SWAGELOK COMPANY 29500 Solon Road, Solon, Ohio 44139-3492 U.S.A.
February 25, 1999 Document Control Desk Office of Reactor Regulation Nuclear Regulatory Commission Washington, DC 20555
Subject:
Defects Potentially Reportable under 10CFR21 We are writing further to our notification of January 29, 1999 about a possible defect in a Swagelok pipe fitting tee, part number SS-6-T.
The two utilities to whom we have sold these parts are repeated in the appendix to this letter, along with a drawing of the affected part.
As we reported earlier, the possible defect is a crack in the center of the forging. We have determined that the crack occurred because the heated bar was not properly located in the first station of the die, which is when the bar is flattened to assure correct fill of the die.
At this time we have only found one part out of the 7396 pieces in the forging lot that was cracked.
When this part was forged in 1996, our procedure was to visually inspect suspect lots for this condition. Since 1998, we have implemented 100% dye penetrant on suspect lots. We 1
are also investigating an error free system for this process.
/ ;
There was no defect in the forging material.
If there are any questions, please do not hesitate to contact us.
e J. Malec v; ce President & General Manager 9903160153 990225 PDR ADOCK 05000272 S
PDR 1-50017 Telephone: 440-248-4600 Fax: 440-349-5970
~
I This print Is the exduslve property of CAJON COMPANY. It Is confidential and Is loaned to you for a limited purpose and must be returned on request. Neither this print nor any Information concerning It may be copied, exhibited or furnished to others without the consent of CAJON COMPANY. Moreover. the parts on this print are the subject of Issued patents and/or pending applications and may not be manufactured without permission of CAJON COMPANY.
NOTE:
- 1) ALL DIMENSIONS ARE FOR REFERENCE ONLY. SUBJECT TO CHANGE PART NO.
SS-( b)-T
- 2) METRIC EQUIVALENTS ARE SHOWN BELOW DECIMAL INCH' DIMENSIONS
- 3) ALL ENDS IDENTICAL CUSTOMER DRAWING
~-H-R.-tEF. ~-F WRENCH FLAT I~
NPT SIZE PART NO.
NPT H
F L
- ...J ~
~I V) 3 a:: z z
0
<(1-W<(
ii) a:: a:: I- -.
0<(<( I
~(LI:~
w 0::
003
@DOI:
<( <( 0
---t---+ -~,
1ft'C'-
~~
/7 /.
r-1)
-v v v MFG.
CUST. SERV.
DRAWN BY CHECKED BY 20 36.1 2.84 13/16 1.42-3/8" SS-6-T 72.1
\\
I SCALE PART NO.
SS-( b)-T NONE DMW 12-JAN-98
~c:::>~
COMPANY
'fl.._
\\-\\..\\--1\\'b I
I it.
&~~~~~
SWAGELOK COMPANY 29q00 Solon Road, Solon, Ohio 44139-3492 U.S.A.
Public Service Electric & Gas Hancocks Bridge, NJ Nuclear Dept Material Center P.O. #P2 0965486 1000 20 Pcs SS-6-T Product ID R27GE0123B S.C. Electric & Gas Co.
VC Summer Station Highway215 Jenkinsville, SC 29065 P.O.# SR 702966 3 Pcs. SS-6-T Product ID R27GE0123B Telephone: 440-248-4600 Fax: 440-349-5970