05000311/LER-1982-039, Forwards LER 82-039/01T-0.Detailed Event Analysis Encl

From kanterella
Jump to navigation Jump to search
Forwards LER 82-039/01T-0.Detailed Event Analysis Encl
ML20054G293
Person / Time
Site: Salem 
Issue date: 06/07/1982
From: Midura H
Public Service Enterprise Group
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20054G294 List:
References
NUDOCS 8206210382
Download: ML20054G293 (3)


LER-1982-039, Forwards LER 82-039/01T-0.Detailed Event Analysis Encl
Event date:
Report date:
3111982039R00 - NRC Website

text

.

3PSEG Public Service Electric and Gas Company P.O. Box E Hancocks Bridge, New Jersey 08038 Salem Generating Station June 7, 1982 Mr.

R.

C. Haynes Regional Administrator USNRC Region 1 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr. Haynes:

LICENSE NO. DPR-75 DOCKET NO. 50-311 REPORTABLE OCCURRENCE 82-039/0lT Pursuant to the requirements of Salem Generating Station Unit No.

2, Technical Specifications, Section 6.9.1.8, we are submitting Licensee Event Report for Reportable Occurrence 82-039/0lT.

This report is required within fourteen (14) days of the occurrence.

Sincerely yours, l/..bVb0 i

H. J. Midura General Manager -

Salem Operations d[

RF:ks CC:

Distribution l

l l

l F206210382 820607 PDR ADOCK 05000311 A

PDR J

l Tn F:

m.

Dc e:3:

i i e. :

5 Report Number:

82-039/OlT Report Date:

06-07-82 Occurrence Date:

05-26-82 Facility:

Salem Generating Station, Unit 2 Public Service Electric & Gas Company Hancocks Bridge, New Jersey 08038 IDENTIFICATION OF OCCURRENCE:

Containment Service Water Leak - No. 21 Containment Fan Coil Unit.

This report was initiated by Incident Report 82-134.

CONDITIONS PRIOR TO OCCURRENCE:

Mode 1 - Rx Power 100% - Unit Load 1150 MWe.

DESCRIPTION OF OCCURRENCE:

On May 26, 1982, during routine operation, the Control Room Operator observed that No. 21 Containment Fan Coil Unit (CFCU) tripped after being started in high speed.

Shortly after, the Containment Sump Overflow annunciator alarmed, and the operator determined the containment sump pump had been running for approximately half an hour.

An inspection of containment was made, and a 100 GPM service water leak from No. 21 CFCU motor cooler was discovered.

The CFCU was isolated, and leakage was stopped.

The unit was declared inoperable at 1450 hours0.0168 days <br />0.403 hours <br />0.0024 weeks <br />5.51725e-4 months <br />, and Action Statement 3.6.2.3.a was entered.

In accordance with NRC IE Bulletin 80-24, the NRC was notified by telephone at 1505 hours0.0174 days <br />0.418 hours <br />0.00249 weeks <br />5.726525e-4 months <br />, with written confirmation transmitted on May 27, 1982.

This occurrence constituted abnormal degradation of the containment boundary in accordance with Technical Specification 6.9.1.8.c.

DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:

The service water leakage was from a failed motor cooler seam weld.

The fan motor insulation was damaged by the leakage, resulting in an overcurrent trip condition.

LER 82-039/0lT -

l ANALYSIS OF OCCURRENCE:

Technical Specification 3.6.2.3.a requires:

With one group of containment cooling fans inoperable and both containment spray systems operable, restore the inoperable group of cooling fans to operable status within 7 days, or be in at least hot standby within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in cold shutdown within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

NRC IE Bulletin 80-24 requires:

That containment service water leaks be considered as as abnormal degradation of the containment boundary.

CORRECTIVE ACTION

The failed motor cooler was properly replaced; however, attempts to dry out the fan motor failed.

The fan motor was properly replaced, and the unit was satisfactorily tested.

No. 21 CFCU was declared operable at 1336 hours0.0155 days <br />0.371 hours <br />0.00221 weeks <br />5.08348e-4 months <br />, June 2, 1982, and Action Statement 3.6.3.2.a was terminated.

FAILURE DATA:

Westinghouse Electric Corp.

Containment Fan Coil Unit Fan Motor Cooler

/!. h/

Prepared By R.

Frahm G'hetal Manager -

e Salem Operations SORC Meeting No.

82-57