CD&L Carolina Power & Light Company DEC 17198tu ofC 23 q,. SERIAL:
NLS-86-405 Dr. 3. Nelson Grace, Regional Administrator United States Nuclear Regulatory Commission Suite 2900 101 Marietta Street, NW Atlanta, GA 30303 SHEARON HARRIS NUCLEAR POWER PLANT UNIT NO.1 - DOCKET NO. 50-400 EMERGENCY PREPAREDNESS EXERCISE
Dear Dr. Grace:
Carolina Power & Light Company (CP&L) has scheduled a full-scale emergency preparedness exercise for the Shearon Harris Nuclear Power Plant (SHNPP) for February 28,1987. This exercise is intended to fulfill the " full participation" exercise scope recuirements set forth in 10 CFR 50, Appendix E. This letter provides the scope of the February exercise and the objectives to be fulfilled (i.e., the 75-day submittal) as requested in the October 11,1984 letter from Mr. R. C. Lewis to Mr. E. E. Utley.
However, this submittal is being submitted af ter the requested 75-day schedule date as discussed between the staffs of CP&L and Region II.
The exercise will consist of a simulated accident at SHNPP which could escalate to a general emergency and will involve planned response and recovery actions to include:
emergency classification, notification of off-site organizations and plant personnel, actions to correct the emergency conditions, and initiation of accident assessment and protective actions as necessary to cope with the accident. The full-scale exercise will simulate an emergency that results in off-site radiological releases. Off-site participants in this exercise will include the State of North Carolina; the counties of Chatham, Harnett, Lee, and Wake; and support agencies necessary to implement their emergency response plans in support of SHNPP.
Objectives of this exercise are to:
Demonstrate the ability of the control room staff to perform accident assessment and implement those appropriate mitigating actions necessary to place the plant in a safe and stable condition.
Demonstrate the ability to augment the on-shif t emergency organization within the time limits specified within the emergency plan and implementing procedures.
Demonstrate the ability of response personnel to analyze current plant conditions, identify and project trends / potential consequences, and formulate near term mitigating actions.
Demonstrate the ability to identify and classify the emergency in accordance with the emergency plan.
8702090148 861217 PDR ADOCK 05000400 F
PDR c,,
p,..,,
411 Fayetteydle street
- P O Box 1551
- Raie gm N C 2760 QZ7""*T~&CTMQLZECIJE",CTL3 ZEjf
)
gg, G NRD. Mcjm [,
OFnN. %
e
d
- ~
Dr. 3. N:Ison Grcca DEC 171986
- NLS-86-405 / Paga 2 i
l j
Demonstrate the adequacy of procedures for alerting, notifying, and mobilizing emergency response personnel.
Demonstrate the timeliness and adequacy of the information provided in the initial notifications to state and county agencies.
j.
Demonstrate the ability to provide follow-up notifications to the state and j
county agencies.
Demonstrate the ability to formulate appropriate off-site protective action j
recommendations.
l Demonstrate the ability to communicate between emergency response facilities.
i Demonstrate the adequacy of the Operations Support Center in providing additional manpower support and coordination.
t Demonstrate the adequacy of the Technical Support Center in providing accident assessment and mitigation, dose assessment, and communication / notification activities, j
Demonstrate the adequacy of the Emergency Operations Facility in providing off-site dose assessment, environmen*al monitoring, protective action j
recommendations, and evaluation / coordination of off-site activities.
l Demonstrate the adequacy of emergency kits and equipment in emergency l
response facilities.
i j
Demonstrate the ability to perform on-site accountability as required by the i
I Demonstrate that adequate control measures have been established for plant access control.
j t
Demonstrate that emergency exposure guidelines have been established and are utilized in the decision-making process for determining emergency worker activities.
Demonstrate the capability to monitor personnel and equipment for contamination.
Demonstrate proper procedures for fire brigade response to the type of fire chosen for the exercise.
Demonstrate the adequacy of the interface between off-site fire support personnel and the plant fire brigade.
Demonstrate the ability to coordinate news releases with state and county personnel.
Demonstrate the capability to coordinate the preparation, review, and release of information to the general public.
I
(
.Dr. 3. N:Ison Gr c*
DEC 171986 NLS-86-405 / P g2 3 Demonstrate the adequacy of the equipment utilized for off-site radiological monitoring.
Demonstrate the ability to coordinate of f-site radiological monitoring activities.
Demonstrate the ability of designated dose assessment personnel to determine dose to the public.
Demonstrate the ability of personnel responsible for dose estimation to integrate field measurements and dose projections into protective action decision making.
Demonstrate the ability to reassess plant conditions and evaluate recovery considerations as defined by the plant emergency plan, if you have any questions on this subject, please contact us.
Yo s.very tr ly,
$@ ^ ah A. B. Cutter - Vice President Nuclear Engineering & Licensing ABC/SDC/bmc (50875DC) cc: