ML18005B151

From kanterella
Jump to navigation Jump to search
Forwards 15-day Special Rept Identifying Number of Steam Generator Tubes Plugged During Current Inservice Insp Period
ML18005B151
Person / Time
Site: Harris Duke Energy icon.png
Issue date: 11/17/1989
From: Richey R
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
HO-890131-(O), NUDOCS 8911280312
Download: ML18005B151 (3)


Text

b,CCELERATED DILUTION DEMONSTI+TION SYSTEM REGULATORY INFORMATXON DISTRIBUTXON SYSTEM (RIDS)

ACCESSION NBR: 8911280312 DOC. DATE: 89/11/17 NOTARIZED: NO FACIL:50-400 Shearon Harris Nuclear Power Plant, Unit 1, Carolina AUTH.NAME AUTHOR AFFXLXATION RICHEY,R.B.

Carolina Power 6 Light Co.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

DOCKET g

05000400 R

SUBJECT:

Forwards special rept identifying number of steam generator tubes plugged during current xnservice insp period.

I DISTRIBUTION CODE:

A047D COPIES RECEIVED:LTR J ENCL i SIZE:

D TITLE: OR Submittal: Inservice Inspection/Testing/Relief from ASME Code S

NOTES:Application for permit renewal filed.

05000400

/

RECIPIENT ID CODE/NAME PD2-1 LA BECKER,D INTERNAL: ACRS NRR/DET/ECMB 9H NUDOCS-ABSTRACT OGC/HDS 1 RES/DS IR/EIB EXTERNAL: EGGG BROWN, B LPDR NSIC COPIES LTTR ENCL 1

0 1

1 6

6 1

1 1

1 1

0 1

1 1

1 1

1 1

1 RECIPXENT XD CODE/NAME PD2-1 PD AEOD/DS P/TPAB NRR/DET/EMEB 9H OC/LFMB RE 01 EG&G ROCKHOLD,H NRC PDR COPIES LTTR ENCL 5

5 1

1 1

1 1

0 1

1 1

1 1

1 D

D R

D NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEEDI TOTAL NUMBER OF COPIES REQUIRED:

LTTR 26 ENCL 23 A

D D

'ipse S

Carolina Power 8 Light Company HARRIS NUCLEAR PROJECT P. 0.

Box 165 New Hill, North Carolina 27562 N0yi V 1989 File Number.'HF/10-13510 Letter Number.

HO-890131 (0)

United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 SHEARON HARRIS NUCLEAR POWER PLANT Docket No. 50-400, License NPF-63 15 DAY SPECIAL REPORT Gentlemen:

Enclosed is a Special Report pursuant to Technical Specification 4.4.5.5.a.

which identifies the number of steam generator tubes plugged during the current Inservice Inspection period.

The complete results of the steam generator tube Inservice Inspection will,be submitted within 12 months as required by Technical Specification 4.4.5.5.b.

Yours very truly, R. B. Richey, Mana er Harris Nuclear Project AJH'kdl Enclosure cc'.

Mr. R. A. Becker Mr. S.

B. Ebneter Mr. J.

D. Tedrow 8911280312 89'1117 PDR ADOCK 05000400 O

PDC MEM/HO-8901310/1/OS4

SPECIAL REPORT STEAM GENERATOR TUBE INSERVICE INSPECTION NUMBER OF TUBES PLUGGED Steam Generator.

Current*:

Cumulative'.

10 10

+ Identifies steam generator tubes plugged for Inservice Inspection completed on November 7, 1989.

MEM/HO-8901310/2/OS4