ML20202J169

From kanterella
Jump to navigation Jump to search
Addendum 1 to Rev 0 to DAP-7, Trending & Generic Implications Evaluations
ML20202J169
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 05/20/1986
From:
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
Shared Package
ML20202J051 List: ... further results
References
DAP-7-ADD-01, DAP-7-ADD-1, NUDOCS 8607170035
Download: ML20202J169 (2)


Text

_ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _

l. COMANCIE PEAK RESPONSE TEAM DESIGN ADEQUACY PROGRA,M ADDEPOUM Procedure: DAP-7 Revision: 0 Addendum: 1

Title:

TRENDING AND GENERIC IMPLICATIONS EVALUATIONS

, PURPOSE This oddendum corrects two significant errors in the original issue (Rev. 0) of DAP-7.

SCOPE Replace the Table of Contents (poge 11) of DAP-7, Rev. O, with the corrected page ottoced.

Correct line 9 of Section 4.1 of DAP-7, Rev. 0 (pege 10) by changing " cost-discipline" to " cross-discipline."

INSTRUCTION This addendum is effective upon opproval and shall remain in effect until opproval of the next revision of DAP-7. This addendum shall be securely attached to each controlled copy of DAP-7.

Prepared by: n.k Date: MAY 15 W Reviewed by: .' km mf Date: IT Approved by:

y Date: .%

8607170035 PDR 860711

^ ADOCK 05000445 PDR .

CONTROLLED CCPY No. S -]

TN-86-6262/7

_ _ ___ _ _ _ _ _ _ _ A

g TABLE Cf CONTENTS Sectica . Poae

{- .

Cover Sheet ................................................... I Tab le of Con ten ts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . II I.0 P URP OS E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I 2.0 SCOPE................................................... I

. 3.0 DEFINITIONS AND RESPONSIBILITIES . . . . . . . . . . . . . . . . . . . . . . . 1 4.0 I NS TR UCTI ON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 5.0 DO C U ME NT AT I ON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 l

ATTACHMENTS '

A EXAMPLE ATTRIBUTES MATRIX . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 s

B TRE ND EVALU ATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-l C GENERIC IMPLICATIONS EVALUATION ENGIEERING EVALUATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1 D EXAMPLE LIST OF POTENTIAL ROOT CAUSES OR C AUS AL F ACTORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-l E EXAMPLE QUESTIONS FOR EVALUATION OF POTENTI AL ROOT CAUSES OR CAUS AL FACTORS . . . . . . . . . . . E-l i F TREND EVALUATION FORM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-1 i

G PGIDATA FIELD CODE FORM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G-1

~

H TREND EVALU ATION LOG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H-1 i SU M M ARY OF D AP-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 TN-85-6262/7 li