Category:NOTICE OF VIOLATION OF A REGULATION
MONTHYEARML20217N1101998-04-21021 April 1998 Notice of Violation from Insp on 980208-0321.Violation Noted:Maint Personnel Did Not Follow Procedures & Conducted Work That Was Not Specified on Maint Work Order Which Was Outside Approved Personnel Protection Clearance Boundary ML20216E7931998-03-10010 March 1998 Notice of Violation from Insp on 971228-980207.Violation Noted:As of 980207,measures Not Correctly Implemented in That Proposed Vendor Manual Change for Sys Not Submitted to Reflect Lower Set Point Requirement for PCV 2T48-F466 ML20199F5061998-01-23023 January 1998 Notice of Violation from Insp on 971116-1227.Violation Noted:On 971118,4 H Reporting Requirement Was Not Met. Several Workers Involved in Unit 2 Outage Activities Signed Into RCA on Improper RWPs Between 970317-0411 ML20197F3571997-12-15015 December 1997 Notice of Violation from Insp on 971005-1115.Violation Noted:Licensee Failed to Label Properly Eight Spent Vacuum Filters Having Max Contact Dose Rates Ranging from 4.7 to 7.5 Rem Per Hour Which Were Suspended from Unit 1 Catwalk ML20199G9381997-12-0101 December 1997 Notice of Violation from Insp on 970406-0517.Violation Noted:On 970320,L Tillman Engaged in Deliberate Misconduct Causing Licensee to Be in Violation of TS 5.4,by Failing to Rept That Work Was Mistakenly Performed on Valve 2E51-F102 ML20199B8121997-11-0303 November 1997 Notice of Violation from Insp on 970817-1004.Violation Noted:Written Procedures Were Not Implemented on 970815 & Maintenance Work Was Completed Using Maintenance Work Order W/Inadequate Instructions ML20196J7051997-07-25025 July 1997 Notice of Violation from Insp on 970518-0628.Violation Noted:On 970609,steps 8.4.5 & 8.5.2 of Administration Control Procedure 30AC-OPS-001-OS,rev 15 Were Not Correctly Implemented ML20149H6581997-07-17017 July 1997 Notice of Violation from Insp on 970609-13.Violation Noted: Improperly Stored Matl,Which Had Potential to Impact Performance of Safety Related Equipment in Control Room, Was Identified ML20141F8641997-06-17017 June 1997 Notice of Violation from Insp on 970406-0517.Violation Noted:Listed Examples of Inadequate Testing Procedures Were Identified ML20140C2301997-05-30030 May 1997 Notice of Violation from Insp on 970428-0502.Violation Noted:Policies & Procedures Were Not Adequately Implemented in Employee Assistance Program Info & Released W/O Written Permission from Employee ML20148B8191997-05-0505 May 1997 Notice of Violation from Insp on 970223-0405.Violation Noted:Sections 8.12,8.13,4.2.2,4.7.7 & 8.8.3 of Procedure 30AC-OPS-001-OS Were Not Correctly Implemented ML20137F6301997-03-24024 March 1997 Notice of Violation from Insp on 970119-0222.Violation Noted:Design Control Requirements Not Translated Into Specifications ML20134L0771997-02-13013 February 1997 Notice of Violation from Insp on 961208-970118.Violation Noted:Written Procedures Were Not Implemented & Listed Examples of Failure to Implement Procedures for Radiation Control Activities Were Identified ML20133G9861997-01-0606 January 1997 Notice of Violation from Insp on 961027-1207.Violation Noted:Configuration Management & Adequate Design Control Measures Were Not Implemented ML20135C3061996-11-25025 November 1996 Notice of Violation from Insp on 960915-1026.Violation Noted:Licensee Failed to Verify That Opening Setpoints of reactor-bldg-to Suppression Chamber Vacuum Breaker Butterfly Valves 2T48-F310 & 2T48-F311 Less than 0.5 Psid ML20134D3741996-10-11011 October 1996 Notice of Violation from Insp on 960804-0914.Violation Noted:High Pressure Coolant Injection Valve,Gouges in Bonnet at Gasket Seating Area Were Removed by Machining & VT-3 re-inspection Was Not Completed ML20058J4521993-11-23023 November 1993 Notice of Violation from Insp on 931003-30.Violation Noted: Written Procedures Not Implemented Re TS 6.8.1a,covering Activities Delineated in Reg Guide 1.33,app A,Rev 2 ML20057C3381993-09-10010 September 1993 Notice of Violation from Insp on 930808-13.Violation Noted: Licensee Failed to Lock Access Point to Unit 1 TIP ML20057A4281993-08-30030 August 1993 Notice of Violation from Insp on 930704-0807.Violation Noted:Inadequate Procedural Guidance for Maint Activities on Primary Containment Isolation Valves 2B31-F019 & 2B31-F020 ML20056G7991993-08-30030 August 1993 Notice of Violation from Insp on 930726-30.Violation Noted: Dynamic Tests of MOV within Scope of GL 89-10,did Not Incorporate Requirements & Acceptance Limits for Determining Operability Prior to Returning Tested MOV Back to Svc ML20056D1151993-07-23023 July 1993 Notice of Violation from Insp on 930606-0703.Violation noted:1B Standby Gas Treatment Train Inoperable on 930502 Until 930505 ML20127K3111993-01-0808 January 1993 Notice of Violation from Insp on 921207-11.Violation Noted: Sludge Was Disposed of from Onsite Sewage Treatment Facility by Spreading Sludge on licensee-owned Land W/O Having Obtained Approval of Procedures for Method of Disposal ML20058K2291990-11-30030 November 1990 Notice of Violation from Insp on 901021-1117.Violation Noted:Failure to Obtain Required Grab Samples When Particulate Monitoring Sys Became Inoperable ML20062F8311990-11-14014 November 1990 Notice of Violation from Insp on 900915-1020.Violation Noted:Failure to Properly Set Main Stream Line Radiation Monitor Trip Settings & Setpoint Controls ML20246N8271989-08-18018 August 1989 Notice of Violation from Insp on 890515-19,0605-09 & 19. Violations Noted:Sampling Methodology Did Not Assure Representative Samples of Emergency Diesel Generator Fuel Oil Storage Tanks ML20245D4921989-06-15015 June 1989 Notice of Violation from Insp on 890227-0317.Violation Noted:Procedure Did Not Provide for Incorporation of Vendor Recommendations in Maint Procedures for 4,160-volt Ac metal- Clad Switchgear ML20246N8751989-05-0808 May 1989 Notice of Violation from Insp on 890321-0421.Violation Noted:During 880408-890222,surveillance Checks of A.C Circuits 26 & 29 Performed on Weekly Rather than Daily Basis Due to Error in Procedure ML20245A2091989-04-12012 April 1989 Notice of Violation from Insp on 890225-0320.Violation Noted:Procedure Did Not Caution Against Consequences of Sys Cooldown or Provide Adequate Instructions to Prevent Rapid Sys Filling ML20129K1521988-12-21021 December 1988 Notice of Violation from Insp on 881031-1104.Violation Noted:On 881031,licensee Failed to Perform Radiation Surveys of Areas After Repositioning Contaminated Tools Having Dose Rates of Approximately 100 Mrem Per Hour ML20206A8591988-11-0808 November 1988 Notice of Violation from Insp on 880924-1021.Violation Noted:Failure to Follow Written Procedures When Adding Water to Suppression Pool on 880927 & While Attempting to Perform Local Leak Rate Test on Core Spray Sys Valve on 881005 ML20155A2061988-09-22022 September 1988 Notice of Violation from Insp on 880723-0819.Violations Noted:Procedure 34SO-N34-0081N Inadequate & Did Not Provide Instructions for Swapping of Lube Oil Coolers ML20153F2241988-08-23023 August 1988 Notice of Violation from Insp on 880620-24.Violation Noted: Insp of Halon Sys Protecting Remote Shutdown Panel Not Conducted Between 870819 & 1120 ML20151L9301988-07-21021 July 1988 Notice of Violation from Insp on 880521-0624.Violation Noted:Sys Operating Procedure for Diesel Generator Bldg Ventilation Sys Found to Be Inadequately Established & Implemented ML20195J5461988-06-17017 June 1988 Notice of Violation from Insp on 880509-20.Violations Noted: Failure to Maintain Appropriate Quality Stds for Installation of Model 206-380 Asco Solenoid Valves & NRC Inspector Found Eight Pages of Tech Spec Missing ML20195E3751988-06-10010 June 1988 Notice of Violation from Insp on 880418-20 & 0423-0520. Violation Noted:Plant Personnel Backfilled Instrument Ref Leg for Unit 1 Reactor Water Level Transmitters 1B21-N080C & 1B21-N080D W/O Specific Instructions or Procedural Guidance IR 07100130/20120111988-05-31031 May 1988 Notice of Violation from Insp on 871130-1211.Violations Noted:Adequate Testing Not Performed to Ensure Valve Would Isolate on High Differential Flow Isolation Actuation Signal ML20154Q5031988-05-16016 May 1988 Notice of Violation from Insp on 880326-0422.Violation Noted:Torus to Drywell Vacuum Breaker Test Solenoid Valves Incapable of Holding Pressure During Required Local Leak Rate Testing Due to Design Deficiencies ML20151M3061988-04-12012 April 1988 Notice of Violation from Insp on 880220-0325.Violations Noted:Failure to Perform Functional Test of APRM Flow Ref Thermal Power & APRM Downscale Trips & Failure to Follow Surveillance Procedures 57SV-SUV-007-2S & 57SV-D11-016-1S ML20148H6971988-03-10010 March 1988 Notice of Violation from Insp on 880123-0219.Violations Noted:On 880209,plant Operated W/Only One APRM Channel & in Oct of 1987 Vacuum Breakers 1T48-342C,E & F Failed to Test Properly Due to Inadequate Maint Work Order Instructions ML20237E3301987-12-18018 December 1987 Notice of Violation from Insp on 871116-20.Violations Noted: Failure to Implement Documentation & Records Mgt Provisions of Fire Protection Program & Failure to Implement Fire Brigade Drill Provisions of Fire Protection Program ML20236T9381987-11-25025 November 1987 Notice of Violation from Insp on 870926-1026.Violation Noted:Failure to Conduct Reviews of Caution Tag Index/Audit Sheets During Months of May,June & Sept 1987 ML20236R3581987-11-18018 November 1987 Notice of Violation from Insp on 871026-30.Violations Noted: Failure to Take Suitable Measurements to Detect & Evaluate Airborne Radioactivity Hazards & Failure to Maintain Control & Account for SNM ML20235V5431987-10-0808 October 1987 Notice of Violation from Insp on 870831-0904.Violation Noted:Acceptance Criteria Inadequately Specified for Pressure Switch 2E41-N752 in Calibr Procedure 57CP-CAL-067-2S ML20235W0501987-10-0707 October 1987 Notice of Violation from Insp on 870829-0925.Violation Noted:Licensee Failed to Promptly Revise Surveillance Procedure to Reflect Requirements of Amend 71 to Tech Specs ML20235C4491987-09-17017 September 1987 Notice of Violation from Insp on 870801-28.Violation Noted: No Disposal Records Available for Byproduct Matls,Sn 113-35, Mx 340-342 & 344-348 & Procedural Requirements for Exempt/ Nonexempt Matl Determinations Not Met ML20238A3031987-09-0202 September 1987 Notice of Violation from Insp on 870720-24.Violations Noted: Assignment of Personnel to Emergency Response Organization W/O Annual Retraining in Required Emergency Preparedness Training Modules ML20237K6611987-08-18018 August 1987 Notice of Violation from Insp on 870704-31.Violation Noted: Failure to Provide Adequate Procedures for Repair of Local Power Range Monitoring Sys ML20236M2161987-08-0303 August 1987 Notice of Violation from Insp on 870622-26.Violation Noted: as-built Drawing Discrepancies in Weld Symbol & Base Plate Thickness for Pipe Supports ML20236B3771987-07-23023 July 1987 Notice of Violation from Insp on 870629-0702.Violation Noted:Failure to Have Written Procedures to Cover Insp of Mechanical Snubbers After Severe Dynamic Event - Paragraph 5.a ML20235U5231987-07-15015 July 1987 Notice of Violation from Insp on 870527-0703.Violations Noted:Licensee Failed to Provide Adequate Procedures for Performance of Excess Low Check Valve Surveillance Testing & Procedures to Fill RHR Sys Loop B Inadequate 1998-04-21
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000321/19990091999-10-0707 October 1999 Insp Repts 50-321/99-09 & 50-366/99-09 on 990607-11 & 0823- 27.One Violation Being Treated as Ncv.Major Areas Inspected: Maint & Engineering IR 05000321/19990051999-09-16016 September 1999 Insp Repts 50-321/99-05 & 50-366/99-05 on 990711-0821.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000321/19990041999-08-0404 August 1999 Insp Repts 50-321/99-04 & 50-366/99-04 on 990530-0710.One Violation Noted & Being Treated as Ncv.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000321/19990101999-07-20020 July 1999 Insp Repts 50-321/99-10 & 50-366/99-10 on 990616-25.One Violation Occurred & Being Treated as Ncv.Major Areas Inspected:Aspects of Licensee Operations,Maint,Problem Identification & Resolution & Corrective Actions IR 05000321/19990031999-06-25025 June 1999 Insp Repts 50-321/99-03 & 50-366/99-03 on 990418-0529.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support PNO-II-99-025, on 990615,CR Operators Manually Shutdown Unit 2 Reactor from 41% Power,Due to Decreasing Condenser Vacuum. Cause of Decreasing Vacuum Has Not Been Determined.All Rods Installed as Required & All Safety Sys Functioned Properly1999-06-17017 June 1999 PNO-II-99-025:on 990615,CR Operators Manually Shutdown Unit 2 Reactor from 41% Power,Due to Decreasing Condenser Vacuum. Cause of Decreasing Vacuum Has Not Been Determined.All Rods Installed as Required & All Safety Sys Functioned Properly PNO-II-99-016, on 990505,Hatch Unit 2 Had Main Generator Trip Form 98% Power,Due to Electrical Fault.Licensee Continuing Investigation Has Been Hampered Due to Inclement Local Weather Conditions.Plant Being Depressurized1999-05-0707 May 1999 PNO-II-99-016:on 990505,Hatch Unit 2 Had Main Generator Trip Form 98% Power,Due to Electrical Fault.Licensee Continuing Investigation Has Been Hampered Due to Inclement Local Weather Conditions.Plant Being Depressurized IR 05000321/19990021999-05-0606 May 1999 Insp Repts 50-321/99-02 & 50-366/99-02 on 990307-0417.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000321/19990011999-04-0202 April 1999 Insp Repts 50-321/99-01 & 50-366/99-01 on 990124-0306.Non- Cited Violations Identified.Major Areas Inspected:Maint, Operations & Plant Support IR 05000321/19980091999-02-24024 February 1999 Insp Repts 50-321/98-09 & 50-366/98-09 on 981213-990123.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support.Rept Covers Insp in Health Physics & Independent Spent Fuel Storage IR 05000321/19980071998-12-29029 December 1998 Insp Repts 50-321/98-07 & 50-366/98-07 on 981101-1212.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000321/19980061998-11-24024 November 1998 Insp Repts 50-321/98-06 & 50-366/98-06 on 980920-1031. Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000321/19980051998-10-15015 October 1998 Insp Repts 50-321/98-05 & 50-366/98-05 on 980802-0919.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support.Insp Also Included Insps by Regional Maint & Emergency Preparedness PNO-II-98-040, on 980917,licensee Declared Notification of Unusual Event Based on Transport of Two Injured & Potentially Contaminated Individuals to Local Hospital.Two Individuals Found Not to Have Sustained Serious Injury1998-09-18018 September 1998 PNO-II-98-040:on 980917,licensee Declared Notification of Unusual Event Based on Transport of Two Injured & Potentially Contaminated Individuals to Local Hospital.Two Individuals Found Not to Have Sustained Serious Injury IR 05000321/19980041998-08-21021 August 1998 Insp Repts 50-321/98-04 & 50-366/98-04 on 980621-0801.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support.Rept Includes Results of Insp by Regional Engineering & Safeguard IR 05000321/19980031998-07-14014 July 1998 Insp Repts 50-321/98-03 & 50-366/98-03 on 980503-0620.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support,Including Fire Hazards Analysis Requirements IR 05000321/19980021998-06-0101 June 1998 Insp Repts 50-321/98-02 & 50-366/98-02 on 980322-0502.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20217N1311998-04-21021 April 1998 Insp Repts 50-321/98-01 & 50-366/98-01 on 980208-0321. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support ML20217N1101998-04-21021 April 1998 Notice of Violation from Insp on 980208-0321.Violation Noted:Maint Personnel Did Not Follow Procedures & Conducted Work That Was Not Specified on Maint Work Order Which Was Outside Approved Personnel Protection Clearance Boundary ML20216E7931998-03-10010 March 1998 Notice of Violation from Insp on 971228-980207.Violation Noted:As of 980207,measures Not Correctly Implemented in That Proposed Vendor Manual Change for Sys Not Submitted to Reflect Lower Set Point Requirement for PCV 2T48-F466 ML20216E7981998-03-10010 March 1998 Insp Repts 50-321/97-12 & 50-366/97-12 on 971228-980207. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20199F5061998-01-23023 January 1998 Notice of Violation from Insp on 971116-1227.Violation Noted:On 971118,4 H Reporting Requirement Was Not Met. Several Workers Involved in Unit 2 Outage Activities Signed Into RCA on Improper RWPs Between 970317-0411 ML20199F5411998-01-23023 January 1998 Insp Repts 50-321/97-11 & 50-366/97-11 on 971116-1227. Violations Noted.Major Areas Inspected:Operations, Engineering,Maint & Plant Support ML20197F3571997-12-15015 December 1997 Notice of Violation from Insp on 971005-1115.Violation Noted:Licensee Failed to Label Properly Eight Spent Vacuum Filters Having Max Contact Dose Rates Ranging from 4.7 to 7.5 Rem Per Hour Which Were Suspended from Unit 1 Catwalk ML20197F3931997-12-15015 December 1997 Insp Repts 50-321/97-10 & 50-366/97-10 on 971005-1115. Violations & Deviations Noted.Major Areas Inspected:Maint, Engineering,Plant Support & Operations Re Health Physics Concern ML20197F3711997-12-15015 December 1997 Notice of Deviation from Insp on 971005-1115.Deviation Noted:Unit 2 Was Restarted on 940428 Following Spring Refueling Outage Repairs/Replacement Work Performed Under Design Change Request 96-006 ML20199G9381997-12-0101 December 1997 Notice of Violation from Insp on 970406-0517.Violation Noted:On 970320,L Tillman Engaged in Deliberate Misconduct Causing Licensee to Be in Violation of TS 5.4,by Failing to Rept That Work Was Mistakenly Performed on Valve 2E51-F102 PNO-II-97-060, on 971120,plant Operators Manually Scrammed Reactor from 70% Power Due to Damage to Condensate Sys. Flexible Bellows on 2A Condensate Booster Pump Was Overpressurized.Licensee Initiate Controlled Shutdown1997-11-21021 November 1997 PNO-II-97-060:on 971120,plant Operators Manually Scrammed Reactor from 70% Power Due to Damage to Condensate Sys. Flexible Bellows on 2A Condensate Booster Pump Was Overpressurized.Licensee Initiate Controlled Shutdown ML20199B8121997-11-0303 November 1997 Notice of Violation from Insp on 970817-1004.Violation Noted:Written Procedures Were Not Implemented on 970815 & Maintenance Work Was Completed Using Maintenance Work Order W/Inadequate Instructions ML20199B8221997-11-0303 November 1997 Insp Repts 50-321/97-09 & 50-366/97-09 on 970817-1004. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000321/19970081997-10-0303 October 1997 Insp Repts 50-321/97-08 & 50-366/97-08 on 970818-22.No Violations Noted.Major Areas Inspected:Observation & Evaluation of Biennial Emergency Preparedness Exercise for Plant IR 05000321/19970071997-09-11011 September 1997 Insp Repts 50-321/97-07 & 50-366/97-07 on 970629-0816.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maint & Plant Support ML20196J7431997-07-25025 July 1997 Insp Repts 50-321/97-05 & 50-366/97-05 on 970518-0628. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support ML20196J7051997-07-25025 July 1997 Notice of Violation from Insp on 970518-0628.Violation Noted:On 970609,steps 8.4.5 & 8.5.2 of Administration Control Procedure 30AC-OPS-001-OS,rev 15 Were Not Correctly Implemented ML20149H6651997-07-17017 July 1997 Insp Repts 50-321/97-06 & 50-366/97-06 on 970609-13. Violations Noted.Major Areas Inspected:Licensee Corrective Action Program Including Problem Resolution,Operating Experience Feedback Programs & self-assessment Activities ML20149H6581997-07-17017 July 1997 Notice of Violation from Insp on 970609-13.Violation Noted: Improperly Stored Matl,Which Had Potential to Impact Performance of Safety Related Equipment in Control Room, Was Identified ML20141F8841997-06-17017 June 1997 Insp Repts 50-321/97-03 & 50-366/97-03 on 970406-0517. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20141F8641997-06-17017 June 1997 Notice of Violation from Insp on 970406-0517.Violation Noted:Listed Examples of Inadequate Testing Procedures Were Identified ML20140C2301997-05-30030 May 1997 Notice of Violation from Insp on 970428-0502.Violation Noted:Policies & Procedures Were Not Adequately Implemented in Employee Assistance Program Info & Released W/O Written Permission from Employee ML20140C2441997-05-30030 May 1997 Insp Repts 50-321/97-04 & 50-366/97-04 on 970428-0502. Violations Noted.Major Areas Inspected:Fitness for Duty, Access Authorization & Physical Security Program for Power Reactors ML20148B8191997-05-0505 May 1997 Notice of Violation from Insp on 970223-0405.Violation Noted:Sections 8.12,8.13,4.2.2,4.7.7 & 8.8.3 of Procedure 30AC-OPS-001-OS Were Not Correctly Implemented IR 05000321/19970021997-05-0505 May 1997 Insp Repts 50-321/97-02 & 50-366/97-02 on 970223-0405. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000321/19973001997-04-0404 April 1997 NRC Operator Licensing Exam Repts 50-321/97-300 & 50-366/97-300 on 970314-20.Exam Results:All Candidates Passed Exam IR 05000321/19970991997-04-0404 April 1997 SALP Repts 50-321/97-99 & 50-366/97-99 for 950528-970222 ML20137F6301997-03-24024 March 1997 Notice of Violation from Insp on 970119-0222.Violation Noted:Design Control Requirements Not Translated Into Specifications ML20137F6451997-03-24024 March 1997 Insp Repts 50-321/97-01 & 50-366/97-01 on 970119-0222. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support PNO-II-97-017, on 970312,licensee Reported Employee Collapses Onsite.First Aid Administered Until Ambulance Arrived. Employee Transported to Appling County General Hosp in Baxley,Ga & Pronounced Dead.Autopsy Will Be Performed1997-03-13013 March 1997 PNO-II-97-017:on 970312,licensee Reported Employee Collapses Onsite.First Aid Administered Until Ambulance Arrived. Employee Transported to Appling County General Hosp in Baxley,Ga & Pronounced Dead.Autopsy Will Be Performed ML20134L0771997-02-13013 February 1997 Notice of Violation from Insp on 961208-970118.Violation Noted:Written Procedures Were Not Implemented & Listed Examples of Failure to Implement Procedures for Radiation Control Activities Were Identified PNO-II-97-006A, on 970129,plant Shutdown Due to Primary Pressure Boundary Leakage Update.Licensee Continuing to Cold Shutdown Conditions to Perform Addl Corrective Maint Activities.Resident Inspectors Monitoring Repair Actions1997-01-30030 January 1997 PNO-II-97-006A:on 970129,plant Shutdown Due to Primary Pressure Boundary Leakage Update.Licensee Continuing to Cold Shutdown Conditions to Perform Addl Corrective Maint Activities.Resident Inspectors Monitoring Repair Actions PNO-II-97-006, on 970129,Unit 1 Declared Notice of Unusual Event for Reactor Coolant Pressure Boundary Leakage,As Defined in TS 3.4.4.Resident Inspectors on Site Monitoring Licensee Actions.State of Ga Notified1997-01-29029 January 1997 PNO-II-97-006:on 970129,Unit 1 Declared Notice of Unusual Event for Reactor Coolant Pressure Boundary Leakage,As Defined in TS 3.4.4.Resident Inspectors on Site Monitoring Licensee Actions.State of Ga Notified 1999-09-16
[Table view] |