1 DUKE POWER COMPANY Powra Butt.otwo 422 Sourn Caracu STazzi, Cruntortz. N. C. asa4a

--

  • - ,,

WIL LI A04 0. PAmata, sm. Tc.c.-m a c. 7c.

v.c c P.c.. . ., July 2, 1979 373-4ce3 _

Sican Peoowet.o. .k5

'

Do

-Mr. J. P. O'Reilly, Director U.S. Nuclear Regulatory Commission

,, 3'

,

.

Region II ..

101 Marietta Street, Suite 3100 cn Atlanta, GA 30303 c:

Re: RII:JPO ~

50-369, 50-370 -

IE Bulletin 79-03

Dear Mr. O'Reilly:

Duke Power Company's response to IE Bulletin was transmitted to Region II on May 15, 1979. The attached information supplements the original response by identifying the application of the subject piping at McGuire Nuclear Station.

Very truly yours, b , n.

William O. Parker, Jr.

GAC/sch Attachment

%o* gnoon,h q ,.

3

[+4 k.

1 th MW 7008270.307  %,%n #+, gQg(9Q

'

. - __ - ar

.

.

McGuire Nuclear Station IE Bulletin 79-03 Supplemental Information

.

Item 2 Application of pipe manufactured by Youngstown Welding and Engineering Company at McGuire Nuclear Station Heat No. System (s) 313509 Unit 2 - Containment Spray (NS)

(8" Sch. 10) Unit 2 - Refueling Water (FW) 724223 Unit 2 - Decay Heat Removal (ND)

(12" Sch. 40) 724215 Unit 2 - Containment Spray (NS)

(8" Sch. 10) Unit 2 - Chemical 6 Volume Control (NV)

Unit 2 - Spent Fuel Cooling (KF)

All of the above piping is located either in the Auxiliary Building or the Reactor Building.

.