ML16152A953

From kanterella
Jump to navigation Jump to search
Forwards Proprietary DPC-NE-2000P-A & Nonproprietary DPC-NE-2000-A, DCHF-1 Correlation for Predicting Heat Flux in Mixing Vane Grid Fuel Assemblies. Proprietary Rept Withheld
ML16152A953
Person / Time
Site: Oconee, Mcguire, Catawba, McGuire  
Issue date: 05/02/1990
From: Tucker H
DUKE POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML16152A954 List:
References
NUDOCS 9005080021
Download: ML16152A953 (5)


Text

ACCELERATED DISTRIBUTION DEMONSTRATION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9005080021 DOC.DATE: 90/05/02 NOTARIZED: NO DOCKET #

FACIL:50-269 Oconee Nuclear Station, Unit 1, Duke Power Co.

05000269 50-270 Oconee Nuclear Station, Unit 2, Duke Power Co.

05000270 50-287 Oconee Nuclear Station, Unit 3, Duke Power Co.

05000287 50-413 Catawba Nuclear Station, Unit 1, Duke Power Co.

05000413 50-414 Catawba Nuclear Station, Unit 2, Duke Power Co.

05000414 R

50-369 William B. McGuire Nuclear Station, Unit 1, Duke Powe 05000369 50-370 William B. McGuire Nuclear Station, Unit 2, Duke Powe 05000370 I

AUTH.NAME AUTHOR AFFILIATION TUCKER,H.B.

Duke Power Co.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Docu 6 f6oon 'oDesk)

S

SUBJECT:

Forwards proprietary DPC-NE-2000P-A & nonproprietary DPC-NE-2000-A, "DCHF-1 Correlation for Predicting...."

DISTRIBUTION CODE: AP01D COPIES RECEIVED:LTR/

ENCL -

SIZE:

O A

TITLE: Proprietary Review Distribution -

OperaEing Reactor D

NOTES: PDR s AM S

cy to R-.

05000413

=L1 ys(fDT

't SAR ASLB

.05000414 D

S RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD2-3 LA 1

1 PD2-3 PD 1

1 WIENS,L 3

3 JABBOUR,K 3

3 HOOD,D 3

3 INTERNAL: ACRS 4

6-'

AEOD/DOA 1

1 AEOD/. DSzP-FPAB 1

1 OGC/HDS2 1

0 01 1

1 EXTERNAL: LPDR 3

0 NRC PDR 1

NOTES:

a R

4 IV D

S A

D D

NOTE TO ALL "RIDS" RECIPIENTS:

S PLEASE ]HELP US TO REDUCE WASTE! CONTACT THE.DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

2E TOTAL NUMBER OF COPIES REQUIRED: LTTR

-R-e-ENCL

Duke Power Company HAL B Tucker P 0. Box 33198 Vice President Charlotte, N.C. 28242 Nuclear Production (704)373-4531 DUKE POWER May 2, 1990 U. S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D. C. 20555

Subject:

McGuire Nuclear Station Docket Numbers 50-369 and -370 Catawba Nuclear Station Docket Numbers 50-413 and -414 Oconee Nuclear Station Docket Numbers 50-269, -270, and -287 Approved Versions (Proprietary and Non-Proprietary) of Topical Report DPC-NE-2000 On August 17, 1989, the NRC staff issued the Safety Evaluation Report (SER) for Duke Power Company's Topical Report DPC-NE-2000P, "DCHF-1 Correlation for Predicting Critical Heat Flux in Mixing Vane Grid Assemblies." As instructed in the cover letter which accompanied the SER, Duke has reprinted the report, including the SER, in proprietary and non-proprietary versions.

Enclosed are 20 copies of each, designated DPC-NE-2000P-A and DPC-NE-2000-A, respectively.

If you have any questions, please call Scott Gewehr at (704) 373-7581.

Very truly yours, Hal B. Tucker SAG/219/lcs FDR ADOCK 05000269 F'

FDC

U. S. Nuclear Regulatory Commission May 2, 1990 Page 2 xc:

(W/Attachments)

Darl S. Hood, Project Manager Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Dr. Kahtan Jabbour, Project Manager Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Mr. L. A. Wiens, Project Manager Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Mr. P. H. Skinner Sr. Resident Inspector Oconee Nuclear Station Mr. W. T. Orders Senior Resident Inspector Catawba Nuclear Station Mr. P. K. VanDoorn Senior Resident Inspector McGuire Nuclear Station Mr. S. D. Ebneter, Regional Administrator U. S. Nuclear Regulatory Commission -

Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323

U. S. Nuclear Regulatory Commission May 2, 1990 Page 3 bxc:

(W/O Attachments)

R. L. Gill, Jr.

P. F. Guill J. S. Warren R. G. Morgan K. S. Canady R. M. Gribble GS-801.01

Duke Power Company HAL B. Tucker P O. Box 33198 Vice President Charlotte, N.C. 28242 Nuclear Production (704)373-4531 DUKE POWER May 2, 1990 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555

Subject:

McGuire Nuclear Station Docket Numbers 50-369 and -370 Catawba Nuclear Station Docket Numbers 50-413 and -414 Oconee Nuclear Station Docket Numbers 50-269, -270, and -287 Approved Versions (Proprietary and Non-Proprietary) of Topical Report DPC-NE-2000 On August 17, 1989, the NRC staff issued the Safety Evaluation Report (SER) for Duke Power Company's Topical Report DPC-NE-2000P, "DCHF-1 Correlation for Predicting Critical Heat Flux in Mixing Vane Grid Assemblies." As instructed in the cover letter which accompanied the SER, Duke has reprinted the report, including the SER, in proprietary and non-proprietary versions.

Enclosed are 20 copies of each, designated DPC-NE-2000P-A and DPC-NE-2000-A, respectively.

If you have any questions, please call Scott Gewehr at (704).373-7581.

Very truly yours, Hal B. Tucker SAG/219/lcs

~r~~C)3j,1 9005Ci7T_

FDR ADOCK 05000269 P

FIC*