(o3 Report Nos. 50-416/81-08 and 50-417/81-05 Licensee: Mississippi Power and Light Company Port Gibson, MS Facility Name: Grand Gulf Docket Nos. 50-416 and 50-417 License Nos. CPPR-118 and CPPR-119 Inspection at Grand Gulf site near Port Gibson, MS Inspector Y Y b

&

W~A C ~ ?l n

J. R. Harris Date Signed Approved b Y-Zo ~ Il T. E. Conlon, Section Chief Oate Signed Engineering Inspection Branch Engineering and Technical Inspection Division SUMMARY Inspected on April 7-10, 1981 Areas Inspected This routine, unannounced inspection involved 28 inspector-hours onsite in the areas of structural concrete, steel structures and supports and previously identified items.

Results Of the three areas inspected, no violations or deviations were identified.

8106230%l

,

-

-,

,

o

,

.

.

REPORT DETAILS 1.

Persons Contacted Licensee Employees

  • G. B. Rogers, Site Manager
  • J. W. -Yelverton,'QA Field Supervisor
  • W. M. Garner, QA Representative
  • R. C. Fron, Nuclear Plant Engineering Other Organizations
  • M. R. Lindsey. Project Quality Assurance Supervisor, Bechtel
  • A. S. Bettencourt, Quality Assurance Engineer, Bechtel G. McClaim, Lead Civil Engineer, Bechtel L. Young, Resident Superintendent, PT&L NRC Resident Inspector
  • A. C. Wagner

" Attended exit interview 2.

Exit Interview The inspection scope and findings were summarized on April 10, 1981 with those persons indicated in paragraph 1 above.

3.

Licensee Action on Previous Inspection Findings a.

(Closed) Infraction (416/79-26-06) - Failure to calibrate test sieves.

The inspector examined the licensees responses dated November 6, 1979 and December 20, 1979.

Test sieves are now being controlled and calibrated in accordance with PT&L procedure IS-SU-CAL. This item is closed.

b.

(Closed) Infraction (416/80-20-01) - Failure to control cutting of rebar. The inspector examined the licensee's response dated July 21, 1980 and November 17, 1980. Project Specification C-103 and procedure WP/P-C-24 have been revised to more precisely define the approval authorities required for rebar cutting.

Responsible engineers and craft have been retrained in the new requirements.

Examination of ongoing work showed that cutting of rebar is being controlled in accordance with revised procecures and specifications. This item is closed.

...

,. -

.

es

c.

'(Closed) Inspector Followup Item (416/80-12-02 - Review of rebar cut log. Concrete reinforcing steel. cut during installation of concrete expansion ' anchors is reported on the rebar cut log which is sent to Bechtel-Gaithersburg for engineering evaluation. This item was identi-fied by the NRC inspector in report 80-12 because there was no recorded information to ensure that the results of the rebar cut log was being evaluated by Bechtel-Gaithersburg. Examination of MP&L's audit number 9 of Bechtel Gaithersburg and discussions with R. Fron, responsible MP&L auditor, showed that the rebar cut log is being evaluated and that no structural problems have been found. This item is closed.

4.

Unresolved Items Unresolved items were not identified during this inspection.

5.

Independent Inspection Effort a.

The inspector examined the following areas:

(1) Results of concrete work in the Unit 1 power block; (2) Calibration controls in the soils and concrete testing laboratory.

6.

Containment (Steel Structures and Supports) - Review of Quality Records -

Unit 1 The quality records associated with the installation of the reactor vessel support pedestal, the reactor vessel shield wall and lower and upper supports of the four RHR heat exchanger were examined for confirmation of installation requirements. Acceptance criteria examined by the inspactor appear in the following documents:

a.

Drawing numbers C-1070A, C-10708, C-1071A, Reactor Vessel Support Pedestal, Ring Girder and CR0 Embedments b.

Drawing numbers C-1068A,10688,1069 - Reactor Vessel Shield Wall c.

Drawing numbers C-13650R8, G1365ER7 - RHR Heat Exchanger Structural Steel Lower and Upper Supports Installation records examined by the inspector appear in the following work packages, QIM10-W-11209 MOA - Ring Girder, Containment Shield Wall Base Assembly a.

b.

QIM25-U-1119 YOA - Leveling of RPV Ring Girder c.

QIM22-V-11285 BOA - Structural Stee! Report Number 8 - Shield Wall Erection.;

'

c..

--

..

.

,

,

,.

d.

QIM25-W-1174-W1A - Containment RPV Shield Wall Concrete Placement e.'

QIT10-V-00245 BOA,' Area 7 - RHR Heat Exchanger f.

. IT10-V-00245 BOA, Area 8 - RHR Heat Exchanger Q

No violations or deviations were identified.

L 7.

Licensae Identified Items (LII) 10 CFR 50.55(e)

a.

(0 pen) LII 416/80-26-06 and 416/80-13-06, Control or rebar cut without project engineering approval.

The inspector examined the licensee's reports dated July 21, 1980 and November 17, 1980. Applicable speci-fications and procedures have been revised to clarify controls on cutting of rebar and responsible engineers have been retrained in revised controls on rebar cutting. Engineering evaluation of previous

,

unreported rebar cutting will be presented in MP&L's final report by August 1, 1981.

b.

(0 pen) LII_416/80-20-18 and 417/80-13-18, Expansion anchor installation.

without project engineering approval.

The inspector exanined the lice'nsee's reports dated November 11, 1980 and March 10, 1981. The constructors work plan procedure WP/P-C-24 has been revised to require certifictaion of all installers. Craft and responsible engineers have been retrained in revised installation requirements. MP&L's evaluation of Bechtel's investigation of this item will appear in a final report by September 24, 1981