' 76011-8004 Mr. Michael Olson San Onofre Liaison l

' San Diego Gas & Electric Corapany P.O. Box 1831

{

4 San Diego, CA 92112-4150 Mr. Steve Hsu Radiologic Health Branen I

' State Department of Health Services l Post Office Box 942732 Sacramento, CA 94234 l Resident inspector / San Onofre NPS c/o U.S. Nuclear Regulatory Commission Post Office Box 4229 San Clemente, CA 92674 Jure 1999 l

1