NRC-02-0064, July 2002 Monthly Operating Report for Fermi 2

From kanterella
Jump to navigation Jump to search
July 2002 Monthly Operating Report for Fermi 2
ML022330532
Person / Time
Site: Fermi DTE Energy icon.png
Issue date: 08/12/2002
From: Peterson N
Detroit Edison
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NRC-02-0064, RG-1.016
Download: ML022330532 (4)


Text

Fermi 2 6400 North Dixie Hwy., Newport, M1 48166 Detroit Edison Reg. Guide 1.16 August 12, 2002 NRC-02-0064 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington D C 20555

Reference:

Fermi 2 NRC Docket No. 50-341 NRC Operating License No. NPF-43

Subject:

Monthly Operating Status Report for July 2002 Enclosed for your information and use is the Fermi 2 Monthly Operating Status Report for July 2002. This report includes the Operating Data Report, Average Daily Unit Power Level, and the Summary of Unit Shutdowns and Power Reductions identified in NRC Regulatory Guide 1.16 and Fermi 2 Technical Specification 5.6.4.

Should you have any questions or require additional information, please contact me at (734) 586-4258.

Sincerely, Norman K. Peterson Manager - Nuclear Licensing Enclosures cc: J. E. Dyer T. J. Kim M. A. Ring M. V. Yudasz, Jr.

NRC Resident Office Region III A DTE Energy Company

OPERATING DATA REPORT DOCKET NO. 50-341 COMPLETED BY Ron Stiemsma August 12, 2002 TELEPHONE (734) 586-1656 DATE OPERATING STATUS

1. Unit name: Fermi 2
2. Reporting period: July 2002
3. Licensed thermal power (MWt): 3430
4. Nameplate rating (Gross MWe): 1217
5. Design elect rating (Net MWe): 1150
6. Max dependable cap (Gross MWe): 1140
7. Max dependable cap (Net MWe): 1089
8. If changes occur in capacity ratings (Items number 3 through 7) since last report, give reasons:

N/A

9. Power level to which restricted, if any (MWe Niet): N/A
10. Reasons for restrictions, if any: N/A THIS MONTH YEAR TO CUMULATIVE DATE 744 5087 127,285
11. Hours in reporting period
12. Hours reactor was critical 744 5,087 96,723 0 0
13. Reactor reserve shutdown hours. 0
14. Hours generator on-line 744 5,087 92,985 0 0 0
15. Unit reserve shutdown hours 2,550,216 16,855,416 293,625,827
16. Gross thermal energy gen (MWH) 846,140 5,670,728 96,864,125
17. Gross elect energy gen (MWH) 808,970 5,434,823 92,626,243
18. Net elect energy gen (MWH) 100.0% 100.0% 73.1%
19. Unit service factor 100.0% 73.1%
20. Unit availability factor 99.8% 98.1% 75.1%(1)
21. Unit cap factor (using MDC Net) 94.6% 92.9% 70.4% (1)
22. Unit cap factor (using DER Net) 0.0% 0.0% 16.3%
23. Unit forced outage rate
24. Shutdowns scheduled over next 6 months (Type, Date, Duration of each): N/A
25. If shutdown at end of report period, estimated date of startup: N/A
26. Units in test status (prior to commercial operation): N/A Notes: (1) Calculated using weighted averages to reflect variations in rating (MDC and DER) from initial commercial operation.

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO. 50-341 UNIT Fermi 2 DATE August 12, 2002 COMPLETED BY Ron Stiemsma TELEPHONE (734) 586-1656 Month July 2002 DAY AVERAGE DAILY DAY AVERAGE DAILY POWER POWER LEVEL LEVEL (MWe-Net) (MWe-Net) 1 1078 17 1083 2 1079 18 1084 3 1082 19 1088 4 1080 20 1095 5 1097 21 1086 6 1097 22 1076 7 1093 23 1091 8 1088 24 1099 9 1087 25 1096 10 1096 26 1088 11 1102 27 1086 12 1103 28 1078 13 1099 29 1079 14 1094 30 1085 15 1088 31 1083 16 1087

UNIT SHUTDOWNS AND POWER REDUCTIONS COMPLETED BY: Ron Stiemsma DOCKET NO: 50-341 (734) 586-1656 UNIT NAME: Fermi 2 TELEPHONE:

DATE: August 12, 2002 REPORT MONTH July 2002 Date TYPE Dur (Hrs) (7) Reason (2) Method of LER Sys Code (4) Comp Cause and Corrective Action to No. (6) shutting down No. Code (5) Prevent Recurrence (1) reactor or reducing power (3)

N/A (2) REASON: (3) METHOD: (4) Instructions for preparation of data entry sheets (1) F: Forced for Licensee Event Report (LER) file (NUREG A - Equipment Failure (Explain) 1 -Manual S: Scheduled 1022)

B - Maintenance or Test 2 - Manual Scram 3 - Automatic Scram (5) Same Source as (4)

C - Refueling 4 - Continued (6) R - Prefix indicates power reduction.

D - Regulatory Restriction 5 - Reduced Load S - Prefix indicated plant shutdown.

E - Operations Training and License 9 - Other (7) Duration of reductions reported as zero per Examination Regulatory Guide 1.16, Revision 4.

F - Administrative

  • - Operational Error (Explain)

H - Other (Explain)