r-

{

l g

Duke Energy Corporation McGuire Nudear Station 12700 llagers Ferry Road Huntersville, NC 28078-9340

1. B. Barron (704) 875-4800 OFFICE

)Vice hesident (704) 875-4809 fax April 19, 1999 U.

S.

Nuclear Regulatory Commission Document Control Desk Washington, D.C.

20555

Subject:

McGuire Nuclear Station Docket Nos. 50-369 Unit 1 Steam Generators EOC-12 Refueling Ottage Pursuant to Technical Specification 5.6.8 part b, the following information is submitted:

a. The following quantity of tubes were inspected from either side of the generator.

Tubes Inspected Tubes Inspected Steam Generator Full Length Partial Length A

6290 342 B

6334 298 Nd'Of C

6335 294 D

6306 323

b. The following information is submitted concerning tube indications of imperfections.

(The attached list identifies the tubes with imperfections and the location and size of the imperfections.)

Steam Generator Attachment A

1 B

2 C

3 D

4

'I O O ':.' 3

~

9904270103-990419 PDR ADOCK 05000369 P

PDR u

w

s i

g.

U.

S.

Nuclear Regulatory Commission April 19, 1999 Page 2

c. The following tubes were removed from service by P ugging.

l Steam Generator Attachment A

5 B

6 C

7 D

8 Questions regarding this submittal should be directed to Kay i

Crane, McGuire Regulatory Compliance, at (704) 875-4306.

1 Sincerely, H.

B.

Barron, Vice President McGuire Nuclear Station I

Attachment

e i

U.S. Nuclear Regulatory Commission Aptil 19, 1999 Page 3 cc:

Mr.

L. A Reyes Regional Administrator, Region II U.

S.

Nuclear Regulatory Commission 61 Forsyth St.,

SW, Suite 23T85 Atlanta, Georgia 30323-Mr.

F.

Rinaldi, Project Manager Office of Nuclear Reactor Regulation U.

S. Nuclear Regulatory Commission Washington, D.C.

20555 Mr. Scott Shaeffer Senior NRC Resident Inspector McGuire Nuclear Station i

3.

1 U.-S.

Nuclear Regulatory Commission Apiil 19, 1999 Page 4 bxc: EC050-ELL RGC File l

1 i

t_-

'4************~

.FTI TUBAN II'(Version,2.3) 04/05/1999 11:35:22 McGuire N.S.

Unit One Replactmunt Sfo A 06/98 RFO BOBBIN,MRPC C/L SI,MRPC H/L SI,MRPC UBEND SI

' ATTACHMENT #1 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGA ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION s

2 17 06/98 BOBBIN.

ODI 1

0.67 02H

+22.49 06/98 MRPC H/L SI VOL 0.49 02H

+22.27 2 137 06/98 BOBBIN ODI 5

0.23 01C

+18.86 06/98 MRPC C/L SI-VOL' O.65 01C

+18.86

-3 16 06/98 BOBBIN ODI 1

0.23 03H-

+30.87 06/98 MRPC H/L SI VOL 0.25 03H

+30.42 6 39 06/98 BOBBIN ADI 0.15 02C

+16.05 6 '41 06/98 BOBBIN ADI 0.71 08H

+37.06 6 47 06/98 BOBBIN ODI 3-0.07 08C

+21.07 7 52 06/98 BOBBIN ODI 6

0.30 01C

+14.21 06/98 MRPC C/L SI VOL 0.37.01C

+13.67 8 59 06/98 BOBBIN ODI 1

0.31 02H

+31.60 06/98. MRPC H/L SI VOL 0.28 02H

+31.22 12 29 06 98 BOBBIN ODI 1

0.11 04C

+11.44

06 98 BOBBIN ODI-1 0.19 03C

+30.72 06/98 BOBBIN ODI 4

0.46 08H

+33.87 06/98 MRPC C/L SI VOL 0.27 04C

+31.33 06/98 MRPC C/L SI VOL 0.39 04C

+11.46 06/98 MRPC H/L SI VOL 0.39 08H

+33.49

-12 59 06/98 BOBBIN NQI 0.34 CBH

+5.39 15 128 06/98 BOBBIN ODI 1

0.14 08C

+24.80 22 31 06/98 BOBBIN ODI 1

0.30 06C

+7.55 06/98 BOBBIN ODI 7

0.10 08H

+15.18 06/98 BOBBIN ODI 10 0.23 06C

+32.54 06/98 MRPC C/L SI' VOL 0.31 06C

+7.31 06/98 MRFC C/L SI VOL O.38 06C

+32.44 06/98 MRPC H/L SI VOL 0.17 08H

+15.10 22 37 06/98 BOBBIN ODI 7

0.23 02C

+36 15 22 71 06 98 BOBBIN ODI 17 0.36 01C

+22.48 23 30 06 98 BOBBIN ODI 6

0.28 OSC

+14.58

~ 06 98 BOBBIN.

ODI 10 0.14 OSC

+16.61 06/98 MRPC C/L SI VOL 0.15 05C

+16.67 06/98 MRPC C/L SI VOL 0.31 05C

+14.73 24 39 06/98 BOBBIN ODI 1

0.25 06C

+37.31 06/98 BOBBIN ODI 1

0.42 05H

+7.77 06/98 MRPC C/L SI VOL 0.17 06C

+38.95 06/98 MRPC C/L SI VOL 0.26 06C

+36.99 06/98 MRPC H/L SI VOL 0.36 05H

+7.57 06/98 MRPC H/L SI VOL 0.42 05H

+7.02

-24 67 06/98 BOBBIN ODI 1

0.37 05H

+19.74 06/98 MRPC H/L SI VOL 0.21 05H

+19.89 24 69 06/98. BOBBIN ODI 1

0.19 04H

+26.23 06/98 MRPC H/L SI

.VOL 0.25 04H

+25.81 24 89 06/98~ BOBBIN ODI 5

0.35 07C

+31.68 06/98 MRPC C/L SI VOL 0.27 07C

+31.68 24 129 06/98 BOBBIN ODI 10 0.26 O1H

+25 77 06/98 MRPC H/L SI VOL 0.14 01H

+24.72 25.72 06/98 BOBBIN ODI 2

0.51 03H

+10.77 06/98 MRPC H/L SI VOL 0.42 03H

+10.43 25 86'06/98 BOBBIN ODI 1

0.22 03H

+25.15 06/98 MRPC H/L SI VOL

.0.35 03H

+25.03 25 126 06/98 BOBBIN ODI 1

0.08 04C

+16.37 06/98-MRPC C/L SI VOL 0.22 04C

+16.07 26 57 06/98 BOBBIN ODI 1

0.49 04C

+4.25 06/98 MRPC C/L SI VOL 0.23 04C

+4.53 06/98 MRPC C/L SI VOL 0.40 04C

+2.97 27 56 06/98 BOBBIN ODI 2

0.13 05H

+4.53 27 112 06/98 BOBBIN ODI 10 0.08 03H

+31.34 27 136 06/98-BOBBIN ODI 1

0.23 06H

+6.78 06/98 MRPC H/L SI VOL 0.23 06H

+6.48 28 123 06/98 BOBBIN ODI 1

0.30 04H

+14.67 06/98 MRPC H/L SI VOL 0.20 04H

+14.35 29 70 06/98 ' BOBBIN OXP 31.20 TEH

+23.01 to

+24.88 29 84 06/98 BOBBIN ODI 5

0.06 08C

+4.43 30 89 06/98 BOBBIN ODI 12 0.34 O1H

+22.62

E I

A*************

FTI TUBAN II.(Varzion 2.3) 04/05/1999 11:35:22 McGuire N.S. - Unit Ona Raplacemsnt

-S/G A 06/98 RFO BOBBIN,MRPC C/L SI,MRPC H/L SI,MRPC UBEND SI ATTACHMENT #1 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGA ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION 06/98 MRPC H/L SI VOL 0.44 O1H

+22.13 32 101 06/98 BOBBIN ODI 1

0.30 08C

+3.66 06/98 MRPC C/L SI VOL 0.15 08C

+3.66 37 122 06/98 BOBBIN ODI 1

0.51 05C

+18.45 06/98 MRPC C/L SI VOL 0.24 05C

+18.26 41 134 06/98 BOBBIN ODI 13 0.12 02H

+37.28 06/98 MRPC H/L SI VOL 0.17 02H

+37.31 45 118 06/98 BOBBIN NQI 0.06 04H

+5.62 06/98 BOBBIN ODI 4

0.16 04H

+17.43 06/98 MRPC H/L SI VOL 0.25 04H

+5.49 47 52 06/98 BOBBIN NQI 0.04 TSH

+3.60 48 31 06/98 BOBBIN ODI 9

0.22 06H

+27.75 06/98 MRPC H/L SI VOL 0.22 06H

+27.52 48 43 06/98 BOBBIN ODI-1 0.48 02C

+19.46 06/98 MRPC C/L SI VOL 0.98 02C

+19.69 06/98 MRPC C/L SI VOL 1.01 02C

+17.58 48 57 06/98 BOBBIN ODI

. 1 0.33 02C

+17.98 06/98 MRPC C/L SI VOL 0.36 02C

+17.80 55 56 06/98 BOBBIN ODI 1

0.29 08C

+14.67 06/9F MRPC C/L'SI VOL 0.14 08C

+14.67 55 92 06/98 BOBBIN ODI 1

0.11 06H

+25.57 06/98 MRPC H/L SI VOL 0.31 06H

+25.84 56 59 06/98 BOBBIN ODI 1

0.25 02C

+26.61

)

06/98 MRPC C/L SI VOL 0.21 02C

+26.97.

59 16 06/98 BOBBIN ADI 0.14 04C

+20.16

-06/98 MRPC C/L SI VOL 0.17 04C

+19.80 65 54 06/98 BOBBIN ODI 12 0.10 03H

+5.52

.06/98 MRPC H/L SI VOL 0.24 03H

+5.39

~. 66' 17 06/98 BOBBIN ODI 5

0.13 05H

+31.29 68 69 06/98 BOBBIN ODI 1

0.42 02H

+9.65 06/98 MRPC H/L SI VOL 0.32 02H

+9.22 69~ 58 06/98 BOBBIN ODI 9

0.10 02H

+3.53 06/98 MRPC H/L SI VOL 0.19 02H

+3.33 72 53 06/98 BOBBIN ODI' 4

0.15 03C

+5.29 73' 88 06/98 BOBBIN ODI 1

0.52 02C

+20.04 06/98 MRPC C/L SI VOL 0.48 02C

+19.92 73 90 06/98 BOBBIN ODI 11 0.33 03H

+8.97 06/98 MRPC H/L SI VOL 0.21 03H

+8.71 75 72 06/98 BOBBIN ODI 16 0.07 TSC

+1.23 79: -72 06/98 BOBBIN ODI 1

0.31 03H

+16.31 93 42 06/98 BOBBIN ODI 3

0.34 04H

+16.52 94 77 06/98 ' BOBBIN WAR 4

0.06 FB4

-+0.00 06/98 MRPC H/L SI VOL 0.30 FB4

+0.68 06/98 MRPC UBEND SI VOL 0.30 FB4

+0.68 i

96 71 06/98 BOBBIN ODI 9

0.18 03C'

+13.11 97 102 06/98 BOBBIN IRR 19.73 TEH

+13.14 107 60 06/98 BOBBIN ODI 1

0.28 03C

+16.37 107 94 06/98 BOBBIN ODI 8

0.27 01C

+19.78 06/98 MRPC C/L SI:

VOL 0.13 01C

+19.67

. Total Indications Found = 114 Total Tubes Found = 58 1

F.

FTI TUBAN II (Varsion 2.3) 04/05/1999 11:38:12 McGuire N.S.

- Unit One Rtpl=ctm2nt L

S/G B

. 06/98 RFO l

BOBBIN,MRPC C/L SI,MRPC H/L SI,MRPC UBEND SI Page 1 t

ND P FEC B

ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION 1 40 06/98-BOBBIN NEX 8.52 TSC

-0.27 1 134 06/98 BOBBIN ADI 0.21 03H

+30.43 06/98 MRPC H/L SI VOL 0.45 03H

+30.07 2 25 06/98 BOBBIN ODI 1

0.11 O1H

+4.16 06/98 MRPC H/L SI VOL 0.11 O1H

+4.07 2 55 06/98 BOBBIN ODI 1

0.19 02C

+20.55 3 64 06/98 BOBBIN ODI 1

0.40 07H

+10.87 06/98 MRPC H/L SI VOL 0.24 07H

+10.68 3-88 06/98 BOBBIN ODI 1

0.13 08C

+18.44 06/98 MRPC C/L SI VOL 0.23 OSC

+18.55 l

3 114 06/98 BOBBIN ODI 1

0.39 01H

+14.06 06/98 MRPC H/L SI VOL 0.46 O1H

+13.75 3 124 06/98 BOBBIN ODI 1

0.48 04C

+16.94 06/98 MRPC C/L SI VOL 0.34 04C

+16.88 06/98 MRPC C/L SI VOL 0.43 04C

+16.66 3 142 06/98 BOBBIN NEX 8.61 TSH

-0.31 4

5 06/98 BOBBIN NEX 7.96 TSH

-0.27 to

+0.00 5 22 06/98 BOBBIN ADI 0.27 04C

+18.00 06/98 MRPC C/L SI VOL 0.09 04C

+17.62 6 111 06/98 BOBBIN ODI 7

0.56 09C

+5.86 06/98 MRPC C/L SI VOL 0.41 09C

+5.64 7

4 06/98 BOBBIN NEX 6.86 TSC

-0.28 7

6 06/98 BOBBIN NEX 7.92 TSH

-0.26 8

5 06/98 BOBBIN NEX 6.99 TSH

-0.30 9

6 06/98 BOBBIN NEX 7.20 TSH

-0.26 9 14 06/98 BOBBIN ODI 5

0.45 03C

+14.60 06/98 BOBBIN ODI 17 0.16 03C

+2.62

'06/98 MRPC C/L SI VOL 0.29 03C

+2.53 06/98 MRPC C/L SI VOL 0.34 03C

+14.03 9 126 06/98 BOBBIN ODI 1

0.25 01C

+19.63 10 5 06/98 BOBBIN NEX 7.74 TSH

-0.28 12 51 06/98 BOBBIN ODI 5

0.52 03H

+11.67 06/98 MRPC H/L SI VOL 0.41 03H

+11.48 15 108 06/98 BOBBIN ODI 7

0.30 03C

+18.44 15 114 06/98 BOBBIN OXP 25.67 TEC

+6.91 17 84 06/98 BOBBIN OXP 29.24 TEC

+4.37 17 116 06/98' BOBBIN ODI 10 0.22 03C

+29.53 06/98 BOBBIN ODI 11 0.12 06H

+9.23 06/98 MRPC C/L SI VOL 0.24 03C

+29.16 06/98 MRPC H/L SI VOL 0.43 06H

+9.26 19 6 06/98 BOBBIN NEX 5.08 TSH

-0.26 19 84 06/98 BOBBIN ODI 1

0.20 05C

+15.11 06/98 MRPC C/L SI VOL 0.11 05C

+14.57 20 5 06/98 BOBBIN NEX 6.81 TSH

-0.29 21 54 06/98 BOBBIN ODI 5

0.23 04H

+28.77 21 56 06/98 BOBBIN NOI 0.35 FB6

+1.22 23.

6 06/98 BOBBIN NEX 7.88 TSH

-0.17 23 140 06/98 BOBBIN NEX 6.93 TSH

-0.26 06/9E BOBBIN OXP 27.90 TEC

+11.68 24 63 06/98 BOBBIN OXP 37.95 TEC

+12.95 24.71 06/98 BOBBIN OXP 38.43 TEC

+12.68 25 6 06/98 BOBBIN NEX 7.29 TSH

-0.28 27 6 06/98 BOBBIN NEX 7.85 TSH

-0.31 27 0 06/98 BOBBIN ODI 12 0.09 01C

+22.58 27 12 06/98 BOBBIN ODI 11 0.12 02H

+23.89 27.26 06/98 BOBBIN ODI 1

0.30 02C

+26.89 28 47 06/98 BOBBIN ODI 1

0.37 Olc

+25.23 06/98 MRPC C/L'SI VOL 0.38 01C

+24.96 28 63 06/98 BOBBIN ODI 1

0.47 07C

+27.08 06/98 MRPC C/L SI VOL 0.10 07C

+26.90

[

29 113 06/98 BOBBIN OXP 25.22 TEC

+18.51 29 6 06/98 BOBBIN NEX 6.85 TSH

-0.26 29 48 06/98 BOBBIN OXP 43.69 TEC

+9.42 29 64 06/98 ' BOBBIN OXP 28.12 TEC

+23.88 29 132 06/98 BOBBIN ODI 1

0.36 TSH

+6.63 i

)

PL j

'b************'

FTI TUBAN II (Varsion 2.3) 04/05/1999 11:38:12 McGuire N.S. - Unit Ons Replectment S/G B 06/98 RFO BOBBIN,MRPC C/L SI,MRPC H/L SI,MRPC UBEND SI j

i Page 2 ATTACHMENT #2 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGB ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION 06/98 MRPC H/L SI VOL 0.28 TSH

+6.62 31 6 06/98 BOBBIN NEX 6.24 TSH

-0.26 31 88 06/98 BOBBIN ODI 1

0.38 07H

+6.87 32 5 06/98-BOBBIN NEX 6.57 TSH

-0.17 37 6 06/98 BOBBIN NEX 8.04 TSH-

-0.31 37 120 06/98 BOBBIN ODI 1

0.52 TSH

+13.88 38 61 06/98 BOBBIN ODI 3

0.20 TSH

+17.02 06/98 MRPC H/L SI VOL 0.25 TSH

+17.38 39 102 06/98 BOBBIN ODI 1

0.22 02C

+5.49 06/98 BOBBIN ODI 7

0.09 02H

+5.14 39 130 06/98 BOBBIN-OXP 29.28 TEC

+6.06 41 6 06/98 BOBBIN NEX 8.39 TSH

-0.26 l

06/98 BOBBIN NEX 8.45 TSH

-0.32 42 75 06/98 BOBBIN ODI 13 0.23 01C

+5.89 06/98 MRPC C/L SI VOL 0.07 01C

+4.55 06/98 MRPC C/L SI VOL 0.11 01C

+29.78 i

06/98 MRPC C/L SI VOL 0.16 01C

+5.83 42 91 06/98 BOBBIN ODI 7

0.32 03C

+17.49 43 40 06/98 BOBBIN ODI 8

0.38 08C

+10.78 06/98 MRPC C/L SI VOL 0.38 08C

+10.59 43 62 06/98 BOBBIN OXP 36.09 TEC

+19.18 43 70 06/98 BOBBIN OXP 25.88 TEC

+19.76 44 7 06/98 BOBBIN ODI 23 0.06 06C

+10.63 46 35 06/98 BOBBIN ODI 1

0.30 02C

+14.16 48 41 06/98 BOBBIN OXP 32.39 TSC

-2.19 49 42.06/98 BOBBIN ODI 1

0.19 02C

+26.04 06/98 MRPC C/L SI VOL 0.31 02C

+25.71 51 34 06/98 BOBBIN ODI 5

0.11 O1H

+16.02 51 48 06/98 BOBBIN OXP 38.27 TEC

+0.00 to

+4.43 51 64 06/98 BOBBIN OXP 66.58 TEC

+4.24

51. 72 06/98 BOBBIN OXP 30.51 TEC

+0.00 to

+5.11 53 90 06/98 BOBBIN ODI 1

0.72 02C

+28.77 06/98 MRPC C/L SI VOL 0.40 02C

+28.44 54 61 06/98 BOBBIN ODI 1

0.13 TSH

+19.07 54 93 06/98 BOBBIN ODI 7

0.33 02H

+23.76 06/98 MRPC H/L SI VOL 0.43 02H

+23.64 56 75 06/98 BOBBIN ODI 1

0.35 03H

+10.49 06/98 MRPC H/L SI VOL 0.62 03H

+10.41 58 51 06/98 BOBBIN ODI 4

0.12 TSC

+14.21 58 85 06/98 BOBBIN ODI 2

0.36 06C

+18.12 06/98 MRPC C/L SI VOL 0.29 06C

+18.26 58 91 06/98 BOBBIN ODI 7

0.56 02H

+11.68 06/98 MRPC H/L SI VOL 0.81 02H

+11.87 59 46 06/98 BOBBIN ODI 17 0.10 03C

+12.69 59 128 06/98 BOBBIN NEX 6.03 TSH

-0.25 60 85 06/98 BOBBIN ODI 4

0.09 04H

+30.38 06/98 MRPC H/L SI VOL 0.18 04H

+30.14 60 109 06/98 BOBBIN ADI 0.09 04C

+38.06 61 104 06/98 BOBBIN ODI 1

0.22 06H

+34.41 06/98 MRPC H/L SI' VOL 0.69 06H

+34.28 62 85 06/98 BOBBIN ADI 0.18 04C

+36.63 06/98_ MRPC C/L SI VOL 0.33 04C

+36.24 63 84 06/98 BOBBIN ODI 1

0.30 02C

+6.51 06/98 MRPC C/L SI VOL 0.32 02C

+6.45 64 129 06/98 BOBBIN NEX 6.29 TSH

-0.25 66 103 06/98 BOBBIN ODI 1

0.25 06H

+3.47 06/98 MRPC H/L SI VOL 0.19 06H

+3.19 67 106 06/98 BOBBIN OXP 51.37 TEC

+11.80 67 122 06/98 BOBBIN OXP 35.22 TEC

+12.79 67 130 06/98 BOBBIN OXP 65.85 TEC

+12.21 68 35 06/98 BOBBIN OXP 49.95 TEC

+1.46 to

+19.65 68 55 06/98 BOBBIN NEX 6.64 TSH

-0.26 06/98 BOBBIN ODI 3

0.17 06C

+29.84 06/98 MRPC C/L SI VOL' O.24 06C

+29.82 68 59 06/98 BOBBIN OXP 26.01 TEC

+19.23

FTI TUBAN II (Varsion 2.3) 04'/05/1959 11:38:12 McGuire N.S. - Unit One Rzplaccmant S/G B 06/98 RFO BOBBIN,MRPC C/L SI,MRPC H/L SI,MRPC UBEND SI ATTACHMENT #2 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGB ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION 70 71 06/98 BOBBIN ODI 1

0.19 07H

+8.71 71 56 06/98 BOBBIN ODI 1

0.59 FB8

+4.89 06/98 MRPC UBEND SI VOL 0.29 FBB

+5.22 71 60 06/98 BOBBIN ODI 1

0.35 03C

+29.60 06/98 BOBBIN ODI 1

0.52 03C

+32.19 06/98 MRPC C/L SI VOL 0.24 03C

+31.83 71 74 06/98 BOBBIN OXP 38.05 TEC

+2.86 71 82 06/98 BOBBIN ODI 1

0.23 06C

+8.76 06/98 BOBBIN ODI 3

0.18 09H

-8.80 06/98 BOBBIN ODI 6

0.18 OBH

+32.44 06/98 MRPC C/L SI VOL 0.16 06C

+8.68 06/98 MRPC H/L SI' VOL 0.26 08H

+32.10 72 55 06/98 BOBBIN NQI 0.50 FB4

-1.23 06/98 MRPC UBEND SI VOL 0.46 FB4

-1.33 06/98 MRPC UBEND SI VOL 1.50 FB4

-1.30 73 52 06/98 BOBBIN ODI 1

0.31 02C

+30.04 73 112 06/98 BOBBIN OXP 25.30 TEC

+11.35 73 120 06/98 BOBBIN OXP 33.42 TEC

+11.46

-73 128 06/98 BOBBIN OXP 29.08 TEC

+11.49 74 111 06/98 BOBBIN ADI 0.44 TSC

+15.26 75 98 06/98 BOBBIN ODI 1

0.12 01H

+9.96 06/98 MRPC H/L SI VOL 0.36 O1H

+9.88 75 100 06/98 BOBBIN OXP 33.34 TEC

+11.76 75 124 06/98 BOBBIN OXP 38.80 TEC

+12.80 76.49 06/98 BOBBIN ODI 1

0.20 TSH

+3.39 06/98 MRPC H/L SI VOL 0.18 TSH

+3.20 76 69 06/98 BOBBIN ODI 1

0.22 04H

+20.36 78 31 06/98 BOBBIN OXP 46.57 TEC

+9.92 to

+11.28 78 55 06/98 BOBBIN OXP 4f.90 TEC

+10.52 79 24 06/98 BOBBIN ADI

'J.13 03H

+14.26 79 82 06/98 BOBBIN NQI 0.07 04C

+10.86 06/98 BOBBIN ODI 1

0.12 04C

+13.55 06/98 BOBBIN.

ODI 8

9.08 04C

+26.56 06/98 MRPC C/L SI VOL 0.16 04C

+13.18 06/98 MRPC C/L SI VOL 0.23 04C

+10.55 06/98 MRPC C/L SI VOL 0.26 04C

+26.19 79 86 06/98 BOBBIN ODI 2

0.42 02C

+35.30 06/98 MRPC C/L SI VOL 0.62 02C 435.30 81 32 06/98 BOBBIN ODI 1

0.44 08C

+30.60 06/98 MRPC C/L SI VOL 0.10 08C

+30.22 81 104'06/98 BOBBIN ODI 13 0.18 02C

+8.77 84 27 06/98 BOBBIN OXP 44.84 TEC

+11.78 84 35 06/98 BOBBIN OXP 40.23 TEC

+11.94 85 52 06/98 BOBBIN ODI 1

0.24 04H

+29.32 06/98 MRPC H/L SI VOL 0.14 04H

+29.48 86 91 06/98 BOBBIN OXP 47.71 TEC

+0.00 to

+9.43 86 115 06/98 BOBBIN OXP 53.97 TEC

+9.61 87 26 06/98 BOBBIN OXP 28.21 TEC

+7.40 88 29 06/98 BOBBIN OXP 38.40 TEC

+8.46 88 53 06/98 BOBBIN.

ODI 4

0.19 O1H

+10.26 06/98 BOBBIN OXP 41.11 TEC

+4.75 to

+8.24 98 101 06/98. BOBBIN ODI 2

0.68 02H

+9.13 06/98 MRPC H/L SI VOL 0.35 02H

+8.73 90 115 06/98 BOBBIN ODI-1 0.24 03C

+29.01 06/98 MRPC C/L SI VOL 0.39 03C

+29.01 92 91 06/98 BOBBIN ODI 4

0.28 02H

+24.13 06/98 MRPC H/L SI VOL 0.38 02H

+23.67 92 99 06/98-BOBBIN OXP 33.91 TEC

+24.51 95 102 06/98 BOBBIN ADI 0.13 O1H

+27.85 96 37 06/98 BOBBIN-ODI 1

0.23 OBC

+24.52 97 66 06/98 BOBBIN OXP 44.40 TEC

+13.74 99 36 06/98 BOBBIN ODI 1

0.27 02C

+13.74 101 66 06/98 BOBBIN ODI 1

0.24 02C

+33.31 06/98 MRPC C/L SI VOL 0.23 02C

+32.79 101 86 06/98 BOBBIN' OXP 31.26 TEC

+1.93 to

+21.82

p A*************'

FTI TUBAN II (Varcion 2.3) 04/05/1999 11:38:12 McGuira N.S. - Unit One Replacem2nt S/G B 06/98 RFO BOBBIN,MRPC C/L SI,MRPC H/L'SI,MRPC UBEND SI Page 4 ATTACHMENT #2 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS -'SGB ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION 102 35 06/98 BOBBIN ODI 1

0.17 O1H

+14.79 06/98 BOBBIN ODI 1

0.23 02H

+26.41 103 48 06/98. BOBBIN OXP 60.13 TEC'

+10.24 103 56 06/98 BOBBIN OXP 28.81 TEC

+9.41

.103 64 06/98 BOBBIN OXP 58.41 TEC

+10.10 103 72 06/98' BOBBIN OXP 47.21 TEC

+9.76 104 45 06/98 BOBBIN NEX 9.17 TSC

-0.26 104 79 06/98 BOBBIN OXP 32.83 TEC

+13.74

-104 87 06/98 BOBBIN-OXP 27.19 TEC

+13.57 105 46 05/98 BOBBIN OXP 26.86 TEC

+4.20 106 49 06/98 BOBBIN OXP 45.91 TEC

+0.22 to

+7.52 t

'106 57 06/98 BOBBIN OXP 68.60 TEC

+0.48 to

+2.64 106 65 06/98 BOBBIN OXP 34.45 TEC

+8.G8 106 73 06/98 BOBBIN OXP 33.90 TEC

+5.84 to

+8.45

,106 89 06/98 BOBBIN OXP 34.99 TSC

-1.66 107 60 06/98 BOBBIN OXP 27.04 TEC

+0.46 107 80 06/98 BOBBIN OXP 30.11 TEC

+5.78 108 45 06/98 BOBBIN NEX 8.21 TSC

-0.30 to

+0 00 06/98 BOBBIN OXP 34.76 TEC

+0.39 to

+7.77 108 69 06/98-BOBBIN OXP 26.65 TEC

+7.09 108 77 06/98 BOBBIN OXP 28.91 TEC

+8.27 108 97 06/98. BOBBIN OXP 26,44 TEC

+12.54 112 57 06/98 BOBBIN NEX 5.53 TSH

-0.25 113 78 06/98 BOBBIN OXP 50.42 TEC

+8.04 to

+13.08 114 53 06/98 BOBBIN NEX 8.24 TSH

-0.25 114-55 06/98 BOBBIN NEX 5.23 TSH

-0.25 114 73 06/98 BOBBIN OXP 49.54 TEC

+5.55 to

+8.33 114 79 06/98' BOBBIN OXP 24.20 TEC

+4.43 to

+17.58 114 81 06/98 BOBBIN OXP 47.11 TEC

+4.45 to

+11.39 114 83.06/98 BOBBIN OXP 30.92 TEC

+0.81 114 87 06/98 BOBBIN IRR 29.30 TEC

+17.18 to

+23.05 114 89 06/98 BOBBIN OXP 33.43 TEC

+2.51 to

+11.65 114 91 06 98 BOBBIN OXP 38.03 TEC

+0.71 to

+8.60 115 56 06 98 BOBBIN NEX 4.84 TSH

-0.25 116 55 06 98 BOBBIN NEX 6.42 TSH

-0.25 117 58 06/98 BOBBIN' NEX 7.22 TSH

-0.28 117 70 06/98 BOBBIN OXP 39.00 TSC

-2.11 06/98 BOBBIN OXP 32.75 TEC

+2.10 to

+14.90 117 86 06/98 BOBBIN OXP 31.65 TEC

+4.74 to

+13.33 Total Indications Found = 234 Total Tubes Found - 166 1

rT~

d*****k******

'FTI TUBAN II (Varsion 2.3) 04/05/1999 11:39:29 McGuira N.S. - Unit Ona P.2 placement

e************

S/G C 06/98 F.FO BOBBIN,MRPC C/L SI,MRPC H/L SI,MRPC UBEND SI l-Page 1 ATTACHMENT #3 - INDICATIONS OF IMPERFECTIONS

.INDS OF IMPERFECTIONS - SGC-ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION 2 139 06/98-BOBBIN ODI 1

0.56 O1H

+7.76 06/98 MRPC H/L SI VOL 0.16 O1H

+7.23 3 46 06/98 BOBBIN ODI 1

0.23 08C

+11.34 06/98 BOBBIN-ODI 1

0.33 02C

+21.60 06/99.MRPC C/L SI VOL 0.20 OBC

+11.31 06/98 MRPC C/L SI VOL 0.41 02C

+21.75 4 51 06/98 BOBBIN OXP 52.87 TEC

+12.26 4 59 06/98 BOBBIN OXP 75.36 TEC

+12.32 4 -67 06/98-BOBBIN OXP 51.55 TEC

+12.01 to

+13.15 5-80 06/98 BOBBIN ODI 1

0.43 02C

+34.38 06/98 MRPC C/L SI VOL 0.42 02C

+34.17 6 77 06/98 BOBBIN ODI 1

0.30 Olc

+17.55 06/98 MRPC C/L SI VOL 0 41 01C

-+17.27 6 129 06/98 BOBBIN ODI 1

0.36 02H

+31.90 7 80 06/98 BOBBIN ODI 2

0.24 02C

+16.93 06/98 MRPC C/L SI VOL 0.09 02C

+16.58 12 45 06/98 BOBBIN ODI 1

0.44 03H

+15.10 06/98 MRPC H/L SI VOL 0.25 03H

+14.48 12 49 06/98 BOBBIN ODI 9

0.11 04C

+15.03 06/98 BOBBIN ODI 14 0.07 08C

+5.80 06/98 MRPC C/L SI VOL 0.14 08C

+5.67 06/98 MRPC C/L SI VOL 0.57 04C

+15.14 12 105 06/98 BOBBIN ADI 0.17 P'

+17.21 13 54 06/98 BOBBIN ODI 9

0.26 g.'

+7.10 06/98' MRPC C/L SI

/OL 1.09 '

+7.27 13 122 06/98 BOBBIN ADI 0.18 f ~C

+7.63 06/98 BOBBIN ADI 0.25 OSH

+26.27 06/98 MRPC C/L SI VOL 0.17 04C

+7.35

-U6 98 MRPC H/L SI VOL 0.11 05H

+25.74 06 98 MRPC H/L SI VOL 0.37 05H

+24.13 14 43 06 98 BOBBIN ADI 0.17 04C

+3.06 06/98 MRPC C/L SI VOL 0.19 04C

+2.96 16 37 06/98 BOBBIN ODI 1

0.88 01C

+22.93 to

+31.08 17 96 06/98 BOBBIN ODI 17- 0.13 03C

+28.57 06/98 MRPC C/L SI VOL 0.22 03C

+28.75 18 9 06/98 BOBBIN OXP 28,91 TEC

+16.08 06/98 BOBBIN ODI 7

0.21 05C

+19.54 06/98 MRPC C/L SI VOL 0.18 05C

+19.20 18 17 06/98 BOBBIN OXP 40.14 TEC

+15.41 18 19 06/98 BOBBIN' ODI 1

0.16 01C

+19.50 18 25 06/98 BOBBIN OXP 31.39 TEC

+14.59 to

+16.22 19 12 06/98 BOBBIN ODI B

0.32 06H

+13.74 06/98 MRPC H/L SI VOL 0.19 06H

+14.85 06/98 MRPC H/L SI VOL 0.26 06H

+13.74 19 78 06/98 BOBBIN OXP 35.18 TEH

+0.41 to

+1.80 19 86 06/98 BOBBIN OXP 34.13 TEH

+0.50 to

+2.76 21 10 06/98 BOBBIN ODI 12 0.28 03H

+13.34 06/98 MRPC H/L SI VOL 0.29 03H

+13.40 21 42 06/98 BOBBIN NOI 0.65 CBH

+7.19 22 121 06 98 BOBBIN ODI 1

0.71 03H

+14.78 06 98 MRPC H/L SI VOL 0.96 03H

+14.82 23 78 06 98 BOBBIN ODI 1

0.30 03C

+16.23 06 98 BOBBIN ODI 14 0.12 Olc

+12.48 06 58 MRPC C/L SI VOL 0.23 03C

+15.45 06 98 MRPC C/L SI VOL 0.51 01C

+12.34 23 118 06 98~ BOBBIN ODI 1

0.30 02H

+17.58 06 98 MRPC H/L SI VOL 0.25 02H

+17.59 25 12 06/98 BOBBIN ODI 1

0.53 07H

+16.67 06/98 MRPC H/L SI VOL 0.51 07H

+16.74 25 66 06/98 BOBBIN ODI 1

0.36 06C

+32.92 06/98 MRPC C/L SI VOL 0.17 06C

+32.73

[

26 9 06/98 BOBBIN ODI 1

0.34 04C

+37.83 l

06/98 MRPC C/L SI VOL 0.49 04C

+37.84 1

27 32 06/98 BOBBIN ODI 7

0.34 03C

+29.65 06/98 MRPC C/L SI VOL 0.34 03C

+25.66 L

[

1 E************

FTI TUBAN II (Varzion 2.3) 04/05/1999 11:3S:29 McGuire N.S.

- Unit Ona Rtplactm:nt S/G C l

06/98 RFO BOBBIN,MRPC C/L SI,MRPC H/L SI,MRPC UBEND SI Page 2 ATTACHMENT #3 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGC

-ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION 06/98 MRPC C/L SI VOL 0.35 03C

+29.48 29 20 06/98 BOBBIN ODI 1

0.27 06C

+22.15 06/98 MRPC C/L SI VOL 0.49 06C

+24.06 29 102 06/98 BOBBIN ODI 1

0.29 02H

+20.35 06/98 MRPC H/L SI VOL 0.51 02H

+20.62 30 69 06/98 BOBBIN ODI 1

0.20 03H

+7.34 06/98 BOBBIN ODI 1

0.21 07H

+2.91 06/98 BOBBIN ODI 1

0.68 01C

+13.07 06/98 MRPC C/L SI VOL 0.39 01C

+14.04 06/98 MRPC H/L SI VOL 0.31 03H

+7.02 06/98 MRPC H/L SI VOL 0.32 07H

+2.65 31 12 06/98 BOBBIN ADI 0.17 02C

+14.99 06/98 MRPC C/L SI VOL 0.21 02C

+15.26 31 98 06/98 BOBBIN ADI 0.11 07C

+30.14 34 67 06/98 BOBBIN OXP 25.07 TEH

+21.36 34 93 06/98 BOBBIN ODI 1

0.67 04C

+26.89 06/98 MRPC C/L SI VOL 0.69 04C

+26.52 35 126 06/98 BOBBIN ODI 7

0.17 05H

+6.95 06/98 MRPC H/L SI VOL 0.21 05H

+6.70 36 27 06/98 BOBBIN ODI 10 0.18 02C

+15.23 06/98 MRPC C/L SI VOL 0.26 02C

+15.08 37 6 06/98 BOBBIN ODI 1

0.21 05H

+16.50 06/98 MRPC H/L SI VOL 0.54 05H

+17.08 37 44 06/98 BOBBIN ODI 4

0.11 03C

+16.18 06/98 MRPC C/L SI VOL 0.52 03C

+16.34 38 137 06/98 BOBBIN OXP 29.18 TEC

+8.05 39 64 06/98 BOBBIN ODI 1

0.23 02C

+28.09 06/98 MRPC C/L SI VOL 0.45 02C

+27.95 39 68 06/98 BOBBIN ODI 1

0.20 02C

+15.57 39 82 06/98 BOBBIN ODI 1

0.61 06C

+8.17 06/98 MRPC C/L SI VOL 0.32 06C

+8.06 39 104 06/98 BOBBIN ODI 18 0.40 06C

+5.63 40 49 06/98 BOBBIN ODI 1

0.22 04C

+22.77 41 10 06/98 BOBBIN ODI 1

0.23 02C

+10.17 06/98 MRPC C/L SI VOL 0.16 02C

+9.97 41 14 06/98 BOBBIN ODI 2

0.19 02C

+28.25 06/98 MRPC C/L SI VOL 0.44 02C

+28.60 45 106 06/98 BOBBIN ODI 7

0.70 02C

+6.12 45 132 06/98 BOBBIN ODI 16 0.13 04C

+12.47 06/98 BOBBIN ODI 16 0.25 02C

+15.17 06/98 MRPC C/L SI VOL 0.15 02C

+14.91 46 37 06/98 BOBBIN ODI 1

0.30 06C

+19.00 06/98 BOBBIN ODI 1

0.40 06C

+19.96 06/98 MRPC C/L SI VOL 0.19 06C

+19.19 06/98 MRPC C/L SI VOL 0.36 06C

+19.89 47 24 06/98 BOBBIN ODI 1

0.61 02H

+22.10 06/98 MRPC H/L SI VOL 0.30 02H

+22.70 49 104 06/98 BOBBIN ADI 0.20 03C

+17.11 06/98 MRPC C/L SI VOL 0.20 03C

+17.28 51 20 06/98 BOBBIN ODI 1

0.35 04C

+21.80 06/98 BOBBIN ODI 5

0.29 04C

+22.32 06/98 BOBBIN ODI 12 0.21 04C

+19.47 06/98 MRPC C/L SI VOL 0.25 04C

+22.52 D4/98 MRPC C/L SI VOL 0.36 04C

+19.56 06/98 MRPC C/L SI VOL 0.68 04C

+21.74 51 66 GG/98 BOBBIN ODI 7

0.25 02C

+12.02 06/98 MRPC C/L SI VOL 0.44 02C

+11.57 51 68 06/98 BOBBIN NOI 0.21 FB6

+1.55 06/98 MRPC UBEND SI VOL 0.23 FB6

+2.13 51 74 06/98 BOBBIN ODI 12 0.24 04C

+19.74 06/98 MRPC C/L SI VOL 0.25 04C

+19.60 51 90 06/98 BOBBIN ADI 0.11 06C

+12.93 06/98 MRPC C/L SI VOL 0.28 06C

+15.51 I

51 96 06/98 BOBBIN ODI 1

0.47 04C

+19.60 i

06/98 MRPC C/L FT VOL 0.44 04C

+19.27 i

)

F

[-

l' 4****V*******'

'FTI TURAN II (Varsion 2.3) 04/05/1999 11:39:29 r*************

McGuire N.S.

- Unit Ons Rsplacam:nt S/G C-06/98 RFO-i "*************

BOBBIN,MRPC C/L SI,MRPC H/L SI,MRPC UBEND SI ATTACHMENT #3' - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGC ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION 52 75 06/98 BOBBIN ADI 0.24 06C

+23.46 06/98 BOBBIN ODI 1

0.21 06C

+22.53 06/98 MRPC C/L SI VOL 0.34 06C

+23.04 06/98 MRPC C/L SI VOL 0.37 06C

+22.11 54 13 06/98 BOBBIN ODI 1

0.10 03C

+21.64' 06/98 MRPC C/L-SI VOLL 0.22 03C

+21.78 54 35 06/98 BOBBIN ODI 1

0.04 TSC

+4.76 55 10 06/98 BOBBIN ADI 0.21 04C

+19.21 E

06/98 MRPC C/L~SI VOL 0.14 04C

+19.74 55' 20 06/98 - BOBBIN ODI 1

0.18 06C

+17.20 60 115 06/98 POBBIN ODI 9

0.12 01C

+10.13 60 123 06/98 BOBBIN ODI 7

0.38 05C

+28.40 06/98 MRPC C/L SI VOL 0.23 05C

+28.13 61 68 06/98 BOBBIN NQI 0.15 FB5

+0.72 62-77 06/98 BOBBIN ODI 14 0.25 01C

+9.86' 06/98 MRPC C/L SI VOL 0.16 01C

+9.21 63 44 06/98 BOBBIN ODI 6

0.18 07H

+25.19 l

06 98 MRPC H/L SI VOL 0.43 07H

+25.31 15 3 62.06 98 BOBBIN OXP 78.78 TEC

+1.03 to

+3.51 l

63 70 06/98 BOBBIN GXP 73.93 TEC

+1.36 to

+2.37 I-63

.78 06/98 BOBBIN OXP

            • TEC

+1.22 to

+2.83 l

'8' 63 82 06/98 BOBBIN ADI 0.12 03C

+29.09 06/98 BOBBIN ADI 0.14 02C

+3.85 06/98 MRPC C/L SI VOL 0.15 02C

+3.64 64 21 06/98 BOBBIN ODI-14 0.74 04C

+32.53 06/98 MRPC C/L SI VOL 0.39 04C

+32.70 64 '25 06 98 BOBBIN ODI 19 0.30 03H

+8.85 06 98 MRPC H/L SI VOL 0.28 03H

+8.70 65 98 06 98 BOBBIN ADI 0.20 03C

+7.26 C6/98 BOBBIN ADI 0.31 03H

+6.09 06 98 BOBBIN ODI 1

0.33 02C

+34.72 06 98 BOBBIN ODI 3'

O.17 07C

+6.96 i

06 98 MRPC C/L SI VOL 0.24 03C

+11.08 I

06/9E MRPC C/L SI VOL 0.29 03C

+7.34

(

06/98 MRPC C/L SI VOL 0.32 07C

+6.89 06/98 MRPC C/L SI VOL 0.46 02C

+34.79 06/98 MRPC H/L SI VOL 0.26 03H

+6.14 66 85 06/98 BOBBIN ADI 0.21 03C

+23.04 66 101 06/98 BOBBIN ADI 0.21 04H

+26.00 67 106 06/98 BOBBIN ODI 7

0.10 07H

' +24.95 06/98 BOBBIN ODI 11 0.87 07H

+25.88 06/98 MRPC H/L SI VOL 0.29 07H

+26.15 06/98 MRPC H/L SI VOL 0.32 07H

+25.49 06/98 MRPC H/L SI VOL 0.66 07H

+26.16 68 99 06/98 BOBBIN ADI 0.19 01C

+26.83 06/98 BOBBIN ODI 1

0.22 01C

+28.67 06/98 MRPC C/L SI VOL 0.16 01C

+25.80 69 88 06/98 BOBBIN ADI 0.14 02C

+12.64 06/98 MRPC C/L SI VOL 0.35 02C

+12.28

70. 55 06/98 BOBBIN ODI 17 0.14 03C

+5.74 06/98 MRPC C/L SI VOL 0.27 03C

+5.47 70 107 06/98 BOBBIN ODI 8

0.25 05H

+26.64 06/98 MRPC H/L SI VOL 0.35-05H

+26.58 71 72 06/98 BOBBIN ODI 1

0.41 02H

+20.97 06/98 'MRPC H/L SI VOL 0.19 02H

+20.75

73. 18 06/98 BOBBIN ADI C 21 02H

+25.74 73 74 06/98 BOBBIN ADI y.15 03H

+34.37 73 90 06/98 BOBBIN ODI 1

0.26 03C

+33.14 06/98 MRPC C/L SI VOL 0.53 03C

+33.24 73.

98 06/98 BOBBIN ADI 0.17 01C

+19,76 06/98 MRPC C/L SI VOL 0.11 01C

+19.22 74 117 n6/98 BOBBIN ODI 15 0.12 TSC

+2.02 06/98 MRPC C/L SI VOL 0.21 TSC

+2.04 75 48 06/98 BOBBIN ODI 1

0.23 09C

+6.13 6

06/98 BOBBIN ODI 1

0.31 OBH

+34.03

A*************

FTI 1NR3Mi II (Varsion 2.3) 04/05/1999 11:39:29

-McGuire N.S.

- Unit Ona Rapitctm2nt S/G C 06/98 RFO BOBBIN,MRPC C/L SI,MRPC H/L SI,MRPC UBEND SI

'+

Page 4 ATTACHMENT #3 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGC ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION 06/98 MRPC H/L SI VOL 0.44 OBH

+34.06 i

75' 60 06/98 BOBBIN ADI 0.21 02H

+15.31 06/98 MRPC H/L SI-VOL 0.22 02H

+15.26 77 22 06/98 BOBBIN OXP.

25.67 TEH

+12.88 78 35 06/98 BOBBIN ODI 1

0.62 08C

+11.65 06/98 BOBBIN ODI 15 0.13 06C

+5.10 06/98 MRPC C/L SI VOL 0.07 06C

+4.83 06/98 MRPC C/L SI VOL 0.69 OBC

+12.17 79 52 06/98 BOBBIN ODI

.11-0.26 01C

+19.64 06/98 MRPC C/L SI VOL

. 0.25 01C

+19.48 79 68 06/98 BOBBIN ODI 1

0.42 01C

+12.50 06/98 MRPC C/L SI VOL 0.49 01C

+12.43 83 50'06/98 BOBBIN ADI 0.20 05H

+24.16 06/98 MRPC H/L SI VOL 0.10 05H

+24.10 85 28 06/98 BOBBIN ODI 1

0.26 04C

+21.16 48 '6/98 BOBBIN ADI 0.24 03C

+16.58 85 0

06/98 BOBBIN ODI 13 0.23 TSC

+18.17 06/98 MRPC C/L SI VOL 0.08 TSC

+18.07 06/98 MRPC C/L SI VOL 0.38 03C

+15.66 86 55 06/98 BOBBIN ADI 0.24 02H

+27.63 06/98 MRPC H/L SI VOL 0.34 02H

+27.99 88 41 06/98 BOBBIN ODI 1 ~ 0.29 05C

+18,44 92 51 06/98 BOBBIN ODI 1

0.41 04H

+33.77 06/98 MRPC H/L SI VOL 0.38 04H

+33.96 92.117 06/98 BOBBIN ODI 11 0.21 FB4

+6.52 06/98 MRPC UBEND SI VOL 3.46 FB4

+6.70 94 67 06/98 BOBBIN ODI 1

0.22 OSC

+16.94 06/98. MRPC C/L SI VOL 0.48 05C

+16.92 96 81.06/98 BOBBIN OXP 33.94 TEH

+11.67 to

+12.35 96 97 06/98 BOBBIN ADI 0.14 02C

+26.59 97 68 06/98 BOBBIN ODI 1

v.35 08C

+27.69 98 103 06/98 BOBBIN ODI' 1

0.17 03H-

+17.63 99 34 06/98 BOBBIN NEX 6.01 TSC

-0.25 104 67 06/98 BOBBIN ODI-- 15 0.37 03C

+10.38 06/98 MRPC C/L SI VOL 0.33 03C

+9.74 105 40 06/98 BOBBIN ODI 10 0.19 04H

+10.73 105 54 06/98 BOBBIN ODI 10 0.42 04C

+21.90 06/98 MRPC C/L SI VOL 0.25 04C

+21.76 106 43 06/98 BOBBIN ODI' 1

0.23 04C

+24.64 06/98 MRPC C/L SI VOL 0.35 04C

+24.78 110 -71 06/98 BOBBIN ADI 0.29 06C

+23.85 06/98' MRPC C/L SI VOL 0.49 06C

+23.22 l

112 81 06/98-BOBBIN ODI 6

0.40 02C

+34.45

(

06/98 MRPC C/L SI VOL 0.55 02C

+33.97 112 97 06/98 BOBBIN ODI 7

0.23 02C

+34.64 06/98 MRPC C/L SI.

VOL 0.38 02C

+34.89 117 84 06/98 BOBBIN ADI 0.14 06C

+32.30 l

i Total Indications Found = 242 Total Tubes Found = 120 l

1 L

9

I

            • 4******

FTI TUBAN II (Version 2.3) 04/12/1999 13:55:32 f

McGuire N.S. - Unit One Raplaccm:nt ee****e*****e g/g p 06/98 RFO.

BOBBIN,MRPC C/L SI,MRPC H/L SI,MRPC UBEND SI I

Page 1 ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGD ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION 2.

79 06/98 BOBBIN ODI 1

1.05 04H

+7,00 06/98 MRPC H/L SI VOL 0.58 04H

+6.90 5

8 06/98 BOBBIN ODI

_ 1 0.29 O1H

+30.30

.06/98 MRPC H/L SI VOL 0.35 O1H

+30.17 7 140 06/98 BOBBIN OXP 29.59 TSC

-0.82 9 68 06/98 BOBBIN ODI 1

0.47 O1H

+25.66 06/98 MRPC H/L SI VOL

'O.36 O1H

+25.39 11 60 06/98 BOBBIN OXP 32.94 TSC

-0.90 13 46 06/98 BOBBIN ODI 1

0.35 07C

+31.42

.06/98 MRPC C/L SI VOL 0.40 07C

+31.12 14 95 06/98 BOBBIN ODI 1

0.84 04C

+4.85 06/98 MRPC C/L SI VOL 0.51 04C

+4.62 15 142 06/98 BOBBIN ODI 1

0.15 01C

+20.74 06/98 MRPC C/L SI VOL 0.16 01C

+20.49 18 43 06/98. BOBBIN OXP 36.16 TSH

-0.49

'22 53 06/98 BOBBIN ODI 11 0.31 05H

+34.52 06/98 MRPC H/L SI VOL 0.54 05H

+34.35 22 131 06/98 BOBBIN ADI 0.14 07C

+11.69 06/98 BOBBIN ODI 1

0.10 06H

+29.99 06/98 BOBBIN ADI 0.27 04H

+32.05 to

+34.85 23 130 06/98 BOBBIN OXP 27.33 TEH

+2.12 24 55 06/98 BOBBIN ODI 12 0.12 05H

+20.07 06/98 MRPC H/L SI VOL 0.50 05H

+20.08 24 59 06/98 BOBBIN ODI 1

0.18 04C

+20.76 06/98 BOBBIN ODI 1

0.30 O1H

+27.43 06/98 BOBBIN ODI 1

0.33 05H

+29.72 06/98 BOBBIN' ODI 1

0.34 04C

+19.68 06/98 MRPC C/L SI VOL 0.47 04C

+20.64 06/98 MRPC C/L SI VOL 0.67 04C

+19.62 06/98 MRPC H/L SI VOL.

0.45 05H

+29.36 06/98 MRPC H/L SI VOL 0.52 O1H

+27.17 06/98 MRPC H/L SI VOL 0.92 05H

+27.32 24 65 06/98 BOBBIN OXP 26.36 TSH

-0.71 25 60 06/98 BOBBIN ODI 1

0.46 04C

+20.31 06/98 MRPC C/L SI VOL 0.69 04C

+20.11 25 88 06/98 BOBBIN ADI 0.17 02H

+5.39 30 109 06/98 BOBBIN ODI 1

0.69 04H

+11.49 06/98 MRPC H/L SI VOL 0.81 04H

+11.50 31'134 06/98 BOBBIN OXP 30.92 TSH

-0.87 to

+0.00 31 136 06/98 BOBBIN OXP 32.78 TSH

-0.58 32 129 06/98~ BOBBIN OXP 27.44 TSC

-0.80 to

-0.14 34 71 06/98 BOBBIN ODI 8

0.34 02H

+31.53 06/98 MRPC H/L SI VOL 0.86 02H

+31.72 34 135 06/98 BOBBIN OXP 35.88 TSH

-1.56 to

-0.55 35 138 06/98 BOBBIN OXP 13.36 TSC

-1.30 38 ~21 06/98 BOBBIN OXP 38.26 TSH

-1.35 to

-0.21 38 -71 06/98 BOBBIN ADI 0.12 04C

+10.69 06/98 BOBBIN ODI 1

0.13 04C

+14.93 40 125 06/98 BOBBIN ODI 1

0.23 02H

+28.09 06/98 MRPC H/L SI VOL 0.47 02H

+28.09 42 71 06/98 BOBBIN ODI 1

0.30 01C

+25.27 06/98 BOBBIN ODI 8

0.23 03H

+20.78 06/98. MRPC C/L SI VOL

0. 55 01 C

+25.33 06/98 MRPC H/L SI VOL 0.61 03H

+20.97 44 '

7 06/98 EOBBIN ODI 1

0.52 04H

+15.20 06/98 MRPC H/L SI VOL 0.53 04H

+14.92 45 66 06/98 BOBBIN ODI 3

0.18 03H

+9.59 06/98 MRPC H/L SI VOL 0.56 03H

+9 73 46 127 06/98 BOBBIN ODI 1

0.47 08H

+10.87 06/98 MRPC H/L SI VOL 0.29 OBH

+10.38

47 42 06/98 BOBBIN ODI 1

0.22 0311

+25.22 47 66 06/98 BOBBIN ODI 5

0.60 04C

+10.63 47 80 06/98 BOBBIN ODI 1

0.41 02H

+29.33 48 23 06/98 BOBBIN ODI 1

0.70 06C

+26.78 06/98 MRPC C/L S1 VOL 0.24 06c

+26.22 i

FTI TUBAN II (Version 2.3) 04/12/1999 13:55:32 McGuire N.S.

- Unit One Rapleesm:nt S/G D 06/98 RFO BOBBIN,MRPC C/L SI,MRPC H/L SI,MRPC UBEND SI Page 2 ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGD ROW COL OUTAGE TEST TYPE IND %TW VOLTS LOCATION 51 14 06/98 BOBBIN OXP 25.05 TSC

-1.15 to

-0.04 52 69 06/98 BOBBIN ODI 1

0.48 03C

+3.85 06/98 MRPC C/L SI VOL 0.29 03C

+3.13 53 32 06/98 BOBBIN ODI 1

0.27 06H

+19.95 53 04 06/98 BOBBIN ADI 0.15 02H

+20.89 06/98 BOBBIN ODI 14 0.18 02H

+18.90 54 47 06/98 BOBBIN ADI 0.13 05C

+11.43 55 40 06/98 BOBBIN OXP 39.71 TSC

-1.01 56 65 06/98 BOBBIN OXP 36.04 TSH

-0.75 to

+0.00 56 93 06/98 BOBBIN ADI 0.14 04H

+14.25 57 72 06/98 BOBBIN ODI 1

0.14 04H

+20.04 06/98 BOBBIN ODI 1

0.14 04H

+20.04 58 47 06/98 BOBBIN ODI 1

0.25 04H

+25.13 06/98 BOBBIN ODI 2

0.17 06H

+23.36 06/98 BOBBIN ODI 14 0.25 02H

+29.14 06/98 MRPC H/L SI VOL 0.27 04H

+24.32 06/98 MRPC H/L SI VOL 0.37 02H

+28.66 06/98 MRPC H/L SI VOL 0.53 06H

+21.40 06/98 MRPC H/L SI VOL 0.54 06H

+23.08 06/98 MRPC H/L SI VOL 0.61 02H

+10.19 59 54 06/98 BOBBIN OXP 29.92 TEH

+24.69 06/98 BOBBIN OXP 29.92 TEH

+24.69 60 17 06/98 BOBBIN OXP 36.06 TEH

+3.70 63 32 06/98 BOBBIN OXP 30.08 TSH

-1.39 to

-0.38 63 124 06/98 BOBBIN ADI 0.27 05C

+3.40 06/98 BOBBIN ODI 1

0.38 04H

+29.49 06/98 BOBBIN ODI 1

0.46 OBH

+23.00 06/98 MRPC H/L SI VOL 0.37 04H

+29.50 63.130 06/98 BOBBIN ODI 11 0.10 05H

+16.85 64 57 06/98 BOBBIN ODI 1

0.47 02H

+23.12 06/98 MRPC H/L SI VOL 0.50 02H

+22.42 64 63 06/98 BOBBIN ODI 1

0.30 05C

+17.52 06/98 MRPC C/L SI VOL 0.21 05C

+17.32 64 71 06/98 BOBBIN ODI 1

0.23 03C

+6.61 64 85 06/98 BOBBIN OXP 28.22 TEC

+20.37 65 74 06/98 BOBBIN OXP 32.34 TSH

-1.10 66 97 06/98 BOBBIN ODI 1

0.45 06H

+27.94 68 43 06/98 BOBBIN ODI 1

0.33 04C

+23.11 69 80 06/98 BOBBIN ADI 0.27 02C

+16.60 70 91 06/98 BOBBIN ODI 1

0.67 03C

+37.78 06/98 MRPC C/L SI VOL 0.18 03C

+38.00 73 56 06/98 BOBBIN ODI 1

0.33 08H

+30.55 06/98 MRPC H/L SI VOL 0.47 OBH

+29.87 73 96 06/98 BOBBIN ADI 0.29 FBI

+6.22 06/98 BOBBIN ADI 0.31 FBI

+9.15 76 107 06/98 BOBBIN OXP 25.07 TSC

-1.17 to

+0.00 79 68 06/98 BOBBIN OXP 34.32 TSH

-0.94 to

-0.35 83 98 06/98 BOBBIN OXP

27. 74 TSH

-0.65 84 93 06/98 BOBBIN ODI 1

0.13 03H

+19.63 06/98 BOBBIN ODI 7

0.09 07H

+15.01 06/98 MRPC C/L SI VOL 0.49 03C

+10.74 06/98 MRPC H/L SI VOL 0.32 03H

+17.58 06/98 MRPC H/L SI VOL 0.52 07H

+15.03 06/98 MRPC H/L SI VOL 0.55 03H

+19.90 06/98 BOBBIN ODI 5

0.07 03C

+10.32 to

+13.12 85 120 06/98 BOBBIN ADI 0.15 04C

+28.22 86 69 06/98 BOBBIN OXP 35.91 TEC

+13.93 06/98 BOBBIN OXP 45.64 TSC

-1.26 86 103 06/98 BOBBIN ODI 1

0.57 FBB

+9.32 86 109 06/98 BOBBIN ADI 0.22 04C

+10.76 06/98 MRPC C/L SI VOL 0.25 04C

+10.78 90 101 06/98 BOBBIN ODI 1

0.13 06H

+24.00 06/98 BOBBIN ODI 2

0.27 06C

+5.94 06/98 MRPC C/L SI VOL 0.63 06C

+6.16 06/98 MRPC H/L SI VOL 0.23 OGH

+24.35

r1

    • 4**********'

FTI TUBAN II (Varsion 2.3) 04/12/1999 13 55:32 McGuire N.S. - Unit'Ona Rsplactmsnt

.eeeeeeee*****.

s/g p 06/38 RFO BOBBIN,MRPC C/L SI,MRPC H/L SI,MRPC UBEND SI

~,

Page 3 ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS i

INDS OF IMPERFECTIONS - SGD-ROW COL OUTAGE TEST TfPE IND %TW VOLTS LOCATION 91' 96 06/98 BOBBIN OXP-38.37 TEC

+0.00 to

+5.08 93 102 06/98 BOBBIN ODI 1

0.37 06H

+23.29 06/98 -MRPC H/L SI VOL

'O.52 06H

+23.64

95. 72 06/98 LOBBIN ODI 1

0.61 04C

+31.48 98 45 06/98 BOBBIN ODI 1

0.31 06C

+20.84

'06/98 MRPC C/L SI VOL 0.46 06C

+20.27 98 71 06/98 BOBBIN ODI 1

0.30 06C

+18.75 06/98 BOBBIN ODI 1

0.33 02C

+28.48 06/98 MRPC C/L SI VOL 0.48 06C

+18.78 06/98 MRPC C/L SI VOL 0.57 02C

+28.61 101 48 06/98 BOBBIN OXP 78.35 TEH

+5.74 110 63 06/98 BOBBIN OXP 58.21 TEH

+10.91 to

+20.96 110 71 06/98 BOBBIN OXP 59.17 TEH

+10.89 to

+21.93 110 97 06/98 BOBBIN OXP 26.88 TEH

+1.96

-112 ~ 67 06/98 BOBBIN ADI 0.12 OSC

+34.04 116 75 06/98 BOBBIN ADI 0.18 FB7

+9.46 06/98. MRPC C/L SI VOL 0.26 FB7

+10.53 Total Indications Found = 147

)

Total Tubes Found = 81 j

l 4

1 l

l I

e c*cocco FTI TUBAN II (Vcraicn 2.3) 04/12/1999 16:53:56 6600000 0000000 McGuiro N.S. - Unit One Replacement 00*****

coco ***

S/G A 000c***

06/98 RFO occo***,

Page 1 ATTACHMENT 5 - NO TUBES WERE PLUGGED IN THE 6/98 RFO FOR S/G A COUNT ROW COL

)

l Total Data Items Found = 0 Total Tubes Found = 0 t

i

C000000:

FTI TUBAN II (Varcion 2.3) 04/12/1999 16:50 15 0000000 0000000 McGuiro N.S. - Unit One Replacement

  • 00****

i coco ***

S/G B occo***

06/98 RFO C000***

Page 1 ATTACHMENT 6 - TUBES PLUGGED 6/98 RFO COUNT ROW COL 1.

24 121 Total Data Items Found = 1 Total Tubes Found = 1 i

1 e..

  • 000000*

FTI TUBAN II (Vcroion 2.3) 04/12/1999 16:51 05

      • 0***

0000000

~McGuire N.S.

- Unit One Replacement 0000***'

S/G C 0000***

06/98 RFO 0000***

ATTACHMENT 7 - TUBES PLUGGED 6/98 RFO COUNT ROW COL 1.

51 68 Total Data Items Found = 1 Total Tubes Found = 1 l

/

0$00000 FTI TUBAN II (Vcroion 2.3) 04/12/1999 16:52351 0000000

.0000000 McGuiro N.S. - Unit One Replacement 0000000 cocc***

S/G D 0000***

06/98 RFO 0000***

l ATTACHMENT 8 - NO TUBES WERE PLUGGED FOR THE 6/98 RFO IN SGD COUNT ROW COL Total Data Items Found = 0 Total Tubes Found = 0