05000272/LER-1982-025, Forwards LER 82-025/03L-0.Detailed Event Analysis Encl

From kanterella
Jump to navigation Jump to search
Forwards LER 82-025/03L-0.Detailed Event Analysis Encl
ML20053E064
Person / Time
Site: Salem 
Issue date: 05/26/1982
From: Midura H
Public Service Enterprise Group
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20053E065 List:
References
NUDOCS 8206070573
Download: ML20053E064 (3)


LER-1982-025, Forwards LER 82-025/03L-0.Detailed Event Analysis Encl
Event date:
Report date:
2721982025R00 - NRC Website

text

,

O PSEG Public Service Electric and Gas Cornpany P.O. Box E Hancocks Bridge. New Jersey 08038 Salem Generating Station May 26, 1982 Mr.

R.

C. Haynes Regional Administrator USNRC Region 1 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr. Haynes:

LICENSE NO. DP R-7 0 DOCKET NO. 50-272 REPORTABLE OCCURRENCE 82-025/03L Pursuant to the requirements of Salem Generating Station Unit No. 1, Technical Specifications, Section 6.9.1.9.b, we are submitting Licensee Event Report for Reportable Occurrence 82-025/03L.

This report is required within thirty (30) days of the occurrence.

Sincerely yours,

/

H.

J. Midura General Manager -

Salem Operations RF:ks CC:

Distribution Ohhhohfp O

PDR

Import Number:

82-025/03L

/

Report Date:

05-26-82 Occurrence Date:

05-01-82 Facility:

Salem Generating Station, Unit 1 Public Service Electric & Gas Company Hancocks Bridge, New Jersey 08038

' IDENTIFICATION OF OCCURRENCE:

No. 13 Steam Generator Wide Range Level - Inoperable.

This report was initiated by Incident Report 82-106.

CONDITIONS PRIOR TO OCCURRENCE:

Mode 1 - Rx Power 89% - Unit Load 1024 MWe.

DESCRIPTION OF OCCURRENCE:

On May 1, 1982, during routine startup operation, the Control Room Operator discovered that No. 13 Steam Generator Wide Range Level indication had failed low.

The channel was declared inoperable at 1055 hours0.0122 days <br />0.293 hours <br />0.00174 weeks <br />4.014275e-4 months <br />, and Limiting Condition for Operation 3.3.3.7.a Action 1 was entered.

This occurrence constituted operation in a degraded mode in accordance with Technical Specification 6.9.1.9.b.

DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:

A piece of solid wire was found shorting the instrument signal-lead to-the conductor shield.

ANALYSIS OF OCCURRENCE:

Technical Specification 3.3.3.7.a Action 1 requires-With the number of operable accident monitoring channels less than the required number of channels, restore the inoperable channel (s) to an operable status within 7 days, or be in hot shutdown within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

LER 82-025/03L.

CORRECTIVE ACTION

The wire was removed and the channel was satisfactorily tested.

At 1545 hours0.0179 days <br />0.429 hours <br />0.00255 weeks <br />5.878725e-4 months <br />, No. 13 Steam Generator Wide Range Level was declared operable, and Limiting Condition for Operation 3.3.3.7.a Action 1 was terminated.

The possibility of attempted sabotage was con-sidered, and immediate notification to the NRC was made in accor-dance with 10 CFR 50.72.

Subsequent investigation showed that the wire was left in the cabinet after a recent design modifi-cation; the investigation results were summarized in a report by the SORC in meeting 82-47, May 5, 1982.

This occurrence in no way endangered the general public or the environment.

FAII.URE DATA:

Not Applicable.

Prepared By R.

Frahm

/ h.

Genera'l Mahager -

Salem Operations SORC Meeting No.82-53A 1

4 r

,.r-.

---y