Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
IR 05000321/1999009 | 7 October 1999 | Insp Repts 50-321/99-09 & 50-366/99-09 on 990607-11 & 0823- 27.One Violation Being Treated as Ncv.Major Areas Inspected: Maint & Engineering | Safe Shutdown Power Uprate |
IR 05000424/1999006 | 1 October 1999 | Insp Repts 50-424/99-06 & 50-425/99-06 on 990725-0904. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support | Job Performance Measure |
IR 05000321/1999005 | 16 September 1999 | Insp Repts 50-321/99-05 & 50-366/99-05 on 990711-0821.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | High Radiation Area Locked High Radiation Area |
IR 05000424/1999005 | 16 August 1999 | Insp Repts 50-424/99-05 & 50-425/99-05 on 990620-0724.No Violations Noted.Major Areas Inspected:Opertions, Engineering,Maintenance & Plant Support.Results of Announced Insp by Security Inspector Also Encl | Fitness for Duty Temporary Modification |
IR 05000321/1999004 | 4 August 1999 | Insp Repts 50-321/99-04 & 50-366/99-04 on 990530-0710.One Violation Noted & Being Treated as Ncv.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support | Offsite Dose Calculation Manual Annual Radiological Environmental Operating Report Power change |
IR 05000321/1999010 | 20 July 1999 | Insp Repts 50-321/99-10 & 50-366/99-10 on 990616-25.One Violation Occurred & Being Treated as Ncv.Major Areas Inspected:Aspects of Licensee Operations,Maint,Problem Identification & Resolution & Corrective Actions | Half scram Temporary Modification Condition Adverse to Quality |
IR 05000424/1999004 | 15 July 1999 | Insp Repts 50-424/99-04 & 50-425/99-04 on 990502-0619. Non-cited Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support | |
IR 05000321/1999003 | 25 June 1999 | Insp Repts 50-321/99-03 & 50-366/99-03 on 990418-0529.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support | Temporary Modification Power Uprate |
PNO-II-99-025, on 990615,CR Operators Manually Shutdown Unit 2 Reactor from 41% Power,Due to Decreasing Condenser Vacuum. Cause of Decreasing Vacuum Has Not Been Determined.All Rods Installed as Required & All Safety Sys Functioned Properly | 17 June 1999 | PNO-II-99-025:on 990615,CR Operators Manually Shutdown Unit 2 Reactor from 41% Power,Due to Decreasing Condenser Vacuum. Cause of Decreasing Vacuum Has Not Been Determined.All Rods Installed as Required & All Safety Sys Functioned Properly | |
IR 05000424/1999003 | 19 May 1999 | Insp Repts 50-424/99-03 & 50-425/99-03 on 990321-0501. Non-cited Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support | |
PNO-II-99-016, on 990505,Hatch Unit 2 Had Main Generator Trip Form 98% Power,Due to Electrical Fault.Licensee Continuing Investigation Has Been Hampered Due to Inclement Local Weather Conditions.Plant Being Depressurized | 7 May 1999 | PNO-II-99-016:on 990505,Hatch Unit 2 Had Main Generator Trip Form 98% Power,Due to Electrical Fault.Licensee Continuing Investigation Has Been Hampered Due to Inclement Local Weather Conditions.Plant Being Depressurized | |
IR 05000321/1999002 | 6 May 1999 | Insp Repts 50-321/99-02 & 50-366/99-02 on 990307-0417.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | High Radiation Area Weld Overlay Nondestructive Examination Temporary Modification Foreign Material Exclusion Scram Discharge Volume |
IR 05000424/1999002 | 15 April 1999 | Insp Repts 50-424/99-02 & 50-425/99-02 on 990214-0320. Violations Noted.Major Areas Inspected:Operations, Engineering,Maint & Plant Support | Coast down |
IR 05000321/1999001 | 2 April 1999 | Insp Repts 50-321/99-01 & 50-366/99-01 on 990124-0306.Non- Cited Violations Identified.Major Areas Inspected:Maint, Operations & Plant Support | Fire Barrier Fire Protection Program |
ML20207L851 | 8 March 1999 | Notice of Violation from Insp on 990125-27.Violation Noted: on Numerous Occasions from Mar 1997 to Oct 1998,select Response Force Officers Were Posted in Locations That Would Not Permit Them to Interpose Themselves Between Intruder | |
IR 05000424/1999001 | 8 March 1999 | Partially Withheld Insp Repts 50-424/99-01 & 50-425/99-01 on 990125-27 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Area of Plant Support by Regional Safeguards Inspector & Select Personnel from NRR | |
IR 05000424/1998010 | 3 March 1999 | Insp Repts 50-424/98-10 & 50-425/98-10 on 981227-990213.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support.Rept Covers 7-wk Period of Insp & Insps in Area of Health Physica & EP | Offsite Dose Calculation Manual Stroke time Siren |
IR 05000321/1998009 | 24 February 1999 | Insp Repts 50-321/98-09 & 50-366/98-09 on 981213-990123.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support.Rept Covers Insp in Health Physics & Independent Spent Fuel Storage | Operability Assessment |
IR 05000424/1998009 | 20 January 1999 | Insp Repts 50-424/98-09 & 50-425/98-09 on 981115-1226.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support | Boric Acid Probabilistic Risk Assessment |
IR 05000321/1998007 | 29 December 1998 | Insp Repts 50-321/98-07 & 50-366/98-07 on 981101-1212.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support | Power Uprate |
IR 05000424/1998008 | 11 December 1998 | Insp Repts 50-424/98-08 & 50-425/98-08 on 980927-1114.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support | Locked High Radiation Area |
IR 05000321/1998006 | 24 November 1998 | Insp Repts 50-321/98-06 & 50-366/98-06 on 980920-1031. Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support | Offsite Dose Calculation Manual |
IR 05000424/1998012 | 9 November 1998 | Partially Withheld Insp Repts 50-424/98-12 & 50-425/98-12 on 981005-09 (Ref 10CFR73.21)Major Areas Inspected:Physical Security Program for Power Reactors | |
IR 05000321/1998005 | 15 October 1998 | Insp Repts 50-321/98-05 & 50-366/98-05 on 980802-0919.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support.Insp Also Included Insps by Regional Maint & Emergency Preparedness | High Radiation Area Grab sample Fire Barrier Maintenance Rule Program |
IR 05000424/1998007 | 15 October 1998 | Insp Repts 50-424/98-07 & 50-425/98-07 on 980816-0926. Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support.Insp Also Addressed 980904 Reactor Trip | |
ML20155A762 | 15 October 1998 | Notice of Violation from Insp on 980816-0926.Violation Noted:On 980824,licensee Failed to Adequately Establish Sufficient Procedural Control for Demolition of Concrete Missile Barrier | |
PNO-II-98-040, on 980917,licensee Declared Notification of Unusual Event Based on Transport of Two Injured & Potentially Contaminated Individuals to Local Hospital.Two Individuals Found Not to Have Sustained Serious Injury | 18 September 1998 | PNO-II-98-040:on 980917,licensee Declared Notification of Unusual Event Based on Transport of Two Injured & Potentially Contaminated Individuals to Local Hospital.Two Individuals Found Not to Have Sustained Serious Injury | |
IR 05000424/1998006 | 10 September 1998 | Insp Repts 50-424/98-06 & 50-425/98-06 on 980628-0815.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support | Fitness for Duty High Radiation Area Hydrostatic Anchor Darling Temporary Modification Emergency Lighting Locked High Radiation Area Tornado Generated Missile Fire Protection Program Grace period |
ML20154C513 | 10 September 1998 | Notice of Violation from Insp on 980628-0815.Violation Noted:Corrective Actions Taken in Response to Violations Associated with Entry Into TS LCO for Maint & Surveillances Activities Were Inadequate to Preclude Repetition | High Radiation Area Locked High Radiation Area |
IR 05000321/1998004 | 21 August 1998 | Insp Repts 50-321/98-04 & 50-366/98-04 on 980621-0801.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support.Rept Includes Results of Insp by Regional Engineering & Safeguard | Safety Limit Minimum Critical Power Ratio High Radiation Area Temporary Modification Job Performance Measure Foreign Material Exclusion Safeguards Contingency Plan Scaffolding |
IR 05000424/1998011 | 31 July 1998 | Insp Repts 50-424/98-11 & 50-425/98-11 on 980622-26.No Violations Noted.Major Areas Inspected:Announced Insp Was Observation & Evaluation of Biennial Emergency Preparedness Exercise for Plant | Grab sample Siren |
ML20236T587 | 23 July 1998 | Notice of Violation from Insp on 980517-0627.Violation Noted:On 980419,Unit 2 Entered Mode 2 W/O Meeting LCO of TS 3.3.2,which Requires Two Trains of Turbine Trip Function to Be Operable Prior to Entering Mode 2 | |
IR 05000424/1998005 | 23 July 1998 | Insp Repts 50-424/98-05 & 50-425/98-05 on 980517-0627. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | High Radiation Area Pressure and Temperature Limits Report |
IR 05000424/1998302 | 21 July 1998 | NRC Operator Licensing Exam Repts 50-424/98-302 & 50-425/98-302 for Tests Administered on 980721 | |
IR 05000321/1998003 | 14 July 1998 | Insp Repts 50-321/98-03 & 50-366/98-03 on 980503-0620.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support,Including Fire Hazards Analysis Requirements | High winds High Radiation Area Fire Barrier Contraband Locked High Radiation Area Containment Hardened Vent Overtravel Hardened vent Liquid penetrant Fire Watch |
ML20236H408 | 15 June 1998 | Insp Repts 50-424/98-04 & 50-425/98-04 on 980419-0516. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Temporary Modification Foreign Material Exclusion |
ML20236H397 | 15 June 1998 | Notice of Violations from Insp on 980419-0516.Violations Noted:On 980415,upon Identification That 1 of 3 Letdown Orifice Isolation Valves Would Not Open,Unit 2 Uss Proceeded to Allow Operation of Unit in Water Solid Conditions | Foreign Material Exclusion |
PNO-II-98-032, on 980609,electrical Fault on 2C Condensate Pump Motor Caused Loss of 1NAB 13.8KV Bus.Fault Also Caused Main Generator Trip,Turbine Trip & Reactor Trip.Reactor Coolant Pump 2 & 4 Lost Power Because of Bus Loss | 10 June 1998 | PNO-II-98-032:on 980609,electrical Fault on 2C Condensate Pump Motor Caused Loss of 1NAB 13.8KV Bus.Fault Also Caused Main Generator Trip,Turbine Trip & Reactor Trip.Reactor Coolant Pump 2 & 4 Lost Power Because of Bus Loss | |
IR 05000321/1998002 | 1 June 1998 | Insp Repts 50-321/98-02 & 50-366/98-02 on 980322-0502.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Hot Short High Radiation Area Stroke time Temporary Modification Emergency Lighting Locked High Radiation Area |
ML20247K753 | 15 May 1998 | Notice of Violation from Insp on 980308-0418.Violation Noted:On 980401,Procedure PT-V-605,was Not Properly Implemented,In That,Liquid Penetrant pre-exam Cleaning for Safety Injection Sys Weld 21204-122-6 Was Inadequate | Liquid penetrant |
IR 05000424/1998003 | 15 May 1998 | Insp Repts 50-424/98-03 & 50-425/98-03 on 980308-0418. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Fitness for Duty High Radiation Area Nondestructive Examination Foreign Material Exclusion Liquid penetrant Fire Watch |
IR 05000424/1998301 | 7 May 1998 | NRC Operator Licensing Exam Repts 50-424/98-301 & 50-425/98-301 on 980413-15.Exams Results:All Candidates Passed Tests Except for One SRO | Boric Acid Shutdown Margin Safe Shutdown Earthquake Job Performance Measure Deep Dose Equivalent Power change |
ML20217N110 | 21 April 1998 | Notice of Violation from Insp on 980208-0321.Violation Noted:Maint Personnel Did Not Follow Procedures & Conducted Work That Was Not Specified on Maint Work Order Which Was Outside Approved Personnel Protection Clearance Boundary | High Radiation Area Grab sample VT-2 |
ML20217N131 | 21 April 1998 | Insp Repts 50-321/98-01 & 50-366/98-01 on 980208-0321. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support | Safe Shutdown High Radiation Area Grab sample Fire Barrier Contraband Temporary Modification VT-2 Emergency Lighting Locked High Radiation Area Maintenance Rule Program Fire Protection Program Fire Watch Power change |
ML20216J661 | 2 April 1998 | Notice of Violation from Insp on 980125-0307.Violation Noted:On 980219,Unit 2 Shift Supervisor Authorized Maint on Control Room Emergency Filtration Sys Train B W/O Recognizing Work Would Render Train Inoperable | |
IR 05000424/1998002 | 2 April 1998 | Insp Repts 50-424/98-02 & 50-425/98-02 on 980125-0307. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering | Missed surveillance Coast down |
PNO-II-98-017, on 980320,female Contract Worker Found Unconscious at Bottom of man-lift Station in Turbine Bldg. Plant First Aid Team Responded & Ambulance Was Called. Injured Person Transported to Hosp & Pronounced Dead | 20 March 1998 | PNO-II-98-017:on 980320,female Contract Worker Found Unconscious at Bottom of man-lift Station in Turbine Bldg. Plant First Aid Team Responded & Ambulance Was Called. Injured Person Transported to Hosp & Pronounced Dead | |
ML20216E793 | 10 March 1998 | Notice of Violation from Insp on 971228-980207.Violation Noted:As of 980207,measures Not Correctly Implemented in That Proposed Vendor Manual Change for Sys Not Submitted to Reflect Lower Set Point Requirement for PCV 2T48-F466 | |
ML20216E798 | 10 March 1998 | Insp Repts 50-321/97-12 & 50-366/97-12 on 971228-980207. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Hot Short Reactor Vessel Water Level Grab sample Offsite Dose Calculation Manual Contraband Exemption Request |
IR 05000424/1997012 | 23 February 1998 | Insp Repts 50-424/97-12 & 50-425/97-12 on 971214-980124.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Safe Shutdown Fitness for Duty Packing leak High Radiation Area Fire Barrier Stroke time Safe Shutdown Earthquake Coatings Locked High Radiation Area Exemption Request Earthquake Fire Protection Program Fire Watch |