05000311/LER-1982-001, Supplemental LER 82-001/03X-1:on 820110,steam Generator 24 Pressure Channel 4 Failed High.Caused by Ventilation Damper Stuck Open,Freezing Pressure Sensing Line.Damper Freed, Exercised & Closed

From kanterella
(Redirected from 05000311/LER-1982-001)
Jump to navigation Jump to search
Supplemental LER 82-001/03X-1:on 820110,steam Generator 24 Pressure Channel 4 Failed High.Caused by Ventilation Damper Stuck Open,Freezing Pressure Sensing Line.Damper Freed, Exercised & Closed
ML20082K672
Person / Time
Site: Salem PSEG icon.png
Issue date: 11/11/1983
From: Rupp J, Zupko J
Public Service Enterprise Group
To: Murley T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
LER-82-001-03X-01, LER-82-1-3X-1, NUDOCS 8312050270
Download: ML20082K672 (4)


LER-2082-001, Supplemental LER 82-001/03X-1:on 820110,steam Generator 24 Pressure Channel 4 Failed High.Caused by Ventilation Damper Stuck Open,Freezing Pressure Sensing Line.Damper Freed, Exercised & Closed
Event date:
Report date:
3112082001R00 - NRC Website

text

'

.~o_

(7 77)

LICENSEE EVENT REPORT CONTRQL BLOCK: l l l l l l lh (PLEASE PRINT CR TYPE ALL CEOUIEED INFOEMATCN)

. t 6

@ lN 9l J l LICENSEE 7 S lC CODE lS l 2 l@16 ol ol -l 0l 14 Ol NUMBER LeCENSE 0l 0l 0l -l 0l 0l@26l 26 4 l 1lTYPE LILENSE 1l JQ 1] 1l@l l

67 C A1 b6 l g, C

7 8 R$ 60l Lhl 61Ol SI OI OI Ol 3I il l hl DOCKET NUMBER 68 069l 1 lEVENT 1l0 l 8 l 2 @l1 DATE 74 75 l1 MEPORT l1 l 1DATEl 8 l380l@

EVENT DESCRIPTION AND PROB ABLE CONSEQUENCES h

[O T31 lon January 10, 1982, a control room operator observed that the No. 24. Steam Generator l O 3 IPressure Channel 4 had failed high. At 0300 hours0.00347 days <br />0.0833 hours <br />4.960317e-4 weeks <br />1.1415e-4 months <br />, pressure channel 4 was declared l O 4 l inoperable and Technical Specification Action Statement 3.3.2 Action 14 was entered. l TO TT1 1 I O 6 l l 10171 I I ITTin I I 7 8 9 80 DE CO E S SC E COv*0NENT CODE SUB DE S E ITITI 7 8 I; ic l@ Lc_J@ Lz_J@ l 11 ul si TI al ul@ LE_jh [ZJ h 9 11 12 to 13 18 19 20

_ SEQUENTI AL OCCUR R E NCE REPORT REvislON LER RO EVENT YE AR R EPORT NO. COOE TYPE NO.

h RE RT l 8 l2 l 21 22 b

23 l0l0l1l 24 Z l0 l3 l ] b l1 l 26 27 28 29 30 31 32

/~ K N AhYO ON PL NT ME HOUR 5 58 i FOR 8, SUPPLI MAN ACTURER

('" Ug]34Z [g 33 l35Zlg y M

@ l0l0l0lul 37 40 gg 41

{g 42 lN lg lZ 43 u l9 [9 l9 lg 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h l i l 0 l lThe ventilation damper had stuck open, freezing the pressure sensing line. The g l damper was freed, excercised and closed; the sensing line was thawed, tested, and g greturned to service. At 0325 hours0.00376 days <br />0.0903 hours <br />5.373677e-4 weeks <br />1.236625e-4 months <br />, January 10, 1982, Action Statement 3.3.2 g

,,,3, gAction 14 was terminated. DCR 2SC-0160, completed November 11, 198,3, installed g

, , gpenetration area temperature monitoring, g 7 8 9 80 SiA S  % POWER OTHER STATUS DIS RY Li?COVERY DESCRIPTION l1 l5l Wh l 0l 9l 7l@l NA l l A l@l operator observation l ACTIVITY CO TENT rELE AsED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE

[1 6 7 8 9 d h d@l 10 11 NA 44 l l 46 NA 80 l

PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION ii_L7J 'l 0l 01 Ol@l Zl@l NA I PERSONNE L INJURIES l

NUv8ER " DESCRIPTION l i a

'7 8 9

[ d 0l Ol@l u 12 NA I so S C,7 OR DAMAGE TO FACILITY i

TYPE DESCRIPTION 43 $h b d h! NA fl  !

l' '

  • PustiETY 8312050270 831111 I NRc mE ONW I

issut DESCRIPTION h PDR ADOCK 05000311 ,

!?

d 8 9 hl 10 NA S PDR l 68 69 lJlllllllllll}

80 E

  • NAME OF PREPARER PHONE:

~

~ O PSIEG Public Service Electric and Gas Company P.O. Box E Hancocks Bridge, New Jersey 08038 Salem Gene ating Station November 11, 1983 Dr. Thomas E. Murley Regional Administrator USNRC Region 1 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Dr. Murley:

LICENSE NO. DPR-75 DOCKET NO. 50-311 REPORTABLE OCCURRENCE 82-001/03X-1 SUPPLEMENTAL REPORT Pursuant to the requirements of Salem Generating Station Unit No. 2 Technical Specifications, Section 6.9.1.9.b, we are submitting supplemental Licensee Event Report for Reportable Occurrence 82-001/03X-1.

Sincerely yours, feb 9-J. M. Zupko, Jr.

General Manager -

Salem Operations JR:kll CC: Distribution o'

The Energy People 40

% 2139 (2uMI 1) 81

1 4 4

Report Number: 82-001/03X-1 Report Date: 11-11-83 Occurrence Date: 01-10-82 Facility: Salem Generating Station, Unit 2 Public Service Electric & Gas Company Hancocks Bridge, New Jersey 08038 IDENTIFICATION OF OCCURRENCE:

No. 24 Steam Generator Pressure Channel 4 - Inoperable.

This report was initiated by Incident Report 82-008.

CONDITIONS PRIOR TO OCCURRENCE:

Mode 1 - Rx Power 97% - Unit Load 1080 MWe DESCRIPTION OF OCCURRENCE:

On January 10, 1982 the operator noticed that No. 24 Steam Generator Pressure Channel 4 had failed high. At 0300 hours0.00347 days <br />0.0833 hours <br />4.960317e-4 weeks <br />1.1415e-4 months <br /> the pressure channel was declared inoperable and Action Statement 3.3.2 Action 14 was entered.

This occurrence constituted operation in a degraded mode in accordance with Technical Specification 6.9.1.9.b.

DESIGNATION OF APPARENT CAUSE OF OCCURRENCE :

The reason No. 24 Steam Generator Pressure Channel 4 failed high was the. ventilation damper stuck open, freening the pressure sensing line.

ANALYSIS OF OCCURRENCE:

Technical Specification 3.3.2 Action 14 requires:

With the number of operable channels one less than the

! total number of channels, operation may proceed until performance of the next required channel functional test, provided the inoperable channel is placed in the tripped condition iwithin one hour.

! ~

j ,

k 3

e.

i

{

x

, IIR 8 2'-001/03X-1 .

C,ORRECTIVE ACTION:

The ventilation damper was freed and exercised, then closed.

The pressure sensing line was thawed, tested, and returned to service. At 0325 hours0.00376 days <br />0.0903 hours <br />5.373677e-4 weeks <br />1.236625e-4 months <br />, January 10, 1982, Action Statement 3.3.2 Action 14 was terminated.

Design Change Request (DCR) 2SC-0160 was completed July 11, 1983. l This DCR installed temperature monitoring in the north and south penetration areas with associated alarms (at 390F) on the auxiliary annunciator in the control room. A similar design change (DCR ISC-0159) is being incorporat.ad on Salem Unit No. 1. I FAILURE DATA:

Not Applicable 2

Prepared By J. Rupp P" 2 L r--

// Gen (ral Man 6ger -

Salem Operations SORC Meeting No.83-141 1