ML20034E247

From kanterella
Jump to navigation Jump to search
Sy C-Hatch 15-20 - Health Physics Sample Records
ML20034E247
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 06/18/2014
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034E247 (10)


Text

Sample ID:

142445 Type: RLSSS Type Detail: SAND

==

Description:==

1405288D 15 STAR 15-20 Dirt Sample Common Resp Org: P4000 - PROJECT MANAGEMEt

Contact:

COOPER, TERRY L Reference ID:

Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:

LQr"i_gin I Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 05/30/14 08:35 Mat. SizeNolume:

2097 GRAMS Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00

==

Description:==

STAR 15 SOIL SAMPLE Collection Sample Tech: DYNES, WILLIAM J Tritium Req:

No instructions:

Comments:

COUNT TO MDA I RLSSS 1 Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes 1 Cocatfon I Unit: NON-UNIT RE Stored By:,

Sample Loe:

Other:

Material Loe:

06/18/2014 11:53 Area: MS Sample Date: 05/29/14 07:40 Sample SizeNoiume: 2097 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

P' Elev: 100 Room:

Depth: 3" (in.)

Equip ID:

Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Sample ID:

142445 Type: RLSSS Type Detail: SAND

==

Description:==

140528BD 15 STAR 15-20 Dirt Sample I An-a,:vsis I Geometry, ___ _

MCA ID Quant.

Units C_ 1 L_marinelli_sand_

30304 2097GR Isotope Mode Activity Activity Uncert.

0 K-40 NT 9.936E-6 1.13E-6 0

TL-208 NT 2.805E-7 7.06E-8 0

PB-212 NT 5.267E-7 1.066E-7 0

Bl-214 NT 5.03E-7 8.82E-8 0

PB-214 NT 3.503E-7 1.742E 0 RN-222 NT 0.0001316 0.000046 0

BE-7 AP 6.7213E-7 0

MN-54 AP 1.1492E-7 0

MN-56 AP 9.7587E-8 0

C0-57 AP 7.1856E-8 0

C0-58 AP 6.2813E-8 0

C0-60 AP 4.9163E-8 0

SB-124 AP 6.4602E-8 0

SB-125 FP 4.4232E-8 0

CS-134 FP 2.6403E-8 0

CS-137 FP 1.1282E-7 I Analysis Review I Method LLD/MDA r

r r w

~

Iv

~

lv

~

Iv lv lv Iv Health Physics Sample Records Status: APPROVED FP/AP Lab Analysis E3y_

.000 PARK, MICHAEL C

%Abund.

Atom. No.

Comments 6.939%

40 0.196%

208 0.368%

212 0.351%

214 0.245%

214 91.902%

222 0.000%

7 0.000%

54 0.000%

56 0.000%

57 0.000%

58 0.000%

60 0.000%

124 0.000%

125 0.000%

134 0.000%

137 Re-Analize:

No Lie Rad Mat Present:

No Reviewed: COOPER, TERRY L HP Notified Name:

Hp Eng Rvw Reqd:

Yes Comments:

06/18/201411:53 Rad Mat Present:

Yes Rasterized: r Date Mod ID Mod Date 06/02/14 13:43 Mod Id Mod Date Date: 06/10/1410:05 Page 2 of 3

Sample ID:

142445 Type: RLSSS Type Detail: SAND

==

Description:==

140528BD 15 STAR 15-20 Dirt Sample I Review/App-rov~

Reviewed: COOPER, TERRY L Comments:

Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/18/2014 11:53 Health Physics Sample Records Status: APPROVED Rasterized: r HP Eng Review Date: 06/10/1410:06 Disposition Result: Sample contains only natural isotopes Final Ae_eroval Date: 06/10/14 10:06 Page 3 of 3

SONGS HEALTH PHYSICS REPORT 2-JUN-2014 13:32

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140528BD 15 STAR 15-20 DIRT SAMPLE

  • ID 30304 Acquisition date: 2-JUN-2014 13:29:50. *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 2-JUN-2014 13:29:00.

2-JUN-2014 13:29:00.

Counting System 2.09700E+03 GR IHPS Sample Number:

C lL marinelli_sand_l Analysis Library Operator: MICHAEL PARK U2GSP 142445 HP NATURAL

>>>>> C #41-TP11750A PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.39 0 00:03:00.45 0.0%

l.OOOOOE+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity l-JUN-2014 20:29:

-1.46898E-01 4.99817E-01

1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1

76.97 57 53 3.01 154.29 148 10 27.5 4.84E+OO BI-214 PB-212 PB-214 1

238.63 66 34

1. 33 477.70 473 9 20.2 l.88E+OO PB-212 1

295.33 16 18

1. 00 591.14 586 8 49.7 6.09E-01 PB-214 1

351. 78 44 2

1. 24 704.08 700 8 16.8 2.44E+OO PB-214 1

510.59 17 6

2.29 1021. 78 1015 11 34.9 1. 48E-01 RN-222 TL-208 1

583.00 23 3

1. 34 1166.62 1161 11 25.2 5.09E-01 TL-208 1

609.17 33 0

1. 41 1218.97 1214 10 17.5 2.22E-01 BI-214 1

1460.49 82 0

1. 66 2921.71 2916 11 11. 4 1.19E+OO K-40

Summary of Nuclide Activity Sample ID : 30304 Total number of lines in spectrum Number of unidentified lines Page :

2 Acquisition date 2-JUN *-2014 13 : 2 9 : 5 0 Number of lines tentatively identified by NID 8

0 8

100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 1.28E+09Y

1. 00 9.936E-06 9.936E-06 1.130E-06
11. 37 A

TL-208 3.0SM

1. 67
1. 676E-07 2.805E-07 0.706E-07 25.17 A

PB-212 10.64H

1. 00 5.254E-07 5.267E-07 l.066E-07 20.25 A

BI-214 19.90M

1. 08 4.636E-07 5.030E-07 0.882E-07 17.53 A

PB-214 26.80M

1. 06 3.297E-07 3.503E-07 l.742E-07 49.74 A

RN-222 3.83D

1. 00 1.315E-04 l.316E-04 0.460E-04 34.94 A

Total Activity 1.429E-04

1. 431E-04 Grand Total Activity :

1.429E-04 1.431E-04 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30304 None Flags: "T" Tentatively associated Page :

3 Acquisition date 2-JUN-2014 13:29:50

Interference Report Sample ID : 30304 No interference correction performed Acquisition date Page :

4 2-JUN-2014 13:29:50

Nuclide Line Activity Report Page :

5 Sample ID : 30304 Acquisition date 2-JUN-2014 13:29:50 Nuclide Type: naLural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 82 10.67*

5.560E-01 9.936E-06 9.936E-06

11. 37 TL-208 72.80 2.14 1.486E+OO Line Not Found ------

74.97 3.60 1.577E+OO Line Not Found ------

84.79 ------

1. 27 1.917E+OO Line Not Found ------

252.45 ------

0.80 2.004E+OO Line Not Found ------

277.28 6.80 1.917E+OO Line Not Found ------

510.61 17

21. 60
1. 298E+OO 4.262E-07 7.133E-07 34.94 583.02 23 86.00*

1.158E+OO

1. 676E-07 2.805E-07 25.17 763.06 ------
1. 64 8.934E-01 ------

Line Not Found ------

860.30 ------

12.00 7.922E-01 ------

Line Not Found ------

PB-212 74.81 ------

10.50

1. 570E+OO Line Not Found ------

77.11 57 17.70

1. 656E+OO 1.388E-06 1.392E-06 27.52 87.19 ------

6.27

1. 983E+OO Line Not Found ------

90.13 ------

1. 86 2.055E+OO Line Not Found ------

115.12 0.59 2.376E+OO Line Not Found ------

238.58 66 43.60*

2.055E+OO 5.254E-07 5.267E-07 20.25 300.03 ------

3.34 l.843E+OO Line Not Found ------

BI-214 76.86 57 0.58 1.656E+OO 4.237E-05 4.597E-05 27.52 79.29 ------

0.97

1. 741E+OO ------

Line Not Found ------

609.31 33 46.10*

1.112E+OO 4.636E-07 5.030E-07 17.53 665.44

1. 56 1.023E+OO Line Not Found ------

768.35 ------

4.88 8.873E-01 ------

Line Not Found ------

806.16 ------

1. 23 8.454E-01 ------

Line Not Found ------

934.04 3.16 7.310E-01 ------

Line Not Found ------

1120.27 15.00 6.242E-01 ------

Line Not Found ------

1155.18 ------

1. 69 6.105E-01 ------

Line Not Found ------

1238.11 ------

5.92 5.846E-01 ------

Line Not Found ------

1280.95 ------

1. 47 5.747E-01 ------

Line Not Found ------

1377. 66 4.02 5.602E-01 Line Not Found ------

1385.30 ------

0.78 5.595E-01 ------

Line Not Found ------

1401.48 ------

1. 39 5.583E-01 Line Not Found ------

1407.97 ------

2.48 5.578E-01 Line Not Found ------

1509.22 ------

2.19 5.568E-01 Line Not Found ------

1583.22 0.72 5.628E-01 Line Not Found ------

1661. 26 ------

1.15 5.753E-01 Line Not Found ------

1729.58 ------

3.05

5. 918E-01 Line Not Found ------

1764.49 ------

15.90 6.023E-01 ------

Line Not Found ------

1847.41 ------

2.12 6.331E-01 ------

Line Not Found ------

PB-214 53.17 ------

1.10 5.203E-01 ------

Line Not Found ------

74.81 ------

6.52 1.570E+OO Line Not Found ------

77.11 57

11. 00 l.656E+OO 2.234E-06 2.374E-06 27.52 87.19 ------

3.88 1.983E+OO Line Not Found ------

90.13 1.15 2.055E+OO Line Not Found ------

241. 92 7.46 2.043E+OO Line Not Found ------

258.94 0.55

1. 981E+OO Line Not Found ------

295.09 16 19.20*

1.858E+OO 3.297E-07 3.503E-07 49.74 351. 87 44 37.10

1. 686E+OO 5.082E-07 5.400E-07 16.82 785.83
1. 09 8.674E-01 Line Not Found ------

839.00 ------

0.59 8.122E-01 Line Not Found ------

Nuclide Line Activity Report (continued)

Sample ID : 30304 Acquisition date Page :

6 2-JUN-2014 13:29:50 Nuclide Type: natural Nuclide RN-222 Flag: "*"

Energy 510.00 Keyline Area 17

%Abn 0.07*

%Eff

1. 298E+OO Uncorrected Decay Corr uCi/GR uCi/GR 1.315E-04 l.316E-04 1-Sigma

%Error 34.94

Minimum Detectable Activity Report Page :

7 Sample ID 30304 Acquisition date 2-JUN-2014 13:29:50 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

5.

477.61

6. 7213E-07 MN-54
5.

834.83 1.1492E-07 MN-56

3.

846.81 9.7587E-08 C0-57

15.

122.06 7.1856E-08 C0-58

1.

810.79 6.2813E-08 C0-60

0.

1173.24 4.9163E-08 SB-124

2.

602.73 6.4602E-08 SB-125

0.

427.88 4.4232E-08 CS-134

0.

795.87 2.6403E-08 CS-137

6.

661.66 l.1282E-07