ML20202J243

From kanterella
Jump to navigation Jump to search
Change Notice 001 to Rev 0 to Quality Instruction QI-062, Insp of Nonpressure Boundary Welds for Supplementary Evaluation of Visual Welding Insp Techniques
ML20202J243
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 12/18/1985
From: Patterson A
EVALUATION RESEARCH CORP.
To:
Shared Package
ML20202J051 List: ... further results
References
QI-062, QI-62, NUDOCS 8607170047
Download: ML20202J243 (2)


Text

.-

. ).

Pcg31 of 2 9

EVALUATION RESEARCH CORPO T70]50CDPy

. coy 7ao COMANCHE PEAK RESPONSE TEAM QUALITY INSTRUCTION FOR ISSUE-SPECIFIC ACTION PLAN ISAP VII.c CHANGE NOTICE: 001 INSTRUCTION NO: QI-062 REVISION NO: 0 ISSUE DATE: 12/18/85

( INSPECTION OF NON-PRESSURE BOUNDARY WELDS FOR A SUPPLEMENTARY EVALUATION OF VISUAL WELDING INSPECTION TECHNIQUES Prepared by:

v 4- Date: lZ I6 \ 8I f/ t Approved by: I* [f C+1 * ~ Date: I k 'I #

Issue Coordinator Approved by: . Dater /j-/8'6 On-Site QA Representative O Approved by: Dater /2- 8 8'i~

/

QA/p Review Team Leapr /

l A K

)

Ch ngs Nstico 001 i 01-062 Revision 0 Revise 2.0 Applicability to read:

This procedure applies to the visual inspection of a sample of completed, inspected, and accepted by TUGC0 safety related non-pressure boundary welds being conducted by the QA/QC Review Team in accordance with ISAPs VII.b.3, Pipe Support / Inspections VII.b.5, Electrical Raceway Support Inspections, and VII.c, Construction Reinspection / Documentation Review Plan.

h O

O 2